Arreglo EAS-UAP para el Estudio de Rayos Cósmicos alrededor de eV Humberto, Salazar, Oscar Martínez, César Alvarez, L. Villaseñor* + Estudiantes del Grupo de la FCFM-BUAP Facultad de Físico-Matemáticas, Benemérita Universidad Autónoma de Puebla, Apartado Postal 1364, Puebla, Pue., 72000, México *On leave of absence from Institute of Physics and Mathematics, University of Michoacan, Morelia, Mich., 58040, México Coloquio del Grupo de Altas Energías CINVESTAV-IPN D.F. Sept. 20, 2005
At an energy of approximately 3 PeV the spectral index steepens (“knee”). To understand the reason for the knee, one must understand the source, acceleration mechanism, and propagation of cosmic rays. First-order Fermi acceleration has a cutoff energy (protons to eV and Iron to 3 x eV) Observing the mass composition of cosmic rays at the knee therefore provides an important clue to the origin of cosmic rays.
Source Supernova shock-wave Fermi acceleration is correct + Unknown mechanism i.e., rotating compact magnetic objects (neutron stars or black holes) at higher energies = kink due to overlap between the two mechanisms with progressive change in chemical composition as the knee is approached. Propagation Smooth energy distribution up to the highest cosmic-ray energies with unknown loss mechanism beginning at about eV. Measuring the chemical composition of the cosmic rays at eV can test the different explanations.
EAS Array Area: 4000 m^2 10 Liquid Ssintillator Detectors (Bicron BC-517H) 4 Water Cherenkov Detectors PMT Electron tubes 9353 K PMT EMI 9030 A
2200m a.s.l., 800 g/cm2. Located at Campus Universidad Autonoma de Puebla Hybrid: Liquid Scintillator Detectors and water Cherenkov Detectors Energy range 10^14- 10^16 eV
DAQ System Trigger: Coincidence of 3-4 central detectors (40mx40m) NIM y CAMAC. Use digital Osciloscopes as ADCs. Rate: 80 eventos/h
DAQ System Calibration Rate: 250 events/m2/s
Monitoring Use CAMAC scalers to measure rates of single partícles on each detector. Day-night variations <10% /mean around 3%
Calibration
~74 pe
LabView based DAS
MPV of EM peak = 0.12 VEM i.e. around 29 MeV, i.e., dominated By knock-on + decay electrons
Stopping muon at 0.1 VEM Decay electron at 0.17 VEM = 41 MeV Crossing muon at 1 VEM Alarcón M. et al., NIM A 420 [1-2], (1999).
Cherenkov Liquid Scint Muons deposit 240 MeV in 1.20m high water and only 26 MeV in 13 cm high liquid, while electrons deposit all of their energy i.e., around 10 MeV. Therefore for 10 Mev electrons we expect: Mu/EM=24 for Cherenkov Mu/EM=2.6 for Liq. Scint. Muon/EM Separation
Data Analysis Arrival direction sin sin = d/c(t 2 -t 1 )
Angular distribution inferred directly from the relative arrival times of shower front in good agreement with the literature: cos p sen
Data Analysis Lateral Distribution Functions Energy Determination EAS-TOP, Astrop. Phys, 10(1999)1-9 The shower core is located as the center of gravity.
N e, obtained for vertical showers. The fitted curve is I k (N e /N ek ) - , gives =2.44±0.13 which corresponds to a spectral index of the enerfy distributions of =2.6
Cherenkov Liquid Scint Muons deposit 240 MeV in 1.20m high water and only 26 MeV in 13 cm high liquid, while electrons deposit all of their energy i.e., around 10 MeV. Therefore for 10 Mev electrons we expect: Mu/EM=24 for Cherenkov Mu/EM=2.6 for Liq. Scint. Muon/EM Separation
Mass Composition Hybrid Array Solution:
Iterations Start with Ne=82,300 Nmu = E0 = 233 TeV Iterations End with Ne=68000 Nmu = E0 = 196 TeV
Mass Composition Non-Hybrid Array Do a three parameter fit to :
Mass Composition Non-Hybrid but Composite Array Two Identical types of Cherenkov Detectors one filled with 1.20 m of water and the other with 0.60 m, i.e., VEM C’ =0.5VEM C i.e., do independent fits of EM and muon to NKG and Greissen LDF, respectively, where:
Conclusions We have checked the stability and performed the calibration of the detectors. We have measured and analyzed the arrival direction of showers. We determine the energy of the primary by measuring the total number of charged particles obtaining by integration of the fitted LDF. Study of Muon/Electromagnetic ratio is underway: