Tested to BS EN:1366-3 1hr2hr 0 Fire RatingFire Rating You can request from our technical sales office the following information:  Material Safety Data.

Slides:



Advertisements
Similar presentations
DECORATIVE SINGLE COAT PLASTER FOR MARBLE CHIPS CLADDING SYSTEM ( PEBBLEDASH )
Advertisements

Overview Information obtained from FOXDIY.CO.UK J.Byrne 2012.
Application Instructions Bonds to Polyethylene, PVC, Steel, Fiberglass, and Aluminum.
Silglaze N NEUTRAL SILICONE SEALANT SCS2500 SERIES DESCRIPTION
Walls Ron Gatepain constructionsite.
Saving Lives and Property Through Fire and Smoke Containment ©2004 IFC Flexible Fire Resistive Duct Enclosures.
SYNTHETIC RED OXIDE METAL PRIMER It has good anti-corrosive properties. It contains Zinc-chrome. Recommended for agricultural, steel structures & other.
Method to fix wall tiles. Preparation All wall tiles to be immersed in water for 3-4 hours for better results. Some gap in between the rows to allow the.
Building Methods Types of Structure.
Joining, Installing, and Supporting Pipe
Through Penetration Firestops.
After the foundations have been completed the walls are set out and construction commences. wall structures.
Energy Efficient Through-holes Repository: Aho Hanna, Korpi Minna (edit) REALISATION OF AIR PROOF STRUCTURES AND CONNECTIONS IN RESIDENTAL BUILDING Techical.
Topic C1 Superstructures - walls
SELECTION AND INSTALLATION OF BRIDGE EXPANSION JOINTS
Energy Efficient Through-holes The sole responsibility for the content of this publication lies with the authors. It does not necessarily reflect the opinion.
The new technology for watertight construction joints
Products & Accessories Details System Highlights Hands On
SUMMARY FROM ACI 224.1R-93. When anticipating repair of cracks in concrete, it is important to first identify the location and extent of cracking. The.
BondChem TECHNICAL DATA Roll-a-crete ( Three Component Cementitious Waterproof Coating ) Page 1 / 2. DESCRIPTION BondChem’s Roll-a-crete is a three component.
The AFD-01, part of FIRE END range of steel doors, is an economical flush door set, for most internal or external applications in commercial buildings.
Aqua-Mite The one and only true water proofing coating designed for permanent under water usage.
TEAM: FIBREX Waterproofing Coating. Introduction  The ASTM Standard defines it is a treatment of a surface to prevent the passage of water under hydrostatic.
PLASTERBOARDS Plasterboard is a rigid flat sheet material which comprises of a core of gypsum plaster with the surfaces covered by stout paper. This covering.
RENAISSANC E CARPET TILES_.  INTRODUCTION_  BENEFITS_  SUGGESTED SPECIFICATION_  INSTALLATION INSTRUCTIONS_  MAINTENANCE PROCEDURES_  TECHNICAL.
Fire-Resistant Materials & Assemblies Part 2 Chapter 5.
OptiLine Mini-trunking Safe and smoothly shaped – and a joy to work with.
1 RPM/Belgium N.V. - Version MONOPUR GB MONOPUR ® INDUSTRY The heavy duty polyurethane concrete floor system for extreme service conditions.
Quick-Patch Quick-Patch UV Technology The Unique Patch & Repair System.
Redefining the pace and quality of construction ACC Concrete – Value-Added Products & Solutions.
Plumbing Radiant Heating & Cooling Turf Conditioning Permafrost Ice and Snow Melt Ecoflex ® SupportSustainabilityEngineered PolymerCommercial SystemsIntroductions.
Certificate number: FS453/02 Application FS21 Firestop Panel is used to firestop mechanical and electrical services where they pass through fire rated.
COMPACT SHEETING SARLON COMPACT UNI. INTRODUCTION  Compact vinyl flooring contribute to lowering noise disturbance within a building in a number of ways.
Patented Technology – Quality Results Ulti-Pave 3 Pavement Repair Mix 30-Minute Workability 3,000 PSI 3-Hour Set ® “A One Component, Rapid Hardening Cementitious.
COMPACT SHEETING SURESTEP STAR. INTRODUCTION  Surestep is a 2m wide glass fibre-mat reinforced compact antistatic vinyl floor covering, featuring a 0.7mm.
STATIC CONTROL TILES & SHEETING PRIMO SD. INTRODUCTION  Static Dissipative flooring is essential for protecting sensitive equipment from static charge.
2016 SUBSTRATE PREPARATIONS. SUBSTRATE PREPARATION METHODS FOR CONCRETE Very Course Profile Scabbling – Suitable for very aged, weak or contaminated substrates.
Building construction Prepared by : Rall no : : Nayani Paril : Patel Nikunj : Parmar Mihir : Patel Adarsh : Patel Bhavin.
Substrate Identification Floors. Principal Substrates T & G floorboards Flooring grade boards Concrete Screeded concrete Tile Backer Boards Under Floor/Under.
Cavity Wall Construction
Weber Tile Fixing.
THE SCIENCE OF SOLVENT WELDING
SURESTEP ORIGINAL COMPACT SHEETING.
Beyem Fir White Enhanced cement based tile adhesive for interior use
Elastomeric Wall Coating: Garland’s Tuff-Coat™ Systems
SUPERFLEX HOMOGENEOUS VINYL TILES & SHEETING.
High Density Polyethylene (HDPE) Panels or Sheets
Materials Selection and Coatings
METHODS OF CRACK REPAIRS
Flash penetrations through roofs and walls.
INDUSTRIAL FLOOR HOMOGENEOUS VINYL SHEETING.
VINYL TILES & SHEETING_
WALLCLADDING SHEETING_
FLOORWORX SD STATIC CONTROL TILES & SHEETING.
FS24 FIRESTOP COLLAR CONCEALED INTUMESCENT
Building Methods Types of Structure.
Objectives Describe the fasteners, anchors, and adhesives used in construction and explain their uses. f. Identify various types of mechanical anchors.
FLOOR COATINGS TRAINING GUIDE
Pritesh h prajapati Arvind g prajapati Arvind m prajapati Arvind khata.
WATER MAIN REHABILITATION
3M™ Industrial Packaging Tape Guide
Interior Finishes and Detailing
Tapiflex Self-adhesive
REVISION REVISION & EXAM PREPARATION 3 CLADDING 1.
Energy saving for solid walls with Si-Dry
FBE04 BUILDING CONSTRUCTION AND MATERIALS
ELECTRICAL INSTALLATION
Chris Sajbel Pecora Corporation
SCITEQ End closure series
Presentation transcript:

Tested to BS EN: hr2hr 0 Fire RatingFire Rating You can request from our technical sales office the following information:  Material Safety Data Sheets  Installation Instructions Application FS23 HE Intumescent Sealant is recommended for use where a flexible and durable fire resistant seal is required. In the event of fire, the sealant exerts a positive pressure to make a joint, smoke, gas or water tight seal. Tested in accordance with BS EN:1366-3, FS23 HE Firestop Sealant will provide up to 2 hours fire protection. Suitable applications include:  Combustible and non combustible pipes  Cables (single cables or bunches of cables)  Other permanent services  Suitable for masonry/plasterboard walls and concrete floors Fire RatingFire Rating In 2 hour plasterboard wall: In concrete floors: * Mineral wool shutter removed before test In 150mm thick masonry walls: FS23 High Expansion Intumescent Sealant SE A L AN T S Service Penetration Hole Size In Wall Design of Joint Depth of Sealant Fire Integrity 55mm Diameter HDPE/PVC Pipe Up to 100mm x 100mm 25mm annular joint in Pattress fixed coated panel (50mm thick) on both sides of wall 40mm120 mins 110mm Diameter HDPE/PVC Pipe Up to 150mm x 150mm 25mm annular joint in Pattress fixed coated panel (50mm thick) on both sides of wall 40mm120 mins FIRE RATINGS TECHNICAL INFORMATION Service PenetrationHole SizeDesign of Joint Depth of Sealant Fire Integrity 110mm Diameter HDPE / PVC Pipe160mmMineral wool shutter (25mm thick) / sealant*75mm90 mins90 mins Service Penetration Hole Size in Wall Design of Joint Cable Tray (150mm x 25mm)Up to 200mm x 100mm Sealant / Coated Panel / Wool* / Sealant 120 mins Depth of Sealant / Backer Fire Integrity 40 / 50 / 40mm120 mins Fire Insulation Cable Bunch (100mm diameter) Up to 150mm Diameter (25mm annular gap) Sealant / Coated Panel / Wool* / Sealant 60 mins60 mins HDPE / PVC Pipe (110mm) Up to 162mm Diameter (25mm annular gap) Sealant / Coated Panel x 2 40 / 50mm (both sides) 120 mins HDPE / PVC / ABS Pipe (50mm) Up to 150mm Diameter (50mm annular gap) Sealant / Coated Panel x 2 40 / 50mm (both sides) 120 mins * 10mm mineral fibre wool backer

When ordering this product you will need the following information:  Quantity required Please order from our technical sales office. Canada: PO Box 21096, Coquitlam BC V3E 3P9 Canada P: F: Norway: Skibåsen 20b Kristiansand Norway P: F: UAE: PO Box Ajman UAE P: F: Description FS23 HE Intumescent Sealant is an easy to apply water based acrylic emulsion sealant containing graphite which expands at temperatures above 135ºC sealing around various penetrations and services to prevent the passage of smoke and flames. Application Procedure Coverage FS23 HE Intumescent Sealant (310ml cartridge) will yield linear metre per cartridge at 25mm wide and 80mm depth. Approximate coverage rates are shown in the table below. Pipe / Conduit SizeNo of Cartridges 20mm mm mm mm mm mm mm mm mm 2.88 Limitations  The sealant is not intended for application on bituminous substrates or substrates that can exude certain oils and plasticizers or solvents.  The sealant is not recommended for submerged joints or areas exposed to high abrasion.  The sealant is not suitable for food contact or medical applications. Service Temperature Range- 15°C to 70°C All surfaces must be clean and sound, free from dirt, grease and other contamination. W ood, plaster and brick may be damp but not running wet. Use mechanical abrasion to clean porous surfaces before application. For extra performance in movement situations, a primer can be prepared by diluting 1 part sealant with 2 parts of water and mixing thoroughly. The primer should be brush applied and allowed to dry for 2 to 3 hours before applying sealant. Alternatively a standard PVA sealer may be used on the surface. Prepare joint by cleaning and priming if necessary, as previously detailed. Cut nozzle to the desired angle and gun firmly into the joint to give a good solid fill. Strike off the sealant flush with the joint sides within five minutes of application, before surface skinning occurs. A small amount of shrinkage will occur on curing. If a flush finish is required, fill the joint slightly proud of the surface to allow for shrinkage. Application Temperature Range+ 4°C to + 35°C FS23 High Expansion Intumescent Sealant SE A L AN T S ORDERING

Tested to BS 476:Parts 20 & 22:1987 BS EN hr 4hr Fire RatingFire Rating You can request from our technical sales office the following information:  Material Safety Data Sheets  Installation Instructions  Product Certification Certificate number: FS453/05 F30 670A SEALANT FS23A Intumescent Sealant Application FS23A Intumescent Sealant is suitable for sealing joints and service penetrations in fire walls, partitions, fire rated door frames and glazing systems. Tested in accordance with BS 476:Parts 20 & 22:1987 and BS EN , FS23A Intumescent Sealant provides up to 4 hours fire protection in joints of up to 30mm wide. In addition to the fire rating the sealant may be used to seal joints in party walls to provide an acoustic seal. Acoustic FS23A Intumescent Sealant provides a W eighted Sound Reduction Index (Rw) of up to 57dB. Please consult our sales office with details of:  Type of construction  Required acoustic rating  Size of joint Airtight & Smoke Seal FS23A Intumescent Sealant will provide an airtight and cold smoke seal. Fire Rating Description FS23A Intumescent Sealant is a high specification, one part water based acrylic sealant, extruded from a cartridge loaded into a standard sealant gun. The depth of the joint will depend on the gap to be filled and the fire rating required (see fire rating). All surfaces must be thoroughly clean and free of bond breaking contaminants prior to application of the sealant. No priming is required for most construction substrates, however, it is recommended that a small area be tested on substrates. The sealant should not be applied if the ambient temperature is below 5 º C as adhesion will be impaired. The sealant is fast curing approximately 15 minute tack free time. W hen fully cured, the sealant is overpaintable. Under fire conditions the sealant forms a fire resistant ash. SE A L AN T S FIRE RATINGS TECHNICAL INFORMATION Joint SizeDepth of SealantIntegrityInsulationBackingType of Seal 10mm 240 mins30 minsPE FoamSingle 15mm10mm240 mins30 minsPE FoamSingle 20mm15mm240 mins120 minsPE FoamDual 20mm 240 mins60 minsC144 FirestripSingle 30mm15mm240 mins120 minsPE FoamDual 30mm15mm240 mins60 minsC144 FirestripSingle

SE A L AN T S ORDERING When ordering this product you will need the following information:  Size of cartridge  Quantity required Please order from our technical sales office. Canada: PO Box 21096, a Norway: Skibåsen 20b Kristiansand Norway P: F: UAE: PO Box Ajman UAE P: F: Sizes FS23A Intumescent Sealant is available in 310ml cartridges, 600ml foil packs and 900ml jumbo cartridges. Colours The sealant is available in white and grey. coverage rates:coverage rates: Specification Install FS23A Intumescent Sealant to provide up to 4 manufacturer’s instructions. FS23A Intumescent Sealant Joint Size 10mm10mm 20mm20mm Yield per 310ml Depth of Sealant Cartridge 10mm 3.1 metres 15mm 1.03 meters 20mm 0.51 meters 30mm30mm FS23A Intumescent Sealant in blockwork joints. FS23A Intumescent Sealant sealing around service penetrations passing through blockwork wall. FS23A 900ml Jumbo Cartridge FS23A 600ml Foil Pack Coverage hours fire protection in all joints up to 30mm in all Coquitl P: am BC V3E 3P9 Canad One 310mlcartridge will providethefollowingfirewalls. Installation to be fully in accordance with F:

Tested to BS 476:Part 20 & EN hr4hr 0 Fire RatingFire Rating You can request from our technical sales office the following information:  Material Safety Data Sheets  Installation Instructions  Product Certification When ordering this product you will need the following information:  Outside diameter of pipework  Fire rating  Quantity required Please order from our technical sales office. Canada: PO Box 21096, Coquitlam BC V3E 3P9 Canada P: F: Norway: Skibåsen 20b Kristiansand Norway P: F: UAE: PO Box Ajman UAE P: F: Certificate number: FS453/07 General benefits:General benefits:  Simple to install  W ater resistant  Maintenance free  Available to suit pipe sizes ranging from 55mm to 250mm outer diameter  3 rd Party Certificated Fire Rating Suitable for sealing PVC, UPVC, CPVC Polypropylene, HDPE, MDPE, PE plastic pipes. ABS plastic pipes can be sealed up to 55mm. Not suitable for ventilated pipe applications. Please consult our technical sales office for clarification. Specification FS24 Firestop Collars to provide up to 1, 2, 3 or 4 hours fire protection to all plastic pipework. Installation to be fully in accordance with manufacturers instructions. Integral toggles are opened up and the collar is simply fitted around the plastic pipe. The toggles are closed and the collar is pushed flush to the surface of the wall or underside of floor. The collar is then securely fastened to the structure by means of fire resistant fixings threaded through fixing tabs. Annular gaps around the pipe of up to 15mm should be filled with FS21 HE Firestop Sealant. For annular gaps greater than 15mm FS20 Firestop Mortar can be used. Under fire conditions the intumescent material swells filling the void left by the burnt out plastic. 55mm - 250mm2 or 4 Hours FS24 FIRESTOP COLLAR CONCEALED INTUMESCENT FS24 Firestop Collars Application FS24 Firestop Collars provide a simple and effective method of firestopping plastic pipework where it passes through compartment walls and floors. Tested in accordance with BS 476:Part 20 and EN , FS24 Firestop Collars will provide up to 4 hours fire protection. Description FS24 Firestop Collars consist of a powder coated steel sleeve containing a flexible graphite based intumescent liner manufactured to suit the pipework to be firestopped. Outside Diameter of PipeworkFire Rating P I PE W O R K FS24 Firestop Collars fixed to both sides of wall. FIRE RATINGS TECHNICAL INFORMATION ORDERING