1 Alhussein Abuhoza, S. Biswas, U. Frankenfeld, J. Hehner, C. Schmidt GSI, Darmstadt, Germany and H.R. Schmidt University of Tübingen, Germany Construction.

Slides:



Advertisements
Similar presentations
HEAT EXCHANGER GUIDED BY: PREPARED BY:
Advertisements

1 Ann Van Lysebetten CO 2 cooling experience in the LHCb Vertex Locator Vertex 2007 Lake Placid 24/09/2007.
E/π identification and position resolution of high granularity single sided TRD prototype M. Târzilă, V. Aprodu, D. Bartoş, A. Bercuci, V. Cătănescu, F.
sTGC for ATLAS Small Wheel upgrade
Aging, High Rate and Shielding L. Lopes Lip-Coimbra.
Experimental Investigation of Gas Lift Instability and Dynamic Regulation to Control It Author/presenter: Christer Andre Larsen, NTNU Co-author:
Hydraulics.
D. Martinez, L. Waxner R. Presura Jets on a Stick University of Nevada Reno Nevada Trawatt facility Location of Authors #2 Shot #Array TypeCW diam.CW MatOW.
PRR TRD COOLING A. Marín (GSI) 7/01/2004 ALICE PRR TRD COOLING P.Glässel, A.Marín, V.Petracek, J.Stachel, M.R.Stockmeier, J.P.Wessels ALICE PRR TRD COOLING.
PRODUCTION and CERTIFICATION of Multi Wires Proportional Chambers for the LHCb Muon System at CERN K.Mair for the LHCb Muon Group CERN* Poster anlässlich.
1 Alhussein Abuhoza, S. Biswas, U. Frankenfeld, J. Hehner, Ch. Schmidt GSI, Darmstadt, Germany and H.R. Schmidt University of Tübingen, Germany Study of.
Abstract This paper presents an experimental investigation on the flexural failure behavior of RC Beams having different weight loss of 0, 5, 10 and 30%
M.Alfonsi 1, G. Bencivenni 1, W. Bonivento 2,A.Cardini 2,C. Deplano 2, P. de Simone 1, F.Murtas 1, D.Pinci 3, M. Poli-Lener 1, D. Raspino 2 and B.Saitta.
Progress with the TPC gas monitor Dariusz Antończyk Outline : Motivation Simulations Measurements Summary & Outlook.
FEE + ROC cooling S. Popescu CERN, U. Frankenfeld, H.R. Schmidt GSI.
Systematic studies on the rate capability of MWPC operated in Xe/CO 2 D. Gonzalez-Diaz for the CBM-TRD group March, 2008.
TRD R&D at GSI  Results from test beam 2004  Plans for test beam Feb. 06  Measurements with X-ray stand C. Garabatos, GSI.
Calliope ENEA Casaccia MON = monitor MWPC (CH1) T1 = test MWPC (CH3) T2 = test MWPC (BTF,CERN1,CERN2) T = temperature sensor P = atmospheric.
First results of an aging test of a full scale MWPC prototype for the LHCb muon system Workshop on “Aging Phenomena in Gaseous Detectors”, October 2-5.
This study has been performed with an apparatus consisting of two identical standard MWPCs, a clean gas system, an outgasing box, a Copper X-ray generator.
RESEARCH and DEVELOPMENT for CBM (at LHE JINR) Yu.V. Zanevsky Laboratory of High Energies JINR, Dubna - NEW INFRASTRUCTURE - FAST GAS DETECTORS - DIPOLE.
Experimental part: Measurement the energy deposition profile for U ions with energies E=100 MeV/u - 1 GeV/u in iron and copper. Measurement the residual.
1 A.Andronic 1, H.Appelshäuser 1, V.Babkin 2, P.Braun-Munzinger 1, S.Chernenko 2, D.Emschernmann 3, C.Garabatos 1, V.Golovatyuk 2, J.Hehner 1, M.Hoppe.
Lab tests of Thick GEMs (THGEM) Lab tests of Thick GEMs (THGEM) S. Dalla Torre, Elena Rocco, L. Ropelewski, F. Tessarotto May – August 2007.
Test mass charge relaxation V.P.Mitrofanov, P.E.Khramchenkov, L.G.Prokhorov Moscow State University.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
Progress on the beam tracking instrumentation Position measurement device Tests performed and their resolution Decision on electronics Summary.
E.Guschin (INR,Moscow) 3 May 2006Calorimeter commissioning meeting Status of PRS/SPD detector Cosmic test results Installation/tuning of monitoring system.
Global Tracking for CBM Andrey Lebedev 1,2 Ivan Kisel 1 Gennady Ososkov 2 1 GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany 2 Laboratory.
Muon detection in the CBM experiment at FAIR Andrey Lebedev 1,2 Claudia Höhne 1 Ivan Kisel 1 Anna Kiseleva 3 Gennady Ososkov 2 1 GSI Helmholtzzentrum für.
Radioactive source and cosmic-ray test for the MWPC Davide Pinci on behalf of the Frascati-Roma1 MWPC group.
1 Monophase Measurements on Prototype Pixel Structures D. Bintinger, M. Gilchriese, J. Taylor and J. Wirth and contributions from D. Cragg, E. Perrin and.
Gas Quality Checks Maria Luisa Porto Oriented by: Burkhard Schmidt 23/02/2009.
PERFORMANCE OF THE PHENIX SOUTH MUON ARM Kenneth F. Read Oak Ridge National Lab & University of Tennessee for the PHENIX Collaboration Quark Matter 2002.
30 October 2003V.Souvorov / B.Schmidt - MWPC PRR CERN site1 MWPC Aging Studies Outline: Overview of aging tests done Results in terms of gain variations.
Chamber Quality Control Before the construction several checks are performed on:  Panels (cathode and pad PCB)  GEM foil Tests on assembled detector.
M23 Inner Regions Upgrade with Triple-GEM detectors The EVLGG (Davide, Gianni & Ale) INFN Cagliari LNF Frascati INFN Roma.
Construction and Characterization of a GEM G.Bencivenni, LNF-INFN The lesson is divided in two main parts: 1 - construction of a GEM detector (Marco Pistilli)
Aachen Status Report: CO 2 Cooling for the CMS Tracker at SLHC Lutz Feld, Waclaw Karpinski, Jennifer Merz and Michael Wlochal RWTH Aachen University, 1.
Professor Eduardo Cabrera
Systematic studies on pellet beam production M.Büscher, A.Gerasimov, V.Chernetsky, P.Fedorets, A.Dolgolenko,V.Balanutsa, A.Boukharov, L.Gusev, S. Mineev,
GROUND SERVICING OF VARIOUS SUB SYSTEMS
GROUND SERVICING OF VARIOUS SUB SYSTEMS
The GOOFIE detector as a Ternary Mixture Monitor
Study of some aspects of straw tube detectors
Investigation of Heat Transfer in Stationary and Rotating Internal Cooling Channels with High Rotation Numbers Mandana Sheikhzad Saravani Saman Beyhaghi.
A slow control system for a
Saikat Biswas, A. Abuhoza, U. Frankenfeld, C. Garabatos,
U.Frankenfeld GSI Darmstadt
UK Dark Matter Collaboration
Performance of an Automated Water Based Cooling System for CBM MuCh
R. Guida PH-DT-DI Boston Students Program CERN, 16/1/2013
Aachen Status Report: CO2 Cooling for the CMS Tracker at SLHC
Alhussain Abuhozaa,b, S. Biswasb, U. Frankenfeldb, J. Hehnerb, C. J
Gas Detectors Aging Review
Simulation results for the upgraded RICH detector in the HADES experiment. Semen Lebedev1,3, Jürgen Friese2, Claudia Höhne1, Tobias Kunz2, Jochen Markert4.
The Compact Muon Solenoid Detector
24-30 May 2015, La Biodola, Isola d'Elba (Italy), Alhussain Abuhoza
MWPC prototyping and testing of STAR inner TPC upgrade
Date of download: 3/4/2018 Copyright © ASME. All rights reserved.
Recirculating CO2 System
THGEM report – january, 22nd 2009
Development of Gas Electron Multiplier Detectors for Muon Tomography
Performance of a Multigap RPC prototype for the LHCb Muon System
MWPC’s, GEM’s or Micromegas for AD transfer and experimental lines
November technical stop activities:
Pre-installation Tests of the LHCb Muon Chambers
Test of the cleaning gas mixtures.
Analytical parameters and optimization in RF-GD-OES
Measurements of Stability of Gas Electron Multiplier (GEM)
Presentation transcript:

1 Alhussein Abuhoza, S. Biswas, U. Frankenfeld, J. Hehner, C. Schmidt GSI, Darmstadt, Germany and H.R. Schmidt University of Tübingen, Germany Construction and commissioning of a setup to study ageing phenomena in high rate gas detectors TIPP14 Amsterdam ( )

 Introduction  What is the detector ageing?  Why ageing studies?  Ageing setup  Setup-I  Setup-II  Summary 2 Plan

3  Introduction  What is the detector ageing?  Why ageing studies?  Ageing setup  Setup-I  Setup-II  Summary

Symptoms Losses in gas gain Decrease of resolution or efficiency Excessive currents Etc... Detector ageing It is the deterioration of the detector performance. 4

5  Introduction  What is the detector ageing?  Why ageing studies?  Ageing setup  Setup-I  Setup-II  Summary

~1.5 C/cm 2 Estimated accumulated charge in the fourth layer of Muon Chamber (MuCh) in CBM Ex. in 10 years. ~300 C/cm 2 Estimated accumulated charge in the first layer of Muon Chamber (MuCh) in CBM Ex. in 10 years. ~300 C/cm 2 Estimated accumulated charge in the first layer of Muon Chamber (MuCh) in CBM Ex. in 10 years. ~11 C/cm 2 Estimated accumulated charge at TRD1 in CBM Ex. in 10 years. Experiment like Compressed Baryonic Matter (CBM) at future FAIR facility at Darmstadt, Germany needs detectors with long term (~10 years) stable operation at high rates. 6

7  Introduction  What is the detector ageing?  Why ageing studies?  Ageing setup  Setup-I  Setup-II  Summary

Ageing setup 1.Studying ageing phenomena of gaseous detectors. 2. Investigating the ageing properties of the materials used for the construction of gaseous detectors. 3. Monitoring the performances of gaseous detectors, in particular those used in CBM. 8

9 Setup-I Two MWPCs in serial were used in setup-I. A mixing station fids one gas line. One sensor for temperature and one for pressure. The MWPC configured of two cathodes (Al-Kapton foils) and on anode (multi-wire plane).

10 Setup-I (Test approach) t t Q Q MaMa MaMa MrMr MrMr Fully Automatic Ageing Chamber Reference Chamber High rate X-ray 55 Fe monitor X-ray Ageing Ch. Refernce Ch. Normalized gain ∑Q No ageing Ageing

Gain in MWPC 11 Ageing study : 1.Gain is the major parameter to monitor detector performance. 1.Gain normalization:  Gain ratio of two detectors (ageing and reference).  Extrapolating gas density effect by fitting approach (needs precise measurement of gas temperature and pressure). 2.Variation of normalized gain should be < 1% p/T G

12 1.Cathode of Al-Kapton foil has been replaced with a multi-wire plane 2. Premixed gas bottle will be used instead of a mixing station (temperature effect on the MFCs). 3.Moving platforms have to be presented (to avoid the continuous exposure of 55 Fe-source and to test two materials or more in parallel). 4.Metal housing of chamber instead of fiberglass. 5.Individual gas lines (to avoid any pressure drop in-between the chambers). Findings from setup-I [1] A Abuhoza, S Biswas, U Frankenfeld, J Hehner, CJ Schmidt, and HR Schmidt. Physics Procedia, 37:442–447, [2] A Abuhoza, HR Schmidt, S Biswas, U Frankenfeld, J Hehner, and CJ Schmidt. NIM Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2012.

 Introduction  What is the detector ageing?  Why ageing studies?  Ageing setup  Setup-I  Setup-II  Summary 13

Setup-II (components) 14

15 Setup-II Three parallel lines (two for ageing test, one reference). Premixed gas (no mixing station). Two motion platforms (collimator and chambers). Metal housing of the chambers. Multi wire anode + multi wire cathode. (components)

16 Setup-II

17 Setup-II (Gas system) Outgassing box Ageing material

18 Setup-II (Test procedure) motor CH-0 CH-2 CH-1 x-ray CH-1 CH-0 CH-2 t Normalized gain ∑Q ageing No ageing Fe 2.X-ray (filter)

19 Commissioning and ageing tests of setup-II  Ageing and recovery behavior in the first test.  Investigation of setup cleanness.  Improving of gain normalization.  Ageing tests.

Ageing and recovery behavior in the first test. In this setup all the components are new: + Detector Lab (D.L.) global gas-line + Mass flow Controller (MFC) + rigid steel tubes inside the lab + outgassing box (in line-1 and line-2) + flexible steel tube (inlet) + detector + flexible steel tube (outlet) 55 Fe 1mm 55 Fe+x-ray 1mm+3cm Effect of the high rate of x-ray ?? Where is the contamination source in the new setup?? ΔG=7% ΔG=4% 20

Investigation of contamination source 21

Investigation of contamination source (ΔG/G 0 ) CH-0 = 5% (ΔG/G 0 ) CH-1 = 11% Using two lines 22

Investigation of contamination source 23

Investigation of contamination source Two ageing tests using gas scheme-2 revealed that there is still a source of ageing. ΔG/G 0 = 2.5% Using one line ΔG/G 0 = 20% 24

Investigation of contamination source 25

Investigation of contamination source Gas system: ball gas flow regulator + flexible steel tube + flexible steel tubes (inlet) + detector + flexible steel tubes (outlet) + outgassing box (some tests) ΔG/G 0 = 5% 26

Investigation of contamination source 27

Investigation of contamination source Gas system: ball gas flow regulator + copper tube (inlet) + detector + copper tube (outlet) 28 Flexible tubes were cleaned by the supplier with a cleaning and degreasing agent is called commericialy “A062-K21 hebro®lan TN” contains: Phosphoric acid Alkyl alcohol ethoxylate Methylethyl ester Amins Alhkyldmiethyl N-oxides Flexible tubes were cleaned by the supplier with a cleaning and degreasing agent is called commericialy “A062-K21 hebro®lan TN” contains: Phosphoric acid Alkyl alcohol ethoxylate Methylethyl ester Amins Alhkyldmiethyl N-oxides

Investigation of contamination source Cleaning procedures of flexible tubes: 1.Distilled water, iso-propanol and dry air are pumped through the rigid and flexible tubes (without taking them out from the setup). 1.Ultrasonic bath + iso-propanol pumping. Gain variation = 0.3% ΔG/G 0 = 5% 29

 Improving of gain normalization. 30

RTV-3145 Al-tape (Gerband 705) Area=135 cm 2 R= 300 %/C/cm Area=135 cm 2 R= 3180 %/C/cm Ageing test of RTV-3145 and Al-tape (Gerband 705) 31

Summary 32  Precise measurement of ageing are necessary to implement studies in reasonable time and in real conditions.  Very clean and stable apparatus dedicated to ageing studies is operational in GSI DetLab.  Ageing acceleration by x-ray needs to be investigated.  Obtained gain stability is < 0.5% peak-to-peak.  Cleaning and degreasing agent “A062-K21 hebro®lan TN” reveals ageing effect on the MWPC.  Ageing test for two materials have been carried out (accelerated by x-ray generator):  RTV-3145 : R=3180 %/C/cm  Gerband 705: R=300%/C/cm

33

Back up 34

35 R= 960 %/C/cm 2, Q=0.117 C/cm 2 R= 92 %/C/cm 2, Q=0.037 C/cm 2

10 years = 10*2*30*24= h Q=e·n·r·G·t 36

37 Polyacrylat

Ageing tests: 1 min 1 min + 40 min x-ray Ch-2 Ch-1 Ch-0 38

Residual instability has been observed due to change in the gas density and detector geometry resulting from the change of ambient parameters (T, P etc.) 40

Modification in the design Inner windows Outer windows 41 To avoid the residual fluctuation of the gain resulting from the change of geometry of the chamber, extra outer windows have been added with two holes in inner windows Diethornís formula

Unstable proportionality of the gain with T/p ratio T/P (K/bar) Stable proportionality of the gain with T/p ratio T/P (K/bar) With outer windows Very stable operation after correction Unstable after correction Without outer windows 42