UtilitySaver Overview. PREFERRED UTILITIES MFG CORP 31-35 South St. Danbury CT T: (203) 743-6741 F: (203) 798-7313 www. PREFERRED-MFG.com.

Slides:



Advertisements
Similar presentations
PPC4000 COMBUSTION EFFICIENCY SYSTEM
Advertisements

Variable Frequency Drives Bypass Options
Preferred Instruments CB-Hawk Replacement System Based on BurnerMate TS Technology A low-cost upgrade for obsolete CB-Hawk systems.
Preferred Utilities Manufacturing Corporation. q Introduction q Architecture q Communication Networks q Operation Workstation q Summary Preferred Utilities.
Preferred Utilities Manufacturing Corp
Preferred Utilities Manufacturing Corp
Preferred Utilities Manufacturing Corp
BurnerMate TS Overview
Preferred Utilities Manufacturing Corp
MEDIUM VOLTAGE VFD MOTOR CONTROLLER Liquid Cooled Components Active Front End - No Transformer 3300 – 6900 VAC 700 – 2500 HP Contact:
MAGNA3 – “built on a proven foundation”
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
ABB standard drive Enhanced ACS550
Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
Who is Stellar Tech?  Stellar Tech Energy Services is a wholly owned Canadian company  Manufacturer of WellMax Datalogger / Controller  Specializing.
HYDRAULICS & PNEUMATICS
BurnerMate Universal A Complete Boiler Control System.
Variable Frequency Drives VFD Basics
Heating Control Devices
SPEED CONTROL OF THREE PHASE INDUCTION MOTOR WITH ENERGY SAVING
WISA Meeting Help Arrange a Speaker, Write Bio, Introduce
Product Introduction.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
1 BARRY DUNGEY General Manager Engineering & Maintenance June 2008 Loy Yang Power Station Control System Upgrade.
Copyright © 2008 Rockwell Automation, Inc. All rights reserved. Direct-to-Drive Technology Product Feature Overview.
InnovationValueTeamwork SHENZHEN INVT ELECTRIC CO., LTD.
BOILER PLANT OPERATION Presented By Mr. Sivanand Ray
Industrial Electrical Engineering and Automation Structures of the Energy flow system Mechatronics 2007.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
PWC Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
Variable Frequency Drives and Irrigation Pumps Stefanie Aschmann Bozeman, MT 11/30/11 1.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
World Leaders in Combustion Management Solutions Taiwan introduction.
New Product Developments World Leaders in Combustion Management Solutions Mk7 Expansion PCB Mk7 Expansion PCB.
Roof Top Unit Overview (MAGNUM) Visit us at Revision- 12/17/2015.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
Intelligent Boiler Sequencing
CUE – Make Any Pump an E-Pump
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
Energy Saving Measures - 1
Standards Certification Education & Training Publishing Conferences & Exhibits Automation Connections ISA EXPO 2006.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
I Need A Space Heating System Let’s Look At A Central Steam Plant Option.
Lancom 4 In Power and Boilers Derek Stuart. Lancom 4 In Power and Boilers Derek Stuart Combustion Theory In order to maximize the heat capture (efficiency)
PREFERRED UTILITIES MFG CORP South St. Danbury CT T: (203) F: (203) www. PREFERRED-MFG.com.
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
TYPE “HOS” 6” Stroke Compressor & Ancillary Equipment
 2008 Kaeser Compressors, Inc., USA (V4.1) SFC Product Introduction “Specifications are subject to change without notice” 1 SFC Sigma Frequency Controlled.
Solar Pumps- High profitability and reliability lead to prosperity.
PREFERRED UTILITIES MFG CORP South St. Danbury CT T: (203) F: (203) www. PREFERRED-MFG.com.
BurnerMate TS Overview. PREFERRED UTILITIES MFG CORP South St. Danbury CT T: (203) F: (203) www. PREFERRED-MFG.com.
PREFERRED UTILITIES MFG CORP South St. Danbury CT T: (203) F: (203) www. PREFERRED-MFG.com.
World Leaders in Combustion Management Solutions OverviewExplanationFurther Information Application Further Information Explanation Introduction Application.
VFD Basics and the Tower IQ June 10 th, The Rundown  Cerus Overview  VFD Basics  VFD Applications and Packages  Cooling Tower IQ  Questions.
Integrated Blower Packages Kaeser Integrated Blower Family.
Reliability in motion ™ Copyright © 2010 Toshiba International Corporation. All rights reserved Welcome.
Unit 13 Oil-Burning Equipment
The New C55* CPVSd 10-20hp People. Passion. Performance.
Speed control of three phase induction motor
Yaskawa Electric America on Variable Torque Loads
SPOC Automation and BECI- who are we?
Robicon Perfect Harmony.
Loop Water Controller Overview
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
ACOE347 – Data Acquisition and Automation Systems
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
Presentation transcript:

UtilitySaver Overview

PREFERRED UTILITIES MFG CORP South St. Danbury CT T: (203) F: (203) www. PREFERRED-MFG.com

UtilitySaver Burner Control  Introduction  Energy Savings  Fuel Savings  Electrical Savings  System Composition  UtilitySaver Panel  Oxygen Analyzer  Actuators  Variable Frequency Drive  Installation  Summary

UtilitySaver Burner Control. The UtilitySaver tm uses a single PCC-III Controller to provide state of the art burner control. The package includes firing rate control with both oxygen trim and variable speed fan combustion air flow control. UtilitySaver fuel and electrical savings can pay for the installed system in two years.

UtilitySaver Burner Control

Includes:  UtilitySaver Panel  Oxygen Analyzer Kit  Boiler Efficiency Kit  Actuator Kit  Jackshaft and UtilitySaver Damper  Variable Frequency Drive (VFD) Kit  Installation Materials and Supervision!

UtilitySaver Burner Control  Introduction  Energy Savings  Fuel Savings  Electrical Savings  System Composition  UtilitySaver Panel  Oxygen Analyzer  Actuators  Variable Frequency Drive  Installation  Summary

Energy Savings Fuel Savings Electrical Savings +

Energy Savings Fuel Savings:  Seasonal Air Density and Humidity Changes  Fuel Pressure and Temperature Changes  Fuel Btu and Viscosity Variations  Worn Linkage Components (Hysteresis) Electrical Savings:  Minimizing Damper Pressure Drop - damper is 100% open for maximum kWh savings, (Partially closed at low fire to maximize burner turndown)  Oversized Fans  Oversized Motors  Partially Loaded Boilers

Energy Savings Based on:  ASME “by losses” boiler efficiency calculations.  Industry leading manufacturer motor energy data.  600 Bhp Boiler  125 psi Steam  Natural gas fired  Operating 365 days / year & 24 hours / day  Electric Cost cents / kWh  Fuel Cost - $4.5/k ft3  Oxygen Reduction - 1.5% Wet Conservative $13,700 per Year

Unique Energy Savings Tool Savings Estimate Based on:  Boiler size  Motor HP  Air Damper Type  Current O2 Level  Projected O2 Level  Flue Gas Temperature  Seasonal Loading Data  Fuel Cost  Electrical Cost

Fuel Savings

Variations in Air Composition  “Standard” air has LB. O 2 per FT 3  Hot, humid air has less O 2 per cubic ft  20% less at 95% RH, 120 O F, and 29.9 mm Hg  Dry, cold air has more O 2 per cubic ft  10% more at 0% RH, 32 O F, and 30.5 mm Hg  Standard Combustion controls must:  Allow at least 20% extra excess air because of the change in air density.

Variations in Air Composition

At these ambient conditions the burner has extra O 2 & N 2

Combustion Air Fan Hp Savings Combustion Air Flow, %Full Load Motor Power(HP) Input, % Full Load Variable Speed Control Damper Control HP Savings

UtilitySaver Burner Control  Introduction  Energy Savings  Fuel Savings  Electrical Savings  System Composition  UtilitySaver Panel  Oxygen Analyzer  Actuators  Variable Frequency Drive  Installation  Summary

UtilitySaver Burner Control

The UtilitySaver Controller Right For the Job...

The UtilitySaver Panel Measured Flue Gas Oxygen Setpoint Organized, simple and to the point local operation Firing Rate % (shown) Steam PSIG Steam PSIG SP Oxygen % Oxygen SP Oxygen Trim % VFD Speed Fuel Valve Position Air Damper Position Boiler Efficiency Firing Rate

The UtilitySaver Panel  Enclosure -  Nema 12, 16 H x 14 W x 10 D  Controller -  PCC-III with “Z”, and “G” Option Boards.  Components -  VFD / Flame Safeguard interface relays  24Vac power supply transformer for DM-1E Actuators  Shielded cable for field wiring

The UtilitySaver Controller  PCC-III-ZG00  “Z” Option Board, Oxygen Analyzer  “G” Triac Outputs to Drive Electric Actuators  Constructed For Boiler Front Mounting  Intuitive Operation  Flexible, powerful blockware control logic  Built In Boiler Efficiency  F(x) Characterizers with “Learn” Mode  Commissioning Tools

UtilitySaver Features  Minimizing Damper Pressure Drop  Damper is 100% open for maximum kWh savings, (Partially closed at low fire to maximize burner turndown)  Fuel-Air Lead-Lag With Cross-Limiting  On a load increase, Air increases first. On a load decrease, Fuel decreases first.  Minimizes excess air during normal firing, and increases excess air during a load change for safety.  Excess air is limited during load changes for flame stability.

UtilitySaver Features  Independent Fuel-Air Ratio Curves  PCC-III "Learn" mode  Rapid, error free burner fuel-air ratio curve setup, with easy "Store" pushbutton operation.  Safety  Low flue gas oxygen trips the burner after an adjustable time delay.  VFD speed and actuator position feedbacks are continuously monitored. Burner trips after an adjustable time delay if any are out of position.  Real Time Boiler Efficiency  Continuous Oxygen Analyzer Diagnostics

Touch Screen Options 10 inch

In-Situ Oxygen Analyzer No separate analyzer, one less item to mount Field replaceable detector Only one conduit to stack.

In-Situ Oxygen Analyzer  Proven Reliable  Zirconia Oxide Sensor  No Reference Air  The probe uses ambient air as a reference.  Competitors use instrument air and run the risk of element cracking due to water  Automated, menu driven pushbutton calibration.  Automatic impedance checking  Alarms when time to recalibrate

Oxygen Analyzer Kit q Model ZP Oxygen Sensor, 20” Standard q Reliable Zirconia Oxide Cell q 60 ft ZP Cable q Mounting Hardware included

Boiler Efficiency Kit  PCC-III Controller calculates the ASME “by losses” method efficiency in real time. Kit Includes:  Flue Gas Temperature Assembly, Type J, p/n C, with mounting flange  60 feet of shielded type J T/C extension cable

Actuator Kit  Torque: 150 in-lbs  Rotation:90° travel in 30 seconds  Aux. Switches:Integral 2 SPDT  Position Feedback: 600 ohm  Power Supply:24 Vac  (2)Linkages, (3)Lever Arms, (1)Mounting Bracket Two (2) DM-1E Actuators are Included: Jackshaft & Damper

Alternate Actuators  R-AL : 100 lb Linear Thrust  1730: 1000 in-lb Torque  UP10 Pneumatic: 1080 in-lb Torque  I/P Kit to interface to Existing Pneumatic Jackshaft Actuator  Pot Box, if Existing Actuator doesn’t have Feedback

Variable Speed Fan Air Flow Control  Variable Speed Drive (VSD) - The UtilitySaver package includes a full featured, quality drive.  Nema 12 Packaging - for worry free boiler room installation  Built in “DC Link” line reactor - for reduced electrical system harmonics distortion  “Soft Turn On” IGBT transistors - for reduced motor stress (lower peak voltages)

VSD Parts & Theory 5 Parts to a VSD  Rectifier  DC “Link” line reactor  Intermediate Circuit  Inverter (IGBT = Insulated Gate Bipolar Transistor)  Control & Regulation

Motor Speed Control

Pulse Width Modulation (PWM)  On or Off, voltage does NOT modulate.  PWM allows IGBT’s to run cool for long life, so better VSD’s use PWM.  However, PWM dV/dt causes spike voltages

“Soft Turn On” IGBTs  dv/dt - Change in Voltage over Time  Competitor’s Drives - up to 3500V/us  UtilitySaver Drive - 900V/us  Due to Patented “Soft Turn On” IGBT’s  Lower Peak Voltages Extend Motor Insulation Life  460V, 75 Hp motor:  815V peak for 50 ft cable

Automatic Over Ramp Protection  The UtilitySaver VFD will not trip when given a “STEP” speed increase of 0 to 100 %  The drive automatically limits the rate of fan speed increase to that which will prevent an over current trip.  Other drives do not have this feature. Other drives may trip if the speed is increased too quickly.

UtilitySaver Burner Control  Introduction  Energy Savings  Fuel Savings  Electrical Savings  System Composition  UtilitySaver Panel  Oxygen Analyzer  Variable Frequency Drive  Actuators  Installation  Summary

UtilitySaver Installation  Sole Source Responsibility  Locate all device mounting locations  Install Oxygen Sensor & Flue Gas T/C.  Install and adjust damper linkage, and stroke actuators.  Run conduit and wire to field devices, existing motor starter, motor and control panels.  Commission UtilitySaver package for optimum burner performance  Train Owners Operators for proper operation

UtilitySaver Installation

UtilitySaver Burner Control  Introduction  Energy Savings  Fuel Savings  Electrical Savings  System Composition  UtilitySaver Panel  Oxygen Analyzer  Actuators  Variable Frequency Drive  Installation  Summary

Experience Preferred Instruments has 25 years of Combustion Control Experience with…  A Third Generation Digital Controller  Over 1000 Boiler Control System Installations  2400 PCC II/III Controllers Installed Exclusively in Combustion Control Applications  45 SCADA/Flex Projects  640 Burner Projects

Experience Compatible with other products from Preferred Instruments...  SCADA/Flex Remote Operator Stations  BMS Logic+ Burner Management Systems  Boiler Sequencing, Lead / Lag Systems  Feedwater Control Systems  Draft Control Systems  Balance Of Plant (BOP) Systems

Summary UtilitySaver …...  Excellent Annual Savings  Savings from Both oxygen trim and variable speed fan combustion air flow control  Field proven and feature rich PCC-III Controller  Backed by over a thousand package boiler control installations  Single Source Responsibility  Complete Material and Installation

Factory Sales Offices located throughout the U.S., supported by sales representative organizations. PREFERRED UTILITIES MFG CORP