Calibration of a Thermistor Voltage Divider Portland State University Department of Mechanical Engineering ME 121: Engineering Problem Solving.

Slides:



Advertisements
Similar presentations
Determination of the Molecular Weight of Butane
Advertisements

It is very difficult to measure the small change in volume of the mercury. If the mercury had the shape of a sphere, the change in diameter would be very.
Control of Salinity EAS 199B Modifications of ENGR 121 living with the lab.
Control of salinity living with the lab © 2012 David Hall.
Ch15 Thermodynamics Zeroth Law of Thermodynamics
Physics 1809 Minilab 2: Heat and Temperature Physics 1809: The Relationship Between Heat and Temperature Purpose Understand how the total energy in a closed.
Thermo Electric Effects & Temperature Measurement
Temperature Measurement
Lecture 31 Electrical Instrumentation. Lecture 32 Electrical Instrumentation Electrical instrumentation is the process of acquiring data about one or.
Lecture161 Instrumentation Prof. Phillips March 14, 2003.
One Dimensional Steady Heat Conduction problems P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi Simple ideas for complex.
Specific Heat  Introduction—Temperature and Heat  Specific Heat Experiment  Heat Calculation for Water  Calculation of Specific Heat of Sample.
Classification of Instruments :
KY Dept of Education School & Community Nutrition June 2012
Transducers/Sensors: Sample Device Thermistor A thermistor is a temperature-sensing element composed of semiconductor material (typically a mix of metal.
Some Like it Hot and Some Sweat when the Heat is On!!!
Thermistor calibration living with the lab © 2013 David Hall.
Reference Book is. TEMPERATURE AND THE ZEROTH LAW OF THERMODYNAMICS TEMPERATURE AND THE ZEROTH LAW OF THERMODYNAMICS * Two objects are in Thermal contact.
CHAPTER 19: TEMPERATURE 19.1) Temperature and The Zeroth Law of Thermodynamics The concept of temperature – how hot or cold an object feels when is touched.
Thermodynamic Properties of Water PSC 151 Laboratory Activity 7 Thermodynamic Properties of Water Heat of Fusion of Ice.
Melting point determination. Why take melting point? To help identify sample To help identify sample To check purity of sample To check purity of sample.
Thermodynamics Chapter 12.
Chapters Thermodynamics Introduction 1. Equilibrium of mechanical systems: the concept of temperature Three parameters were needed to describe the.
Recrystallization Lab # 2.
Control of salinity living with the lab © 2012 David Hall.
Measuring Heat-Flow Rate Incorporating LabPro™ Interface.
By: Elizabeth Campbell.  Fluorescence is a useful tool for chemists to determine what wavelength of light a compound emits.  A Fluorescence Spectrometer.
Heat and Temperature 9+.
PSC 151 Laboratory Activity 6 Temperature and the Thermometer.
Interpolation.
What is Conduction? Conduction is the transfer of heat energy from one substance to another substance through direct contact.
Ch15 Thermodynamics Zeroth Law of Thermodynamics If two systems are in thermal equilibrium with a third system, then they are in thermal equilibrium with.
Thermodynamics. Temperature What is temperature? Temperature is what we measure with a thermometer. What is a thermometer? A thermometer is any devise.
L. J. MARTINEZ-MIRANDA Dept. of Materials Science and Engineering University of Maryland College Park MD THERMAL CONDUCTIVITY: INTRODUCING THE.
A Watched Cup Never Cools Class Project  When you have a hot cup of coffee, how long does it take until the liquid in the cup reaches room temperature?
Experiment 1. Temperature and Pressure Calibration Temperature measurement tips are illustrated here for one of the setups at Station 4. The reference.
Warm-up 5/8 How much energy is needed to melt exactly 1000 aluminum cans, each with a mass of 14.0 g for recycling. Assume an initial temperature of 26.4.
ELECTRONICS – Input Transducers Engineering Science – National 5.
Lab #8 Heat and Temperature: There is a Difference! Ms. Twardowski – Science Central Middle School 8 Tan.
Curve Fitting the Calibration Data of a Thermistor Voltage Divider Portland State University Department of Mechanical Engineering ME 121: Engineering Problem.
Roberto Silva #65330 February 13,2016 Prof. Eduardo Cabrera.
Temperature Measurement with Thermistors Portland State University Department of Mechanical Engineering ME 121: Engineering Problem Solving.
Fish Tank Project Introduction ME 121Portland State University Mechanical and Materials Engineering.
Applied Science III Mr. Finau. What is Temperature?  Temperature is the measurement of how warm or cold a system is  A system means a particular area.
The (IAT) sensor is mounted in the intake system so the tip will be exposed to the air entering the engine.
Control of salinity living with the lab © 2012 David Hall.
RESISTIVE TEMPERATURE TRANSDUCERS
TEMPERATURE DISTRIBUTION ACROSS THE EXTENDED SURFACE
MECH 373 Instrumentation and Measurements
Measurements & Instrumentation – Module 3
Relate temperature to the kinetic energy of atoms and molecules. Describe the changes in the temperatures of two objects reaching thermal equilibrium.
Data Logging.
Salinity Calibration fit with MATLAB
Specific Heat Capacity Practical
Electronic Components
Differential Op - Amplifier TIM. 1 Introduction 2 Differential Amplifier: 2.1 Input Resistances: 2.2 Differential Gain: 2.3 Common Mode Input: 2.4 Common.
Potential Divider Aims What is a potential divider
Transistor & Voltage Divider
Conductivity Sensor.
The Flow of Food: An Introduction
Heat and Temperature Change
Experiment 6. Freezing Point Depression
Thermal Energy.
ELECTRONIC SYSTEMS Note: There is no compulsory question set on Section 25 of the syllabus. Questions set on topics within Section 25 are always set as.
Input-Output-Process Demo
A Container Challenge This powerpoint is available for teacher use on-line at:
Calibration of Conductivity Sensors
Combustion Reactions.
Jonathan is a newly recruited lab technician at a school laboratory.
Presentation transcript:

Calibration of a Thermistor Voltage Divider Portland State University Department of Mechanical Engineering ME 121: Engineering Problem Solving

A Voltage Divider for Thermistors The thermistor is located in the upper leg of a voltage divider 5V thermistor Analog input 10 kΩ Review: Why use the upper leg and not the lower leg? ME 121: Engineering Problem Solvingpage 1

Calibration Equipment The thermistor and a reference thermometer are placed in an insulated mug that is filled with a range of mixtures of hot and cold water. Thermistor probe Voltage divider for Arduino input Reference Thermometer Note:The fixed resistor in the voltage divider is an integral part of the thermistor calibration. Replacing the fixed resistor with another resistor, even one of the same nominal voltage, will change the calibration. +5V or digital output analog input Insulated Coffee mug ME 121: Engineering Problem Solvingpage 2

Calibration Equipment A digital kitchen thermometer provides the reference standard for calibration of the thermistor probe. ME 121: Engineering Problem Solvingpage 3

Calibration Procedure Once the equipment is assembled and ready to use, perform the following steps to obtain the calibration data. A source of hot water is provided in the laboratory. 1.Fill the coffee mug with water at a desired temperature. Mix hot and cold water as necessary. 2.Insert the reference thermometer and the thermistor probe through the hole in the lid of the mug. 3.Wait for the thermistor probe signal and the reading of the reference temperature to stabilize. 4.Record the temperature and the output of the Arduino analog input reading. Store a large sample of readings so that statistics can be computed. 5.Return to step 1 until you have collected calibration measurements at 8 to 10 temperatures. Ideally you should randomize the order of the temperatures, i.e., you should not take data only in order of increasing or decreasing temperature. ME 121: Engineering Problem Solvingpage 4

Calibration Procedure Use a table to record the nominal measurements along with any qualitative observations ME 121: Engineering Problem Solvingpage 5 T ( ◦ C)V(Volt)Comments

Calibration Procedure Suggestions for improving your results: Let your system come into equilibrium before taking readings.  The thermometer and your thermistor have thermal mass: you need to wait for them to come into thermal equilibrium (i.e., have the same temperature) with the water.  The insulated mug has more thermal mass than the thermometer and the thermistor. It too has to come into equilibrium.  To reduce wait time between measurements, use two thermos mugs. While one mug holds the thermistor, thermometer and the water during the measurements, prep the second mug for calibration at another temperature to give the mug time to equilibrate with the water. When the measurements with the first mug are finished, switch the thermistor and thermometer into the second mug. Use a mug with a lid to reduce heat exchange with the ambient. Randomize the order of temperature measurements ME 121: Engineering Problem Solvingpage 6

Calibration Equation The calibration process suggests a curve fit of the form V = f (T ): many voltage readings for each fixed temperature. We could use a polynomial for V (T ). V = c 1 T n + c 2 T n−1 + · · · + c n-1 T + c n (1) However, to control the temperature of the fish tank, we will need T = f (V ). T = a 1 V n + a 2 V n−1 + · · · + a n-1 V + a n (2) Curve fitting of the calibration data is discussed in another set of slides. ME 121: Engineering Problem Solvingpage 7