Isolate isolated (A) Physically separated, electrically and mechanically, fromall sources of electrical energy. Such separationmay not eliminate the effects.

Slides:



Advertisements
Similar presentations
LIMITED APPROACH BOUNDARY
Advertisements

Electrical Safety Program. How Electricity Works Operating an electric switch is like turning on a water faucet. Behind the faucet or switch there must.
Arc Flash Boundary Qualified Persons, Safe Approach Distance. Determine the arc flash boundary and, if the boundary is to be crossed, appropriate arc-rated.
Best Practices: Rubber Insulating Gloves and Sleeves while Performing Distribution Power Line Tasks via the Live Line Tool Method.
CONTROL OF HAZARDOUS ENERGY “LOCKOUT/TAGOUT” (LOTO)
De-energization and Lockout
By: Aseem Aggarwal. Causes of Electrocution Fatalities Contact with Overhead Power lines Contact with Live Circuits Poorly Maintained Extension Cords.
Practice Statement The effective use of Isolate and Insulate equipment and procedures to provide the necessary level of safety when performing Live Line.
Presented by Environmental Health and Safety
Qualified Electrical Worker
Controlling Hazardous Energy
Best Practices.
© Evaluating Electrical Risk Factors Module 3.
Electrical Safety.
1a.  Exposed part  Live or energized part  De-energized part 1a.
Electrical Safety. Definitions v Exposed part v Live or energized part v De-energized part 1a.
A PRESENTATION ON LOCKOUT/ TAGOUT” (LOTO) BY ORILOYE JIDE 13/03/2015
Working On or Near Energized Conductors and FR Clothing.
Important Elements of Conducting an Effective Tailboard Meeting OSHA 29 CFR PART (c)
Global Marketing © Chevron 2009 Rev. 1 Electrical Safety Awareness Plus.
1 Insulate & Isolate Continuing Education Second Quarter 2016.
11 Rubber gloves and sleeves are a lineman’s first and foremost defense against electrocution For this reason rubber gloves and sleeves must be physically.
Lockout/tagout for authorized employee
Grounding & Bonding Introduce the module.
Lock Out / Tag Out The Control of Hazardous Energy
OSHA Electric Power Training Rules Qualified vs. Unqualified Employees
Lock Out & Tag Out.
Energy Control Procedures Lockout/Tagout 29 CFR
Control of Hazardous Energy Lockout/Tagout 29 CFR
OVERVIEW Control Of Hazardous Energy.
Electrical Safety Equipment
Qualified Electrical Worker
Hazardous Areas & Hazards of Electricity
Isolate & Insulate Continuing Education First Quarter 2018
Isolate & Insulate Continuing Education First Quarter 2018
Important Elements of Conducting an Effective Tailboard Meeting
LINE CLEARANCE TREE TRIMMING OPERATIONS Quad State Instructors, Inc.
Personal Protective Equipment
A4 Insulator Changeout.
OSHA’s Final Rule: Electric Power Generation, Transmission, and Distribution Electrical Protective Equipment Presented to: RESAP Area Administrators Presented.
Electrical Safety.
Cutting an In-Line Dead-end Single Phase
Control of Hazardous Energy
Are Your Employees Qualified?
A 3 Insulator Changeout with Jib
C 4 Insulator Changeout With Hoists
Safety Meeting Topics Standby Generator Safety
Presented by Environmental Health and Safety
Protective Grounding Single Phase Tangent
Changes to Part 4 – Work Rules
Line Clearance Tree Trimming Operations
Click anywhere to get started…
Are Your Employees Qualified?
Lockout/tagout Refresher Training
A4 Insulator Changeout © 2018 Iowa Association of Electric Cooperatives.
Cutting in Bells Single Phase
Cutting in Bells Three Phase
C3 Insulator Changeout With Jib
A 3 Insulator Changeout With Hoists
Adding an A5 tap to an A1 © 2018 Iowa Association of Electric Cooperatives DISCLAIMER: This job hazard analysis (JHA) has been made available for informational.
A 3 Insulator Changeout with Jib
Line Down Single phase © 2018 Iowa Association of Electric Cooperatives.
A5 Insulator Change Transformer Pole
A1 Pole Changeout Energized
A4 Insulator Changeout © 2018 Iowa Association of Electric Cooperatives DISCLAIMER: This job hazard analysis (JHA) has been made available for informational.
Cutting an In-Line Dead-end Single Phase
Protective Grounding Single Phase Tangent
Adding an A5 tap to an A1 © 2018 Iowa Association of Electric Cooperatives.
C1 Insulator Changeout © 2018 Iowa Association of Electric Cooperatives.
LOCKOUT/TAGOUT By: Kory Hildebrand.
Presentation transcript:

Isolate isolated (A) Physically separated, electrically and mechanically, fromall sources of electrical energy. Such separationmay not eliminate the effects of electrical induction. (B) Not readily accessible to persons unless special means for access are used.

Generally Speaking You may consider a system, circuit, and/or apparatus isolated when it is removed from normal sources of potential Remember, the key word here is Normal source Explain that even though switches may be opened, jumpers may be lifted, and breakers may be open, none of these will prevent induced voltages from parallel or adjacent energized lines, equipment failure, and/or a lightning strike.

Isolate Defined Physically separated, electrically and mechanically, from all sources of electrical energy Such separation may not eliminate the effects of electrical induction! Explain that according to the IEEE isolated means: (A) Physically separated, electrically and mechanically, from all sources of electrical energy. Such separation may not eliminate the effects of electrical induction.

Isolate Defined Not readily accessible to persons unless special means for access are used Explain that according to the IEEE isolated means: Not readily accessible to persons unless special means for access are used.

Primary Voltage Rule Never work on more than one phase at a time Includes the neutral Therefore, if you are not working on a adjacent phase or conductor, it should be covered by approved insulating material Explain that according to the ETD Partnership’s I&I best practice a primary rule of line work is that a line worker never works on more than one phase at a time (neutral included). Therefore if you are not working on a adjacent phase or conductor, it should be covered by approved insulating material (line hose, rubber blankets, etc.). The extent of this covering is defined as Extended Reach. Extended reach is a minimum safe work distance determined by a phase-to-phase voltage range.

Determine Minimum Approach The employer must determine minimum approach distance Engineering analysis Customer requirements OSHA tables Explain that by no later than April 1, 2015, for voltages over 72.5 kilovolts, the employer shall determine the maximum anticipated per-unit transient overvoltage, phase-to-ground, through an engineering analysis or assume a maximum anticipated per-unit transient overvoltage, phase-to-ground, in accordance with Table V-8. When the employer uses portable protective gaps to control the maximum transient overvoltage, the value of the maximum anticipated per-unit transient overvoltage, phase-to-ground, must provide for five standard deviations between the statistical sparkover voltage of the gap and the statistical withstand voltage corresponding to the electrical component of the minimum approach distance. The employer shall make any engineering analysis conducted to determine maximum anticipated perunit transient overvoltage available upon request to employees and to the Assistant Secretary or designee for examination and copying.

Minimum Approach Distance MAD Line workers must maintain the minimum approach distance from exposed energized parts Ergonomic Component E Energized Part Explain that the ergonomic component of the minimum approach distance accounts for errors in maintaining the minimum approach distance (which might occur, for example, if an employee misjudges the length of a conductive object he or she is holding), and for errors in judging the minimum approach distance. The ergonomic component also accounts for inadvertent movements by the employee, such as slipping. In contrast, the working position selected to properly maintain the minimum approach distance must account for all of an employee's reasonably likely movements and still permit the employee to adhere to the applicable minimum approach distance. (See Figure 1.) Reasonably likely movements include an employee's adjustments to tools, equipment, and working positions and all movements needed to perform the work. For example, the employee should be able to perform all of the following actions without straying into the minimum approach distance: Adjust his or her hardhat, Maneuver a tool onto an energized part with a reasonable amount of overreaching or under reaching, Reach for and handle tools, material, and equipment passed to him or her, and adjust tools, and replace components on them, when necessary during the work procedure. The training of qualified employees required under § 1926.950, and the job planning and briefing required under § 1926.952, must address selection of a proper working position.

Ergonomic Component Employees should be able to perform all of the following actions without straying into the minimum approach distance: Adjust his or her hardhat Maneuver a tool onto an energized part with a reasonable amount of overreaching or under reaching Reach for and handle tools, material, and equipment passed to him or her Adjust tools, and replace components on them, when necessary during the work procedure Explain that OSHA requires that the employer shall ensure that no employee approaches or takes any conductive object closer to exposed energized parts than the employer's established minimum approach distance, unless: The employee is insulated from the energized part The energized part is insulated from the employee and from any other conductive object at a different potential, or The employee is insulated from any other exposed conductive object in accordance with the requirements for live-line bare-hand work

Conductive Objects Minimum Approach Distance starts at the end of a conductive object held in the hand Discuss that line cover must be installed in such a manner that all exposed energized parts are covered so that conductive objects held by the line worker cannot contact the energized part. Examples are: line jumpers, guy wires, cross arms, armor rods etc.

Review To protect workers from hazardous differences in electrical potential: Insulate yourself from the hazard by using: Cover up, Insulating Gloves & Sleeves, Live Line Tools, Insulated Booms Isolate yourself from the hazard or Isolate the hazard from you by: Removing from energized part from normal sources of potential via Open Switches, Remove Jumpers, Open Breakers, Maintain Minimum Approach Distance, Limited Access (i.e. Barricades)