Condition Monitoring of Generators

Slides:



Advertisements
Similar presentations
Condition Monitoring Of High Voltage Machines By The Analysis of
Advertisements

Brian Parkhill Patterson Pd. 2A. What is alternating current? An electric current in which the direction of flow of the electrons reverses periodically.
WP3 High Availability Drives Electrical Machines and Drives Research Group University of Sheffield Dr. Georges El Murr
Inspection & Preventive maintenance of breakers
Chapter 13 AC Motors. Chapter 13 AC Motors Objectives Discuss the operation of an induction motor. Identify and explain the operation of various three-phase.
New Energy Horizons Opportunities and Challenges Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25,
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing.
Managing Director, HVPD Ltd
Developed by Niels Bogh March Objective At the end of the class you will be able to explain the differences of the three main types of flame safety.
Protection and Relay Schemes. Agenda  Introduction of Protective Relays  Electrical System Protection with Protective Relays  Conclusion.
Power System Fundamentals
Circuit Protection  Protective Devices – terminate current flow in a circuit.  Located in series within a circuit  Excessive current flow results from.
Partial discharge analysis of defective three-phase cables An overview of an ongoing project involving the generation and analysis of PD within distribution.
REFURBISHMENT OF SMALL HYDRO PLANTS Innovative small hydro technologies Waterpower XIII July 29, 2003 Hugo Carle, Eng. General Manager.
Hydrokinetic Turbine Featuring Variable Flux Generation October 1, 2009 Sean Curran Vanessa Kohler Erik Minnis Michael Perry C. Taylor Peterson Alex Quintal.
Wind turbine induction generator bearing fault detection using stator current analysis By School of Electrical and Electronic Engineering The University.
Generator Protection. Amount of Protection Rated power of the generator Ratio of its capacity to the total capacity of the system Configuration of the.
1 INTRUSION ALARM TECHNOLOGY DETECTION DEVICES. 2 INTRUSION ALARM TECHNOLOGY Detection devices can be either passive or active. Passive devices typically.
Presentation On Vibration Analysis
MONITORING AND FAULT DIAGNOSIS OF INDUCTION MOTORS
NEW TOOLS FOR DIAGNOSTIC MEASUREMENTS ON ELECTICAL ROTATING MACHINES
SCADA and Telemetry Presented By:.
CY3236A- PIRMOTION: Pyroelectric Infrared (PIR) Motion Detection Evaluation Kit (EVK)
Industrial Machine Control
Joseph Kälin direct: , mobil: For your customers: MICRONOR Fiber Optic Product.
Slide # 1 Velocity sensor Specifications for electromagnetic velocity sensor Velocity sensors can utilize the same principles of displacement sensor, and.
Motor Testing (Motor Only)
CHARGING SYSTEM Major Parts Battery                                               Alternator Regulator.
POWER SYSTEM PROTECTION
AC Generators (Alternators)
Power Quality Assessment on Wind Energy systems Presented By vivek kumar(pe610)
PRINCIPLES OF OPERATION
Measurement and Control. Control Systems A control system usually consists of a processor, a control program, interfaces and a device under the processor's.
R.G.A. Zoetmulder, S. Meijer and J.J. Smit
STEPPER MOTORS Name: Mr.R.Anandaraj Designation: Associate. Professor Department: Electrical and Electronics Engineering Subject code :EC 6252 Year: II.
EE 445 Course Presentation Power System Protection
Chapter 16: Synchronous Generators
Protection & Switchgear
ADT490 Panel Theory. 2 System Power Supply Grounding ‣ Circuit separates positive / negative from Ground ‣ Ground fault - resistance to ground ≤ 10 kΩ.
AUTOMATIC RAILWAY GATE CONTROLLING AND TRACK SWITCHING
What is POWERGRID??? The Power Grid Corporation of India Limited (POWERGRID), is an Indian state-owned electric utilities company headquartered in Gurgaon,
Submitted to: Submitted by:
A Presentation On Construction Of Turbo Generator
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Wind Turbine Power Plant. Sources ●
EFFECTS OF VOLTAGE IMBALANCE ON 3-PHASE INDUCTION MOTORS DESIGN TEAM 3.
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
Industrial Training Project on Turbo Generators
Senior Science Disasters Part 4: Warning Devices.
Control Engineering. Introduction What we will discuss in this introduction: – What is control engineering? – What are the main types of control systems?
Done by: Khalid Hijjawi Mohammad Massad.  Is an electrical instrument that measures electrical resistance, the opposition to an electric current. The.
ONLINE MONITORING APPLICATIONS OF POWER TRANSFORMER Deepak Subedi.
J. Ardila, R. Albarracín, J.M. Martínez-Tarifa, G. Robles.
Online monitoring applications for power cables Joona Mörsky.
What is thermal noise? Thermal noise in the resistance of the signal source is the fundamental limit on achievable signal sensitivity is unavoidable, and.
Internal Guide : Batch No : 4 Mrs.Punyavathi Madam
Generator Condition Assessment through EMI Diagnostics Doble Power Services.
PREPARED BY: Group-D Ramavat Nikunj ( )
SIGENTICS HV Series S-modyn
Electric Machine Induction Motor
Development of RCP Vibration Monitoring System using Power Line Analysis Method 정 재 천.
Quick help for fault location and reliable detection of defects
Motors 3 phase Induction Motor.
Quick help for fault location and reliable detection of defects
Systems and Control.
1. TURBOGENERATOR ROTOR WINDINGS
Systems and Control.
Presentation transcript:

Condition Monitoring of Generators ELEC-E8401 Condition Monitoring of Electrical Equipment Minna Luojus 25.4.2016 1/8

Introduction Generator – one of the prime devices in a power plant Fixing of a generator takes a long time The cost of lost production significant On-line continuous measurements Measurements and inspections during revisions On-line partial discharge (PD) monitoring system 25.4.2016 2/8

On-line Continuous Measurements 1/2 Vibration Measurements Several vibration measurement sensors installed Axial and Radial x/y Automatic controlling system Permitted vibration level exceeded → alarm Vibration too high → shut down command Temperature Measurements Temperature measurement sensors Temperature of generator windings is followed 25.4.2016 3/8

On-line Continuous Measurements 2/2 Protection Relays For generator and its electrical system In total approx. 30 different relays Generator over current, over voltage, reverse power, over frequency etc. Measurement of Shaft Movement Generator and turbine equipped with shaft movement measurement system Shaft movement affects on bearings function 25.4.2016 4/8

Condition Monitoring 1/3 Measuring of Isolation Resistance The isolation resistance of generator windings measured At least once a year – usually during revision or long shut down Mechanical inspections During generator revision, depending on the running hours of generator Breaking and cracs of different mechanical constructions Retaining rings, after 70 000 running hours (if old material used) Stator windings slots and end-windings, after 50 000 running hours Tan Delta Monitoring System 25.4.2016 5/8

Condition Monitoring 2/3 - On-line Partial Discharge (PD) Monitoring System Continuous acquisition and analysis of electrical discharges on an object interacted by voltage Early recognition of discharge phenomena Sensitively detects and analyses location and cause of PD Main components of the PD monitoring system: Couplers PD signal processor Data acquisition and analyzing system 25.4.2016 6/8

Condition Monitoring 3/3 - On-line Partial Discharge (PD) Monitoring System Signals originating in the insulation system decoupled by the couplers Three dimensions used in the processing result: Phase angle  (deg) Number of pulses n Apparent charge q (nC) Figures: Siemens, Partial Discharge Measurement Flyer, http://www.energy.siemens.com/br/pool/hq/services/industrial-applications/generators/EN-Generator-Partial-Discharge-Measurement-Flyer.pdf 25.4.2016 7/8

Conclusion Generator one of the main components in a power plant → Condition monitoring important! Normal on-line measuring system On-line continuous measurements Condition monitoring system Inspections and measurements during revision On-line partial discharge (PD) monitoring system 25.4.2016 8/8