A.PasseriHigh granularity Pb-SciFi calorimeter1 Construction and tests of a fine granularity lead-scintillating fibers calorimeter P.Branchini, F.Ceradini,

Slides:



Advertisements
Similar presentations
Construction and First Results of a Cosmic Ray Telescope M. P. Belhorn University of Cincinnati 12 June 2008.
Advertisements

The Angra Neutrino Detector Detector, VETO and electronics conceptual design Laudo Barbosa (May 18th, 2006) Centro Brasileiro de Pesquisas Físicas (CBPF)
TileCal Electronics A Status Report J. Pilcher 17-Sept-1998.
Design and First Results of a Cosmic Ray Telescope For Use In Testing a Focusing DIRC M. P. Belhorn University of Cincinnati The BELLE group at the University.
GLAST LAT Project Calibration & Analysis Meeting - August 29, 2005 Benoît Lott Gamma-ray Large Area Space Telescope Response of the GLAST LAT Calorimeter.
Off-axis Simulations Peter Litchfield, Minnesota  What has been simulated?  Will the experiment work?  Can we choose a technology based on simulations?
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
INFN of Genova, Pavia and Roma Flavio Gatti, PSI, February 9 th, Timing Counter status Timing Counter status.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
P. Karchin – PMTs for Scintillator Based Muon Systempage 11/7/2004 January 7, 2004 American Linear Collider Physics Group 2004 Workshop Stanford Linear.
NuMI MINOS The MINOS Far Detector Cosmic Rays and their neutrinos are being collected now. How does this work, and of what use is this data? Alec Habig,
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
1 Alessandra Casale Università degli Studi di Genova INFN Sezione Genova FT-Cal Prototype Simulations.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Feb 10, 2005 S. Kahn -- Pid Detectors in G4MicePage 1 Pid Detector Implementation in G4Mice Steve Kahn Brookhaven National Lab 10 Feb 2005.
VC Feb 2010Slide 1 EMR Construction Status o General Design o Electronics o Cosmics test Jean-Sebastien Graulich, Geneva.
Status of the NO ν A Near Detector Prototype Timothy Kutnink Iowa State University For the NOvA Collaboration.
CALORIMETER system for the CBM detector Ivan Korolko (ITEP Moscow) CBM Collaboration meeting, October 2004.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Status of the Genova activity on a direction-sensitive optical module toward the KM3 detector M.Taiuti WP3 PYLOS 16/4/2007.
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
Fine Pixel CCD for ILC Vertex Detector ‘08 7/31 Y. Takubo (Tohoku U.) for ILC-FPCCD vertex group ILC vertex detector Fine Pixel CCD (FPCCD) Test-sample.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
The Electromagnetic Calorimeter – 2005 Operation J. Sowinski for the Collaboration and the Builders Indiana Univ. Michigan State Univ. ANL MIT BNL Penn.
The 21st International Conference on Ultrarelativistic nucleus-nucleus collisions, March 30 – April 4, Knoxville, TN Results from cosmics and First LHC.
Test beam preliminary results D. Di Filippo, P. Massarotti, T. Spadaro.
DAQ Subsystem Christopher Crawford University of Kentucky Robert Grzywacz University of Tennessee April DoE, Germantown MD.
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
00 Cooler CSB Direct or Extra Photons in d+d  0 Andrew Bacher for the CSB Cooler Collaboration ECT Trento, June 2005.
Proton Test Beam Experimental Program Overall objective: Study response of modified monochrome DC Plasma Display Panels to low energy proton beam. Energy.
Status of the PSD upgrade - Status of the PSD cooling and temperature stabilization system - MAPD gain monitoring system - PSD readout upgrade F.Guber,
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
18 Sep 2008Paul Dauncey 1 DECAL: Motivation Hence, number of charged particles is an intrinsically better measure than the energy deposited Clearest with.
A Brand new neutrino detector 「 SciBar 」 (2) Y. Takubo (Osaka) - Readout Electronics - Introduction Readout electronics Cosmic ray trigger modules Conclusion.
SDHCAL. outline  SDHCAL concept, validation and construction  Test Beam and technological prototype performance  Perspectives and Conclusion  SDHCAL.
The VSiPMT: A new Generation of Photons Detectors G. Barbarino 1,2, F. C. T. Barbato 1,2, R. de Asmundis 2, G. De Rosa 1,2, F. Di Capua 1, P. Migliozzi.
Update on works with SiPMs at Pisa Matteo Morrocchi.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Eli Piasetzky Tel Aviv University Beam Scintillating Fibers PSI, Technical Review, July 2012 Guy Ron Hebrew University Israel.
February 10, 2009, G-APD Workshop, GSI Darmstadt1 APD Laser Test Setup Charles University, Faculty of Mathematics and Physics, Institute of Particle and.
PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND Doug Roberts U of Maryland, College Park.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
Tracker Neutron Detector: INFN plans CLAS12 Central Detector Meeting - Saclay 2-3 December 2009 Patrizia Rossi for the INFN groups: Genova, Laboratori.
K + → p + nn The NA62 liquid krypton electromagnetic calorimeter Level 0 trigger V. Bonaiuto (a), A. Fucci (b), G. Paoluzzi (b), A. Salamon (b), G. Salina.
A possible BGO Setup for the 2008 Beam Test Campaign
Energy and time resolution for a LYSO matrix
The dynamic range extension system for the LHAASO-WCDA experiment
PreShower Characterisations
High Energy Physics experiments.
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Test Beam Request for the Semi-Digital Hadronic Calorimeter
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
Development of a Compton Camera for online range monitoring
BTF microbunching structure with Micro-Channel Plate PMT
PSD Front-End-Electronics A.Ivashkin, V.Marin (INR, Moscow)
Diagnostics of FRIBs beam transport line
Semi-Digital Hadronic CALorimeter
A First Look J. Pilcher 12-Mar-2004
FPGA-based Time to Digital Converter and Data Acquisition system for High Energy Tagger of KLOE-2 experiment L. Iafolla1,4, A. Balla1, M. Beretta1, P.
The Pixel Hybrid Photon Detectors of the LHCb RICH
Directional Optical Module Integration
Multianode Photo Multipliers for Ring Imaging Cherenkov Detectors
Department of Physics and Astronomy,
PID electronics for FDIRC (Focusing Detector of Internally Reflected Cherenkov light) and FTOF (Forward Time of Flight) Christophe Beigbeder and Dominique.
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

A.PasseriHigh granularity Pb-SciFi calorimeter1 Construction and tests of a fine granularity lead-scintillating fibers calorimeter P.Branchini, F.Ceradini, B.Di Micco, A.Passeri INFN Roma Tre and Dipartimento di Fisica Università Roma Tre and G.Corradi INFN, Laboratori Nazionali di Frascati International Conference on Calorimetry in High Energy Physics Pavia, may 27 th 2008

A.PasseriHigh granularity Pb-SciFi calorimeter2 Sampling fraction 12 % The starting point: the KLOE Calorimeter  E /E  5.7% /  E(GeV)  T  54 ps /  E(GeV)  50 ps PID mostly from TOF Light readout in 4.4x4.4 cm 2 cells on both sides via light-guides + fine mesh PMs Excellent performances :

A.PasseriHigh granularity Pb-SciFi calorimeter3 Motivation Exploit the KLOE calorimeter homogeneity to build a dense imaging device. Accurate cluster shape reconstruction would allow: efficient PID near energy depositions separation study details of the energy release process for different particles types and tune clustering algorithms accordingly. Note: this idea has started in the KLOE-2 project, but its implementation into an upgrade of the KLOE calorimeter turned ou to be very difficult. Then it has to be considered an independent development. two electrons 200 MeV spaced by 4.4 cm two muons 200 MeV spaced by 4.4 cm Example from detailed FLUKA simulation:

The concept : thin light guides + multi-anode PMs 3 x 5 4.2x4.2 cm 2 cells → 240 small cells 1.05x1.05 cm 2 A KLOE calorimeter prototype was available Standard light readout already present on one side: 15 cells 4.2 x 4.2 cm 2 over 5 planes, each instrumented with a standard 1” PM. 23 cm 13 cm 52 cm Standard readout side Our project: Collect the light with segmented guides Detect the light with multianode PMs 1 KLOE cell → 16 pixels

A.PasseriHigh granularity Pb-SciFi calorimeter5 Hamamatsu R8900-M16 Window material: Borosilicate glass Arrangement and Type : 4 x 4 grid Number of channels : 1 6 (each 5.7x5.7mm 2 ) Effective Window Area: 23.5x23.5mm 2 Photocathode material: Bialkali Spectral response range: 300 to 650 nm The multi-anode PM Compact design Operation HV: V A signal with sum of all the 16 last dynodes is also provided Up to 30% gain variation between the 16 pixels We purchased 12 standard R with higher quantum efficiency

A.PasseriHigh granularity Pb-SciFi calorimeter6 Multi anode signal pre-amplification stage A dedicated 16+1 channel pre-amplification stage has been developed using simple inverting x10 amplifiers. Positive signals are needed to be able to use the KLOE electronic chain. 16 ch HV distribution board also produced PM socket Preamp stage Test version

A.PasseriHigh granularity Pb-SciFi calorimeter7 A ps laser pulse used to illuminate single pixels and study the multi-anode response. Single channel Multi anode characterization Laser pulse Linearity collected charge (pC) Laser power (a.u.)

A.PasseriHigh granularity Pb-SciFi calorimeter8 Gain (non) uniformity For each channel the response has been measured relatively to the 500 V Slopes with HV are essentially the same Offset is quite different from channel to channel

A.PasseriHigh granularity Pb-SciFi calorimeter9 Gain 800 V Gain non-uniformity measured for all our multianodes. Similar behaviour always found Two sample cases :

A.PasseriHigh granularity Pb-SciFi calorimeter10 Cross talk Laser pulse injected in individual pixels, Charge response measured in all the others For each PM we obtain a 16x16 cross talk matrix: Electronic cross talk between nearby channels can be as much as few % Non adjacent channels have almost negligible cross talk

A.PasseriHigh granularity Pb-SciFi calorimeter11 Want to map 16 contiguous cells 1.05x1.05 cm 2 into 16 cells 0.53x0.53 cm 2 each separated by a 0.11 cm dead zone (multinode cell area is indeed 0.57x0.57 cm2). UV transparent plexiglass BC800 has been used, to fully match the R8900 spectral response Not trivial mechanics: all surfaces at different angles guides are 6 cm long and touch each other only on the calorimeter surface. a small aluminum grid keeps the 16 guides in place at the PM side Light guides

A.PasseriHigh granularity Pb-SciFi calorimeter12 Light guides: final product No black painting or envelopes on individual guides. Air/plexiglass surface considered the best compromise. Optical cross talk will have to be checked out.

A.PasseriHigh granularity Pb-SciFi calorimeter13 Final assembly in a 3 x 5 matrix Ready to be glued on the calorimeter surface

A.PasseriHigh granularity Pb-SciFi calorimeter14 calorimeter Segmented light guides PM case Multianode socket electronics Full mechanical design

A.PasseriHigh granularity Pb-SciFi calorimeter15 PM case holds also HV distribution and preamp board The full case is light tight

A.PasseriHigh granularity Pb-SciFi calorimeter16 Prototype mounted on a support that allows rotation

A.PasseriHigh granularity Pb-SciFi calorimeter17 Finally the optical contact !

A.PasseriHigh granularity Pb-SciFi calorimeter18 Cross talk : electronic vs optical We dismantled the opposite side light readout system (we will re-install it later). We injected the ligh pulse on individual fibers on this now free calo side and study the response of the pixels on the other side: Single multi anode cross talk confirms what previously observed: few % on nearby channels. The response of the two nearest row of the adjacent PM show really Negligible optical cross talk !!!

A.PasseriHigh granularity Pb-SciFi calorimeter19 Readout and Data acquisition It is fully made with KLOE electronics: signals are first splitted, discriminated and summed (SDS boards) KLOE ADCs and TDCs are then used to digitize them DAQ goes via asyncronous readout Using 2 custom buses and a chain of ROCKs (read out controller for KLOE) online CPU is the only new element: a Motorola MVME6100 Trigger exploits the signal sums provided By SDS, but it is simply done by NIM

A.PasseriHigh granularity Pb-SciFi calorimeter20 First cosmic rays ! Calorimeter in auto-trigger on the coincidence of first and last plane of m-anodes: Simple event display shows the imagin power of the detector Interesting topology can be searched for (muon range, muon decay, protons…)

A.PasseriHigh granularity Pb-SciFi calorimeter21 Equalization : Due to gain non-uniformity HV can be used only to equalize the full multianode response. We used the summ of all pixels in same PM, and fixed it around 3000 counts.

A.PasseriHigh granularity Pb-SciFi calorimeter22 Looking for MIPs … Total energy Number of channels above threshold Total energy has nice Landau shape as also the number of channels… Pixel counting at this level is a good energy esimate ! light Mip peak However individual channels have still a bit of light contamination. Better cell selection needed to have Clean mips. Shielding must be improved

A.PasseriHigh granularity Pb-SciFi calorimeter23 Conclusions A fine granularity calorimeter prototype has been realized using a KLOE calorimeter piece with segmented light guides and Hamamatsu multianode PMs. The response of individual channels has been studied with a laser pulse and the cross talk measured. Optical cross talk is negligible. A full system is now operating. Many cosmics rays have been acquired and are being analyzed. A test beam with electron at BTF in Frascati has also just finished…

A.PasseriHigh granularity Pb-SciFi calorimeter MeV electron 100 MeV electron A couple of displays from BTF…