XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012 1 Aging test of high rate MRPC Wang Yi Department of Engineering.

Slides:



Advertisements
Similar presentations
Wang Yi, Tsinghua University SoLID collaboration meeting, Status of MRPC-TOF 1 Wang Yi Department of Engineering Physics Tsinghua University,
Advertisements

Development of high rate RPCs Lei Xia Argonne National Laboratory.
Development of timing RPCs Presented by P.Fonte for the TOF-RPC group.
Aging, High Rate and Shielding L. Lopes Lip-Coimbra.
Status of MRPC-TOF Wang Yi Department of Engineering Physics Tsinghua University, Beijing, China 1.
Status of the LHCb RPC detector Giovanni Carboni - Roma 2 Introduction Detector requirements Ageing tests Oil vs. No-Oil Conclusions Report to LHCC - March.
ARNAB BANERJEE Variable Energy Cyclotron Centre, India.
HCAL with Resistive Plate Chambers José Repond Argonne National Laboratory Presented at the Chicago Linear Collider Workshop January 7-9, 2002.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
MRPC R&D and production Yongjie Sun Center of Particle Physics and Technology, USTC.
New MRPC prototypes developed in Tsinghua Unversity Huangshan Chen (Tsinghua Unversity)
Mauro Raggi Status report on the new charged hodoscope for P326 Mauro Raggi for the HODO working group Perugia – Firenze 07/09/2005.
Wang Yi, Tsinghua University Joint meeting of HALL A and HALL C, SoLID status and Chinese contribution 1 Wang Yi Department of Engineering.
09/12/2009ALICE TOF General meeting 1 Online Controls Andrea Alici INFN and Universtity of Bologna, Bologna, Italy ALICE TOF General Meeting CERN building.
November 5, 2004V.Ammosov ITEP-Moscow, Russian CBM meeting 1 IHEP possible participation in CBM TOF system Vladimir Ammosov Institute for High Energy Physics.
1 July GEM R&D Activity in USTC Yi Zhou University of Science & Technology of China.
15 th CBM collaboration meeting, GSI, Darmstadt, Germany, April 12-16, 2010Wang Yi, Tsinghua University R&D status of low resistive glass and high rate.
First results of an aging test of a full scale MWPC prototype for the LHCb muon system Workshop on “Aging Phenomena in Gaseous Detectors”, October 2-5.
1 Aging Study for SiD Hcal and Muon System RPCs (University Linear Collider Detector R&D, project 6.19) Changgo Lu, W. Sands, K. T. McDonald, A.J.S. Smith.
The dynamic behaviour of Resistive Plate Chambers
RPC R&D status in Bucharest (JRA12-I3HP) Mihai Petrovici - CBM-Meeting, GSI, March 1,2006 Short history SMSMGRPC – Glaverbel Glass Prototype –Construction.
Third workshop on hadron physics in ChinaWang Yi, Tsinghua University A conceptional design of SOLID-TOF Outline: Development of low resistive glass and.
RPC detection rate capability ≈ 1/ρ Float-Glass ( Ω-cm) RPC rate capability < Bakelite( Ω-cm) one. New kind of doped glass was developed.
Design of a readout system for RPCs Olu Amoda2 The LODEN Group The group is an association of Fermilab scientists who teamed up to build a cosmic ray.
Prototypes of high rate MRPC for CBM TOF Jingbo Wang Department of Engineering Physics, Tsinghua University, Beijing, China RPC-2010-Darmstadt, Germany.
STAR regional meeting, October UniversityWang Yi, Tsinghua University New MRPC R&D in Tsinghua University Outline: Introduction of MRPC.
RPCs of BESIII Muon Identifier  BESIII and muon identifier  R&D  Mass production  Installation Zhang Qingmin Advisor: Zhang Jiawen.
Andrea Di Simone Andrea Di Simone – INFN Roma2 Andrea Di Simone CERN PH/ATC and INFN-CNAF On behalf of ATLAS RPC groups: Lecce, Napoli, Protvino, Roma2.
Proposal for large-area high- rate Time-of-Flight and Muon Telescope Detector with MRPC technology for EIC Zhangbu Xu (BNL) BNL, Rice, UCLA, Tsinghua,
Report on beam test results of high-rate MRPCs Jingbo Wang Department of Engineering Physics, Tsinghua University, Beijing, China.
长读出条 MRPC 性能研究 孙勇杰 Key Laboratory of Technology of Particle Detection and Electronics, USTC-IHEP, CAS Center of Particle Physics and Technology, USTC.
MRPC Beam GSI Yongjie Sun University of Science and Technology of China.
Update on DHCAL and RPC progress Lei Xia ANL - HEP.
STAR-MTD March 30 th -April 1 th, 2011 Wang Yi, Tsinghua University 1 Final design and plan for LMRPC production Outline: LMRPC structure.
Performance of Prototype MRPC Detector for STAR Frank Geurts (Rice Univ.) for the STAR TOF collaboration.
1 GEM R&D Activity in USTC Yi Zhou University of Science & Technology of China.
Results from the CMS-RPC tests at CERN Gamma Irradiation Facility Roberto Guida CMS-RPC (Bari, Beijing, Napoli, Pavia, Sofia) Seoul, October 2005.
30 October 2003V.Souvorov / B.Schmidt - MWPC PRR CERN site1 MWPC Aging Studies Outline: Overview of aging tests done Results in terms of gain variations.
Quality control for large volume production GEM detectors Christopher Armaingaud On behalf of the collaboration GEMs for CMS.
Test results of Multi-gap RPC Test Chambers for a Digital HCAL  Geometrical design  Test setup  Signal: avalanche mode and streamer mode  Comparison.
Marcello Abbrescia RPCs for CMS during Phase II RPC rate capability M. Abbrescia, The dynamic behaviour of Resistive Plate Chambers, NIM A 533 (2004) 7–10.
XIII workshop on RPC and related detectors. GENT university, Belgium, Feb Wang Yi, Tsinghua University 1 Development and test of real-size.
1 Analysis of Small RPC DHCAL Prototype Data (noise and cosmic ray) LCWA09, Albuquerque, New Mexico Friday, October 02, 2009 Qingmin Zhang HEP Division,
NoV. 11, 2009 WP meeting 94 1 D. Attié, P. Colas, E. Ferrer-Ribas, A. Giganon, I. Giomataris, F. Jeanneau, P. Shune, M. Titov, W. Wang, S. Wu RD51 Collaboration.
Ingo DeppnerDPG-Frühjahrstagung, Darmstadt, März Outline: CBM-ToF requirements What is an (M)RPC? Tof wall arrangements Ceramics RPC and.
Workshop on STAR upgrade. Sep th, 2015, USTC, Hefei Wang Yi, Tsinghua University 1 Status of high rate MRPC for CBM-TOF Outline: Introduction of.
7 th Workshop on Hadron Kunshan Univ Wang Yi, Tsinghua University 1 Conceptual design of SoLID-TOF and aging test Outline: Conceptual design.
NSS2006Shengli Huang1 The Time of Flight Detector Upgrade at PHENIX Shengli Huang PHENIX Collaboration Outlines: 1.Physics motivations 2.Multi-gap Resistive.
CMS – RPC GIF++ G. Pugliese on behalf of the RPC Collaboration 1.
2013 核电子学 ASIC 技术研讨会, 2013/10/14 基于电流模的 MRPC 探测器读出 ASIC 研究 报告人:周新 指导老师:邓智.
TPC for ILC and application to Fast Neutron Imaging L. An 2, D. Attié 1, Y. Chen 2, P. Colas 1, M. Riallot 1, H. Shen 2, W. Wang 1,2, X. Wang 2, C. Zhang.
Construction of RHIC-STAR TOF and high rating MRPC Wang Yi Department of Engineering Physics, Tsinghua University Beijing,100084, China.
Department of Engineering Physics, Tsinghua University, Beijing, China
Quality Control Chamber Production
Results achieved so far to improve the RPC rate capability
Saikat Biswas, A. Abuhoza, U. Frankenfeld, C. Garabatos,
RPC working gas (C2H2F4/i-C4H10/SF6): Simulation and measurement
Multigap Resistive Plate Chambers (MRPC)
Results from a preliminary analysis of the MWPC test at the GIF
Conceptual design of TOF and beam test results
RPC and LST at High Luminosity
BESIII RPC Detector Jiawen Zhang
STAR TOF MRPC Mass Production & Q.C. (USTC)
Performance of a Multigap RPC prototype for the LHCb Muon System
Update on SoLID-TOF Wang Yi Outline: Conceptual design of SoLID-TOF
High time resolution TOF for SoLID
High time resolution TOF for SoLID
Development of Resistive Plate Chamber for charge particle detection
Aging test of glass and MRPC
A DLC μRWELL with 2-D Readout
Presentation transcript:

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, Aging test of high rate MRPC Wang Yi Department of Engineering Physics Tsinghua University, Beijing, China

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February,  Introduction  Related Research  Experimental Setup  Simulation  Results & Discussion  Conclusions Outline

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, World map of MRPC’s rate capability

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, Surface roughness: <10 nm (peak-to-valley) 50cm x50cm Uniformity: <20 μm Typical: 5 μm Thickness distribution (Evaluation scale= 30cm) micrometer caliper Evaluation scale= 857μm Variation: <30%

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, Time Resolution:<80ps Efficiency:>90% Rate Capability:>25kHz/cm 2 Aging effect: Performance degradation of material, glass, mylar, et al. Performance degradation of detector.

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  X-Ray source: X-ray Generator  Gas Mixture: ◦ 90% Freon, 5% iso-butane, 5% SF 6  Irradiation Area: 2×2 cm 2  Dose Rate: 2.16×10 -3 Gy/h  Irradiation Time: 300h  Total Charge: 0.22C Glass type: Low-resistive glass Gas gap (×10) : 0.25mm Readout Pad (×12) : 2cm×2cm Active area: 13cm×4.2cm MRPC Module: 12pad high rate 6

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012 High Dose Rate Test Dose Rate: 2.87×10 -2 Gy/h Irradiation Time: 24h Great Degradation of main Specifications can be seen. Low Dose Rate Test Dose Rate: 5.4×10 -4 Gy/h Irradiation Time: 530h No significant performance degradation Wang Yi, Kang Ke-Jun, Cheng-Jian-Ping et al., Aging Test of Multi-Gap Resistive Plate Chambers. HEP & NP 30(2006) 5 Efficiency → Time Resolution ↗↗ Noise Rate ↗↗ Dark Current ↗↗ Turn off for a while 7

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012 Low Dose Rate Test Dose Rate: ~10 -3 Gy/h Irradiation Time: ~4 Months No Obvious Aging Effect. High Dose Rate Test Dose Rate: ~10 -2 Gy/h Irradiation Time: ~60h Several Aging Problems is observed. Wu Yuelei, et al., Aging Effect of Multi-Gap Resistive Plate Chambers, USTC, May 2005 Efficiency → Time Resolution ↗↗ Noise Rate ↗↗ Dark Current ↗↗ 8

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, N471A Box with constant temperature I MON HV ground Agilent Digital Multimeter Computer The current was monitored in the interval 0f 30s HV aging test of glass

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, This glass was applied with 1000V for about 32days, integrated charge: 1 C/cm 2 --roughly corresponding to the CBM life-time over 5 years operation at the maximum particle rate. Current changes with test time

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  X-ray Generator  MRPC Setup  Gas System  Monitoring System Spellman™ XRB80 High Voltage: 60kV Current: 0.5mA Dose Rate: 2.16×10 -3 Gy/h (at 1m) During aging test, the X-Ray Tube is closed for 30 minutes every 8-10 hours in order to prevent damage and study the responding behavior. 11

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  X-ray Genarator:  MRPC Setup  Gas System  Monitoring System Irradiation Area High Voltage: ±6600V Dark Current: ~7nA Noise Rate: ~150Hz/Pad 12

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  X-ray Genarator:  MRPC Setup  Gas System  Monitoring System 13

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  X-ray Genarator:  MRPC Setup  Gas System  Monitoring System Monitoring Interval: 1min 14

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  During irradiation, the current of the MRPC module is 50nA/cm 2, this intensity is comparable to 15 kHz/cm 2 electron beam (tested at HZDR). Rossendorf Beam Test Data 50nA 15kHz/cm 2 15 Beam test

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  The energy deposition distribution caused by X-Rays.(MCNP) High Voltage: 60kV 16 Energy spectrum of X-ray machine

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  The energy distribution of X-Rays generated.  The number of electrons produced in each gap.(MCNP) X-Ray Glass type: Low-resistive glass Gas gap (×10) : 0.25mm Readout Pad (×12) : 2cm×2cm Active area: 13cm×4.2cm 17

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  The energy distribution of X-Rays generated.  The number of electrons produced in each gap. 1/2 There is 30% less electrons in the the last gap of each half, compared to the first one. The upper half ages twice than the lower half. (However, ×2 error is reasonable in aging test.) 18 30%

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  1 st run Irradiation Time: 101.3h Noise rate: ~130Hz/Pad Dark current: ~7nA X-ray is turned of for 30min A long time without X-ray 19

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  1 st run  2 nd run Irradiating Time: 99.0h Noise rate: ~200Hz/Pad Dark current: ~7nA 20

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  1 st run  2 nd run  3 rd run Irradiating Time: 104.1h Noise rate: ~300Hz/Pad Dark current: ~8nA 21 Spark

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  Time Resolution Time Resolution(ps) Before irradiation90.0 After 100h’s irradiation94.5 After 300h’s irradiation

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  Response Experiment Common Glass MRPC Wang Yi, Kang Ke-Jun, Cheng-Jian-Ping et al., Aging Test of Multi-Gap Resistive Plate Chambers. Chinese Physics C30(2006) 1-5 Up-rush Off-On 23

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  Response Experiment Interval: 5sec On 4mA for X-ray Tube On 5mA for X-ray Tube The high rate MRPC responds very fast without an up-rush of signal. 24 High Rate MRPC

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, 2012  The low resistive glass shows very promising performance and passed HV aging test.  Within 300h’s operation, the performance of high rate MRPC module has shown the hardiness against irradiation. A dose rate of 2.16×10 -3 Gy/h or a counting rate of 15kHz/cm 2 does not cause obvious aging effect.  Compared to common glass MRPC, high rate MRPC responds and reaches a stable state faster.  Further study will be done. 25

XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, Thank You!