NATIONAL RESEARCH NUCLEAR UNIVERSITY (MEPhI) DEPARTMENT OF EXPEREMENTAL NUCLEAR PHYSICS AND COSMOPHYSICS MULTILAYER FILM SHIELDS FOR THE PROTECTION OF.

Slides:



Advertisements
Similar presentations
5 Current Field Measurement 5.1Alternating Current Field Measurement 5.2Direct Current Potential Drop 5.3Alternating Current Potential Drop.
Advertisements

GIANT MAGENTORESISCANCE AND MAGNETIC PROPERTIES OF ELECTRODEPOSITED Ni-Co-Cu/Cu MULTILAYERS.
Method of beam extraction from a synchrotron by the instrumentality of multilayer Cu-Fe shield Bondarenko Alexey.
Further development of modeling of spatial distribution of energetic electron fluxes near Europa M. V. Podzolko 1, I. V. Getselev 1, Yu. I. Gubar 1, I.
OUTLINE Introduction „Tera-to-Nano“: Our Novel Near-Field Antenna 80 GHz CW Frequency Domain Measurements Picosecond Pulse Time Domain Measurements 2D.
The planar Hall effect: sensor and memory applications Lior Klein Department of Physics, Bar-Ilan University The Itinerant Magnetism Laboratory – Department.
1 Optical Properties of Materials … reflection … refraction (Snell’s law) … index of refraction Index of refraction Absorption.
experimental platform
Studies of ADS by means of JINR Nuclotron Martin Suchopár Nuclear Physics Institute, Academy of Sciences of the Czech Republic Department of Nuclear Reactors,
Test of Silicon Photomultipliers (SiPM) at Liquid Nitrogen Temperature Yura Efremenko, Vince Cianciolo nEDM CalTech Meeting 02/14/2007.
CBM Superconducting Dipole Magnet
Precision Dispensing Purdue takes advantage of the gantry’s precision by fixing a 150 micron inner diameter dispensing tip to an EFD dispensing pressure.
Ion Beam Analysis Dolly Langa Physics Department, University of Pretoria, South Africa Blane Lomberg Physics Department, University of the Western Cape,
Founded in 1906 by Nahum Kolmanok; 1913 – merging with bulb factory “Light”. As a result, “Russian electric lamp” manufacture was established; 1921 –
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
Ondřej Svoboda for the ECAL group HADES collaboration meeting XXV, 19 – 23 November 2012 GSI.
Doc.: IEEE /1011r0 Submission September 2009 Alexander Maltsev, IntelSlide 1 Verification of Polarization Impact Model by Experimental Data Date:
Research student: Gustavo A. Gandara Montano
Laser Treated Metallic Probes for Cancer Treatment in MRI Systems July 08, Advance Materials Processing and Analysis Center (AMPAC) Department of.
ETH Zurich Institute for Building Materials (IfB), Wood Physics Group © ETH Zürich Solid wood panels – a.
Effect of HSMF on Electrodeposited Ni-Fe Membrane-- Crystal Morphology and Magnetism Performance Yunbo Zhong, Yanling Wen, Zhongming Ren, Kang Deng, Kuangdi.
Cross-sections of Neutron Threshold Reactions Studied by Activation Method Nuclear Physics Institute, Academy of Sciences of Czech Republic Department.
MAGNETIC NOISE EFFECT ON THE GRAVITROPIC REACTION OF PLANTS AND AMPLITUDE AND SPECTRUM OF MAGNETIC FIELD NOISE GENERATED BY PLANTS DURING THEIR GROTH Sheykina.
M. Bianco On behalf of the ATLAS Collaboration
Coherent Diffraction Radiation experiment Konstantin Lekomtsev, Grahame Blair, Gary Boorman, Pavel Karataev, Maximilian Micheler John Adams Institute at.
Applications of Integration Copyright © Cengage Learning. All rights reserved.
The Structure and Dynamics of Solids
Ondřej Svoboda Nuclear Physics Institute, Academy of Sciences of Czech Republic Department of Nuclear Reactors, Faculty of Nuclear Sciences and Physical.
Neutron production in Pb/U assembly irradiated by deuterons at 1.6 and 2.52 GeV Ondřej Svoboda Nuclear Physics Institute, Academy of Sciences of Czech.
Scintillators suitable for PET applications must be characterized by a high efficiency for gamma-ray detection, determined by a high density and atomic.
Magnetic Shielding and Creation of homogeneous magnetic field (1 st presentation) Research student: Gustavo A. Gandara Montano Supervisor: Bertalan Juhasz.
By Abdullah Framalawi Aly Abouhaswa Polarized Neutron Spectrometry : Studying nanostructure magnetism with the use of polarized neutron reflectometry.
DESCRIPTION OF PIXIRAD  The PIXIRAD Imaging Counter is an INFN-Pisa Spin-off  It works in photon counting  Pulse discrimination with two thresholds.
Effect of small (2G) external B-field on standard PMT for magnetic moment experiment Chunyang Ding and Zhanpei Fang.
Neutron production and iodide transmutation studies using intensive beam of Dubna Phasotron Mitja Majerle Nuclear Physics Institute of CAS Řež, Czech republic.
NUCLEAR FRAGMENTATION STUDIES WITH ANTIPROTON-NUCLEUS ANNIHILATIONS J. Kawada on behalf of the AE g IS collaboration. Albert Einstein Center for Fundamental.
Fm "Field Line" Search Revisited Felix Meier "Field Line" Search Revisited Felix Meier GmbH7/16/20141.
Thermal screen of the cryostat Presented by Evgeny Koshurnikov, GSI, Darmstadt September 8, 2015 Joint Institute for Nuclear Research (Dubna)
Transverse Coherent Transition Radiation (TCTR) Experiment First Ideas for a Measurement Setup Max-Planck-Institute for Physics Munich Olaf Reimann, Scott.
Three years of cross-section measurements of (n,xn) threshold reactions at TSL Uppsala and NPI Řež O. Svoboda, A. Krása, A. Kugler, M. Majerle, J. Vrzalová,
A Temperature Compensated Power Supply for Silicon-Photomultiplier
Electromagnetic Testing (ET). Electromagnetic Testing Electromagnetic testing is a general test category that includes Eddy Current testing (ECT), Alternating.
Biot-Savart Law Performing various measures to study the magnetic field intensity variations around an inducting coil.
WELCOME TO GOTOGUIDE.
Borisenko L.A.1 , Malikova A.S.1 ,
A 3D design model of the apparatus for the Laser Wakefield Acceleration of electrons at ELI-NP S. Balascuta1 , R. Dinca1 1) “Horia Hulubei” National.
Studies at BINP Alexander Krasnov
Belarus National Academy of Sciences
MDT second coordinate readout: status and perspectives
Frontier Detectors for Frontier Physics
ELECTROMAGNETIC CANNON
5. Strain and Pressure Sensors
with operating voltage
Vladimir Rykalin NRC KI IHEP Baksan - 50, Nalchik, June, 2017.
Status of the CERN chopper.
Second SPL Collaboration Meeting, Vancouver May 2009
Cross-section Measurements of (n,xn) Threshold Reactions
BAHIRDAR UNIVERSTY COLLEGE OF SCIENCE DEPARTMENT :MATERIAL SCIENCE AND ENGINNERING PRESENTETON ON: ELLIPSOMETRY INSTRUMENT PREPEARED BY :ZELALEM GETU AMSALE.
35th ICRC, Busan, Korea, July 2017
A.S. Ghalumyan, V.T. Nikoghosyan Yerevan Physics Institute, Armenia
Proposals of new electron cloud monitor in the PS
7 Applications of Integration
Image construction. Image construction. (A) Step 1: Slice selection. A slice-selecting gradient (GS) is applied at the same time as the excitatory radiofrequency.
The electromagnetic rotation of water
O. Svoboda, A. Krása, A. Kugler, M. Majerle, J. Vrzalová, V. Wagner
Applications of Integration
Antenna Theory Chapter.4.7.4~4.8.1 Antennas
Fig. 1 Slow FM fluctuations in the PM phase of EuCd2As2.
2nd Week Seminar Sunryul Kim Antennas & RF Devices Lab.
7 Applications of Integration
Presentation transcript:

NATIONAL RESEARCH NUCLEAR UNIVERSITY (MEPhI) DEPARTMENT OF EXPEREMENTAL NUCLEAR PHYSICS AND COSMOPHYSICS MULTILAYER FILM SHIELDS FOR THE PROTECTION OF PMT FROM CONSTANT MAGNETIC FIELDS V.V. DMITRENKO 7-th SHiP Collaboration Meeting CERN 10 – 12 February 2016

CONTENTS Multilayer film screens. The shielding characteristics of different types of screens. Shielding of PMTs by different screens. Conclusions.

MULTILAYER SCREENS First publications: Rucker A W 1894 Phil. Mag (Theor.) Esmarch W 1912a. Ann. Phys., Lpz and 1912b. Ann. Phys., Lpz (Exper.) Advantages of multilayer screens were demonstrated in comparison with solid ones. Real application of multilayer screens started significantly later, when high intensity magnetic fields and elements sensitive to magnetic fields started to use in physical experiments

MULTILAYER FILM SCREENS Multilayer film shields (MFS), manufactured by the galvanic electrodeposition, were created at: - Scientific and Practical Center for Materials of National Academy of Science of Belarus and - National Research Nuclear University MEPhI. S.S. Grabchikov, L.B. Sosnovskaya and T.E. Sharapov, Multilayer electromagnetic shield // Patent RB, № on V.V. Dmitrenko, A.G. Batishchev, S.S. Grabchikov and et al. Multilayer shield to protect the photomultiplier tubes and the method of its application // Patent for an invention, RB № on

ELECTRODEPOSITED MULTILAYER FILM SHIELD. Structure of the multilayer film shield (MFS). Electrical: Au, Ag, Cu. Magnetic: Fe (20-22%)-Ni (78-80%) μ 0 = (1-3)*10 3, μ max = (1-5)*10 4 PMT-85 housing, covered with the electromagnetic shield based on multilayer film structures (above) and without electromagnetic shield (below).

CHARACTERISTICS OF SAMPLE SHIELDS Sample shield Magnet ic layer thickne ss (µm) Total number of magneti c layers Total thickness of magnetic layers (µm) Cu layer thickne ss (µm) Total number of Cu layers Total thickness of Cu layers (µm) Total shield thickness (µm) MFS MFS MFS Permallo y N/A 500

THE EXPERIMENTAL SETUP FOR STUDY OF MAGNETIC SHIELDS

THE SHIELDING EFFECT OF MAGNETIC SCREENS The distribution of the magnetic field along the longitudinal axis of the various shield’s types. 0 on the horizontal axis corresponds to the middle of the longitudinal size of the shield. The vertical line is the end of the cylindrical shield. The magnetic field (B 0 ) is directed perpendicular to a longitudinal axis of the shield.

THE SHIELDING EFFECT OF MAGNETIC SCREENS Shielding effectiveness of various shield’s types (in the middle of the shield) depending on the value of the external magnetic field directed perpendicular to the longitudinal axis of the shield.

PROTECTION OF PMT BY MAGNETIC SHIELDS OF DIFFERENT TYPES The scheme of experimental setup for the study of the screening effectiveness of PMT by different magnetic shields.

PROTECTION OF PMT BY MAGNETIC SHIELDS OF DIFFERENT TYPES Coordinate system of the photomultiplier tube.

PROTECTION OF PMT BY MAGNETIC SHIELDS OF DIFFERENT TYPES Dependence of the relative amplitude of the output signal of an unshielded PMT-85 on the magnetic field along the axes (X, Y) and parallel to the axis (Z).

PROTECTION OF PMT BY MAGNETIC SHIELDS OF DIFFERENT TYPES The relative amplitude of the PMT-85 output signal, for different types of shields, depending on the external magnetic field in the direction of the magnetic field perpendicular to the shield.

PROTECTION OF PMT BY MAGNETIC SHIELDS OF DIFFERENT TYPES Dependence of the amplitude resolution of PMT-85 pulses on the induction of magnetic field without shield and also with shields of permalloy and MFS № 1 - № 3, with direction of the magnetic field perpendicular to the Z axis.

MULTILAYER FILM SCREENS ADVANTAGES Advantages of multilayer film screens formed by electrolytic deposition in comparison with traditional multilayer permalloy foil shields: - higher shielding effectiveness at the same total thickness of the magnetically soft material. - possibility to screen units with complex configuration. - possibility to industrially manufactured. - reasonable cost in case of industrial production.

PROPOSAL Designed and manufactured optimized multilayer films screens based on electrolytic deposition technology for experiment SHiP. To start this process we need the following information: - types of PMT, which will be used in experiment SHiP (real samples are preferable). - the intensity of the residual magnetic fields at the location of the PMTs. - approximate total number of PMT in experiment SHiP. Application of commercially manufactured FMS will reduce the time required for installation of experimental equipment, and possibly financial costs!

THANK YOU FOR ATTENTION