CLAS12 Longitudinally Polarized Target R&D Update CLAS Collaboration, October 20, 2015 Chris Keith.

Slides:



Advertisements
Similar presentations
Magnetic Field Finite-Element Calculations for the Upper Cryostat S. Balascuta, R. Alarcon Arizona State University B. Plaster, B. Filippone, R. Schmid.
Advertisements

30 th September 2004 High Power RF Couplers James Rogers High Power RF Couplers ELSRF Daresbury Laboratory.
A polarized solid state target for photon induced double polarization experiments at ELSA H. Dutz TR16 Bommerholz Hartmut Dutz, S. Goertz, A.
Cryostat and Magnet Status Report UIUC EDM Collaboration Meeting LANL June 20, 2005.
Magnet quench during a training run Magnet electrical circuit schematic PROGRESS ON THE MODELING AND MODIFICATION OF THE MICE SUPERCONDUCTING SPECTROMETER.
IR Magnets for SuperKEKB KEK, Norihito Ohuchi 1.IR Magnets (ES, QCS, QC1) 2.Interference between Magnet-Cryostats and Belle 3.Summary SuperB.WS05.Hawaii.
Spectrometer Solenoid Design and Procurement Review Steve Virostek Mike Green Mike Zisman Lawrence Berkeley National Lab MICE Collaboration Meeting October.
23 October 2005MICE Meeting at RAL1 MICE Tracker Magnets, 4 K Coolers, and Magnet Coupling during a Quench Michael A. Green Lawrence Berkeley Laboratory.
1 Update on Focus Coil Design and Configuration M. A. Green, G. Barr, W. Lau, R. S. Senanayake, and S. Q. Yang University of Oxford Department of Physics.
Tracker Solenoid Module Design Update Steve VirostekStephanie Yang Mike GreenWing Lau Lawrence Berkeley National LabOxford Physics MICE Collaboration Meeting.
9 June 2006MICE CM-15 Fermilab1 Progress on the MICE Cooling Channel and Tracker Magnets since CM-14 Michael A. Green Lawrence Berkeley Laboratory.
GlueX Simulations Status Report on CD3 geometry Richard Jones GlueX Collaboration Meeting, Newport News, January 10-12, 2008.
1 Superconducting Magnets for the MICE Channel Michael A. Green Oxford University Physics Department Oxford OX1-3RH, UK.
Spectrometer Solenoid Fabrication & Testing Update Steve Virostek Lawrence Berkeley National Lab MICE CM24 at RAL June 1, 2009.
Managed by UT-Battelle for the Department of Energy Review of NFMCC Studies 1 and 2: Target Support Facilities V.B. Graves Meeting on High Power Targets.
12 March 2006NFMCC Meeting, IIT, Chicago1 Progress on the MICE Cooling Channel and Tracker Magnets Michael A. Green Lawrence Berkeley Laboratory.
Christopher Nantista ML-SCRF Technology Meeting July 28, 2010 REPORT.
Solenoid-Based Focusing Lens for a Superconducting RF Proton Linac Presentation prepared for AEM 11/08/20101I. Terechkine.
Progress on the MuCool and MICE Coupling Coils * L. Wang a, X. K Liu a, F. Y. Xu a, A. B. Chen a, H. Pan a, H. Wu a, X. L. Guo a, S. X Zheng a, D. Summers.
Spectrometer Solenoid Update Steve Virostek Lawrence Berkeley National Lab Roy Preece Rutherford Appleton Lab October 28, 2011 MICE Collaboration Meeting.
16th Crystal Ball Meeting October, 11-13, 2010, Dubrovnik Grigory Gurevich, Yuri Usov Dubna-Mainz Dilution Cryostat of the New Frozen-Spin Target.
Solid Polarized Target Opportunities at JLab Possibilities for Future Experiments.
FAA/NASA Joint University Program for Air Transportation Research Jeff Dickman Chris Bartone June 20, 2003 A New Anechoic Chamber for Nearfield Antenna.
Superconducting Cavities Development at Fermi National Accelerator Laboratory Dmitri Denisov DIET Federation Roundtable, Washington DC, April
DHB, nEDM Collab. Mtg, 15/16 Apr 04 UIUC Test System (Beck, Chandler, Hertzog, Kammel, Newman, Peng, Sharp, Williamson, Yoder; Blackburn, Kenyon, Thorsland)
R&D Status and Plan on The Cryostat N. Ohuchi, K. Tsuchiya, A. Terashima, H. Hisamatsu, M. Masuzawa, T. Okamura, H. Hayano 1.STF-Cryostat Design 2.Construction.
Status of RFCC-Module Development Derun Li Center for Beam Physics Lawrence Berkeley National Laboratory MICE Collaboration Meeting at INFN-LNF, Frascati,
Future activities of the COMPASS polarized target N. Doshita University of Bochum, Germany.
Y. Kisselev PST05 conference Nov 05 1 PST05 Conference Microwave cavity for large COMPASS polarized target By: Y. Kisselev, J. Ball, G. Baum, N.
Hall B Cryogenics CLAS and CLAS12 David Kashy Hall B Lead Engineer May 26, 2010.
1 Preparation for the 3 He Injection Test 11/2007 MIT/BATES D. Dutta*, H. Gao, M. Busch, Q. Ye, X. Qian, W. Zheng, X. Zhu ( Duke University) ASU, BU, Caltech,
HPS Beamline: Background Rates, Sensitivity to Field Uncertainties M. Ungaro1HPS Collaboration Meeting, JLAB, May Concrete Wall thickness Study.
July LEReC Review July 2014 Low Energy RHIC electron Cooling Sergey Belomestnykh SRF and RF systems.
Analysis of the Ammonia Target Polarization Kangkang L. Kovacs, Physics Department, University of Virginia, Charlottesville, VA
Spectrometer Solenoid Fabrication Status and Schedule Steve Virostek Lawrence Berkeley National Lab MICE RAL October 20, 2008.
Magnet vacuum vessel w/radiation shield and cold mass in place Magnet leads (left) and the three cryocoolers on the top of the spectrometer solenoid service.
1.3GHz Input Coupler for ILC
Ding Sun and David Wildman Fermilab Accelerator Advisory Committee
EDMEDM EDM Collaboration Meeting 3-06 Jan Boissevain, P-25 March 2, 2006 NCSU EDM Experiment Design Status.
Test plan for SPL short cryomodule O. Brunner, W. Weingarten WW 1SPL cryo-module meeting 19 October 2010.
COMPASS polarized target for Drell-Yan Michael Pesek Charles University in Prague On behalf of COMPASS PT group PSPT, Charlottesville, Virginia
EDM Engineering Issues General Mechanical Considerations EDM Cryostat Plan D ANSYS EMAG Calculations ANSYS MECH Calculations 3 June ‘03 J. Boissevain.
22 October 2005MICE Meeting at RAL1 Tracker Solenoid Overview Michael A. Green Lawrence Berkeley Laboratory MICE Collaboration Meeting 22 October 2005.
9/17/07IRENG071 Cryogenic System for the ILC IR Magnets QD0 and QF1 K. C. Wu - BNL.
EDMEDM LANL Review of EDM Cost and Schedule Jan Boissevain, P-25 February 11, 2005, Los Alamos National Laboratory EDM Reference Design Tour of the Reference.
ILC IR FINAL FOCUS & EXTRACTION MAGNETS Prepared by Andy Marone ILC Workshop, Sept
Proton Driver – Target Station Interfaces Keith Gollwitzer Fermilab Wednesday May 28, 2014 MAP 2014 Spring Meeting.
17th Crystal Ball Meeting
1 Small Coolers for MICE Michael A. Green University of Oxford Department of Physics Oxford OX1 3RH, UK MICE Collaboration Meeting RAL.
EDMEDM EDM Collaboration Meeting 6-05 Jan Boissevain, P-25 June 20, 2005, Los Alamos National Laboratory EDM Reference Design.
Date 2007/Sept./12-14 EDR kick-off-meeting Global Design Effort 1 Cryomodule Interface definition N. Ohuchi.
8/29/07K. C. Wu - Brookhaven National Lab1 Major Components in ILC IR Hall Interchangeable Detectors.
Ion Accelerator Activities at VECC
The ESS Target Station Eric Pitcher Head of Target Division February 19, 2016.
Status of Polarimeters and Polarized Targets: what are the plans for development of polarized targets to meet the needs of the Day 1 and future experimental.
HTS and LTS Magnet Design and Prototyping for RAON
325 MHz Superconducting Spoke Cavity Coupler status. T. Khabiboulline Power Coupler design for Superconducting Spoke cavities. Originally.
Initial Tests of the JLab Frozen Spin Target Chris Keith Target Group Jefferson Lab September 13, 2007 Brookhaven National Lab.
XFEL beamline loads and HOM coupler for CW
Development of X-band 50MW klystron in BVERI
MICE Meeting at RAL, Oct-23, 2005
AEGIS Magnet System.
by P. Musumeci and F.Tazzioli
BDS Cryogenic System RDR Status and EDR Plans
Polarized Target Activity at the University of Virginia
SPARC RF gun status by P. Musumeci Review committee
HIE-LINAC status report
Pulsed Ion Linac for EIC
3D-Printed mm-Wave Lenses for DNP Target System
Irradiation of Polarized Target Materials
Presentation transcript:

CLAS12 Longitudinally Polarized Target R&D Update CLAS Collaboration, October 20, 2015 Chris Keith

Polarizing Magnet Pumping system Microwaves (140 5T) NMR 1K Refrigerator CLAS12 Solenoid (not to scale) UVA/JLa b ODU CNU ammonia Field PolTar12: components for a dnp target 2 Beam CLAS Collaboration, October 20, 2015

Polarizing Magnet Pumping system Microwaves (140 5T) NMR 1K Refrigerator CLAS12 Solenoid (not to scale) UVA/JLa b ODU CNU ammonia Field PolTar12: components for a dnp target 1.Magnet 2.Microwaves 3.Target Sample 3CLAS Collaboration, October 20, 2015

PolTar12: magnet CLAS12 solenoid design specs 5.0 tesla  B/B ≤ (Ø2.5 x 4 cm central volume)  B/B = Proton reduced ~20% Deuteron reduced ~50%  B/B = negligible effect Polarization v. field dependence for NH 3 and ND 136 GHz M. Seely, Yale 1982 If necessary we can add small shim coils inside the target cryostat to improve the uniformity… 4CLAS Collaboration, October 20, 2015

PolTar12: magnet Sebastian Kuhn: We can also use internal, superconducting coils to adjust the polarizing field for two target samples, and take data on both polarizations simultaneously. Beam Coil 1 & 1A Coil 2 & 2A Target 1 (-80 gauss) Target 2 (+80 gauss) 1K LHe 5 Tesla Carbon Foil Heat shield Vacuum can Question: Can we uniformly irradiate both samples with one microwave source? 5 Pumping tube CLAS Collaboration, October 20, 2015

PolTar12: microwaves And how can we do it if there is no room for a microwave horn? 6CLAS Collaboration, October 20, 2015

PolTar12: microwaves Measure the frequency (137 GHz) Measure the REFLECTED power 2 ft WR-6 rect. waveguide 3 ft oversized circular waveguide Various cavities (copper, aluminum, etc) Liquid crystal film Liquid crystal film changes color according to temperature. Three sensitivities: 25 C 30 C 35 C 7CLAS Collaboration, October 20, 2015

Radiation pattern from a conical horn. Reflected power ~2 mW. Radiation pattern from unterminated waveguide. Reflected power ~2 mW. PolTar12: microwaves 8CLAS Collaboration, October 20, 2015

Attempts to make slotted-style antennae in the circular waveguide were unsuccessful. Very little power transmission, and very large reflected power.  Waveguide “reflectors” worked much better. Radiation pattern from the wedge. Reflected power ~ 2 mW. Wedge-shaped reflector soldered into the circular waveguide. PolTar12: microwaves LC film 9CLAS Collaboration, October 20, 2015

Using a metal cavity makes a tremendous difference. The power is much more uniformly distributed, and reflected power continues to be minimal. Radiation pattern after a 15 s exposure, 25 C film (most sensitive). Note the two “hot spots”. Wedge-shaped reflector inside a copper cavity, OD ~ 4.5 cm LC Film PolTar12: microwaves 10CLAS Collaboration, October 20, 2015

Microwave pattern can be tailored to the desired target geometry. Aluminum cavity w/ hemispherical end cap, diameter ~ 7.5 cm 60 s exposure on 35 C film (least sensitive) Approximate size of two 2.5 x 2.0 cm target cells, w/ 2 cm separation PolTar12: microwaves 11CLAS Collaboration, October 20, 2015

The next step is to make more quantitative measurements Use a grid of 8 thermocouples to map the power distribution inside a 6 cm aluminum cavity Thermocouple junctions are covered by a microwave absorber Assembly is complete Tests are underway PolTar12: microwaves 12CLAS Collaboration, October 20, 2015

PolTar12: target insert Ammonia samples are placed into the target cryostat with a sample insert. It usually contains the microwave and NMR services as well. Senior Staff, October 20, The UVa polarized target

PolTar12: target insert A major obstacle in the design of the CLAS12 polarized target is its overall length, almost 3 meters. This will make installation and replacement of the target sample very unwieldy and more subject to damage and frost. James Brock has introduced a new design that has the potential to alleviate this problem. A proof-of-principle prototype has been constructed and looks very promising. 14CLAS Collaboration, October 20, 2015

PolTar12: target insert In the new design a single, removable insert is replaced by two inserts that remain inside the cryostat. 1. NMR & Microwave insert: a hollow tube with NMR cables & coils, microwave waveguide, and a beam entrance window at the warm end. To pumps 15 Outer vac. can Helium pumping tube 1K refrigerator LHe fill tube NMR coil & cable Waveguide Microwave cavity 4K LHe Helium vapor (gray) Beam window CLAS Collaboration, October 20, 2015

PolTar12: target insert In the new design a single, removable insert is replaced by two inserts that remain inside the cryostat. 2. Sample insert: small container for ammonia sample(s) and liquid helium, with a re-entrant beam window. To pumps 16CLAS Collaboration, October 20, 2015

PolTar12: target insert Preloaded ammonia “cartridges” are placed into the sample insert in the retracted position via a dedicated loading port. To pumps 17 The sample is then moved into the center of the microwave cavity and NMR coil. CLAS Collaboration, October 20, 2015

PolTar12: target insert The sample insert is fill with 1K LHe from the refrigerator and the ammonia is dynamically polarized. To pumps 18 Beam Ready for beam! CLAS Collaboration, October 20, 2015

PolTar12: target insert To pumps 19 The sample is unloaded and replaced by a fresh sample in the same manner. Repeat as necessary… CLAS Collaboration, October 20, 2015

PolTar12: summary Most recent activity on PolTar12 has been on the microwave & target insert subsystems Good progress on the microwaves  results are very promising for the double-cell design New insert design promises to make sample loading and unloading easier  prototype has been constructed & successfully tested Work will now focus on other subsystems  NMR system (remote frequency tuning, optimize coil design)  1 K refrigerator (finalize design & engineering) 20CLAS Collaboration, October 20, 2015

PolTar12: microwaves EIO microwave tube ± 2 GHz (4.87 ±.07 tesla) 34 W max power! No tuning motor Power v. Frequency (CNU measurements) Graph by Sarah Clark 21CLAS Collaboration, October 20, 2015