F.Murtas G.Claps, E.Baracchini 1 EDIT FrascatiOctober 22 h 2015 GEMPIX detectors : GEM with higly pixelated readout Introduction GEMPIX Detectors GEMPIX.

Slides:



Advertisements
Similar presentations
Triple-GEM detector operation for high-rate particle triggering W. Bonivento, G. Bencivenni, A. Cardini, C. Deplano, P. de Simone, F. Murtas, D. Pinci,
Advertisements

GEM Chambers at BNL The detector from CERN, can be configured with up to 4 GEMs The detector for pad readout and drift studies, 2 GEM maximum.
F.Murtas1 Frascati February 5 th 2013 Triple GEM detectors : application on plasma diagnostics and neutron detection. Principia of triple GEM detector.
Beam tests of Fast Neutron Imaging in China L. An 2, D. Attié 1, Y. Chen 2, P. Colas 1, M. Riallot 1, H. Shen 2, W. Wang 1,2, X. Wang 2, C. Zhang 2, X.
Beijing, August 18, 2004 P. Colas - Micromegas for HEP 1 Recent developments of Micromegas detectors for High Energy Physics Principle of operationPrinciple.
GEM Detector Shoji Uno KEK. 2 Wire Chamber Detector for charged tracks Popular detector in the particle physics, like a Belle-CDC Simple structure using.
SOIPD Status e prospective for 2012 The SOImager2 is a monolithic pixel sensor produced by OKI in the 0.20 µm Fully Depleted- Silicon On Insulator (FD-SOI)
RF test of the GEM detector prototipe Detector description RF test area (LINAC3) detector working conditions RF field measurement Detector measurements.
Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck.
PRODUCTION and CERTIFICATION of Multi Wires Proportional Chambers for the LHCb Muon System at CERN K.Mair for the LHCb Muon Group CERN* Poster anlässlich.
TPC for 2p radioactivity studies Bertram Blank, CENBG.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
Something about Institute of Automatics, neutron generators and radiation hardness Institute of Automatics, Neutron Generators, Detectors and Radiation.
INTRODUCTION : Imaging antiprotons INTRODUCTION : Imaging antiprotons First results of real time imaging of the high energy gamma rays coming from antiproton.
Gain measurements of Triple Gas Electron Multiplier (GEM) detector with zigzag readout strips V. BHOPATKAR, E. ESPOSITO, E. HANSEN, J. TWIGGER M. HOHLMANN.
2012 IEEE Nuclear Science Symposium Anaheim, California S. Colafranceschi (CERN) and M. Hohlmann (Florida Institute of Technology) (for the CMS GEM Collaboration)
G.Bencivenni LNF/INFNMuon Meeting 21-October-2002 Status Report on triple-GEM detector M.Alfonsi 1, G. Bencivenni 1, W. Bonivento 2,A.Cardini 2,C. Deplano.
SPHENIX GEM Tracker R&D at BNL Craig Woody BNL sPHENIX Design Study Meeting September 7, 2011.
Neutron Structure Functions and a Radial Time Projection Chamber The Structure of the Neutron The BoNuS Experiment at CLAS A New Proton Recoil Detector.
Detector R&D for Muon Chamber Anand K. Dubey For VECC group.
in external photon beam radiotherapy
Neutron scattering systems for calibration of dark matter search and low-energy neutrino detectors A.Bondar, A.Buzulutskov, A.Burdakov, E.Grishnjaev, A.Dolgov,
Munich-Centre for Advanced Photonics A pixel detector system for laser-accelerated ion detection Sabine Reinhardt Fakultät für Physik, Ludwig-Maximilians-Universität.
Test Beam the μ-RWELL Test Beam the μ-RWELL G. Bencivenni (a), R. de Oliveira (b), M. Gatta (a), G. Felici (a), G. Morello (a), M. Poli Lener (a) (a),
Geant4 Simulation of Neutrons interaction with GEM-foil and gas Gabriele Croci, Matteo Alfonsi, Serge Duarte Pinto, Leszek Ropelewski, Marco Villa (CERN)
TPC R&D status in Japan T. Isobe, H. Hamagaki, K. Ozawa, and M. Inuzuka Center for Nuclear Study, University of Tokyo Contents 1.Development of a prototype.
Energy calibration of the threshold of Medipix for ATLAS Céline Lebel Université de Montréal presenting for the Institut of Experimental.
EPS-HEP 2015, Vienna. 1 Test of MPGD modules with a large prototype Time Projection Chamber Deb Sankar Bhattacharya On behalf of.
INFN – SEZIONE DI MILANO-BICOCCA People 1 Section Director: Dr. D. Pedrini Group Leader: Prof G. Gorini Associated researchers/Post-docs/PhD Students Prof.
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger,
F.Murtas1IMAGEM DDG GEM technology for X-ray and Gamma imaging IMAGEM l Detector setup l First results on X-ray imaging l First results on Gamma ray imaging.
A. Muraro 1, G. Croci 1,2, C. Cazzaniga 3, G. Claps 4, M. Cavenago 5, G. Grosso 1, F. Murtas 4,6,, E. Perelli Cippo 1, M. Rebai 2,3, R. Pasqualotto 7,
F.Murtas1 Zaragoza July 3 rd 2013 Micro Pattern Gas Detector 2013 Applications of MPGD beyond particle and nuclear physics A triple GEM detector system.
Preliminary results of a detailed study on the discharge probability for a triple-GEM detector at PSI G. Bencivenni, A. Cardini, P. de Simone, F. Murtas.
Performance and applications of a  -TPC K. Miuchi a†, H. Kubo a, T. Nagayoshi a, Y. Okada a, R. Orito a, A. Takada a, A. Takeda a, T. Tanimori a, M. Ueno.
He-free Side-on GEM detector for thermal neutron counting
F.Murtas1 CNAO- ARDENT Workshop October 19 th 2012 Triple GEM detectors : Beam monitoring for beam profile and intensity measurements. Construction of.
you me  when it all started to work  progress made  outlook.
Plans for MPGD Radiation hardness tests for full detectors and components Matteo Alfonsi,Gabriele Croci, Elena Rocco, Serge Duarte Pinto, Leszek Ropelewski.
TPC/HBD R&D at BNL Craig Woody BNL Mini Workshop on PHENIX Upgrade Plans August 6, 2002.
1 GEM R&D Activity in USTC Yi Zhou University of Science & Technology of China.
Test of the GEM Front Tracker for the SBS Spectrometer at Jefferson Lab F. Mammoliti, V. Bellini, M. Capogni, E. Cisbani, E. Jensen, P. Musico, F. Noto,
18 October 2013 TRAINING COURSE ON RADIATION DOSIMETRY: Micro Dosimetry with GEM (Gas Electron Multiplier) and GEMpix F. Murtas, CERN-INFN.
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
F.Murtas1 LUMI GEM Bremsstrahlung Dafne Bhabha Dafne Upgrade.
Quality control for large volume production GEM detectors Christopher Armaingaud On behalf of the collaboration GEMs for CMS.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
Construction and Characterization of a GEM G.Bencivenni, LNF-INFN The lesson is divided in two main parts: 1 - construction of a GEM detector (Marco Pistilli)
F.Murtas, INFN LNF – INFN-E project D.Pacella, Enea Frascati
FrontierScience G.P.1 MATRIX an innovative Pixel Ionization Chamber for Online Monitoring of Hadrontherapy Treatments Giuseppe Pittà.
J. Alozy, S. George, F.Murtas, M. Silari 1 CERN GEMPIX detectors as hadron therapy beam monitors and radioactive waste detectors GEMPIX construction.
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
14/02/2008 Michele Bianco 1 G.Chiodini & E.Gorini ATLAS RPC certification with cosmic rays Università del Salento Facoltà di Scienze MM.FF.NN.
F. Murtas CERN-INFN Frascati December 2 th 2013 – He3 free detectors Italy Workshop 1 Front End Electronics for GEM detector  Neutron detectors and GEM.
GEM gas detectors for Soft X-ray imaging in Fusion devices with neutron-gamma background and polycapillary lenses F. Murtas 2, S. Dabagov 2,4, L. Gabellieri.
Gossip : Gaseous Pixels Els Koffeman (Nikhef/UvA) (Harry van der Graaf, Jan Timmermans, Jan Visschers, Maximilien Chefdeville, Vladimir Gromov, Ruud Kluit,
TPC for ILC and application to Fast Neutron Imaging L. An 2, D. Attié 1, Y. Chen 2, P. Colas 1, M. Riallot 1, H. Shen 2, W. Wang 1,2, X. Wang 2, C. Zhang.
He-free GEM detector for thermal neutron counting
Triple GEM detectors : measurements of stray neutron.
Johannes Leidner, Fabrizio Murtas, Marco Silari
A GEM-BASED DETECTORS FOR BEAM MONITOR AND NEUTRON FLUXES DIAGNOSTICS
The Pixel Hybrid Photon Detectors of the LHCb RICH
Development of Gas Electron Multiplier Detectors for Muon Tomography
Development of GEM at CNS
GEM-based neutron detectors including beam monitors
Pre-installation Tests of the LHCb Muon Chambers
Beam Monitors with GEM detectors
Gain measurements of Chromium GEM foils
A DLC μRWELL with 2-D Readout
Presentation transcript:

F.Murtas G.Claps, E.Baracchini 1 EDIT FrascatiOctober 22 h 2015 GEMPIX detectors : GEM with higly pixelated readout Introduction GEMPIX Detectors GEMPIX Applications Measurements: gain and drift velocity F.Murtas, G.Claps, E. Baracchini Laboratori Nazionali Frascati - INFN A.Balla, G.Claps, G.Corradi, G.Croci, E.Baracchini, D.Tagnani, D.Pacella A.Balla, G.Claps, G.Corradi, G.Croci, E.Baracchini, D.Tagnani, D.Pacella

F.Murtas G.Claps, E.Baracchini 2 EDIT FrascatiOctober 22 h 2015 A triple GEM Chamber GEM foil 70 µm140 µm A Gas Electron Multiplier (F.Sauli, NIM A ) is made by 50  m thick kapton foil, copper clad on each side and perforated by an high surface-density of bi-conical channels; Several triple GEM chambers have been built in Frascati in the LHCb Muon Chamber framework* Working with different levels of gain it is possible to obtain high level of gamma- neutron discrimination

F.Murtas G.Claps, E.Baracchini 3 EDIT FrascatiOctober 22 h 2015 Main Characteristics The main characteristics are : - Extended dynamic range (from single particle up to 10 8 partcles cm -2 s -1 ) - Good time resolution (5 ns) - Good spatial resolution (200  m) - Radiation hardness (2C/cm 2 ) Thanks to these characteristics a GEM detector can be used for: - plasma imaging for fusion reactors (tokamak) neutron and X rays, - diagnostics for beam particles (high energy physics, hadron therapy) - detectors for fast and thermal neutrons, - medical applications (diagnostics and therapy): - medical diagnostics medicale in gamma therapy; - medical diagnostics in hadro therapy; - steress diagnostics in industrial applications; - environment monitoring; - radioactive waste imaging;

F.Murtas G.Claps, E.Baracchini 4 EDIT FrascatiOctober 22 h 2015 GEMpix Assembling Quad medipix board The detector has two main parts : - The quad medipix with a naked devices - The triple gem detector with HV filters and connector New HV GEM board Top view M.Campbell, J.Alzoy 2.8 cm

F.Murtas G.Claps, E.Baracchini 5 EDIT FrascatiOctober 22 h 2015 Head on detector Gas flux AR CO 2 The detector is a quad naked medipixes (no silicon sensor): The active area is 9 cm 2 Triple GEM Mylar window Particles to be analysed 3 mm ionization gap This type of device can be used for high flux of X rays Gain tuneable from 1 up to 10 4 Time resolution: 5 ns Energy sensitivity few keV

F.Murtas G.Claps, E.Baracchini 6 EDIT FrascatiOctober 22 h 2015 Side on detector Gas flux The detector is a quad naked medipix : The active area is 9 cm 2 The particle track is analysed with 512 pixel in 3 cm length The longest drift gap used up to now is 5 cm. Triple GEM Kapton window Particles to be analysed Length analysed

F.Murtas G.Claps, E.Baracchini 7 EDIT FrascatiOctober 22 h 2015 GEMPIX readout TOA Wilkinson ADC

F.Murtas G.Claps, E.Baracchini 8 EDIT FrascatiOctober 22 h 2015 GEMPIX detectors and HV HVGEM Side-on (2 cm drift) Head-on TPC (5 cm drift)

F.Murtas G.Claps, E.Baracchini 9 EDIT FrascatiOctober 22 h 2015 GEMPIX applications Gempix Detector (10cm 2 GEM detector read by 55x55  m pixels, channels ) - radioactive CERN waste 55Fe measurements (LEP, SPS, etc) - 3D measurements of energy released in water phantom in hadrotherapy treatment facility (CNAO Pavia) - Gamma ray monitor for radiotherapy dose measurement (Polic.Tor Vergata Rome) - X ray monitor in Inertial Fusion test facility (Petal, France ) - X ray monitor in KSTAR Tokamak reactor (Korea) - Proton tomography prototypes (Nikef, Nederland) - Dark matter prototype for Directional dark mattersearches with carbon nanotubes - Dark matter prototype for NITEC: a Negative Ion Time Expansion Chamber for directional Dark Matter search Hadrotherapy Radiotherapy: GEMPIX vs radiochromic film 3D reconstruction

F.Murtas G.Claps, E.Baracchini 10 EDIT FrascatiOctober 22 h 2015 GEMPIX for Fusion Laser Produced Plasmas (ABC, ENEA) Tokamak Plasmas (KSTAR, South Korea) A frame every 700 ms Laser pulse duration = 3 ns Wavelenght = 1054 nm A maximum energy of 100 J per pulse

F.Murtas G.Claps, E.Baracchini 11 EDIT FrascatiOctober 22 h 2015 GEMpix detector and EBT gafcromic comparison through γ test: the bi-GEM configuration 8x8 mm 2 irradiating field 6 MV γ < 1, % 6 MV γ < 1, % 6 MV γ < 1, % Multileaf collimator

F.Murtas G.Claps, E.Baracchini 12 EDIT FrascatiOctober 22 h 2015 Phantom used at CNAO Bragg Peak finder at CNAO Thin Window Gempix Stepper Motor Several measurement of energy deposition along the beam (5x10 8 Carbon ions per 10 spills)

F.Murtas G.Claps, E.Baracchini 13 EDIT FrascatiOctober 22 h D reconstruction Energy deposition in hadrotherapy

F.Murtas G.Claps, E.Baracchini 14 EDIT FrascatiOctober 22 h 2015 GEMPIX for radioctive waste X-ray candidates Bkg GEMPIX 1 hour of data acquisition Medipix 10 hours of data acquisition External companies : days Very good pattern recognition and particle identification Correlation between GEMPIX and Medipix Data acquired in one second

F.Murtas G.Claps, E.Baracchini 15 EDIT FrascatiOctober 22 h 2015 GEMPIX as Negative Ion TPC for directional Dark Matter searches J. Martoff et al., NIM A < 0.5 mm diffusion achieved over 50 cm drift length w.r.t. 10 mm obtained with electrons (no magnetic field) --Larger allowed drift length thanks to negative ion suppressed diffusion --3D track reconstruction and head-tail discrimination capability thanks to time & charge GEMPIX measurements --Improved position and energy resolution thanks to possibility of single ionization cluster measurement Cluster structure clearly visible

F.Murtas G.Claps, E.Baracchini 16 EDIT FrascatiOctober 22 h 2015 Measurements at EDIT 2015 Cosmic Rays in TOT mode cluster analysis Gain measurements with 55Fe source Drift Velocity Measurements with the BTF eleectron Beam pixelman FITPIX DAQ interfac FITPIX DAQ interfac HVGEM GEMPIX Online display Online plots HV Control

F.Murtas G.Claps, E.Baracchini 17 EDIT FrascatiOctober 22 h 2015 The GEMPIX TPC 70 counts 7 us... 5 cm 3D reconstruction

F.Murtas G.Claps, E.Baracchini 18 EDIT FrascatiOctober 22 h 2015 X Ray Source spectrum 4 points at 1300, 1260, 1220, 1180 V 55 Fe HV Value Mean charge G eff = A e α(Vgem1+Vgem2+Vgem3) A and α depend on the gas mixture.

F.Murtas G.Claps, E.Baracchini 19 EDIT FrascatiOctober 22 h 2015 Online measurements Start with trigger end 10 us Single frame of 3 usBeam

F.Murtas G.Claps, E.Baracchini 20 EDIT FrascatiOctober 22 h 2015 Drift velocity measurement X projection Y projection Z projection Z position Drift Time