1 CFS Utilities – What’s included in RDR for IR July 31 2007 CFS Utilities – IRENG WG C WATER COOLING: none. Unknown loads on IR. Only have water plants.

Slides:



Advertisements
Similar presentations
Nov. 17, 2008 ILC08 Global Design Effort 1 Americas KlyCluster Cost Analysis Overview Tom Lackowski RF & Sum reported by Peter H. Garbincius.
Advertisements

Nov. 07 DR-KOM-CFS 1 Damping Rings KOM Conventional Facility & Siting Overview Tom Lackowski Acknowledgment: Atsushi Enomoto, Jean-Luc Baldy, John Osborne,
9/17/07 ILC Detectors 1 Conventional Utilities Tom Lackowski.
Global Design Effort - CFS TILC09 and GDE AAP Review Meeting - Tsukuba, Japan 1 GDE ACCELERATOR ADVISORY PANEL REVIEW CONVENTIONAL FACILITIES.
1 Asian Region Mechanical Design ILC Mechanical & Electrical Review Masanobu Miyahara /KEK Atsushi Enomoto /KEK Masahito Huse /Nikken Sekkei 2012/3/21.
Global Design Effort Detector concept # Plenary introductory talk IRENG07 Name September 17, 2007.
November 17, 2008 ILC08 HVAC and VE Update November 17, 2008 ILC CFS Workshop 2008 Chicago Lee Hammond, Fermilab Global Design Effort.
LNG Hazards.
CONVENTIONAL ELECTRICAL TDR DESIGN Randy Wielgos March 22, 2012 ILC CFS Baseline Technical Review.
1 ILC Mechanical & Electrical Review Conventional MECHANICAL System Design Summary Emil Huedem, FNAL Lee Hammond, FNAL Parsons Mechanical Team (Tim Sheehan,
Global Design Effort - CFS Baseline Assessment Workshop 2 - SLAC Reduced Bunch Number 1 BASELINE ASSESSMENT WORKSHOP 2 CONVENTIONAL FACILITIES.
ILC Mechanical & Electrical Review Conventional Electrical System Americas Region Design Summary March 21, 2012 Randy Wielgos, FNAL Parsons Electrical.
1 HVAC OVERVIEW and VALUE ENGINEERING ITEMS August 13, 2008 CLIC Working Group CES Lee Hammond, Fermilab.
Value Engineering Session Air Treatment / HVAC November 27, 2007 Lee Hammond, FNAL CFS.
Global Design Effort Detector concept Plenary introductory talk IRENG07 Kurt Krempetz September 17, 2007.
First Considerations on CLIC Cooling System Ch. Martel, J. Inigo-Golfin TS/CV.
Central Region Discussion Power and Cooling GDE Beijing-CFS.
31, May 2007 ILC DESY 07 1 Surface Building Design Development Tom Lackowski GDE.
Cryogenic cavern in Asian site Conceptual design of the cryogenic system Layout of the cryogenic plant for site A & B New layout of the cryogenic system.
Global Design Effort 1 Conventional Facilities and Siting Overview A. Enomoto, J-L. Baldy, V. Kuchler GDE.
Global Design Effort - CFS for Asian Single Tunnel Configuration Design Progress Masanobu Miyahara KEK.
E Huedem, Nov ILC VALUE ENGINEERING SESSION of POWER & COOLING (Focus on Main Shaft 7) November 27, 2007 INFORMATION PHASE Conventional.
1 Process Water and Air Treatment 01 June 2007 Emil Huedem, Maurice Ball, Lee Hammond Fermilab.
Thomas Jefferson National Accelerator Facility Page 1 UITF Progress meeting Approved Labyrinth Fresh air pulled through “chicken wire” gate.
NUMI NuMI Review of the Infrastructure – W, G & V 20 July 2001 WBS Page 1 1 Infrastructure Review - W.B.S Water Systems Water Systems –Upstream.
LCC Linear Collider Collaboratio ILC - CFS 12 November 2013 LCWS13 Tokyo University 1 Site-specific CF design from TDR LCWS13, 12 November 2013 Atsushi.
Global Design Effort - CFS Baseline Assessment Workshop 2 - SLAC Positron Source Relocation 1 BASELINE ASSESSMENT WORKSHOP 2 CONVENTIONAL FACILITIES.
Conceptual Design Study - Cryogenic Requirements How to decide the layout of ILC cryogenic system Conceptual design of cryogenic system Layout of cryogenic.
Utilities 14 October 2008 Martin Nordby, Gordon Bowden.
BDS Magnet-Power System-Facility Optimization1 ILC BDS Kickoff Meeting Basis for Magnet, Power System and Cooling Facility Optimization Discussion Paul.
WP2 Superbeam Work Breakdown Structure Version 2 Chris Densham (after Marco Zito version 1 )
VENTILATION PRINCIPLE FOR THE DRIVE BEAM TUNNEL M Nonis – EN/CV – 28/7/2009 Already presented by C. Martel/ J Inigo Golfin on15 th October 2008 CLIC WORKSHOP.
SLAC_OCT07 BDS-KOM-CFS 1 Beam Delivery System & Interaction Region KOM Conventional Facility & Siting Overview Fred Asiri/SLAC Acknowledgment: Atsushi.
Global Design Effort1 September 20-22, 2006 MAC Review Power and Water breakout (mixed results) Marc Ross GDE.
27 Nov 07 VM Workshop Global Design Effort 1 ILC – Superconducting Linear Collider Marc Ross, Project Manager GDE Fermilab.
TDR Status of Asian CFS Team Part II: The ILC Baseline Reference Ch.SectionSubsectionsAuthor1 st draft 112: Asian Region Siting Studies Overview Location.
Global Design Effort - CFS TILC08 Working Group 1 - March 5, CFS Cost Reductions Conventional Facilities and Siting Group A. Enomoto, V.
Global Design Effort - CFS Damping Ring Baseline Technical Review 1 DAMPING RING BASELINE TECHNICAL REVIEW CONVENTIONAL FACILITIES AND SITING.
COOLING & VENTILATION FOR THE DRIVE BEAM TUNNEL M Nonis – EN/CV – 16/9/2009 CLIC TWO BEAM MODULES REVIEW
Process Water VE Updates (Main Linac Only) Emil Huedem FNAL ILC Meeting - CHICAGO Nov E. Huedem 2008.
3/20/11 ALCPG11 Global Design Effort 1 CFS Detector Hall Considerations Tom Lackowski.
Global Design Effort Working Group C Conventional Facilities Parallel Session IRENG07 V. Kuchler, A. Enomoto, J. Osborne September 19, 2007.
2005/06/22 ALBA Building Project David Carles Engineering Services Division - CELLS.
Global Design Effort Working Groups A & C Parallel Session Summary IRENG07 A. Herve, T. Markiewicz, T. Sanuki, Y. Sugimoto V. Kuchler, A. Enomoto, J. Osborne.
50% LBNE Concept Design WCD Infrastructure. Mechanical.
Mike Andrews May 10, Week 54 NuMI Activities Initial test controls on the MI65 RAW exchange skid Complete hydrostatic test of the MI65 exchange.
COOLING & VENTILATION PLANTS M. Nonis – CERN EN Department / CV Group Annual Meeting of the FCC study – Rome 14 th April 2016.
August 2007Andrea Gaddi, CERN Physics Dept. Detectors Infrastructures & Services Baseline to design detectors infrastructures. Tentative arrangement of.
ESS Cooling System - Interface with DTL 1 John Jurns Cooling System Engineer.
Global Design Effort - CFS ILC Integrated Design Meeting, DESY, May ML Single Tunnel Configurations In Deep Underground Accessed with Long.
This talk is not a summary of costs for conventional facilities This talk is Review of conventional facilities used by CDF Discussion of status of systems.
50% LBNE Concept Design LAr Infrastructure. Mechanical.
CFS EDR KICK OFF MEETING Air Treatment August 23, 2007 Lee Hammond, FNAL CFS.
E- source kick-off meeting e- Source RDR- Conventional Facility & Siting Overview Fred Asiri/SLAC.
Global Design Effort - CFS ILC CFS and Global Systems Meeting 1 ILC CFS AND GLOBAL SYSTEMS MEETING CONVENTIONAL FACILITIES AND SITING GROUP CFS.
ILC Utility Design Study for Kitakami-site
Liming Yuan, Alex C. Smith  Process Safety and Environmental Protection 
CBETA Technical Review
Conventional Facility & Siting (CF&S) Overview for the Positron Source
CFS EDR KICK OFF MEETING Process Water August 23, 2007
Detector Utility/Service Cavern
Americas KlyCluster Cost Analysis Overview
Summary of WG2 :CFS for staging
Part II: Integrated Design of Infrastructures
Detector Service Cavern for ILC
Detector Hall Tom Lackowski ILD Workshop 2011 LAL, Paris
COOLING & VENTILATION INFRASTRUCTURE
ILC CFS AD&I Daresbury Lab Summary
Maintenance at ALBA facility: Strategy for the conventional services
ILC - Global Design Effort
Presentation transcript:

1 CFS Utilities – What’s included in RDR for IR July CFS Utilities – IRENG WG C WATER COOLING: none. Unknown loads on IR. Only have water plants for BDS and BDS dumps, with BDS piping distribution envision to go thru the Service Cavern shaft. BDS scaled from Main Linac concept/cost. AIR: No requirement/details on IR. BDS tunnels assumed 85F to 90F (29-32C) at 55F (13C) max dewpoint at 88fpm air velocity based on ML tunnels, based on very small load to air, BUT this needs to be revisited. LIFE SAFETY SYSTEM/FIRE PROTECTION: None DRAINAGE AND SANITARY: None. Sump pumps in major shafts Area SystemLCW (MW)Chilled Water (MW) Total (MW) SOURCES e SOURCES e DR e DR e RTML MAIN LINAC BDS DUMPS360 TOTAL HEAT LOAD (MW)182

2 CFS Utilities – What’s included in RDR for IR July CFS Utilities – IRENG WG C POWER: IR Power not in the current totals Unknown power needs. Based on 3MVA scaled down from CMS.

3 CFS Utilities – What’s needed July Need to establish and understand other spaces in the IR (Surface areas and underground areas such as detector hall, Power room, service room, electronic rack room, shafts, other caverns, and their corresponding utilities criteria) CFS limited to conventional utilities such as conventional power, process water, chilled water, air (hvac), fire protection and safety system, drain and sanitary. Other utilities (argon, cryo, vacuum, nitrogen, detector cooling, other flammable gases etc) and are typically not by CFS July CFS Utilities – IRENG WG C

4 CFS Utilities – What’s needed July POWER:..Experimental Systems power requirements includes detectors, electronic, control rooms, etc...UPS (uninterruptible power supply) requirement?..Grounding, clean power and dirty power?..Miscellaneous Power – Receptacles, Required Voltages ?..Interface…conventional power up to where?..power in Watt (or MW) July CFS Utilities – IRENG WG C

5 CFS Utilities – What’s needed July PROCESS COOLING WATER:..System types, process water, warm LCW, chilled LCW?, chilled water (CHW) ? The more number of systems, the more cost impact...Temperature requirements (max allowable supply temperature) and tolerances? Supply temp limit vary by region (ambient condition) and no. of water loops and HX approach temperature..Heat loads to water – by system and area?..Water flow requirements and delta T ? To each system? Components?..Locations of water cooled components?..Interface?—water up to what connections ? Simplified RDR Main Linac Concept Process Water Distribution IR will be similar to this July CFS Utilities – IRENG WG C Surface

6 CFS Utilities – What’s Needed July AIR (HVAC): Temperature Requirements and tolerances ? More stringent =more costly Heat loads to air – by area ? Air flow requirements and delta T ? Humidity Requirements and tolerances? Pressure as compared to the assembly hall or tunnel or? Air exchange rates and purge requirements as it relates to heavier or lighter than air gas use ?Other system that may affect air ventilation/life safety (flammable gases, cryo, helium etc) July CFS Utilities – IRENG WG C

7 CFS Utilities – What’s Needed July Life Safety System/Fire Protection: Use of suppression gases, where, required volumes Sprinkler systems, foam, mist? Fire detection – spot type, VESDA, line type heat detection Other system that may affect air ventilation/life safety (flammable gases, cryo, helium etc) (see Alain Herve Jul 27 on reqmnts w.r.t. fire safety): July CFS Utilities – IRENG WG C

8 CFS Utilities – What’s Needed July Drainage and Sanitary: (most info come from CFS, but need to know system, services and other space that will impact this) Need design basis or best estimate of how many people during installation, operation, maintenance? July CFS Utilities – IRENG WG C

9 CFS Utilities – What CFS items in the service cavern* July *size just for the BDS? Power: transformers Process Water: Water pumps (for BDS & IR) LCW skids (for BDS & IR) Heat Exchangers and misc (BDS & IR) Air (hvac): Fancoils? Ductwork? Supply/Exhaust Fans Drainage/Sanitary: Sump Pump Toilet Facility?? What cannot be in the service cavern? Or what needs to be in the service cavern? July CFS Utilities – IRENG WG C