Feedforward Control ( 前馈控制 ) Liankui DAI Institute of Industrial Control, Zhejiang University, Hangzhou, P. R. China 2009/04/22.

Slides:



Advertisements
Similar presentations
Tuning PID Controller Institute of Industrial Control,
Advertisements

Automation I. Introduction. transmitter actuator Structure of control system Process or plant Material flow sensorstransducers actuating units actuating.
Ch3 Feedback control system characteristics
Ratio Control Chapter 15.
LECTURE#08 PROCESS CONTROL STRATEGIES
Case Study #1: Boiler Control 锅炉控制
THE INTRODUCTION OF AUTOMATIC PROCESS CONTROL
Exponential Tracking Control of Hydraulic Proportional Directional Valve and Cylinder via Integrator Backstepping J. Chen†, W. E. Dixon‡, J. R. Wagner†,
Chapter 7 System Compensation (Linear Control System Design)
CHE 185 – PROCESS CONTROL AND DYNAMICS
A Typical Feedback System
Enhanced Single-Loop Control Strategies
Chapter Summer 2. Comparator 3. Block Blocks in Series
Chapter 11 1 Closed-Loop Responses of Simple Control Systems In this section we consider the dynamic behavior of several elementary control problems for.
Chapter 8. The PID Controller Copyright © Thomas Marlin 2013
Open loop vs closed loop By Norbert Benei ZI5A58.
Luck: When preparation meets opportunity.
Introduction to Industrial Control Systems
Cascade, Ratio, and Feedforward Control
1 Overview of Control System Design Chapter 13 1.Safety. It is imperative that industrial plants operate safely so as to promote the well-being of people.
Process Characteristics (过程动态特性分析)
ERT 321 PROCESS CONTROL & DYNAMICS
ERT 210/4 Process Control & Dynamics
Cascade and Ratio Control
A Typical Feedback System
DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS
Chapter 3 mathematical Modeling of Dynamic Systems
Ch6 The Root Locus Method. Main content §The Root Locus Concept §The Root Locus Procedure §Generalized root locus or Parameter RL §Parameter design by.
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
Model Reference Adaptive Control (MRAC). MRAS The Model-Reference Adaptive system (MRAS) was originally proposed to solve a problem in which the performance.
Control Systems and Adaptive Process. Design, and control methods and strategies 1.
Chapter 11 1 Stability of Closed-Loop Control Systems Example 11.4 Consider the feedback control system shown in Fig with the following transfer.
Coupling Analysis of Multivariable Systems ( 多变量系统的关联分析 ) Lei XIE Zhejiang University, Hangzhou, P. R. China.
بسم الله الرحمن الرحيم Advanced Control Lecture one Mohammad Ali Fanaei Dept. of Chemical Engineering Ferdowsi University of Mashhad Reference: Smith &
Feedback Control system
Chapter 6 Analysis of Feedback Control Systems Prof. Shi-Shang Jang Chemical Engineering Department National Tsing-Hua University Hsin Chu, Taiwan June,
Open-loop control system Closed-loop control system
Chapter 4 A First Analysis of Feedback Feedback Control A Feedback Control seeks to bring the measured quantity to its desired value or set-point (also.
INSTRUMENTATION & CONTROL
1 II. Bottom-up Determine secondary controlled variables and structure (configuration) of control system (pairing) A good control configuration is insensitive.
Tier 2Modulo 15NAMP Process Control and Process Integration 1 Created at Universidad de Guanajuato & École Polytechnique de Montréal Module 15: Process.
President UniversityErwin SitompulSMI 1/1 Dr.-Ing. Erwin Sitompul President University Lecture 1 System Modeling and Identification
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
1 Control of maldistribution of flow in parallell heat exchangers Magnus G. Jacobsen, Sigurd Skogestad Nordic Process Controi workshop, Porsgrunn
Lecture 2: Mathematical Modeling Copyright © Thomas Marlin 2013 The copyright holder provides a royalty-free license for use of this material at non-profit.
Inferential Control Control Using a Single Secondary Measurement.
Chapter 3 : Simple Process Dynamics and Transfer Function
Introduction Control Engineering Kim, Do Wan HANBAT NATIONAL UNIVERSITY.
Name of Student : PATEL ARPITKUMAR RAJNIKANT Enrollment No
MISS. RAHIMAH BINTI OTHMAN
CONTROL SYSTEM UNIT-IV Datta Meghe Institute of engineering Technology and Research Sawangi (meghe),Wardha 1 DEPARTMENT OF ELECTRONICS & TELECOMMUNICATION.
Feedforward Control ( 前馈控制 ) Dai Lian-Kui Shen Guo-jiang Institute of Industrial Control, Zhejiang University.
Control of Distillation Column (精馏塔控制)
Control of Distillation Column (精馏塔控制) Dai Lian-Kui Shen Guo-jiang Institute of Industrial Control, Zhejiang University.
Cascade Control Systems (串级控制系统)
1 PID Feedback Controllers PID 反馈控制器 Dai Lian-kui Shen Guo-jiang Institute of Industrial Control, Zhejiang University.
Lecture 9\10 Analysis in the time domain (III) North China Electric Power University Sun Hairong.
Decoupling Control Schemes of Multivariable Systems ( 多变量系统的解耦控制 ) Dai Lian-Kui Shen Guo-jiang Institute of Industrial Control, Zhejiang University.
ERT 321 – Process Control & Dynamics Feedforward & Ratio Control Ms Anis Atikah Ahmad
بسم الله الرحمن الرحيم وبه نستعين
Open loop vs closed loop
ERT 321 – Process Control & Dynamics Feedforward & Ratio Control
Feedforward Control (前馈控制)
Digital Control Systems & Digital PID Controller
Course PEF3006 Process Control Fall 2018 Feedforward Control
Process Control Engineering
Enhanced Single-Loop Control Strategies
Overview of Control System
Course PEF3006 Process Control Fall 2017 Feedforward Control
Interacting vs. Noninteracting Systems
Presentation transcript:

Feedforward Control ( 前馈控制 ) Liankui DAI Institute of Industrial Control, Zhejiang University, Hangzhou, P. R. China 2009/04/22

Contents Feedforward Concept Design of Linear Feedforward Controllers Design of Nonlinear Feedforward Controllers Design Examples of Feedforward Control Feedforward-Feedback Control Simulation Results Summary

Problem Discussion Consider the heat exchanger shown in the figure, it is required to control the outlet temperature of process fluid, T, by manipulating the steam flow, R V. Please design the relevant control schemes on the diagram for the following cases: Case #1: both of the flow, R F, and steam inlet pressure, P V, are stable; Case #2: R F is stable, but P V varies frequently; Case #3: P V is stable, but R F varies frequently; Case #4: both of P V and R F varies frequently.

Feedback or Feedforward Control Examples Feedback Control SchemeFeedforward Control Scheme

Feedforward Concept D 1 (t), …, D n (t) represent some measurable disturbances to the controlled variable Idea: to compensate for some measurable disturbances before they affect the controlled variable.

Feedforward / Feedback Control

Design of Linear Feedforward Controllers Design Objective:

Design of Linear Feedforward Controllers (cont.) Design formula for the feedforward controller: Design Objective:

Design of Linear Feedforward Controllers (cont.) Design formula for the feedforward controller: ( Why ? )

Types of Feedforward Controllers Steady-State or Dynamic Feedforward Controller ( 静态前馈控制与动态前馈控制 ) Linear or nonlinear Feedforward Controller ( 线性前馈控制与非线性前馈控制 ) Discuss the common-used feedforward controller

Simulation Results of Linear Feedforward Controllers (Please see…/FFControl /ExHeaterLinearFFC.mdl)

Nonlinear Steady-state Feedforward Control Steady-state Equation Discuss the realization of nonlinear feedforward controller and the effect of relevant measurements

Nonlinear Steady-State Feedforward Control Simulation (Please see …/FFControl/ExHeaterStaticFFC.mdl)

Comparison of Feedforward and Feedback Control Feedforward ControlFeedback Control Disturbances are measurableCV is measurable Control MV based on disturbances Control MV based on control ERROR Open-loop, No Stability Problem Closed-loop, Stability is the most important Only some disturbances are detected All disturbances are detected Accurate model needed for both of Control and Disturbance Paths No accurate model needed Not adaptable to nonlinear or time-varied systems Adaptable to nonlinear or time- varied systems

FFC+FBC Scheme #1 for Heat Exchanger Steady-state output and smooth switch problem ?

FFC+FBC Scheme #2 for Heat Exchanger

Summary Cases which may introduce feedforward control (1) Primary Controlled Variable is not measurable (2) Primary CV is measurable, but some disturbances are too strong for feedback control systems Conditions to apply feedforward control (1) Main disturbances are measurable (2) Response speed of disturbance path is slower than that of control path (3) Characteristics of disturbance and control path are almost invariable