1 Evaluation of two volumetric flow cytometers for the quantitation of CD4+ T-cells in Thai HIV-1 infected patients Yuwadee Phuang-ngern, Vallerut Pobkeeree,

Slides:



Advertisements
Similar presentations
Dr. Thaweesak Tirawatnapong Chula Medical Research Center (Chula MRC)
Advertisements

1 2 3 * Flow = cells in motion * Cyto = cell * Metry = measure * Measuring properties of cells while in a fluid stream * Flow Sorting * Sorting (separating)
Einstein Flow Cytometry Core Facility 2013 CFAR Retreat, January 15, 2013 Steven A. Porcelli, MD Scientific Director 416 Forchheimer, x3228
Pilot Implementation of Point-Of-Care CD4 Counting in Mozambique’s National Health System Ilesh V. Jani Instituto Nacional de Saúde Maputo, Mozambique.
Pediatric Diagnosis of HIV-1 Infection Using Dried Blood Spots Chin-Yih Ou, PhD NCHSTP/DHAP Centers for Disease Control and Prevention.
31.6 Diseases that Weaken the Immune System When the immune system is weakened, the body cannot fight off disease.
Reactive Oxygen Species (ROS) Mitochondrion and ROS Electron Transport Chain: Complexes I-V.
Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.
Cost Comparison of Point-Of-Care and Conventional CD4 Testing in Resource-Limited Settings Ilesh V. Jani Instituto Nacional de Saúde Maputo, Mozambique.
Evaluation of Point-Of-Care CD4 and Toxicity Monitoring for Resource-Limited ART Clinic Settings in Mozambique Ilesh V. Jani 1, Nádia Sitoe 1, Patrina.
MODELING THE PROGRESSION AND TREATMENT OF HIV Presented by Dwain John, CS Department, Midwestern State University Steven M. Shechter Andrew J. Schaefer.
Center of Excellence in Cancer Research Principles of flow cytometry
ACQUISITION RATES EFFECT ON MULTIPARAMETRIC RARE EVENT ANALYSIS : AN INSTRUMENT COMPARISON John Tigges, Vasilis Toxavidis, Heidi Mariani Beth Israel Deaconess.
Routine HIV Screening in Health Care Settings David Spach, MD Clinical Director Northwest AIDS Education and Training Center Professor of Medicine, Division.
Advancements in FACS analyzers optical design leads to greater functionality and a smaller footprint. INTRODUCTION In the past decade, instrumentation.
Model and Variable Selections for Personalized Medicine Lu Tian (Northwestern University) Hajime Uno (Kitasato University) Tianxi Cai, Els Goetghebeur,
Page 1 © J.Paul Robinson, Purdue University BMS 602 LECTURE 9.PPT BMS LECTURE 10x Flow Cytometry: Theory Bindley Bioscience Center Purdue.
MHRP  The views expressed are those of the authors and should not be construed to represent the positions of the U.S. Army or the Department of Defense.
Blocviroc – an innovative treatment for HIV/AIDS Steve English Development Head, Antivirals.
Preventing HIV/AIDS There is no way to tell just by looking whether a person is infected with HIV. Because people are unaware that they are HIV-positive,
COBAS TaqMan 48 Sales Brochure
ICCS e-newsletter CSI Summer 2011 Jeannine T. Holden, MD Emory University School of Medicine Atlanta, GA.
Automated analysis of cytometric profiles of synovial fluid and peripheral blood in rheumatoid arthritis Till Sörensen 1, Ursula Schulte-Wrede 2, Silvia.
Washington D.C., USA, July 2012www.aids2012.org HCV genotype and HBV co-infection associate with HCV clearance in HIV- positive subjects Yuan Dong,
Ilesh V. Jani, MD PhD Instituto Nacional de Saúde Maputo, Mozambique.
New Technologies and Innovations in Laboratory Support of HIV/AIDS Care and Treatment Sakchai Dettrairat HIV Laboratory Division of Clinical Immunology.
Overview Pediatric HIV Program & IMPAACT/ PACTG Vaccine Research Children’s National Medical Center, Washington, DC Dr.Hans ML Spiegel Director Special.
Estimating the Burden of Serious Fungal Diseases in Thailand Methee Chayakulkeeree 1, David W. Denning 2* 1 Division of Infectious Diseases and Tropical.
Development of a detuned oral assay for recent HIV infection F. Priddy 1, P. Phelan 1, P. Tambe 1,2, C. del Rio 1 1 Emory University School of Medicine,
House dust mite (HDM) is a common allergen and reactivity is associated with asthma and atopic dermatitis. The development of these allergic diseases depends.
Using HIV Surveillance to Achieve High Impact Prevention Irene Hall, PhD, FACE AIDS 2012 High-Impact Prevention: Reducing the HIV Epidemic in the United.
Management and Development for Health (MDH)
Introduction To Flow Cytometry By Noha Kamel. Flow cytometry is a method of measuring multiple physical and chemical characteristics of particles by optical.
Detecting Infectious HIV in Human Milk Miles W. Cloyd, Ph.D. Professor Department of Microbiology & Immunology University of Texas Medical Branch Galveston,
BNPCV APCCB BIOLOGICAL VARIATION FOR N-TERMINAL PRO-BNP Jones GRD 1, Bennett A 2,3, Boscato L 1, Macdonald P 2, Brien J 3. Departments of Chemical.
CDER Meeting: Surrogate Markers of Immunity Presenter: Judith A. Britz, Ph.D. October 16, 2000.
Absolute CD4+CD25+CD127low/- T Cells (Treg) in Peoples with HIV/AIDS
© Guidant 2005 Surrogate Endpoints and Non-randomized Trials Roseann White Humble Biostatistician.
Quality Controls: Get your instruments under control!
THE 6 TH NATIONAL SCIENTIFIC CONFERENCE ON HIV/AIDS Yield and impact of repeated screening for tuberculosis and isoniazid preventive therapy among patients.
Course: Research in Biomedicine and Health III Seminar 5: Critical assessment of evidence.
IMPROVING ECONOMIC PRESCRIBING IN A TEACHING HOSPITAL THROUGH AN EDUCATIONAL STRATEGY TO PROMOTE GENERIC PRESCRIBING.
Diana Careaga 1, Robert Magari 1, Karen Lo 1, Michael Keeney 2, Ben Hedley 2, Dominika Benjamins 2, Dr. You-Wen Qian 3, Larry Hinson 3, Cristina Ceja 3,
A Survival Comparison between HIV+ U.S.-born Latinos and Foreign-born Latinos in Houston, Texas Raouf Arafat, MD, MPH, Adebowale Awosika- Olumo.
HAEMATOLOGY LINE A.C.KAROBIA
Henry Masur, MD Bethesda, Maryland
PRESENTED AT THE 9TH IAS CONFERENCE ON HIV SCIENCE - PARIS, FRANCE
Presented to the AIDS 2016 Conference
EVALUATING STABILIZATION TUBES FOR STORAGE OF CD4 HIV POSITIVE SAMPLES AT KILIFI DISTRICT HOSPITAL, KENYA Nella Raphael Kalama.
Stability of whole blood over time for CD4 & Viral load determination in HIV infected persons. N. Sippy & A. Abayomi Ladymeade Reference Unit Laboratory.
Medical Laboratory Instrumentation
EVALUATION OF HEMOCHROMA POC Hb READER
Center of Excellence in Cancer Research (CECR)
Providing ARVs to children in resource limited settings
JONCKHEERE, Stijn 1; STEUR, Elise 1; BILLIET, Johan 1
Validating Definitions of Antiretroviral Treatment Failure in Malawi
FREQUENCIES AND PHENOTYPIC CHANGES OF DENDRITIC CELLS DURING ACUTE DENGUE VIRAL INFECTION Lertjuthaporn S1, Khowawisetsut L2, Keawvichit R1, Thitilertdecha.
Manual Red Blood Cell and White Blood Cell Counts
External Quality Assessment: Choosing an EQA program
Expansion of CD7low and CD7negative CD8 T-cell effector subsets in HIV-1 infection: correlation with antigenic load and reversion by antiretroviral treatment.
Tuda G Kemri/Wellcome Trust Research Program
ALT-803 administration increases peripheral blood cell counts of lymphocyte subsets in cynomolgus monkeys. ALT-803 administration increases peripheral.
Management and Development for Health (MDH)
Supplemental Figure untreated Rituximab Alemtuzumab
DCs induce the proliferation of autologous T cells.
Decreased Intraindividual HLA Class I Expression is due to Reduced Transcription in Advanced Melanoma and Does Not Correlate with HLA-G Expression  Jörg.
Fig. 1 Effect of preinfection β7Hi CD45RA−CD4+ T cell frequency on HIV acquisition risk in CAPRISA 004 study. Effect of preinfection β7Hi CD45RA−CD4+ T.
Flow cytometric gating strategy used to identify CD69 surface expression on CD4 (left paired columns) and CD8 (right paired columns) T lymphocytes. Flow.
Rapid Detection of HIV-1 subtype C Integrase resistance mutations by the Use of High-Resolution Melting Analysis Tendai Washaya BSc, Msc. Pre-PhD Student.
MDSC population in patient peripheral blood.
Presentation transcript:

1 Evaluation of two volumetric flow cytometers for the quantitation of CD4+ T-cells in Thai HIV-1 infected patients Yuwadee Phuang-ngern, Vallerut Pobkeeree, Surada Lerdwana, Egarit Noulsri, Nattawat Onlamoon, Somboon Nookhai, Kimberley Fox, Jordan Tappero, and Kovit Pattanapanyasat Office for Research and Development and Department of Immunology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand Thailand-Ministry of Public Health-U.S. CDC Collaboration, Nonthaburi, Thailand, and Global AIDS Program, Centers for Disease Control and Prevention, Atlanta, GA, USA.

2 42 Million People Living with AIDS Nature Reviews | Immunology Vol 3, 2003

3 Prognostic Monitoring of HIV Infection Absolute CD4 T-cell counts –Flow cytometric methods (Gold Standard) Single-platform technology Dual-platform technology –Non-flow cytometric methods Viral load Genotype, phenotype of drug resistance

4 CD4 Single Platform Volumetric method (Guava, CyFlow) *Number of cells / given volume of sample determined Non-volumetric method 1. TruCount, FlowCount, FACSCount *Beads are added in known numbers *Beads and cells are counted *Results are given as cells/beads and absolute counts are calculated 2. Flow rate based method (2003)

5 Three-Color SSC/CD45 Lymphocyte Gating Method Nicholson et al. Cytometry 1993;14: Pattanapanyasat et al. Cytometry 1994;18: BD MultiSET TM Software # of events in region containing subset population # of beads per pellet Absolute CD4+ count(cells/µl) # of events in absolute sample volume (µl) of subset population count bead region x = MMWR, 2003: 52(RR02);1-13 % CD4 X % Lymphocytes X WBC (from cell counter) = Absolute CD4+ count(cells/µl) Standard Flow Cytometric CD4 Methods Dual-platform method Single-platform method

6 FACSCalibur Flow Cytometer

7 FACSCount SYSTEM

8 FACSCount: A DEDICATED FLOW CYTOMETER Simple to use compact system Gold Standard method Absolute count & T % (infants?) One tube for CD4 is available Pipetting is the only critical step No generic reagent alternative Requires sheath fluid

9 System software and analysis

10 New Developments ● CD4 Cell Enumeration - CyFlow ® (Partec) - EasyCD4 TM (Guava) - PointCARE TM (PointCare Technologies) - LabNow (LabNow) ● Comparison to FACSCount or three-color bead-based flow cytometry

11 CyFlow green 1 Parameter

12 Measuring volume 200 µl True volumetric measurements

13 Volumetric Absolute Counting: Result Display Absolute CD4+ T-cell = N * dilution factor V

14 Evaluation of a new single-platform volumetric flow cytometer for enumeration of absolute CD4 T- lymphocyte counts in HIV-1 infected Thai patients Blood samples: 200 HIV-infected blood samples CyFlow green from Partec, Germany Compare with gold standard single-platform flow cytometric methods: FACSCount and FACS three-color Quality control: use Calibrite beads, CountCheck and Calibration beads for FACSort, FACSCount and CyFlow Statistical analysis: use linear regression analysis StatView and the Bland-Altman plot for bias analysis Pattanapanyasat K, et al. Clin Diagn Lab Immunol 2005;12:

15 Methods: Quality Control Within-run variation using CD-Check Plus CD4 Low stabilized whole blood samples showed less than 6% CV % CV of between-run variation over the period of study were less than 10%

16 A R 2 = 0.96 y = 0.81x R 2 = 0.97 y = 0.86x R 2 = 0.98 y = 0.93x – 5.3 D R 2 = 0.93 y = 0.79x R 2 = 0.95 y = 0.83x R 2 = 0.97 y = 0.95x Absolute CD4+ T-LymphocytesAbsolute CD8+ T-ymphocytes CyFlow green System TruCOUNT TM System CyFlow green System FACSCount TM System TruCOUNT TM System

Absolute CD4+ T-Lymphocytes Absolute CD8+ T-Lymphocytes Difference of the Two Systems (CyFlow green –TruCOUNT TM ) Difference of the Two Systems (CyFlow green – FACSCount TM ) Difference of the Two Systems (FACSCount TM –TruCOUNT TM ) Average of the Two Systems

Absolute CD4+ T-Lymphocytes Difference of the Two Systems (CyFlow green –TruCOUNT TM ) Difference of the the Two Systems (CyFlow green – FACSCount TM ) Difference of the Two Systems (FACSCount TM –TruCOUNT TM Average of the Two Systems

19 Discussion Disadvantages:  Need some manipulation  Problems on difficult samples  TB samples  Fluorochrome-protein ratio  Dim CD8+ T-cell  Integrity of volumetric probes  Accurate dispensing precision  Waiting for international approval

20 Benchtop Microvolume Cell Analysis Application Specific Software and Data Handling Green Diode Laser 36 cm 32 cm 21 cm Capillary Flow Cell Microliter Cell Samples Waste Fluid Dell Laptop Windows 2000 Pentium III 15.9 kilos with PC Guava Personal Cell Analyzer (PCA)

21 Absolute count = No. of cell count X dilution factor (20) Total volume acquired

22 Features Smaller sample volumes and reagents Smaller numbers of cells Minimized waste & expense –Reduces biohazardous waste 500-fold %CD4 T cells –CD4 T-cells as % of total lymphs –Suitable for pediatric HIV patients

23 Patients and Methods 250 HIV-1+ blood samples Equipments used in this study –TriTEST/TruCOUNT FACSCalibur –FACSCount –Guava system Quality control Statistical analysis Submitted for publication in Clin Cytometry

24 TruCOUNT TM Correlation of Absolute CD4 Guava Bland-Altman of Absolute CD4 (TruCount-Guava) Correlation of Absolute CD8 Guava TruCOUNT TM Results: TruCOUNT TM compare to Guava y = 0.99x R 2 = 0.95 y = 0.90x R 2 = 0.92

25 Results: FACSCount TM compare to Guava FACSCount TM Guava Bland-Altman of Absolute CD4 (FACSCount-Guava) Guava FACSCount TM Correlation of Absolute CD4 Correlation of Absolute CD y = 1.04x R 2 = 0.94 y = 0.91x R 2 = 0.88

26 Results: Bland-Altman Bias for Guava measurement Mean biases were 8.9 and 16.3 cells/μL at CD4+ T-cell counts below 200 cells/μL when compared to TruCOUNT and FACSCount Mean biases were 79.5 and 52.3 cells/μL for CD8+ T-cell counts when compared to TruCOUNT and FACSCount Guava system overestimates the other two bead-based systems

27 Discussion (1) Smaller sample volumes Smaller numbers of cells Minimized waste and expense –Reduces biohazardous waste 500-fold %CD4 T cells –CD4 Tcells as % of total lymphs –Suitable for pediatric HIV patients

28 Discussion (2) Disadvantages:  Equipment requires adjustment  Precision of pipetting  Problems on difficult samples  Leucopenic samples  Low CD3 samples  Dim CD8+ T-cells  Unable to distinguish CD3 and CD4 T-cells  Integrity of microcapillary flow cells  Waiting for international approval

29 Excellent correlation when compared to the two standard bead-based methods Overall %CD4 bias is less than 1% Bias of <8% or 8-16 CD4 cells/μl in patients with CD4<200 cells/μl Reduce the CD4 testing cost of $12-25 to less than $2-3 Save up to $3,000,000/year for national HIV treatment program in Thailand Conclusion

30 Acknowledgments Global AIDS Programs, Center for Disease Control and Prevention, Atlanta, GA, USA WHO HIV/AIDS Diagnostic Support, Health Technology and Pharmaceuticals Becton Dickinson Biosciences (Thailand) AIDS 2006 International Scholarship (ID 10001) Note: The findings and conclusions in this poster are those of the authors and do not necessarily represent the views of the Centers for Disease Control and Prevention