1 Before degassing RGA head After degassing RGA head RGA scans of test dewar December 23, 2005 (PR and SP) Ion Gauge readings : Vacuum (with RGA off) before.

Slides:



Advertisements
Similar presentations
Gas Laws.
Advertisements

The Haber Process The Haber Process combines nitrogen from the air with hydrogen derived mainly from natural gas (methane) into ammonia. The reaction is.
19 Jun 031 Lamberston Removal and F0 Straight Section Vacuum Upgrade Mike McGee FNAL.
Safe Use and Operation of Vacuum Lines
Sessler Group Safety Talk Safe Operation of Vacuum System for Avoiding Danger of Liquid Oxygen Ren-Tsung Wu October 23 rd,
Bellow valve (trap&pump) Inside glove box. (Note: Ar glove box is not necessary, if you work with single crystalline organic materials like rubrene that.
SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES
Oxygen Production D. Crowley, Oxygen Production To know that oxygen is produced during photosynthesis Tuesday, May 19, 2015.
Unit 205: Cold water systems
AW Rayment & TW Clyne Department of Materials Science & Metallurgy University of Cambridge, UK Design and Commissioning of a Chamber for Controlled Atmosphere.
1. Pump down the chamber from the atmosphere pressure 2. Using RHEED to obtain diffraction images 3. Open the RHEED chamber or venting from high vacuum.
Gases Two More Laws Chapter 14. Dalton’s Law b The total pressure of a mixture of gases equals the sum of the partial pressures of the individual gases.
1. Safe Use and Operation of Vacuum Lines, UCLA Chemistry and Biochemistry 2.
Ion Source Test Stand Vacuum Control System Johnny Tang.
Dalton’s Law of Partial Pressures Chapter 11 – Section 2 - Physical Characteristics of Gases.
PRESSURE MEASUREMENT Low pr ( Below 1 mm of Hg)- manometer and low pr gauges Medium and low ( between 1mm of Hg 1000 atm)- Bourdon gauge and Diaphragm.
HONORS CHEMISTRY May 6, 2014.
1 AFPS. 2 AFPS: Automatic Floor Pressurization System This special application, which modulates the fan speed by means of a differential pressure sensor.
Are You Another Einstein? Take 5 minutes to answer this question in your notebook…
Left side compressor behind Left control box Right side compressor behind Right control box.
Quiz – Get out your notes!!. Quiz (10 questions) 1) Which law would you use if you were given only pressure and volume? 2) Which law would you use if.
1 Partial Pressure Pressure of individual gases in a mixture.
Methods in Surface Physics Experimentation in Ultra-High Vacuum Environments Hasan Khan (University of Rochester), Dr. Meng-Fan Luo (National Central University)
Homework Check (The Ideal Gas Law) 1.If I contain 3 moles of gas in a container with a volume of 60 L at a temperature of 400 K, what is the pressure inside.
Market Trends 29 Europeans US Car Wash Growth Forecast Europe 2-4% Annual Growth.
Title Page. Respiratory Intro You may be asking, what is the Respiratory system? Well, the Respiratory system is the system that helps you breath in and.
PIMS IN INSTITUTE FOR NUCLEAR STUDIES Brazing Andrzej Soltan Institute for Nuclear Studies.
Beam-based vacuum observations and their consequences Sergei Nagaitsev August 18, 2003.
Lewis Structures and Chemical Bonding. Valence Electrons The electrons that exist in the outermost electron shell of an atom We can determine the number.
DALTON’S LAW OF PARTIAL PRESSURE
ESD SYSTEM OVERVIEW Sample Holder plate Bias Filament Cu Sample 1 2 B-A gaugeRGA Bias Sample Electrometer Butterfly valve Pumping group Conductance Gas.
Reser- Voir Turbo Pump 1 Five- Fold Turbo Pump 2 Scroll Pump1 Scroll Pump2 Tgt. Cham- ber N2N2 H2H2 P2 P1 P3 P4 P5 P6 Panel Tgt. Cell V2V1 V3 V0 E0 E1.
EMAS Vacuum Testing June 2, 2011 Last 2 slides added after Feb 28, 2012 getter initiation Mike Watson.
AdV Vacuum system changes, Feb2010 ‘New stations’ generic Layout preliminary Cryotrap_NICryotrap_NE Cryotrap_WI Cryotrap_WE Cryotrap_DT ? Cryotrap_IB ?
Orsay, May 5th 2011EuCARD- WP IN2P3 Les deux infinis IN2P3 Les deux infinis Orsay, May 5 th 2011 EuCARD Meeting WP10.8: Plasma Discharge Cleaning.
Machine Status  Proton Source Commissioning and Studies 8/13-8/14: Linac & Booster Maintenance Period  Main Injector MI30 vacuum ○ Work continues to.
Cooling Test Results on fuzzy carbon substrate Setup in Lotima Room Used water/glycol mix (70/30 by wt) Neslab chiller to set temp Small pump to get the.
1. 2 Partial Pressure Pressure of individual gases in a mixture.
Status Report of the Review of Vacuum Systems and Procedures Tug Arkan, Allan Rowe 2/21/
AIMS AND OBJECTIVES PACKAGING
Outgassing Measurement of PEPII ByPass Beampipe Presented to LCLSII Acc Phy Mtg 4/6/2016 Dale K. Gill.
Cryo Pump Limitations Recent operating issues with helium Mick Mann ANSTO – Lucas Heights - Australia.
Upgrading the Data Processing for the Vacuum Furnaces Jennifer Case Northern Illinois University Mechanical Engineering Supervisor: Mayling Wong Technical.
Jari Koskinen 1 Thin Film Technology Lecture 2 Vacuum Surface Engineering Jari Koskinen 2014.
Evolution of Field Emission Characteristics Selected C100 Cryomodules Michael Drury.
Dalton’s Law of Partial Pressures
Balancing Equations P + + = O + + = GCSE/A Level Chemistry.
R1 Fundamentals of Refrigeration
Introduction and Goals
Vacuum At LLO 2016 SURF Udochu, Ogbonnaya LIGO-T
SAES Project: Combination of NEG module and sputter ion pump
K. H. Lee, H. Y. Lee, Young-Gi Kim, J. Yang, S. M. Yang, K.J. Chung, Y.S. Na and Y. S. Hwang Residual Gas analysis during Glow discharge cleaning, Baking.
Combustion BY AREEB.
Activation of molecular sieves
Action People Time [h] Shutting down the SR 2 1
Call to Fix Canon Pixma MX340 printer Error 5200
R1 Fundamentals of Refrigeration
Inside the NMR Spectrometer
INSTITUTE OF HIGH ENERGY PHYSICS
BASIC VACUUM PRACTICE.
NEG-coated gun: Black R30 arc at 227kV, white R30 arc at 164 after refurbishing and second bake Carlos Wednesday, August 10, 2018.
Answer is C. Reactivity DECREASES from right to left.
SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES
DO NOT OPEN YOUR BINDER UNTIL INSTRUCTED
Conservation of Mass (pages 13-14)
Oxygen Production D. Crowley, 2008.
26 Oct 2017 – May 2019 Well water level monitoring data
Presentation transcript:

1 Before degassing RGA head After degassing RGA head RGA scans of test dewar December 23, 2005 (PR and SP) Ion Gauge readings : Vacuum (with RGA off) before degassing 6.0 E-7 Torr Vacuum (with RGA on) after degassing 6.9 E-7 Torr Vacuum (with RGA off) after degassing 6.2 E-7 Torr Test dewar pressures (dewar completely empty) Dec 22 at 09:00 7.7e-7 torr

2 Scan parameters are: AMU’s range 20 points per AMU Scale factor and scan speed = 1 Waited for RGA to stabilize for 20 minutes. Pressures Before turning on RGA 5.1 E-7 After turning on RGA 6.0 E-7 Dec 27, :40 Test dewar (P.R.) Test dewar pressures (dewar completely empty) Dec 26 at 15:08 4.9e-7 torr

3 Dec 27, 2005 at 15:00 Pressure on ion gauge is 5.9 E-7 Pressure from RGA program (hard to see above) 4.5 E-7 Note different scale from previous graphs hydrogen water Nitrogen, carbon monoxide oxygen Carbon dioxide Turbo pump oil

4 Scan parameters are: AMU’s range 20 points per AMU Scale factor and scan speed = 1 Waited for RGA to stabilize for 20 minutes. Pressures from ion gauge: Before turning on RGA 1.67E-6 After turning on RGA 1.95E-6 Pressure from RGA head is : 2.2 E-6 Dec 28, :40 Test dewar (P.R.) (dewar oppened, o ring groove scored, restarted pumping at 12:00) Less oxygen now ? Test dewar pressures (dewar completely empty, o-ring grove scored) Dec 28 at 13:20 4.1e-6 Dec 28 at 19: e-6

5 Dec 29, :30 (PR,CK) Ion gauge pressure 9.5E-7 before RGA turn-on; 11.1E-7 after RGA turn on RGA derived total pressure is 1.4 E-6 - oxygen peak(at 32) is 2.54E-8

6 Dec Test Dewar 12:30 Ion gauge readings: RGA off = 9.6 E-7, RGA on=1.07 E-6 RGA derived pressure 1.4 E-6 torr Partial pressures at (2/hydrogen = 4.00e-7)(18/water=9.89e-7)(32/oxygen=2.18e-8)

7 Dec Test Dewar 10:30 Ion gauge readings: RGA off = 6.7 E-7, RGA on=8.0E-7 RGA derived pressure 9.8 E-7 torr Partial pressures at: (2/hydrogen = 3.53e-7)(18/water=7.02e-7)(28/Nitrogen=1.14E-7)(32/oxygen=1.85e-8)

8 Jan Test Dewar 10:55 Ion gauge readings: RGA off = 3.58E-6, RGA on=3.9E-6 RGA derived pressure 3.9E-6 torr Partial pressures at (2/hydrogen = 1.23E-6)(18/water=3.18e-6)(28/Nitrogen=4.0E-7)((32/oxygen=2.54e-8) Test dewar was oppened at 11:00 of Dec 30 Italian purity monitor (cleaned, baked for 2 hours at 150F by Walter Jaskierny) was put in. Pumping started at 12:30 of Dec 30 Dec 30 at 13:30 pressure is 5.3e-5

9 Jan Test Dewar 12:30 Ion gauge readings: RGA off = 3.20E-6, RGA on=3.42E-6 RGA derived pressure 2.6e-6 torr Partial pressures at (2/hydrogen = 1.08e-6)(18/water=2.55e-6)(28/Nitrogen=3.80e-7)((32/oxygen=2.47e-8) With these settings each pass takes 5 minutes

10 Test Dewar pressure history with cleaned Italian purity monitor inside Dec 30 13: e-5 torr Dec 31 06: e-6 Jan 1 (2006) 11: e-6 Jan 2 10: e-6 ; Jan 3 07: e-6 ; Jan 3 12: e-6 ; Jan 4 12: e-6 Same as previous page but ion gauge is turned off (for 30 minutes) NOTE This is the only scan in this document until now taken with the ion gauge off !!!! RGA derived pressure is 2.6 e-6 Partial pressures at (2/hydrogen = 4.80e-7) (18/water=2.53e-6) (28/Nitrogen=2.15e-7) ((32/oxygen=2.54e-8)

11 RGA derived pressure is 2.6 e-6 IG pressure is 2.70 e-6 Partial pressures at (2/hydrogen = 8.62e-7) (18/water=1.99e-6) (28/Nitrogen=2.74e-7) (32/oxygen=2.05e-8) January 4, :45 RGA derived pressure is 2.5 e-6 Partial pressures at (2/hydrogen = 4.54e-7) (18/water=2.06e-6) (28/Nitrogen=1.97e-7) (32/oxygen=2.25e-8) IG pressure is 2.58 e-6 At 16:00 of January 4 theTest dewar pumping stopped. The next step will be removal of the purity monitor and installation of the double o-ring system. Ion gauge is turned on Ion gauge is turned off