National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce Power Loading Effects in Precision 1  Resistors.

Slides:



Advertisements
Similar presentations
It is very difficult to measure the small change in volume of the mercury. If the mercury had the shape of a sphere, the change in diameter would be very.
Advertisements

Thermostats, Pressure Switches, and Other Electric Control Devices
Have you ever held a wire that has current flowing through it? If so what did you notice about it? The wire gets hot. The increase in temperature causes.
Evaluation of Load Cells for Legal Metrology at NIST Kevin Chesnutwood Mechanical Engineer Mass and Force Group Physical Measurement Laboratory.
1 Calibration of Thermometry Instruments Nihal Gunasekara Sri Lanka Bangladesh BEST Programme.
Semiconductor Input Devices
Single Phase Induction
Chapter Fourteen: Transmission Lines
CH 20-1.
Physics 121 Practice Problem Solutions 07 Current and Resistance
Chapter 5 LIQUID - IN - GLASS THERMOMETERS. “… the degree of their scales agree with one another, and their variations are within limits …” Daniel Gabriel.
Example 1:- An annular alloyed aluminum (k = 180 W/m . K ) fin of rectangular profile is attached to the outer surface of a circular tube having an outside.
Selection of measuring instruments
1 Fourth Lecture Static Characteristics of Measurement Systems (continued) Instrumentation and Product Testing.
Design Evaluation of Multiroll Mills for Small-diameter wire rolling Paper by K. Kuroda, T. Kuboki, Y. Imamura Presentation by Adam Slade Monday, 17 September,
Copyright © 2009 Pearson Education, Inc. Admin: No discussion sections this week. Register for MasteringPhysics Course ID: MPHOLDER67874.
Development of Legal Metrology Requirements for Electric Vehicle Fueling & Submetering V2G/PAP-22 Nashville, TN September 15, 2014 NIST USNWG on Electric.
Fuel Evaporation in Ports of SI Engines P M V Subbarao Professor Mechanical Engineering Department Measure of Useful Fuel …..
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
SENSORS AND TRANSDUCERS
© 2012 Pearson Education. Upper Saddle River, NJ, All rights reserved. Electronic Devices, 9th edition Thomas L. Floyd Electronic Devices Ninth.
Federal Aviation Administration AVIATION HEAT FLUX CALIBRATION STANDARD 2013 Triennial International Fire & Cabin Safety Research Conference Philadelphia,
Classification of Instruments :
© NMISA 2010 INTERNATIONAL ACTIVITIES AT THE NMISA HUMIDITY LABORATORY DURING 2009/2010 Deona Jonker.
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
RESISTANCE – OHM’S LAW Lesson 5. Resistance  The amount of current flow in a circuit, and the amount of energy transferred to any useful device, depends.
Lecture 12 Current & Resistance (2)
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
SPH3U/SPH4C Findlay ELECTRIC CIRCUITS Students will: Solve problems involving current, charge and time. Solve problems relating potential difference to.
Motor Testing (Motor Only)
Temperature Control Loop
INTRODUCTION TO MEASUREMENT
Chapter 31 Faraday’s Law.
 I1I1   R R R I2I2 I3I3 Lecture 11 Current & Resistance.
Cascade and Ratio Control
ANALOG CIRCUIT AND DEVICES 10/7/ Semester I 2013/2014 Course Code: EEE 3123.
1 / 24 Introduction Eccentricity effects INTI Buenos Aires Oliver Mack: Recommendation For The Revision Of Test Procedures For Load Cells In Legal Metrology.
Shipboard Technical Support (STS) Calibration Facility
REFRIGERATION Dr. Basavaraj K. Nanjwade M. Pharm., Ph. D Department of Pharmaceutics Faculty of Pharmacy Omer Al-Mukhtar University Tobruk, Libya.
Halliday/Resnick/Walker Fundamentals of Physics
EXAMPLE 4.1 OBJECTIVE Solution Comment
USE OF UNCERTAINTY OF MEASUREMENT IN TESTING ROHAN PERERA MSc ( UK ), ISO/IEC Technical Assessor, Metrology Consultant.
CfE Advanced Higher Physics
USING SCANNERS TO AUTOMATE CALIBRATION. APPLICATIONS FOR SCANNERS IN CALIBRATION 1: Removing lead changing when calibrating Multi-product & Multi function.
Date of download: 5/27/2016 Copyright © ASME. All rights reserved. From: Experimentally Validated Computational Fluid Dynamics Model for a Data Center.
1 Chapter 01 Measurement And Error. 2 Summary Instrument – a device or mechanism used to determine the present value of a quantity Measurement – a process.
Electrical Testers Basic test equipment used in today’s shops may include an analog type meter, a VAT (Volt-Amp-Tester), DMM (Digital Multimeter),
Advances in High Current and Resistance Measurements to 11,000 Amps and Higher Guildline Instruments Limited.
Fermilab’s TRAC Summer Experience Joshua Louis Naperville District 203.
2002 NCSL International Workshop and Symposium August 8, 2002San Diego, CA National Institute of Standards and Technology Technology Administration, U.S.
1 How Does Temperature Non-uniformity of an Annealing Furnace Affect SPRT Stability? Speaker: Mingjian Zhao Authors: Mingjian Zhao, Rose Heaton, Rong Ding,
Chapter 27 Current And Resistance. Electric Current Electric current is the rate of flow of charge through some region of space The SI unit of current.
100 μ  1  100  10 k  1 G  100 T  1 T  1 M  A Bridge for Scaling to High Resistance from the QHR Rand Elmquist (presenter) and Dean Jarrett (co-author)
The Course of Synoptic Meteorology
Single Phase Induction
TOPIC: ARMATURE REACTION ENROLLMENT NO:
ELECTRICAL MEASURMENT AND INSTRUMENTS
Date of download: 11/2/2017 Copyright © ASME. All rights reserved.
A presentation on Measurement of Winding Resistance and Insulation Resistance of 3 Phase 11 kV/ 433 V, 16KVA Oil cooled type Transformer PRESENTED BY:
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
TYPES OF ERROR Types of static error Gross error/human error
Design Evaluation of Multiroll Mills for Small-diameter wire rolling
The Internal Environment & Human Comfort
Chapter 25 Electric Currents and Resistance
DC Motors Starters and Breaking Methods
 Define: The stirring heating plate or heated stirring heating plate has been developed to heat and mix fluids contained in laboratory receptacles such.
A Sensitive Denaturing Gradient-Gel Electrophoresis Assay Reveals a High Frequency of Heteroplasmy in Hypervariable Region 1 of the Human mtDNA Control.
Measurements and Instrumentation
Quench calculations of the CBM magnet
Assurance of Cyber-Physical Systems via Reasoning and Data Visualization Connecting automated reasoning techniques with data visualization to efficiently.
Presentation transcript:

National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce Power Loading Effects in Precision 1  Resistors G. Jones and R. Elmquist Quantum Electrical Metrology Division NIST Electronics and Electrical Engineering Laboratory, Gaithersburg, MD

National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce Motivations At NIST our primary standards are compared to the quantized Hall resistance (QHR) standard approximately twice a year to achieve uncertainties of a few parts in At NIST our primary standards are compared to the quantized Hall resistance (QHR) standard approximately twice a year to achieve uncertainties of a few parts in This is accomplished through the use of several precision 1  resistors manufactured from 1975 through 1992 by the Australian National Measurement Laboratory (NML), using the resistance alloy Evanohm. This is accomplished through the use of several precision 1  resistors manufactured from 1975 through 1992 by the Australian National Measurement Laboratory (NML), using the resistance alloy Evanohm. Over the years, discrepancies that were not related to the drift in the value of the primary working standards and exceeded the Type A evaluation of standard uncertainty in the measurement systems have been measured. Some of these variations were believed to be due to power loading in the transfer resistors. Over the years, discrepancies that were not related to the drift in the value of the primary working standards and exceeded the Type A evaluation of standard uncertainty in the measurement systems have been measured. Some of these variations were believed to be due to power loading in the transfer resistors. ‡ Certain commercial equipment, instruments, or materials are identified in this paper to specify the experimental procedure adequately. Such identification is not intended to imply recommendation or endorsement by the National Institute of Standards and Technology, nor is it intended to imply that the materials or equipment identified are necessarily the best available for the purpose.

Overview and Background In the DCC system the current is applied continuously and its polarity is switched within milliseconds, which results in essentially 100% duty cycle. The current in the CCC systems is ramped from one direction to the other over a period of several seconds. In the DCC system the current is applied continuously and its polarity is switched within milliseconds, which results in essentially 100% duty cycle. The current in the CCC systems is ramped from one direction to the other over a period of several seconds. It has been shown that the temperature coefficient of an Evanohm coil varies along the length of the winding and if a temperature gradient is produced by loading, this can produce changes in the measured value of the resistance. It has been shown that the temperature coefficient of an Evanohm coil varies along the length of the winding and if a temperature gradient is produced by loading, this can produce changes in the measured value of the resistance. Several experiments were conceived to examine the possible basis for these discrepancies including humidity variations and power loading. Several experiments were conceived to examine the possible basis for these discrepancies including humidity variations and power loading. National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Humidity Tests The resistance elements of the NML resistors are open to the environment, and some NIST data indicated that their value might be sensitive to the relative humidity (RH) levels within the laboratory. The resistance elements of the NML resistors are open to the environment, and some NIST data indicated that their value might be sensitive to the relative humidity (RH) levels within the laboratory. To test this two NML resistors were measured at 35 % ± 5 % RH and then subjected to a change in humidity, using an environmental chamber which was maintained at 25 °C and 55 % RH. To test this two NML resistors were measured at 35 % ± 5 % RH and then subjected to a change in humidity, using an environmental chamber which was maintained at 25 °C and 55 % RH. The two NML resistors were removed from the environmental chamber and immediately measured to determine if there was any shift in the resistance values due to humidity changes. The two NML resistors were removed from the environmental chamber and immediately measured to determine if there was any shift in the resistance values due to humidity changes. This test was repeated at a humidity level of 17 % RH. This test was repeated at a humidity level of 17 % RH. The three NML resistors were placed in an auxiliary oil bath and the air space above the oil was then sealed and dry nitrogen was bubbled into the oil while the resistors were again measured for a period of one week. The three NML resistors were placed in an auxiliary oil bath and the air space above the oil was then sealed and dry nitrogen was bubbled into the oil while the resistors were again measured for a period of one week. National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Response of a NML resistor after exposure to different humidity levels National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Response of a NML resistor to 1 week soaking in dry nitrogen atmosphere National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Power Loading Tests A cryogenic current comparator (CCC) ratio of 100-to-1 was used for comparisons of 100  resistors against precision 1  resistors at 100 mA and 50 mA. The DCC II system was reconfigured using relays and shunt resistors so that the measurement current could be applied to several resistors only just before and during the period that they were being measured. This change in the system reduces the effect of self-heating prior to the measurement period and makes comparison with CCC measurements more meaningful. The Dcc II system was also reconfigured to run at 50 mA. The DCC I system can be used with an auxiliary oil bath that has a relatively high stirring speed and non-laminar oil flow. Resistance values measured in the main oil bath were compared to values measured at °C ± °C in the auxiliary oil bath National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Response of a Thomas-Type 1  resistor under power tests National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Response of an Evanohm 1  resistor under power tests National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Response of an Evanohm 1  resistor under power tests National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Differences between data from CCC system and DCC II system at 100 mA and 50 mA. National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Difference in data from CCC system and DCC II system at 100 mA versus first order temperature coefficient National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Difference between data from power-off tests and continuous power at 100 mA National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Difference in data from power-off tests and continuous power at 100 mA versus first order temperature coefficient National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Difference in data from power-off tests and continuous power at 50 mA versus first order temperature coefficient National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Differences between data from auxiliary bath and main bath of the DCC I system versus the first order temperature correction National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Results In general, placing the resistors in an auxiliary oil bath with increased oil flow tends to lower the measured value of the resistors. One explanation for these observations is that temperature gradients are set up in the resistance elements by the increase in power dissipation. The Evanohm resistance elements may be less homogeneous than the Manganin resistance elements, producing greater variation of the TCR in different sections of the wire. The product of TCR and the change in temperature, taken for different sections of the resistance element, may be larger in the Evanohm type resistors in some cases. National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Results In Thomas-type standards, lower power levels, lower duty cycle, or measurement from a cold start gives values of the resistance that are somewhat lower than those obtained by measuring the resistors under continuous 100 mA current. In the Thomas resistors, the resistors' positive temperature coefficients help explain the observed decrease in resistance with greater heat dissipation. National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce

Recommendations A recommendation would be to maintain the measurement current continuously in Thomas-type resistors for at least 15 min before they are measured, so that the resistor has time to stabilize. National Institute Of Standards and Technology Technology Administration, U.S. Department of Commerce