Vertical Pump Motor Manifold Upgrade. VPMM Replaces Existing Pumps, Motors, Relief Valves, Check Valves, Discharge Filters, Pump Running Pressure Gauges,

Slides:



Advertisements
Similar presentations
Coach Air Conditioning
Advertisements

The idea evolved from two different contractor customers who shared with us a better way to perform hydrostatic testing of DWV piping system. Two different,
Charging. Charging Step 1 Should the lineset length of an installation exceed the charge supplied with the outdoor unit, additional charge will be required.
Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank.
Operating Nitrox Systems 11 Presented by Nuvair. Operating Nitrox Systems2 Membrane systems produce nitrox efficiently Compressed air flows through the.
3.4.5 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Pumps, Strainers and Bypass Systems Knowing how to maintain.
1 FUEL SYSTEM SERVICE ENGINE CLEAN FUEL TOOL MODEL RX 777.
Left Side Discharge Pressure Regulator
Stanley HP-1 Compact Power Unit.
Hydraulic fluid flow through an HWH dual cylinder (Synchronized) room extension.
Oxyacetylene Torches.
Morgan City Rentals Diesel Jet Pump 6 x 6 Peerless Safe Operating Practices and Procedures.
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
1 DIESEL FUEL TOOL ON VEHICLE DIESEL FUEL SYSTEM SERVICE MODEL Rx HD 888 INSIDE FILTER.
CAFS On-Line Orientation
GNI0003H PP1 Loop Trainer. GNI0003H PP2 Reason for Study Because the Loop Trainer gives instructors the capability to control water flow, pressure and.
Presents Installation Instructions. Pre-Installation Cold-Plus® installation requires a qualified refrigeration technician –Before installation perform.
Reservoirs Covered in Ch. 5 of Vickers Text
1B-1 Fire Engine Maintenance Unit 1B – Pump Inspections and Maintenance.
Boiler Mountings.
Suction Pumps.
Proper Pump Installation Practices
Dennis Sabre Fire Appliances
PEUGEOT 206 INSTALLATION 99’— 05’ TU5JP4
THE INTERNATIONAL SOCIETY OF FIRE SERVICE INSTRUCTORS Electronic INSTRUCT-O-GRAM Program Lockout / Tagout Policy.
Pump Installation Vigyan Ashram, Pabal.
AccuMax Multi-Point Injection Mechanics
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Hydronic Mechanical Controls
Hydraulics For The Long Term
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
1 Fuel Pumps. 2 Pumps 1.All oil burners for residential heating have pumps A. They are connected to a motor through a coupling 2.Description A. An oil.
Water Handling Operations
Left side compressor behind Left control box Right side compressor behind Right control box.
Water Supply Skill Drills.
“Fix Tube Sheet” Heat Exchanger
Hydraulic Symbols. Piping and Tubing Symbols Normal working line Flexible working line Pilot line Drain line Enclosure outline Direction of flow.
TRENTON Casing Filler Presentation
1 HVAC122 - Gas Gas Valves. 2 Solenoid Gas Valves The solenoid gas valve is the simplest of all valves. This valve has an electrical magnetic coil which.
Lockout/Tagout.
Weekly Checks Monday – VSP Room Tuesday – Pilothouse System Controls Wednesday – Starboard / Engine Room Thursday – Foam Room Friday – Port / Engine Room.
Monday – VSP Room weekly checks Visually Check: Hvac system for leaks & valve settings Fresh water system for leaks & valve settings VSP linkage Autopilot.
HPU FILTERS LOW PRESSURE FILTER FROM APU UNIT. CLOSE APU HYDRAULIC FLUID VALVE. FILL FILTER WITH HYDRAULIC FLUID PRIO TO INSTALLATION. LUBRICATE GASKET.
Machinery Cooling Water System Locations and Operations.
Ships Service Air System
Automotive Heating and Air Conditioning, Fifth Edition By Tom Birch © 2010 Pearson Higher Education, Inc. Pearson Prentice Hall - Upper Saddle River, NJ.
OILGEAR PVV PUMPS PVV 200 Performance Curves.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
6/9/2016 Quick Reference Parts Guide Introduction This Quick Reference Parts Guide is an easy way to locate part numbers to common replacement parts. It.
STEP 1 Locate the transmission cooler line connection on the vehicle. Identify the correct adapters to be used by referring to the vehicle application.
Procedures.
MAINTENANCE INTERVAL SCHEDULE D6R TRACK TYPE TRACTOR 7AR EVERY 10 SERVICE HOURS OR DAILY.
EBS-1 # COOLANT FLUID EXCHANGE QUICK REFERENCE ATTENTION: Using the Coolant Fluid Exchange requires the FILL and VAC Valves on the SERVICE.
Tractor Safety, Operation, and Maintenance
Gauge Installation and Removal Procedures By: Inmer Amaya.
For system diagrams and component identification
HYDRAULIC & PNEUMATIC CIRCUITS
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
14 Refrigerant Recovery, Recycling, and Recharging.
R1 Fundamentals of Refrigeration
OBJECTIVES Discuss the various methods of loosening the brake bleeder valve. Discuss the need for brake bleeding. Describe the manual bleeding procedure.
Vertical Pump Motor Manifold –D Operations and Maintenance
KFA45 Hydraulic System Overview
SB Packing Automatic Downpuller Power Unit
Troubleshooting 11/14/2018 Water King Service Seminar.
Forrest Keller & David Fortney
R1 Fundamentals of Refrigeration
FUEL DELIVERY SYSTEM Copyright © MILE 2011 MILE / XUV500 / IC / VER 01 / JUL 2011.
Presentation transcript:

Vertical Pump Motor Manifold Upgrade

VPMM Replaces Existing Pumps, Motors, Relief Valves, Check Valves, Discharge Filters, Pump Running Pressure Gauges, Pressure Switches and Reservoir Heaters Replaces Existing Pumps, Motors, Relief Valves, Check Valves, Discharge Filters, Pump Running Pressure Gauges, Pressure Switches and Reservoir Heaters

VPMM Components Motor Pump VPMM Manifold Reservoir Pad Heater

VPMM Manifold Components Pump Discharge Flow Gauge Pump Running Pressure Gauge Pressure Switch Isolation Valve Pump Discharge Filter Cap Pump Pressure Switch Pressure Gauge Isolation Valve Pump Discharge Differential Pressure Indicator

VPMM Manifold Components continued Filter Drain Port Discharge Filter Cap Safety Relief Valve Filter Cap Test Point Pump Casing Fill Port

VPMM Components continued Pump Suction (Inlet) Isolation Valve

VPMM Startup and Operation

VPMM-Startup and Operation Verify that pump casing is full of fluid –Only required on initial startup of pump, after performing maintenance on the pump or if the reservoir is drained –Fill thru Pump Casing Fill Connection on VPMM manifold

VPMM-Startup and Operation Verify that Pump Suction (Inlet) Isolation Valve is opened Pump Suction (Inlet) Isolation Valve

VPMM-Startup and Operation continued FV-1 Valve Pump Discharge Isolation Valve Open Pump Discharge Isolation Valve Open system Bypass Valve FV-1

VPMM-Startup and Operation Open Pump Running Pressure Gauge and Pressure Switch Isolation Valves Start the Pump Slowly close FV-1 Valve Pump Running Pressure Gauge Pressure Switch Isolation Valve Pump Pressure Switch Pressure Gauge Isolation Valve

VPMM Changing Discharge Filter

Change filter element –Whenever high differential pressure is indicated Fluid must be above 85 o F for reliable alarm Differential Pressure Indicator

VPMM Changing Discharge Filter continued Start standby pump and verify it is running properly Shut down the pump where filter will be changed and tag out motor Close associated pump discharge line isolation valve

VPMM Changing Discharge Filter Filter Cap Test Point Schroeder Microflex hose Attach one end of the Schroeder Microflex hose (provided with VPMM) to the test point on the filter cap in order to bleed off any residual hydraulic pressure and lace a container that will hold approximately one quart of EHC fluid under this port.

VPMM Changing Discharge Filter continued Remove the cover on the fitting on the port labeled, “FILTER DRAIN PORT”. Filter Drain Port

VPMM Changing Discharge Filter continued Clean off the top of the pump control manifold using a clean lint free cloth Loosen the four bolts holding the filter cap to the pump control manifold. Fluid should start to drain out of the “FILTER DRAIN PORT Filter Cap

VPMM Changing Discharge Filter continued Filter Cap Filter Element Remove the filter cap

VPMM Changing Discharge Filter continued Remove the high pressure filter element and replace it with the new one.

VPMM Changing Discharge Filter continued Prior to replacing the filter cap check the o-ring and replace as needed Filter Cap O-Ring

VPMM Changing Discharge Filter continued Replace the filter cap. Replace the cover in the port labeled, “FILTER DRAIN PORT”.

VPMM Changing Discharge Filter continued Schroeder Microflex hose Filter Cap Test Point Pump Control Manifold Test Point Verify that one end of the Microflex test hose is still connected to the test point on the filter cap and connect the other end to the test point on the pump control manifold

VPMM Changing Discharge Filter continued With the pump discharge isolation valve closed, start the hydraulic pump and allow the pump to run for at least one (1) minute. Shut the pump down Remove the Microflex test hose from both test points Open the pump discharge isolation valve. Return the pump to “Normal” or “Standby Mode”

VPMM Heaters and Control Cabinet

Reservoir Heater x 6Heater Control Cabinet

VPMM Heater Control Cabinet Power On Light Heater Controller Electrical Disconnect Switch Heater On Light

VPMM Heater Control Cabinet continued Heater Control is pre-programmed and ready to operate –Close Electrical Disconnect Switch Adjustable set point set at 85 o F –The Side Stream Filtering System should be in service when the main pumps are shut down for efficient heating of the fluid

Thank You Barry Sibul & Company 1400 S. Ocean Blvd. Suite N-902 Boca Raton, FL Phone Fax Web site -