Biophysics of BOLD and common image artefacts Rhodri Cusack Overview Biophysics of BOLD signal -Neural > Hemodynamic > MRI Complications at each level.

Slides:



Advertisements
Similar presentations
Unwarping.
Advertisements

BOLD Imaging at 7T Mark Elliott CfN Symposium 4/9/2008.
Physiological Basis of the BOLD Signal Kerstin Preuschoff Institute for Empirical Research in Economics, University of Zurich Thanks for Slides and images.
Richard Wise FMRI Director +44(0)
The physiology of the BOLD signal
Basis of the BOLD signal
The BOLD Response Douglas C. Noll Department of Biomedical Engineering
Declaration of Conflict of Interest or Relationship
Fund BioImag : MRI contrast mechanisms 1.What is the mechanism of T 2 * weighted MRI ? BOLD fMRI 2.How are spin echoes generated ? 3.What are.
Introduction to Functional and Anatomical Brain MRI Research Dr. Henk Cremers Dr. Sarah Keedy 1.
Introduction to Functional and Anatomical Brain MRI Research Dr. Henk Cremers Dr. Sarah Keedy 1.
Opportunity to Participate EEG studies of vision/hearing/decision making – takes about 2 hours Sign up at – Keep checking.
Principles of MRI. Some terms: –Nuclear Magnetic Resonance (NMR) quantum property of protons energy absorbed when precession frequency matches radio frequency.
HST 583 fMRI DATA ANALYSIS AND ACQUISITION Neural Signal Processing for Functional Neuroimaging Emery N. Brown Neuroscience Statistics Research Laboratory.
Realigning and Unwarping MfD
Realigning and Unwarping MfD
JOAQUÍN NAVAJAS SARAH BUCK 2014 fMRI data pre-processing Methods for Dummies Realigning and unwarping.
EEG Experiment for Extra Credit Sign up on the sheet.
Principles of NMR Protons are like little magnets
fMRI introduction Michael Firbank
Opportunity to Participate
Structural and Functional Imaging Functional images tend to be lower resolution and fail to convey spatial information Pixels.
Predictive Modeling of Spatial Properties of fMRI Response Predictive Modeling of Spatial Properties of fMRI Response Melissa K. Carroll Princeton University.
Functional MRI Daniel Bulte Centre for Functional Magnetic Resonance Imaging of the Brain University of Oxford.
BOLD fMRI Cheryl Olman 4th year student Department of Neuroscience and
Principles of MRI Some terms: – Nuclear Magnetic Resonance (NMR) quantum property of protons energy absorbed when precession frequency.
Arterial Spin Labeling at 7T - Double Edged Sword
Measuring Blood Oxygenation in the Brain. Functional Imaging Functional Imaging must provide a spatial depiction of some process that is at least indirectly.
Magnetic Resonance Imagining (MRI) Magnetic Fields Protons in atomic nuclei spin on axes –Axes point in random directions across atoms In externally applied.
What are we measuring in fMRI? Caroline Catmur Jack Kelly.
Functional Magnetic Resonance Imaging.  All subatomic particles possess a property called ‘spin’  i.e. like a planet rotating on it’s axis  Magnetic.
Co-registration and Spatial Normalisation
BOLD Contrast: Functional Imaging with MRI
BOLD fMRI.
Biological Basis for the Blood Oxygenation Level Dependent signal.
Basics of Functional Magnetic Resonance Imaging. How MRI Works Put a person inside a big magnetic field Transmit radio waves into the person –These "energize"
Signal and noise. Tiny signals in lots of noise RestPressing hands Absolute difference % signal difference.
FINSIG'05 25/8/2005 1Eini Niskanen, Dept. of Applied Physics, University of Kuopio Principal Component Regression Approach for Functional Connectivity.
How well do we understand the neural origins of the fMRI BOLD signal? Owen J Arthurs and Simon Boniface Trends in Neuroscience, 2002 Gillian Elizabeth.
BOLD Imaging An Introduction to MRI Physics and Analysis Michael Jay Schillaci, PhD Monday, February 25, 2008.
Statistical Parametric Mapping
Statistical Parametric Mapping
Class 3: Neurons  BOLD 2012 spring fMRI: theory & practice.
FMRI – Week 4 – Contrast Scott Huettel, Duke University MR Contrast FMRI Graduate Course (NBIO 381, PSY 362) Dr. Scott Huettel, Course Director.
BOLD-Based fMRI or “The Stuff We Do With The 4T” Part I Chris Thomas April 27, 2001.
SPM Pre-Processing Oli Gearing + Jack Kelly Methods for Dummies
Origin of Negative BOLD fMRI Signals
Ch. 5 Bayesian Treatment of Neuroimaging Data Will Penny and Karl Friston Ch. 5 Bayesian Treatment of Neuroimaging Data Will Penny and Karl Friston 18.
What are we measuring in fMRI?
Statistical Parametric Mapping Lecture 2 - Chapter 8 Quantitative Measurements Using fMRI BOLD, CBF, CMRO 2 Textbook: Functional MRI an introduction to.
FMRI Methods Lecture8 – Electrophysiology & fMRI.
The linear systems model of fMRI: Strengths and Weaknesses Stephen Engel UCLA Dept. of Psychology.
Preprocessing: Realigning and Unwarping Methods for Dummies, 2015/16 Sujatha Krishnan-Barman Filip Gesiarz.
Electrophysiology & fMRI. Neurons Neural computation Neural selectivity Hierarchy of neural processing.
Principles of MRI Physics and Engineering Allen W. Song Brain Imaging and Analysis Center Duke University.
BOLD fMRI BIAC Graduate fMRI Course October 1, 2003.
Neuroimaging with MRI: combining physics and physiology to understand brain function Rhodri Cusack.
BOLD functional MRI Magnetic properties of oxyhemoglobin and deoxyhemoglobin L. Pauling and C. Coryell, PNAS USA 22: (1936) BOLD effects in vivo.
Latest Developments in fMRI Peter A. Bandettini, Ph.D Unit on Functional Imaging Methods & 3T Neuroimaging Core Facility Laboratory of Brain and Cognition.
Physiological correlates of the BOLD signal an Introduction.
BOLD Contrast: Functional Imaging with MRI
functional magnetic resonance imaging (fMRI)
COMPARISON OF OPTICAL AND fMRI MEASURES OF NEUROVASCULAR COUPLING
BIAC Graduate fMRI Course October 5, 2005
Jody Culham Brain and Mind Institute Department of Psychology
MRI Pulse Sequences: IR, EPI, PC, 2D and 3D
What do we (not) measure with fMRI?
Dynamic Causal Modelling
BASIS OF THE BOLD SIGNAL
Biomedical Imaging: Magnetic Resonance Imaging - Basics
Presentation transcript:

Biophysics of BOLD and common image artefacts Rhodri Cusack Overview Biophysics of BOLD signal -Neural > Hemodynamic > MRI Complications at each level - and what to do about them

Stimulus to signal Arthurs & Boniface (2002)

What aspect of neuronal activity determines BOLD response?? LFP (Logothetis et al, 2001) –Simultaneous BOLD FMRI & electrophysiological recording –Measured Local Field Potentials (pre-synaptic, input) and Multi Unit Activity (spiking, output) –Both provided reasonable fit to BOLD activity, but LFPs better Energy use/oxygen consumption (Hoge et al, 1999) –Used MRI to measure CBF & oxygenation –Found linear relationship Neurotransmitter (Attwell & Iadecola, 2002) –Assessment of energy use by different processes Spiking very energy expensive Most used by postsynaptic currents & action potentials –Argue hemodynamic response is driven by neurotransmitter signalling and not local energy use Glutamate/GABA?

Hemodynamic response (HDR) Increase in volume –Increase in volume throughout system, from arterioles to capillaries, venules & veins –Fastest and greatest response in arterioles (Vanzetta, Hildenshen & Grinwald, 2005) Large increase in flow Oxygenation –Initial de-oxygenation in capillaries (Vanzetta et al, 2005) –Then, flow increase leads to a increase in oxygenation relative to the baseline state (i.e., OEF decreases, Ogawa et al, 1990; Bandettini et al, 1997)

Influences on spatial distribution of HDR Spatial characteristics influenced by –Neurovascular coupling (Malonek & Grinvald, 1995) –Vascular plumbing & structure Intracortical vessels Pial network Larger vessels –Size of region activated (Turner, 2002) Larger regions may give signal from veins further away

Influences on temporal profile of HDR Temporal characteristics influenced by –By neurovascular coupling in arterioles/capillaries –Flow times Function of vessel size Blood velocity proportional to radius – much of delay in small vessels –Mixing due to laminar flow within vessels (de Zwart, 2005) Should include diffusion (Parrot) –Other effects (e.g., vessel size dependence of post-stimulus adaptation – Mandeville et al, 1999; Yacoub et al, 2006)

The Balloon Model Buxton, Uludağ, Dubowitz, Liu (2004) Similar elements incorporated into SPM’s DCM forward model

Hemodynamic-MRI coupling HDR affects MRI signal through several mechanisms (Hoogenraad et al, 2001) –Extravascular: reduced field gradients around venules & veins Reduced deoxygenation causes magnetic property (susceptibility) of blood to become more similar to surrounding tissue Reduced field gradients in GM & CSF –Intravascular change in T2* –Reduced phase mismatch between signal from inside and outside venules & veins –Change in blood volume Affected by parameters of MR acqusition –Field strength (higher field – more sensitivity, particularly to smaller vessels/capillaries) (Haacke, 1994; Yacoub et al, 2003) –Gradient echo vs. spin echo – latter insensitive to large vessels – less signal, but more spatially specific (Lee et al, 1999; Zhao et al, 2006)

Non-linearities in the BOLD signal measured linear Signal 0.25 s0.5 s1 s2 s20 s time (s) Stimulus timing BOLD Response Brief stimuli produce larger responses than expected Degree of non-linearity varies across space Neural in origin Slide adapted from Bandettini; Birn, Saad & Bandettini (2001)

Vascular artefacts Vascular structure can affect signal at many levels Vascular signal –Larger in magnitude –More noisy Cusack et al (in preparation) Group level –Large variability in venous structure reduces chance of bias –May be more important in case studies or MVPA/ functional localiser studies

Fields should be flat MRI scanners apply a strong magnetic field –3 Tesla at the WBIC Ideally, field should be homogeneous –Easy to arrange when it is empty, but ruined as soon as a head is put in Different materials act to strengthen (para) or weaken (dia) magnetic fields With Shaihan Malik

Field strength relative to 3 Tesla (parts per million)

Tackling inhomogeneneity artefacts Distortion –Optimise acquisition –Acquire fieldmaps & undistort –Distortion by movement interaction Put movement parameters into model Use Realign & unwarp (Andersson, 2001) Dropout –Optimise acquisition parameters (e.g., TE, slice orientation, voxel size) –Z-shimming –Use spin echo (Schwarzbauer) –Passive shimming (Wilson, Jezzard and colleagues; Cusack et al, 2004) –Choose the right subjects

Fieldmap undistortion: evaluation by eye StructuralEPI mean Undistorted EPI mean StructuralEPI mean Undistorted EPI mean Cusack, Brett & Osswald (2004)

Quantitative evaluation - shape match to structural scan - Measure similarity in shapes between structural scan and EPIs before and after undistortion - Use mutual information statistic Cusack, Brett & Osswald (2004)

Overlap across subjects Cusack, Brett & Osswald (2004)

Undistortion on data from Siemens Trio Shimming: apply corrective field gradients –Much better on modern machines –Higher order shims optimised automatically –Shims only optimised for volume being acquired in EPI Acquire smaller volumes Undistortion most important for regions near inhomogeneities

Comparative studies Watch out when comparing to other models –Field inhomogeneities vary dramatically Human vs. sphinx vs. supine

Passive shimming EPI BOLD Wilson & colleagues, FMRIB, Oxford; Cusack et al (2005)

Optimising parameters to reduce dropout From Rik Henson

Summary BOLD FMRI involves a complicated set of couplings –Be careful when interpreting effects, or comparing FMRI with other imaging modalities It can fail in many ways –Optimise acquisition and analysis –Perform proper quality control