Fondazione Bruno Kessler Centre for Materials and Microsystems.

Slides:



Advertisements
Similar presentations
New developments of Silicon Photomultipliers (for PET systems)
Advertisements

Liverpool Group presentation 22/07/2009
Scintillator Tile Hadronic Calorimeter Prototype (analog or semidigital) M.Danilov ITEP(Moscow) CALICE Collaboration LCWS04, Paris.
A. Gola, A. Ferri, C. Piemonte, A. Picciotto, T. Pro, N. Serra, A
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
CHARGE COUPLING TRUE CDS PIXEL PROCESSING True CDS CMOS pixel noise data 2.8 e- CMOS photon transfer.
Novel approach for calibration breakdown voltage of large area SiPM
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
H.-G. Moser Max-Planck-Institut for Physics, Munich CALOR 06 Chicago June 5-9, 2006 Silicon Photomultiplier, a new device for low light level photon detection.
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
C. Piemonte 1 Development of SiPMs a FBK-irst C.Piemonte FBK – Fondazione Bruno Kessler, Trento, Italy
Salvatore Tudisco The new generation of SPAD Single Photon Avalanche Diodes arrays I Workshop on Photon Detection - Perugia 2007 LNS LNS.
SiPM: Development and Applications
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Silicon Photomultipliers
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)
Study of the MPPC for the GLD Calorimeter readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group May 29 – Jun 4 DESY Introduction.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
SiPM technology at FBK C. Piemonte
Optimization of Detectors for Time of Flight PET Marek Moszyński, Tomasz Szczęśniak, Soltan Institute for Nuclear Studies, Otwock-Świerk, Poland.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
10 th Pisa Meeting on Advanced Detectors, Isola d’Elba, May 2006 Development of the first prototypes of Silicon Photomultiplier at ITC-irst N. Dinu, R.
28 June 2007G. Pauletta: ALCPG Tests of IRST SiPMs G. Pauletta Univ. & I.N.F.N. Udine Outline 1.IRST SiPMs : baseline characteristics 2.first application.
9 th “Trento” Workshop on Advanced Silicon Radiation Detectors Genova, February 26-28, 2014 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica.
Silicon Photo Multipliers as readout for the NA62 CEDAR Detector Silicon Photo Multipliers as readout for the NA62 CEDAR Detector The NA62 Collaboration.
1 CPTA Center for Prospective Technologies & Aparatus ©2009 – Photonique SA (DMC) APD-Pixel Photo-Diodes for Frontier Detector Systems - GSI Darmstadt.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
1 RGB_HD SiPM Red-Green-Blue High Density SiPM SiPM: size: 4x4mm 2 cell size: 30x30um 2 # cells: ~17000 SiPM: size: 2.2x2.2mm 2 cell size: 15x15um 2 #
Performance of new MPPC Nov. 21 Korea-Japan joint meeting Takashi Maeda Hideki Yamazaki Yuji Sudo (University of Tsukuba) --- Contents ---
SiPM from ST-Microelectronics Nepomuk Otte & Hector Romo Santa Cruz Institute for Particle Physics University of California, Santa Cruz
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
G. Zappala’ – Vienna Conference on Instrumentation 2016
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
CERN PH MIC group P. Jarron 07 November 06 GIGATRACKER Meeting Gigatracker Front end based on ultra fast NINO circuit P. Jarron, G. Anelli, F. Anghinolfi,
Update on works with SiPMs at Pisa Matteo Morrocchi.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Development of UV-sensitive MPPC for upgrade of liquid xenon detector in MEG experiment Daisuke Kaneko, on behalf of the MEG Collaboration µ γ Liquid xenon.
Development of characterization facilities and front-end electronics for SiPM R. A. Shukla, For SiPM Development Group.
Silicon Photomultiplier Development at GRAPES-3 K.C.Ravindran T.I.F.R, OOTY WAPP 2010 Worshop On behalf of GRAPES-3 Collaboration.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
D. Renker, PSI G-APD Workshop GSI, PAUL SCHERRER INSTITUT Problems in the Development of Geiger- mode Avalanche Photodiodes Dieter Renker Paul Scherrer.
A Compact, High Density Gamma-Detection Module for Time-of-Flight Measurements in PET Applications I. Sacco, P. Fischer, M. Ritzert Institute for Computer.
P. Lecoq CERN2 February ENVISION WP2 Meeting CERN Group contribution to ENVISION WP2 Paul Lecoq CERN, Geneva.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
Development of Multi-Pixel Photon Counters (1)
IFR Detector R&D status
Introduction to the physics of the SiPM
Performance of scintillation pixel detectors with MPPC read-out and digital signal processing Mihael Makek with D. Bosnar, V. Gačić, L. Pavelić, P. Šenjug.
CEPC ScECAL Optimization for the 3th CEPC Physics Software Meeting
Performance of LYSO and CeBr3 crystals readout by SiPM
Progress report on SiPM development and its applications
Laser and alpha particle characterization of floating-base BJT detector. Vladyslav Tyzhnevyia, Giovanni Batignanib, Luciano Bosisioc,Gian-Franco Dalla.
Characterization and modelling of signal dynamics in 3D-DDTC detectors
NUV-SiPM short technology description
First production of Ultra-Fast Silicon Detectors at FBK
SiPM+NINO as a detection system for CEDAR
New Study for SiPMs Performance in High Electric Field Environment
On behalf of the GECAM group
HCAL – SiPM upgrade requirements
Comparison of CPTA and Hamamatsu SiPMs
md-NUV PET project meeting
UCM-ELEC group Members involved in the work described here
T2Kロシアグループに向けたMPPC(SiPM)の性能評価
The MPPC Study for the GLD Calorimeter Readout
Latest Developments on SiPM for CTA
Presentation transcript:

Fondazione Bruno Kessler Centre for Materials and Microsystems

SiPM Technology at FBK 2 A. Gola, F. Acerbi, A. Ferri, A. Picciotto, C. Piemonte, G. Paternoster, G. Zappalà, N. Zorzi IFD 2014 – Trento – March 11-13, 2014

Original technology FBK technology evolution 2006 RGB-SiPM (Red-Green-Blue SiPM)  excellent breakdown voltage uniformity  low breakdown voltage temperature dependence  higher efficiency  very low dark noise NUV-SiPM (Near-UV SiPM)  excellent breakdown voltage uniformity  low breakdown voltage temperature dependence  high efficiency in the near-ultraviolet  very low dark noise 2012 RGB-SiPM HD (Red-Green-Blue SiPM – high density) small cell size with high fill factor electric field engineering new cell border new junction 3 IFD 2014 – Trento – March 11-13, 2014

RGB-HD high density 4 IFD 2014 – Trento – March 11-13, 2014

Why small cells? 1. Lower correlated noise, because of lower gain (lower C d ): - lower afterpulsing - possibly lower direct and delayed Optical CT - lower external Optical CT (with scintillator) Larger linear dynamic range. 3. Faster recharge time. - reduced pile-up - useful with «slow» scintillators (CsI) for further extended dynamic range All are important to optimize spectroscopic and timing performance. IFD 2014 – Trento – March 11-13, 2014

We completely re-designed the cell border structure of the RGB technology to have small cells with high fill factor using trenches. RGB-HD structure: L < 2 um (originally it was 7 um). L is the dead border region around a cell 6 Difficult? Yes. The Fill Factor (FF), also called geometrical efficiency, is the ratio: New TechnologyOld Technology IFD 2014 – Trento – March 11-13, 2014

7 RGB-HD optimal cell size For a given border dead space, the choice of the optimal cell size is not obvious: Larger cells provide higher Fill Factor (FF) and thus higher PDE. Smaller cells reduce the correlated noise, which ultimately limits the over-voltage and thus the PDE. We produced many cell sizes and characterized their performance experimentally. (measurements are ongoing) IFD 2014 – Trento – March 11-13, 2014

8 RGB-HD Layouts All are much smaller than the traditional 50 um (67 um) cells! Very good linearity! High Fill Factor IFD 2014 – Trento – March 11-13, 2014

9 Photo Detection Efficiency (PDE) 30 um cell Without correlated noise! RGB SiPM technology: Peak PDE in the blue/green IFD 2014 – Trento – March 11-13, 2014

10 Photo Detection Efficiency 591 nm (without correlated noise) Larger cells and FF, same technology IFD 2014 – Trento – March 11-13, 2014

11 Gain Smaller cells Old Technology IFD 2014 – Trento – March 11-13, 2014

12 Excess Charge Factor (ECF) The ECF can be considered an upper bound for the Excess Noise Factor. Smaller cells IFD 2014 – Trento – March 11-13, 2014

13 PDE/ECF Quantifies the worsening of the Poisson statistics due to the photo- detector  “effective” PDE 591 nm At high V OV, smaller cells are more efficient than larger ones due to ENF IFD 2014 – Trento – March 11-13, 2014

14 V BD Uniformity and Temp. Stability Breakdown voltage (V BD ) uniformity Breakdown voltage variations with T ΔG/G < 1%/°C is possible! Gain temperature stability V BD variations <  150 mV inside the wafer and between wafers. Important at the system-level IFD 2014 – Trento – March 11-13, 2014

15 Temperature dependence of DCR Arrhenius plot of SiPM reverse current 20 um cell 4 V OV Fast DCR reduction with T ≈ E g /2 Electric Field Engineering for low band-to-band tunneling IFD 2014 – Trento – March 11-13, 2014

Signal Shape Very fast single cell response (SCR) 16 Response to fast light pulse from LED  = 9ns 15 um cell Response to LYSO (511keV)  = 43ns Thanks to the fast SCR, the LYSO decay time constant is preserved. IFD 2014 – Trento – March 11-13, 2014

IFD 2014 – Trento – March Radiation Damage in SiPMs The main effects of radiation damage, in SiPMs, are: Increase in the primary noise (DCR). Increased afterpulsing (increased number of traps). PDE loss due to cells busy with dark counts. Increased power consumption due to higher DCR. Mitigation of the effects of rad. damage with RGB-HD: E field engineering allows a steeper reduction of DCR with cooling. Low gain reduces afterpulsing (for a given number of traps). Many, smaller cells with faster recharge are less sensitive to the phenomenon. Lower gain means less current (for a given DCR).

18 Measurements after Irradiation Measurements carried out by Y. Musienko and A. with a dose of n/cm 2. After irradiation: Dark current increased up to 450 μA Gain*PDE change is < 10% PDE change is < 10% ENC(50ns gate) ~ 20 p.e. RMS Noise increase PDE loss Parameters measured at V OV =2.7 V (PDE(515 nm)=15%) IFD 2014 – Trento – March 11-13, 2014

Thank you! 19

IFD 2014 – Trento – March Timing Resolution (hints) FWHM ≈ 20 ps! Single photon time resolution 10 um SPAD Time resolution vs. number of photons 1x1 mm 2 SiPM – 50 um cell 30 ps FWHM ~1/sqrt(N) Measurements on older RGB-SiPM technology at 23 °C.