Copyright 2007, Toshiba Corporation. Prospects of X-band Klystron Based on Experience of High Power Klystron Development in TETD 31 st /Jan./2013 Toshiba.

Slides:



Advertisements
Similar presentations
X Band Vacuum Devices Presented by: Tony Johns,
Advertisements

Jiaru Shi Department of Engineering Physics, Tsinghua University CLIC Workshop 2013 Accelerator Activities at Tsinghua University.
Areal RF Station A. Vardanyan RF System The AREAL RF system will consist of 3 RF stations: Each RF station has a 1 klystron, and HV modulator,
KAGEYAMA, T. Open Meeting for Proto-Collaboration March 19, 2008.
PEP Super-B High Power RF Peter McIntosh SLAC Super-B Factory Workshop in Hawaii April 2005 University of Hawaii.
1 X-band Single Cell and T18_SLAC_2 Test Results at NLCTA Faya Wang Chris Adolphsen Jul
A. Baikov (MUFA), I. Syratchev (CERN), C. Lingwood, D
Before aperture After aperture Faraday Cup Trigger Photodiode Laser Energy Meter Phosphor Screen Solenoids Successful Initial X-Band Photoinjector Electron.
MuCool RF Status MICE Collaboration Meeting June 7-10, 2006, Fermilab A. Moretti June 9, 2006.
THALES ELECTRON DEVICES
1.0 MW / 175 MHz Source for IFMIF: a study of alternatives
2009/3/3US High Gradient Research Collaboration Workshop 1 Design Studies of an X-band Multi- beam Klystron S. Fukuda KEK Accelerator Laboratory, KEK.
Microwave semiconductor devices
Thales Components & Subsystems
1 C-Band Linac Development Satoshi Ohsawa 2004.Feb.19LCPAC.
Visits to Chinese accelerator companies Peter Pearce (April 2004) Two companies were visited. Beijing Medical Equipment Institute at Chongping and Beijing.
Multiple Beam Klystrons for Accelerators and Collider
X-Band RF Power Sources for Accelerator Applications
Design Status of IOT for ILC
February 17-18, 2010 R&D ERL Alex Zaltsman R&D ERL High Power RF Systems Alex Zaltsman February 17-18, 2010 High Power RF Systems.
Vacuum Electron Device Limitations for High-Power RF Sources Heinz Bohlen, Thomas Grant Microwave Power Products Division CPI, Palo Alto 1.
I. Syratchev, April 2015, EuCARD2, Barcelona. Review of Efficient RF Sources I. Syratchev, CERN.
NEW DRIVERS FOR FUTURE LINEAR COLLIDERS SEVENTEENTH LOMONOSOV CONFERENCE ON ELEMENTARY PARTICLE PHYSICS Moscow, August , 2015 Ivan Spassovsky Laboratory.
13 th Advanced Accelerator Concepts Workshop. Santa Cruz, July 27-August 2, 2008 Seventh-Harmonic Multi-MW K-band Frequency Multiplier: Rf Source for for.
CLIC meeting, Prospects for developing new tubes I. Syratchev, CERN.
CLIC Project meting #16. June 2014 I. Syratchev High efficiency power sources I. Syratchev, CERN.
L-band (1.3 GHz) 5-Cell SW Cavity High Power Test Results Faya Wang, Chris Adolphsen SLAC National Accelerator Laboratory
The selection of operating mode for 10MW L-band MBK with high efficiency Institute of Electronics, Chinese Academy of Sciences Beijing, China November.
Topical workshop on The Neutrino Factory and Muon Collider Oct 2007 RF Systems for a Neutrino Factory Rebecca Seviour Cockcroft Institute Lancaster University.
RF scheme of electron linear accelerator with energy MeV Levichev A.E. Budker Institute of Nuclear Physics SB RAS.
Development of The Klystrons for J-PARC Project
CLIC Workshop, February, CERN. I. Syratchev Roadmap for CLIC high-efficiency klystron development I. Syratchev, CERN.
Harmonic Generation on the Multi- Frequency Recirculating Planar Magnetron S. C. Exelby, G. B. Greening, N. M. Jordan, D. Simon, P. Zhang, Y.Y. Lau and.
MP - HIPPI General meeting, Abingdon October 28-30, Side Coupled Linac Design at CERN Side Coupled Linac Design at CERN M. Pasini, Abingdon September.
KCS and RDR 10 Hz Operation Chris Adolphsen BAW2, SLAC 1/20/2011.
The US High Gradient Collaboration Vision for Research and Development on Ultra High Gradient Accelerator Structures Sami Tantawi, SLAC ( on behalf of.
Status of the 1.2 MW MB-IOT for ESS Morten Jensen CLIC Workshop 2016, January, CERN.
C/S band RF deflector for post interaction longitudinal phase space optimization (D. Alesini)
ALBA RF Systems Francis Perez.
20/3/2014 MEW weekly meeting Summary on high efficiency klystron design Chiara Marrelli.
PPM Focusing in Klystrons Michael Read Calabazas Creek Research Presented at CERN Aug 30, 2013
Doubly Convergent Multiple Beam Guns Lawrence Ives, Thuc Bui, Michael Read Calabazas Creek Research, San Mateo, CA. USA Adam Attarian, Billy Tallis, Cynthia.
X-band Based FEL proposal
Photocathode based Electron Sources for Particle Accelerators – Yesterday, Today and Tomorrow B.L. Militsyn STFC ASTeC, UK European Workshop on Photocathodes.
Nextef status and expansion plans Shuji Matsumoto for KEK Nextef Group /5/51 4th X-band Structure Collaboration Meeting, CERN.
Heung-Sik Kang Pohang Accelerator Laboratory
High-efficiency L-band klystron development for the CLIC Drive Beam High-efficiency L-band klystron development for the CLIC Drive Beam CLIC workshop,
BEAM ACCELERATION EXPERIMENT IN X-BAND GHZ LINAC FOR COMPTON SCATTERING X-RAY GENERATION Hirotoshi Masuda The University of Tokyo.
Areal RF Station A. Vardanyan
Prospects for developing new tubes
Multi-stage pulse compressor
How does a klystron work? TE-MPE Section Meeting Karolina Kulesz
Present and possible future schemes for hadron therapy linacs Alberto Degiovanni for the ADAM team HG2017 Workshop , Valencia.
High efficiency work and MBK development for accelerators
Development of high-power IOTs as an efficient alternative to klystrons Morten Jensen Energy for Sustainable Science 24 October 2013, CERN.
Prospects for high-efficiency klystrons
Thales Klystrons for Linacs
Development of X-band 50MW klystron in BVERI
with operating voltage
Application of moderate (5 MW) X-band power sources for the CLIC accelerating structures testing program and other projects I. Syratchev, CERN.
Application of the moderate peak power (6 MW) X-band klystron’s cluster for the CLIC accelerating structures testing program. I. Syratchev.
Klystron efficiency.
X-band Facilities and High Gradient Tests Stands Around the World
High Efficiency X-band Klystron Design Study
High Efficiency X-band Klystron Design Study
INEL 6069 Klystron A power amplifier tube used to amplify weak microwave energy (provided by a radio- frequency exciter) to a high power level for a radar.
CEPC RF Power Sources System
CEPC 650MHz Klystron Development
On the Korean Contributions for
CEPC RF Power Source System
Presentation transcript:

Copyright 2007, Toshiba Corporation. Prospects of X-band Klystron Based on Experience of High Power Klystron Development in TETD 31 st /Jan./2013 Toshiba Electron Tubes & Devices Co., Ltd. Kenichi Hayashi and Osamu Yushiro

2 Company overview Contents TOSHIBA MEDICAL SYSTEMS CORP. TOSHIBA ELECTRON TUBES & DEVICES CO.,LTD. 1.TETD (Toshiba Electron Tubes & Devices Co., Ltd.) 2.High-power pulsed klystron E3736H: L-band, 10 MW (long-pulse MBK) E3712: S-band, 80/100 MW E37202: C-band, 50 MW E3768: X-band, 50 MW 3.Promising or expected output power for X-band Scaling laws derived from electric field in output window and output cavity Performance of E3712, E37202, E3768 and XL-4 4.Summary

3 Company overview Electron Tube & Devices Works having Function from development to production “ To Be the Best Electron Tube & Divices Company ” TETD: Profile ■Name : Toshiba Electron Tubes & Devices Co.,Ltd. ◇ Established : October,1,2003 ◇ Headquarters : 1385 Shimoishigami Otawara-shi,Tochigi,Japan ◇ Tokyo office : Level 17A,1-1Shibaura 1Chome,Minato-ku,Tokyo,Japan ◇ Capital : 480 million yen ( Toshiba Medical Systems 100% ) ◇ President and CEO : Takashi Yanagawa ◇ Employees : 411 persons ◇ Operations : Development of an electron tube and an application product, manufacture, and sales ◇ Products : X-ray tubes, X-ray Image Intensifier, Klystron, Gyrotron, Grid tube, Magnetron, Monitor tube TOSHIBA MEDICAL SYSTEMS CORP. TOSHIBA ELECTRON TUBES & DEVICES CO.,LTD. Toshiba Electron Tubes & Devices

4 Frequency Repetition Rate Peak Power Pulse Length Beam Voltage Beam Current GHz 10.3 MW 1.5 ms 10 pps 117 kV 131 A Typical Operations Efficiency Gain 67% 50 dB E3736H: MBK (Multi Beam Klystron) Collector Electron gun Cavity Matching coil

5 Frequency Repetition Rate Peak Power Pulse Length Beam Voltage Efficiency GHz 80, 100 MW 4, 1  s 50 pps 400, 422 kV 42, 46% Typical Operations 1.9 m Accelerator Facilities KEK-ATF, SP-8, Osaka Univ., SAGA-LS, Tokyo Univ. of Science, AIST, PLS(KOREA), NSRL(China), etc. E3712 Total number of installed unit : 82 units S-band pulsed klystron

6 Frequency Repetition Rate Peak Power Pulse Length Beam Voltage Efficiency GHz 50 MW 2.5  s 60 pps 350 kV 47% Typical Operations E m Accelerator Facilities SACLA, PSI, INFN, etc. ★ 3-Cell Traveling-wave Output Cavity Total number of installed unit : 71 units C-band pulsed klystron

7 Frequency Repetition Rate Peak Power Pulse Length Beam Voltage Efficiency GHz 50 MW 0.5  s 50 pps 460 kV 46% Typical Operations Accelerator Facilities KEK-NEXTF, Tokyo Univ., etc. E m Total number of installed unit : 9 units X-band pulsed PPM klystron We found unstable phenomena that the after-part of RF pulse dropped out. RF break down in the output cavity or oscillation ?

8 UnitS-band E3712 C-band E37202 X-band XL-4 X-band E3768 FrequencyMHz Output powerMW8050 Pulse durationμs Beam perveanceμP Window type - Double- Standard Pill Box Double- Long Pill Box Double- TE01 mode Double- Mixed mode Output cavity type - single3-cell4-cell Front end klystron parameters for stable operation Issues for higher frequency and higher power klystron developments ・ Output window: puncture by higher electric field ・ Output cavity: RF breakdown by higher electric field ・ Instability of klystron operation Prospects of X-band klystron performance by using scaling law

9 Scaling of power capability Break down limit ∝ f 0 ? (Ceramics) P : output power  : pulse duration A. Window electric field strength B. Output cavity electric field strength Break down limit ∝ f 0.3 P : Output power  : pulse duration perv : beam perveance N : number of cavity cells from SLAC (Wang & Loew curve)

10 Results of scaling for output window E3712 E37202 E3768 XL-4

11 Results of scaling for output cavity E3712 E37202 E3768 XL-4

12 Conclusions Scaled output power [MW] from Window performance (A) Scaled output power [MW] from Output cavity performance (B) Remarks 12GHz-1.5μs 1.2μP 12GHz-1.5μs 1.2μP S-band 80MW base 99Normal output cavity Double standard Pill Box Windows C-band 50MW base 1617Multi-cell output cavity Double long Pill Box Windows X-band 50MW 1.5μs base 4546Multi-cell output cavity Double TE01 Windows X-band 50MW 0.5μs base 2226Multi-cell output cavity Double mixed mode Windows

13 Company overview Summary TOSHIBA MEDICAL SYSTEMS CORP. TOSHIBA ELECTRON TUBES & DEVICES CO.,LTD. 1.According to the scaling from E3712 (S band) and E37202 (C band), We are confident that we will provide X-band klystrons with output powers up to 17 MW. 2. Regarding 50-MW and 1.5-  s tube, Even though we know success operation of XL-4, taking account of our experience, we need a couple of years to develop it perfectly.

14 Thank you for your attention