Limit State Method Dr S R Satish Kumar, IIT Madras.

Slides:



Advertisements
Similar presentations
Design of Steel and Composite-Structures for Seismic Loading – Safety Requirements, Concepts and Methods – Prof. Dr.-Ing. Ekkehard Fehling, University.
Advertisements

Design of Seismic-Resistant Steel Building Structures
Chapter-2 Parts of Steel Bridge.
Limit States Flexure Shear Deflection Fatigue Supports Elastic Plastic
Design should address: UNDERSTRENGTH OVERLOAD
Loads and Load Paths "Architecture is inhabited sculpture."
Chapter 11 Mechanical Properties of Materials
Imperial College London First-Order Robustness, Higher-Order Mechanics Bassam A. Izzuddin Department of Civil & Environmental Engineering.
Structural Reliability Theory
PLATE GIRDERS Built-up sections with deep thin webs
COMPOSITE BEAMS-II ©Teaching Resource in Design of Steel Structures –
Chapter 5 – Design for Different Types of Loading
Reinforced Concrete Design II
Tripartite Meeting Beijing, 1 November 2005 IMO GBS Classification Society’s View about the Scope, Verification Process and Acceptance Criteria Roberto.
COLUMNS.
1 ENGI 6705: STRUCTURAL ANALYSIS STRUCTURAL ANALYSIS - FUNDAMENTALS.
LRFD-Steel Design 1.
COLUMNS. COLUMNS Introduction According to ACI Code 2.1, a structural element with a ratio of height-to least lateral dimension exceeding three used.
1.
Rehabilitation and maintenance of buildings - 02 Karel Mikeš.
13.4. GENERAL DESIGN CONSIDERATIONS: PRESSURE VESSELS
Preparatory Seminar for STL Examination By Dr. James Lau, BBS JP.
Reliability Analysis Procedures for Infrastructure Facilities Andrzej S. Nowak University of Nebraska - Lincoln Outline  Causes of Uncertainty  Load.
Dr S R Satish Kumar, IIT Madras1 15 Durability and 16 Fire Resistance.
Reinforced Concrete Design
By: Prof Dr. Akhtar Naeem Khan
Lecture 2 - Fundamentals. Lecture Goals Design Process Limit states Design Philosophy Loading.
Chapter 1 بسم الله الرحمن الرحيم Design of Concrete Structure I University of Palestine Instructor: Eng. Mazen Alshorafa.
© Dr S R Satish Kumar, IIT Madras1 SECTION 7 DESIGN OF COMPRESSION MEMBERS.
BEHAVIOUR OF MATERIALS
Structures and Mechanisms Subsystems AERSP 401A. Introduction to Structural Estimation Primary Structure: load-bearing structure of the spacecraft Secondary.
©Teaching Resource in Design of Steel Structures IIT Madras, SERC Madras, Anna Univ., INSDAG 1 COMPOSITE FLOORS - II.
Load Resistance – The Structural Properties of Materials Chapter 4.
ME31B: CHAPTERTHREE INTRODUCTION TO STRUCTURAL DESIGN.
CTC 422 Design of Steel Structures Introduction. Steel as a Building Material Advantages High strength / weight ratio Properties are homogeneous and predictable.
Mechanical Design of Process Equipment FUNDAMENTAL PRINCIPLES AND EQUATIONS Principal stresses Theories of failure
COMPERSION MEMBER.  An initially straight strut or column, compressed by gradually increasing equal  and opposite axial forces at the ends is considered.
Design of Steel Structures Department of Civil Engineering University of Engineering & Technology, Taxila 1.
RELIABILITY IN DESIGN 1 Prof. Dr. Ahmed Farouk Abdul Moneim.
Chapter 6 Design Basis and Safety Criteria National and Euro Codes - Limit State Approach  For structures entailing softening behaviour (cracking of concrete,
1 EUROCODES A tool for building safety and reliability enhancement Workshop on Eurocodes: Training the trainers Moscow - 09 December - 10 December, 2010.
Beam Design Beams are designed to safely support the design loads.
1 Limit State Design Concept. 2 Designer has to ensure the structures, he designs are: Fit for their purpose Safe Economical and durable INTRODUCTION.
Dr S R Satish Kumar, IIT Madras1 IS 800:2007 Section 8 Design of members subjected to bending.
Structural Loads.
DESIGN OF AIRPORT TERMINAL AND CONTROL TOWER
DESIGN AND DETAILING FOR EARTHQUAKE LOADS
IS:800 Section 13 FATIGUE. Introduction Mechanism of Fatigue Fracture Factors Affecting Fatigue Strength Design Strength & Cumulative Fatigue Damage IS:800.
TENSION MEMBERS.
Dr S R Satish Kumar, IIT Madras 1 Section 9 Members subjected to Combined Forces (Beam-Columns)
Limit State Design Concept V.N.Kundlikar
Objectives of Design of Reinforced Concrete Elements
2.1 INTRODUCTION TO ANALYSIS AND DESIGN
DEPARTMENT OF MECHANICAL AND MANUFACTURING ENGINEERING
John Dalsgaard Sørensen Aalborg University, Aalborg, Denmark
Lecture 5 - Flexure June 11, 2003 CVEN 444.
Limit state design (LSD) refers to a design method for RCC Structures
Limit State Design Concept
Structure of a Building
Design of parts for static loading
SECTION 7 DESIGN OF COMPRESSION MEMBERS
PRINCIPLE PROPERTIES OF BUILDING MATERIALS
RELIABILITY IN DESIGN Prof. Dr. Ahmed Farouk Abdul Moneim.
Design of Beams - Limit States
Buckling of Columns A designer should satisfy
CHAPTER 1: INTRODUCTION part B
EAT 415 :ADVANCED STEEL BUILDING DESIGN PLATE GIRDER
An Najah National University Submitted to : Dr.Munther Diab .
Reinforced Concrete Design-3 Flexural Design of Beams
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg.
Presentation transcript:

Limit State Method Dr S R Satish Kumar, IIT Madras

INTRODUCTION Designer has to ensure the structures, he designs are: Fit for their purpose Safe Economical and durable Dr S R Satish Kumar, IIT Madras

Following Uncertainties affect the safety of a structure INTRODUCTION Following Uncertainties affect the safety of a structure about loading about material strength and about structural dimensions about behaviour under load Dr S R Satish Kumar, IIT Madras

LIMIT STATE DESIGN Limit State: State at which one of the conditions pertaining to the structure has reached a limiting value Limit States Limit States of Strength Limit States of Serviceability Strength as governed by material Deflection Buckling strength Vibration Stability against overturning, sway Fatigue cracks (reparable damage) Fatigue Fracture Corrosion Brittle Fracture Fire resistance Dr S R Satish Kumar, IIT Madras

Probability density functions for strength and load effect RANDOM VARIATIONS Resistance, S Load effect, Q f(S) f(Q) Qm Frequency Probability density functions for strength and load effect Sm Dr S R Satish Kumar, IIT Madras

Basis of Limit States Design (R-Q)m f(R-Q)  (R-Q) R-Q R-Q<0 R-Q>0 Fig. 1 Probability distribution of the safety margin R-Q Dr S R Satish Kumar, IIT Madras

PROBABILITY OF FAILURE Dr S R Satish Kumar, IIT Madras

Pf = [- ] SAFETY INDEX  2.32 3.09 3.72 4.27 4.75 5.2 5.61 10-2 10-3 10-4 10-5 10-6 10-7 10-8 Dr S R Satish Kumar, IIT Madras

PARTIAL SAFETY FACTOR Dr S R Satish Kumar, IIT Madras

ALLOWABLE STRESS DESIGN (ASD) Stresses caused by the characteristic loads must be less than an “allowable stress”, which is a fraction of the yield strength Allowable stress may be defined in terms of a “factor of safety" which represents a margin for overload and other unknown factors which could be tolerated by the structure Characteristic Load Effects Characteristic Strength Factor of Safety  Dr S R Satish Kumar, IIT Madras

ALLOWABLE SRESS DESIGN (ASD) Allowable stress = (Yield stress) / (Factor of safety) Limitations Material non-linearity Non-linear behaviour in the postbuckled state and the property of steel to tolerate high stresses by yielding locally and redistributing the loads not accounted for. No allowance for redistribution of loads in statically indeterminate members Dr S R Satish Kumar, IIT Madras

LIMIT STATES DESIGN “Limit States" are various conditions in which a structure would be considered to have failed to fulfil the purpose for which it was built. “Ultimate Limit States” are those catastrophic states,which require a larger reliability in order to reduce the probability of its occurrence to a very low level. “Serviceability Limit State" refers to the limits on acceptable performance of the structure during service. Dr S R Satish Kumar, IIT Madras

General Principles of Limit States Design Structure to be designed for the Limit States at which they would become unfit for their intended purpose by choosing, appropriate partial safety factors, based on probabilistic methods. Two partial safety factors, one applied to loading (f) and another to the material strength (m) shall be employed. Dr S R Satish Kumar, IIT Madras

Deviation of loads from specified values and f allows for; Possible deviation of the actual behaviour of the structure from the analysis model Deviation of loads from specified values and Reduced probability that the various loads acting together will simultaneously reach the characteristic value. Dr S R Satish Kumar, IIT Madras

(Resistance ) (Resistance Factor) LIMIT STATES DESIGN (Load * Load Factor)  (Resistance ) (Resistance Factor) m takes account; Possible deviation of the material in the structure from that assumed in design Possible reduction in the strength of the material from its characteristic value Manufacturing tolerances. Mode of failure (ductile or brittle) Dr S R Satish Kumar, IIT Madras

IS800 SECTION 5 LIMIT STATE DESIGN 5.1 Basis for Design 5.2 Limit State Design 5.3 Actions 5.4 Strength 5.5 Factors Governing the Ultimate Strength 5.5.1 Stability 5.5.2 Fatigue 5.5.3 Plastic Collapse 5.6 Limit State of Serviceability 5.6.1 Deflection 5.6.2 Vibration 5.6.3 Durability 5.6.4 Fire Resistance Dr S R Satish Kumar, IIT Madras

5.1 Basis for Design the structure shall be designed to withstand safely all loads likely to act on it throughout its life. It shall also satisfy the serviceability requirements, such as limitations of deflection and vibration. It shall not suffer total collapse under accidental loads such as from explosions or impact or due to consequences of human error to an extent beyond the local damages. The objective of design is to achieve a structure that will remain fit for use during its life with an acceptable target reliability. Dr S R Satish Kumar, IIT Madras

5.1.3 The potential for catastrophic damage shall be limited or avoided by appropriate choice of one or more of the following: i) avoiding, eliminating or reducing exposure to hazards, which the structure is likely to sustain. ii) choosing structural forms, layouts and details and designing such that the structure has low sensitivity to hazardous conditions. the structure survives with only local damage even after serious damage to any one individual element by the hazard. Dr S R Satish Kumar, IIT Madras

Conditions to be satisfied to avoid a disproportionate collapse building should be effectively tied together at each principal floor level and each column should be effectively held in position by means of continuous ties (beams) nearly orthogonal each storey of the building should be checked to ensure disproportionate collapse would not precipitate by the notional removal, one at a time, of each column. check should be made at each storey by removing one lateral support system at a time to ensure disproportionate collapse would not occur. Dr S R Satish Kumar, IIT Madras

5.3.1 Classification of Actions  by their variation with time as given below: a) Permanent Actions (Qp): Actions due to self-weight of structural and non-structural components, fittings, ancillaries, and fixed equipment etc. b) Variable Actions (Qv): Actions due to construction and service stage loads such as imposed (live) loads (crane loads, snow loads etc.), wind loads, and earthquake loads etc. c) Accidental Actions (Qa): Actions due to explosions, impact of vehicles, and fires etc. Dr S R Satish Kumar, IIT Madras

Partial Safety Factors (Actions) Combina tion Limit State of Strength Limit state of Serviceability DL LL WL/ EL AL WL/EL Lead ing Accompa Nying Leading Accompanying DL+LL+CL 1.5 1.05  1.0 DL+LL+CL+ 1.2 0.53 0.6 0.8 DL+WL/EL 1.5 (0.9)* DL+ER (0.9) DL+LL+AL 0.35 Dr S R Satish Kumar, IIT Madras

PARTIAL SAFETY FACTORS (Strength) Sl. No Definition Partial Safety Factor 1 Resistance, governed by yielding mo 1.1 2 Resistance of member to buckling mo 3 Resistance, governed by ultimate stress m1 1.25 4 Resistance of connection m1 Bolts-Friction Type Bolts-Bearing Type Rivets Welds Shop Fabrications Field Fabrications 1.50 Dr S R Satish Kumar, IIT Madras

5.5 Factors Governing the Ultimate Strength frame stability against overturning and sway Fatigue design shall be as per Section 13 of this code. When designing for fatigue, the load factor for action, f, equal to unity shall be used for the load causing stress fluctuation and stress range. Plastic Collapse  Plastic analysis and design may be used if the requirement specified under the plastic method of analysis (Section 4.5) are satisfied. Dr S R Satish Kumar, IIT Madras

5.6 Limit State of Serviceability Deflections are to be checked for the most adverse but realistic combination of service loads and their arrangement, by elastic analysis, using a load factor of 1.0 Suitable provisions in the design shall be made for the dynamic effects of live loads, impact loads and vibration/fatigue due to machinery operating loads. The durability of steel structures shall be ensured by following recommendations of Section 15. Design provisions to resist fire are briefly discussed in Section 16. Dr S R Satish Kumar, IIT Madras

LIMITING DEFLECTIONS under LL Only Type of building Deflection Design Load Member Supporting Maximum Deflection Indus trial building Vertical Live load/Wind load Purlins and Girts Elastic cladding Brittle cladding Span / 150 Span / 180 Live load Simple span Span / 240 Span / 300 Cantilever span Span / 120 Live load or Wind load Rafter supporting Profiled Metal Sheeting Plastered Sheeting Crane load (Manual operation) Gantry Crane Span / 500 (Electric operation over 50 t) Span / 1000 Dr S R Satish Kumar, IIT Madras

DEFLECTION LIMITS under LL Only Design Load Member Supporting Maximum Deflection Lateral Crane+ wind No cranes Column Elastic cladding Height / 150 Masonry/brittle cladding Height / 240 Crane Gantry (lateral) Span / 400 Vertical Live load Floors & roofs Not susceptible to cracking Span / 300 Floor & Roof Susceptible to cracking Span / 360 Lateral Wind Building --- Height / 500 Inter storey drift Storey height / 300 Dr S R Satish Kumar, IIT Madras

Thank You Dr S R Satish Kumar, IIT Madras