KETA series Imaging System 2016/6/27 1 Gel Documentation (G) Multi-Purpose (M) Chemiluminescence (C)

Slides:



Advertisements
Similar presentations
600TV Lines 3D-DNR HSBLC Advanced WDR 600TV Lines 3D-DNR HSBLC Advanced WDR High Resolution Image. 3 Dimension-Digital Highlight Suppress Wide Dynamic.
Advertisements

 Used plasmid DNA, [pDNA] = 0.2ug/uL  Made two 1% Agarose Gel: 1 with EtBr & 1 without EtBr  Prepared 6 samples of pDNA to be loaded in each gel with.
ABRF meeting 09 Light Microscopy Research Group. Why are there no standards? Imaging was largely an ultrastructure tool Digital imaging only common in.
Market introduction CellaTemp PA.  Newest interface technology  Latest high-resolution microprocessors  Newest sensors  New amplifier technology 
BioImaging Systems for Genomics, Proteomics, Plant and Animal Research
Graphics and Still Images John H. Krantz Hanover College.
History of Digital Camera By : Dontanisha Williams P2.
Digital Images The nature and acquisition of a digital image.
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
Lesson Objectives Explain the representation of an image as a series of pixels represented in binary Explain the need for meta data to be included in the.
Thin film or complex multi-layer plating Thickness Measurement application Other customer interesting elements analysis application # Dae-Ryung Techno.
UVP BioImaging Systems Solutions for the Science of Life Digital CCD Cameras 101.
Introducing the LEO 1400 Series
Practical aspects of fluorescence microscopy
Photographics 10 Introduction to Digital Photography
Prepared by George Holt Digital Photography BITMAP GRAPHIC ESSENTIALS.
Gel Electrophoresis of DNA
Point and Shoot Digital SLR-Single Lens Reflex (DSLR) Prosumer- Not technically its own specification-combines user friendly P&S features with.
[1] Reference: QCam API reference manual document version Charge Coupled Device (CCD)
What’s new in Fireworks 8 Optimization Integrated workflow Create without complexity Workflow Improvements.
TOPIC 4 INTRODUCTION TO MEDIA COMPUTATION: DIGITAL PICTURES Notes adapted from Introduction to Computing and Programming with Java: A Multimedia Approach.
Photoshop Software Rasterized, file formats, and printing choices.
8000 Series Options/Technical Overview Series Precision Digital Multimeter New Technology – Multi Processor design No need for AutoCal – High precision.
Let’s Buy a Camera! Produced by Mrs. Gallagher-Edlund.
Digital Cameras. Image Capture  Images are captured by the image sensor, then stored in the camera in a memory device.  Sensors convert light into an.
Bit-Mapped Graphic Data: Input (Capture) Hardware Multimedia – Section 2.
Chapter 1 INTRODUCTION TO IMAGE PROCESSING Section – 1.2.
Astrophotography The Basics. Image Capture Devices Digital Compact cameras Webcams Digital SLR cameras Astronomical CCD cameras.
CCTV Camera Component and Technology Imaging sensor Optic - Lens Camera Technology IP vs analogue CCTV Uniview IPC features Fundamental of CCTV.
Logo Introduction To investigate if white 96-well plates allow better fluorescence detection of PCR products during QPCR assays than natural 96-well plates.
Chapter 16: Detection Methods.  Agarose Gels  Ethidium Bromide ▪ Amounts as little as 10 ng per band ▪ Including in the gel OR staining after electrophoresis.
Digital Cameras And Digital Information. How a Camera works Light passes through the lens Shutter opens for an instant Film is exposed to light Film is.
Development of Western Blots for Actin without the use of radioactivity Geoff Theobald STEP Summer Internship Program June 2003.
Photography The ages of the camera from analogue to digital.
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
In the Know … Technological Vocabulary. Movin’ on Up Terms 1. Available Light – Light in a room (sunlight or existing room light) 2. Bit Depth – the color.
Microscope Control Configuration This section of the QED manual will describe how to configure you Configure and Control your automated microscope. Mac.
CONFIGURING YOUR CAMERA. IMAGE SIZE AND COMPRESSION  Your camera probably allows you to select a number of different size and compression settings. 
Chapter 10 DNA Detection Methods: Fluorescent Dyes and Silver Staining ©2002 Academic Press.
Copyright 1999, Media Cybernetics, L.P. Gel-Pro Imager Kit.
Bitmap Graphics. Bitmap Basics Bitmap Graphic Bitmap Graphic Paint Software Paint Software.
FROM IMAGES TO ANSWERS Live Cell Imaging - Practical Issues Silver Spring & San Diego, June 2005.
Science 10 – Unit C BIOLOGY Chapter 1 – The Microscope.
Digital Imaging. Introduction Digital Imaging is used every day in life. Has become less expensive and easier to use than film.
Lesson 2: Introduction to Digital Imaging Digital Photography MITSAA IAP 2003 Rob Zehner.
In the Know … Technological Vocabulary. Beginning Terms 1. Aperture – the mechanical opening in the lens that lets light in. 2. ASA / ISO – rating given.
Fundamentals of Digital Images & Photography. Pixels & Colors The pixel (a word invented from "picture element") is the basic unit of programmable color.
TOPIC 4 INTRODUCTION TO MEDIA COMPUTATION: DIGITAL PICTURES Notes adapted from Introduction to Computing and Programming with Java: A Multimedia Approach.
HOW SCANNERS WORK A scanner is a device that uses a light source to electronically convert an image into binary data (0s and 1s). This binary data can.
Learning the Basics The tutorial in this section is designed to introduce you to the basic image acquisition and analysis tools within QED. You can go.
Scanner Scanner Introduction: Scanner is an input device. It reads the graphical images or line art or text from the source and converts.
COLORIMETRY & SPECTROPHOTOMETR
GS-1150 HANDHELD SPECTROPHOTOMETER. ABOUT GAMMA SCIENTIFIC With over 50 years of experience in developing commercial light measurement instruments, Gamma.
Bioanalytik detect and identify Over 25 years experience in Imaging Benefits of NightOWL.
Digital Image -M.V.Ramachandranwww.youtube.com/postmanchandru
Date of download: 7/5/2016 Copyright © 2016 SPIE. All rights reserved. Spatial light modulator-two-photon microscope (SLM-2PM) scheme: (1) Ti:Sa laser.
EverFocus IP Camera Image Adjustment GTS. Agenda 1. Cameras response to day and night modes (day-night- Auto) 2. Levels of IR led when to be activated.
Bioanalytik detect and identify Over 25 years experience in Imaging Benefits of NightOWL.
What is the difference between PSD and CCD sensor technology?
What is a digital image ? 1.
Introducing: Cytation™3 Cell Imaging Multi-Mode Reader
IncuCyte Training Calibrations and Troubleshooting
The best just got even better
BCA blue complex.
Gel Documentation system(Gel Doc)
System Overview CHRISS Combined High-Resolution Imaging and Spectroscopy System Intelligent Systems Group – University of Duisburg-Essen, Germany.
Chapter I, Digital Imaging Fundamentals: Lesson II Capture
Introduction to Digital Photography
WesternBright™ ECL/ ECLspray
Wendy F. Ochoa, Anju Chatterji, Tianwei Lin, John E. Johnson 
Presentation transcript:

KETA series Imaging System 2016/6/27 1 Gel Documentation (G) Multi-Purpose (M) Chemiluminescence (C)

Features of KETA series systems Robotic controlling system including: Motorized lens and filter wheel, auto sample stage(option) MC100/U10 LED: Multi color Epi-LED provides the basic fluorescence experiment. U10 white LED for sample placement. 2016/6/ Advanced, Automatic controlling system -

KD100 dark room: Absolute light-tight dark room suitable for chemiluminescence experiment. Leakage proof folding Optional SELM 200 Upgradeable high intensity Xenon light as excitation light of live plant and animal fluorescence detection. 2016/6/27 3 Safety inter lock Safety Switch Smart Latch AS100 Auto stage

Status display Signal light Customize idling time setting MD25K 312 nm UV Transilluminator (Also in KETA G) Intensity of UV light was controlled by computer Dedicate controlling software: Magic 1D & Magic Chemi 2016/6/27 4

5 KETA M Robotic Models: M: 2/3 ”, Peltier cooled ML: 2/3 ”, 2 stage Peltier cooled MLX: 2/3 ”, 16 bits, Peltier cooled Outstanding performance on gel documentation and highly sensitive on Chemi experiments.

KETA M KETA MLKETA MLX Gel Analysis Fluorescence Chemiluminescence /6/27 6

7 Camera of KETA M Series K12CHK12CHSK16CH CCD size 2/3" Depth 12/16. A/D bit 16 bit Grayscale 4096 / Resolution 1360X X 2048 S/N >62 dB>67 dB>69 dB Pixel Size 6.45 μm x 6.45 μm 7.4 μm x 7.4 μm Cooling Peltier2-stage PeltierPeltier ↓Ambient -30 ℃ -45 ℃ -40 ℃ Megapixels Communication USB 2.0

QE value 2016/6/27 8 Dark Current : K12CH/K12CHS/K16C/K16CH Lower than 20 ℃ Ambient K12CH/K12CH S K16C/K16CH

KETA M Configuration KETA M KETA MLKETA MLX CameraK12 CHK12 CHSK16CH Motorized Filter Wheel555 MC100 LED (W/R/G/B)Standard MC100-1 (W/G/B/UV 365 nm)Option AS 100Option Standard Magic1D & Magic ChemiStandard CommunicationUSB 2.0 Thermal printerOption SELM Module 200Option Lens f1.4, mm 2016/6/27 9

Typical Application for KETA M Gel documentation Colony counting Microtiter plate imaging Spot density calculation Photographic imaging 1 D analysis Fluorescence detection Chemiluminescence detection Optional SELM 200 for live imaging 2016/6/27 10

Sample Detection 2016/6/27 11 Protein Coomassie Blue Silver Stain SYPRO Orange SYPRO Ruby SYPRO Red Fluorescein Q-Dot Nucleic Acid Ethidium Bromide SYPRO Green SYPRO Gold Texas Red Gel Star Chemiluminescent ECL, ECL Plus ECL Advance, ECL Plex CDP star, Q-dot Super signal CSPD

Applications 2016/6/27 12 SYBR Green I stain: KETA M KETA ML Excited with: 312 nm Trans-UV, Filter: WK102 Excited with: 312 nm Trans-UV, Filter: WK105 SYPRO Red stain:

Chemiluminescence Experiment 2016/6/27 13 Sample: β-actin in MCF7 cell lysate Image model: ML Stain: plus-ECL (Perkin Elmer) Exposure time: 20 seconds Binning: Off Sample: GST pure protein Image model: ML Stain: ECL Enhanced (Millipore) Exposure time: 20 seconds Binning: Off (A) (B)

KETA M system: High performance gel doc and good sensitivity of Chemi detection. KETA ML system: 2-stage Peltier cooled system provides best cooling effect for the camera. ↓ noise, ↑performance.  Most profitable systems for sale. KETA MLX system: Truly 16 bits CCD with 4.2 Megapixels provides the best observation on both Chemi- and Fluor- detection. 2016/6/27 14

Specs to defeat competitors AS 100 sample stage 1. Easy for adjust the height of sample 2. Clear in focusing 3. Change samples fast and easy 4. Prevent cross contamination 5. Easy to enlarge the observation area 2 nd stage Peltier camera 1. Cheapest among the same level image systems 2. Absolute low temperature 3. Low noise 4. High S/N ratio 5. Good Chemi detection ability Upgradeable to live imaging system 2016/6/27 15

2016/6/27 16Magic1D Controls Dolphin series and KETA series, respectively

Features of 1D software Easy image capturing Multiple file format supported: JPG, BMP, JPEG, DFN, TIFF, PCX, GIF, TGA image Automatic data analysis (Within 1 minute) Traceable image enhancement function Intelligent colony counting Comprehensive microtiter plate analysis Accurate spot density calculation 3-D display image profile Support GLP/GMP Image blending function 2016/6/27 17

2016/6/27 18 Magic Chemi Software Enhancing on Image Capturing Tools Image capture control panel Batch capture for different exposure time DynaView capture function for accumulate multi-exposure signal Force cooling design ensure the best S/N ratio Darkroom calibration eliminate all undesired noise from the cabinet Binning and Gain function for hard-detectible signal

2016/6/27 19 Image Capturing Batch Capture: Allow users to select the best-desired image with optimal exposure time from the captured set. Time pic1 pic2 pic3 Exposure Time DynaView: Allow users to accumulate the multi capture signal with same exposure time. Time pic1 pic2 pic3 Exposure Time + + +

2016/6/27 20 Gel image analysis: DNA agarose gel, sequencing gel, blotting membrane, Protein SDS-PAGE gels, X-Ray film and photo etc. –Lane profile with lane image alignments –Ability to identify smiling gel accurately –Specialized X-axis band analysis function –Precise sample info report

2016/6/27 21 Colony counting: -Auto colony counting -intelligent colony distinguish Microtiter plate assay: Includes 48, 96, 384, 1536 wells micro-plate assay and various dot-blot and slot-blot formats.

2016/6/27 22 Spot image analysis: Suitable for irregular shape sample analysis, including 2-D gel sample and other special purpose assays.

Thank you!! 2016/6/27 23