Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview
Plant Wide Controller. The Plant Wide Controller TM (PWC) is a state-of-the-art boiler sequencing, control and monitoring system. The PWC combines innovative ease of operation, communication and expansion capabilities with boiler application expertise. Off-the-shelf, standard modulating Lead- Lag applications can be expanded to control circulating water variable speed pumps and isolation valves while monitoring the flame safeguard and boiler control systems.
Easy to Operate Key Lockable Door Security
Easy to Operate Hardwired Control Switches & Indications: Boiler On-Off-Auto Status Indications Firing Rate Control Dial Firing Rate Auto / Man % Bargraph
Easy to Operate Easy to use displays for: Boiler Plant Control & Monitoring Historical Trending Alarm & Event Handling Boiler Plant Setup LCD Graphic Display and Keypad
Easy to Operate q Home Page - Boiler Overview Display Arrow Keys - Move Cursor Menu, Page Up, Down - Display Selection Alarm List - Alarm, Event Display q Alarm Silence PB Display Keys
Home Page Lead / Lag Control Start Qty Control Sequence Control Custom Lead Rotate Alarm Status Time / Date Stamped Header Status Pressure / Temperature Setpoint Outside Temperature Status Started Boilers Warming Boilers Modulating Boilers Tripped Boilers
Alarm & Event Summary q Up to 200 Alarms & Events q First in - First out q Operator Actions q Events q Alarms q Time & Date Stamped
Historical Trending q An Essential Monitoring Tool q Multiple(4) Pen “Charts” q 8 min, 40 min., and 2, 8, & 24 hour charts 8 channel, 2 Hr Historical Memory - Standard 32 Mb Historical Memory - Optional 32 ch AI + 32 ch DI every 15 seconds for 30 days 90 or more days for less channels with low activity (depends on data compression efficiency)
Easy Set Up Fill In The Blanks Boiler Sequence PID Tuning Outdoor Reset Setup Day / Night Setback Day / Week Setback Week / Year Setback
Outdoor Reset / Setback Temp. Easily Configured: Normal Setpoints Setback Setpoints High & Low Limits Outdoor Cutoff Automatic Graphical Representation
Expandable PWC Front Door Open (2 to 5 boiler lead / lag configuration shown with three spare slots)
CPU Board q (2) Analog Inputs (4-20 mAdc /Thermistor) q (1) Relay Output (SPDT, 8A) q (1) RS232 programming Port q (1) Isolated RS485 Port (Modbus or Bacnet Option) q (1) Telephone Modem Option Card Dial in or dial out, 33.6 kb, RJ-11 jack, Data and Pagers q (1) Printer Port (Alarms / Logs)
Discrete Input q (15) Inputs, 120 Vac, optically isolated q (5) groups of isolated neutrals q (15) LED status indications q (2) 2A / 120 Vac Fuses
Hand-Off-Auto Relay Output (5) Relay Outputs (8A inductive, 1/2 Hp, 120 Vac) (5) Hand-Off-Auto Toggle Switches Toggle Switch is directly wired into output circuit. (5) LED's for Output ON / OFF (5) LED's for ”Call for Operation” (2) 2A / 120 Vac Fuses
Auto/Manual Analog Output q (5) Modulating Analog Outputs q (5) Auto-Manual Toggle Switches "Manual" hardware overrides CPU Bumpless Manual to Auto Transfer q (5) 0-100% Output Control Knobs q (5) 0-100% Output Bargraphs q Requires (1) Output Card per active channel, Any combination of 4-20 mA and 135 ohm cards
Analog Input (8) UNIVERSAL Inputs Switch Selectable as: 2 wire 4-20 mA, with internal 24 Vdc Thermistor, -60F F Thermocouple, Type J, F, 0-5 Vdc, potentiometers and other signals Pulse, 0.6 ppm Hz, 0-15 Vdc pulsers for Oil, Gas, Water, & kWh meters Enables Fuel Budget Fuel Consumption Tracking (8) LED status indications Power Ouputs and Signal Inputs are short circuit protected
Relay Output q (8) Isolated Relay Outputs ( 8A inductive, ½ Hp, 120 Vac) (2) SPDT, (6) NO-SPST q (8) LED status indications q (2) 2A / 120 Vac Fuses
Communications To Customer’s Building Automation Systems (Modbus / Bacnet) Diesels Chillers etc. Boilers (Modbus / Bacnet) Pagers
q Communications Modbus communication to BAS or SCADA Dial In From PC Dial Out to Alpha Numeric Pager Advanced Communication Capability
Dial In From PC
Availability Hard Service Manual Every Boiler Start / Stop Command & Firing Rate can be set manually in the unlikely event of a CPU hardware failure or software corruption A CPU failure will not prevent central manual control of the boiler plant This is a UNIQUE FEATURE! Fault Monitoring Analog Inputs (thermisters, 4-20mA signals) are monitored & LED used to show fault status
Installation 3/4” conduit connections Screwed fast Cable Tie Downs Power Fuses Spare Terminals (typical) Physical Separation Between Operation and Wiring
Custom Blockware
Custom Displays
Custom Charts