Advanced Meter School August 18-20, 2015 INSTRUMENT TRANSFORMER SIZING 2015 David L. Johnson.

Slides:



Advertisements
Similar presentations
Faraday Generators/ Motors Induced Current Lenz’s Law/ Changing B
Advertisements

Chapter 4 Transformer Connections
Ohm’s Law.
CURRENT TRANSFORMERS AND VOLTAGE TRANSFORMERS
Chapter 12 Transformers. Chapter 12 Transformers.
 E4 Electrical Installation #1 Power Distribution.
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
TRANSFORMERS. TRANSFORMER PARAMETERS Turns Ratio (n) It is defined as the ratio of the number of turns in the secondary winding (N sec ) to the number.
Unit Transformer Unit transformer are step up transformer which is connected to generating house & step up voltage from 15kV voltage to 132 voltage level.
Unit 27 Three-Phase Circuits
Three Phase Power Three Phase Motors
Unit 29 Three-Phase Transformers. Objectives: Discuss the construction of three-phase transformers. Discuss the formation of a three-phase transformer.
Substations. Substations Chapter 4 Substations Major types of equipment found in most transmission and distribution substations with their purpose,
Transformer with open secondary.
Line and Phase Voltages for a Wye Circuit.
Unit 28 Single-Phase Transformers. Objectives: Discuss the different types of transformers. List transformer symbols and formulas. Discuss polarity markings.
Engineering Practice Electric Fitting Resistance Electrical resistance is the ratio of voltage drop across a resistor to current flow through the resistor.
Direct Current Electricity DC
Instrument Transformers
Connections of a CT and a PT to supply, load and relay.
Announcements For lectures 8 to 10 please be reading Chapter 3
POWER CIRCUIT & ELECTROMAGNETICS
1 Air Conditioning Three Phase Power. 2 Most common in commercial and industrial buildings Three hot legs, one ground, and one neutral L1, L2, L3, N,
EXAMPLE A pole mounted 100kVA distribution transformer has the following characteristics R 1 = 1.56  R 2 =  X 1 = 4.66  X 2 =  Volts Ratio.
Chapter 2 Transformers Edit by Chi-Shan Yu Electric Machinery.
Current flow versus Electron flow Conventional current flows this way. Electrons flow this way.
Transformer Current & Voltage Practice
Amperes, Volts and Ohms. We use different units to measure different things: We use different units to measure different things: Time – minutes Time –
Lecture 09Electro Mechanical System1 Chapter 11 Special Transformers.
Single-Phase Transformers Prepared By: Chadarana Jigna( ) Gandhi Disha ( ) Kanani Mital ( ) B.E SEM : 3 Subject:- Electrical.
Field Problems with Instrument Transformer Installations
REDA Production Systems
D.C. Machine & Transformer Topic: Instrument Transformer Electrical:-1 presented by: Jill Chauhan ( ) Chirag Agarawal ( )
1 :. Introduction These are special type of transformers used for the measurement of voltage, current, power and energy. As the name suggests, these transformers.
TITLE- BUCK BOOST TRANSFORMER BY- NEERAJ S ABHYANKAR SEMINAR GUIDE- H.O.D.Mrs.M.H.DHEND.
Part Three – Relay Input Sources
1. 2 Magnetization Current in a Real transformer Although the output of the transformer is open circuit, there will still be current flow in the primary.
Current Transformer Testing
ET 332b Ac Motors, Generators and Power Systems 1 Lesson 11_et332b.pptx.
Lesson 12: Parallel Transformers and Autotransformers ET 332b Ac Motors, Generators and Power Systems 1 Lesson 12_et332b.pptx.
Lesson 7: Power and Energy Measurement
Current Electricity.
E4 Electrical Installation
Sub Station.
CHAPTER 6 SPECIAL TRANSFORMERS Electrical Machines.
ECE 476 POWER SYSTEM ANALYSIS
Chapter # 25 Sub-Stations risemark.pbworks.com.
Electric Machine Transformers
RESISTANCE AND OHM’S LAW
Electricity - Current.
Transformer -Types & Applications
Special Transformer Current Transformer ( C.T. )
E4 Electrical Installation
TESTING AND COMMISSIONING OF ELECTRICAL EQUIPMENTS. TITLE : TESTING OF CURRENT TRANSFORMER AND VOLTAGE TRANSFORMER PREPARED BY : JOBIN ABRAHAM.
Associated Hazards and Safety Practices
Lesson 11: Transformer Name Plate Data and Connections
Electric Meter Identification
Ohm’s Law The relationship between voltage, current and resistance is known as Ohm’s Law: V = IR Voltage (V) = Current (I) x Resistance (R) Volts.
Transformer Impedance
EET 503 Power System Protection (Instrument transformer )
TRANSFORMERS.
EET 323 – Electrical System Design Lecture 14: Transformers
Chapter 33 Transformer: Three Phase. Chapter 33 Transformer: Three Phase.
Transformer Calculations: Word Problems
ELECTRIC POTENTIAL.
Grid system is accomplished by three-phase alternating currents.
Smitty’s Two Minute Drill General Knowledge
Calculations Review Drill
Presentation transcript:

Advanced Meter School August 18-20, 2015 INSTRUMENT TRANSFORMER SIZING 2015 David L. Johnson

What is an instrument transformer? A current transformer (CT) is used for measurement of electric currents. Current transformers, together with voltage transformers (VT) or potential transformers (PT), are known as instrument transformers. When current in a circuit is too high to directly apply to measuring instruments (meters), a current transformer produces a reduced current accurately proportional to the current in the circuit, which can be conveniently connected to measuring and recording instruments (meters). A current transformer also isolates the measuring instruments (meters) from what may be very high voltage in the monitored circuit. Current transformers are commonly used in metering and protective relays.

Why ? When ? How ?

Why ? High Currents: over 200 amps High Currents: over 200 amps High Voltage: over 240 volts High Voltage: over 240 volts

When ? Industrial Industrial Commercial Commercial Service greater than 200 Service greater than 200 amps amps

How ? Overhead Service Overhead Service Underground Service Underground Service Secondary Secondary Primary Primary

Window (doughnut) Window (doughnut) Styles

Spade

Primary C.T. Primary C.T.

P.T. or V.T. P.T. or V.T.288/2.4= 120 volts 2.4/1 P.T. 277/480 volt service 4-wire wye

P.T. or V.T. P.T. or V.T. 4/1 P.T. 480/4= 480/4= 120 volts 480 volts service 3-Wire Delta

C.T. Ratio 200/5 = 40/1 400/5 = 80/1 600/5 = 120/1 800/5 = 160/1 1000/5 = 200/1

2.4/1 277/2.4=116 volts2.4/1 277/2.4=116 volts 4/1 480/4=120 volts4/1 480/4=120 volts Potential Transformer (P.T.) 60/1 7200/60=120 volts60/1 7200/60=120 volts

Understanding Ratios The relation between two similar magnitudes with respect to the number of times the first contains the second: the ratio of 200 to 5, written 200:5 or 200/5. Example: 200/5: For every 200 amps that flow through the primary winding (window), the meter will receive 5 amps. From the secondary side of the C.T.

Name Plates 200 :5A RF = 30C AMB RF = 55C AMB

R.F. Rating factor : The amount by which the primary load current may be increased over its name plate rating without exceeding the allowable temperature rise. Temperatures are measured in C (celsius).

Rating Factors Examples: 200/5 with a R.F. 2.0 = 400 max amps200/5 with a R.F. 2.0 = 400 max amps 200/5 with a R.F. 3.0 = 600 max amps200/5 with a R.F. 3.0 = 600 max amps 200/5 with a R.F. 4.0 = 800 max amps200/5 with a R.F. 4.0 = 800 max amps 400/5 with a R.F. 2.0 = 800 max amps400/5 with a R.F. 2.0 = 800 max amps 400/5 with a R.F. 3.0 = 1200 max amps400/5 with a R.F. 3.0 = 1200 max amps 400/5 with a R.F. 4.0 = 1600 max amps400/5 with a R.F. 4.0 = 1600 max amps Etc…Etc…

200/5 with R.F :5A RF = 30C AMB RF = 55C AMB

1200/5 with R.F RF

Q: Is it important to consider R.F.s? A: Yes. Your billing depends on accuracy. accuracy.

KVA Converting KVA to amps KVA x 1000 / line to line voltage / sq rt of 3 (1.732) KVA x 1000 / line to line voltage / sq rt of 3 (1.732) Examples: 500 x 1000 / 480 / = 601 amps500 x 1000 / 480 / = 601 amps 500 x 1000 / 208 / = 1387 amps500 x 1000 / 208 / = 1387 amps 1500 x 1000 / 480 / = 1804 amps1500 x 1000 / 480 / = 1804 amps 1500 x 1000 / 208 / = 4163 amps1500 x 1000 / 208 / = 4163 amps

Transformer Rated Meters Meter Form # 3s: Class 20 Meter 3s : Single Phase Service. Service Type: Secondary 120 volt 2-Wire.Service Type: Secondary 120 volt 2-Wire. Service Type: Single-Phase Primary C.T. and P.T.Service Type: Single-Phase Primary C.T. and P.T.

Transformer Rated Meters Meter Form # 4s: Class 20 Meter 4s: Single Phase Service. Service Type: 120/240 3-Wire with 2 C.T.Service Type: 120/240 3-Wire with 2 C.T.

Transformer Rated Meters Meter Form # 5s: Class 20 Meter 5s : Three Phase Service. Service Type: 120/240 4-Wire Hi LegService Type: 120/240 4-Wire Hi Leg Service Type: 240 volt 3-Wire.Service Type: 240 volt 3-Wire. Service Type: 480 volt 3-Wire.Service Type: 480 volt 3-Wire. *Meter also known as Form 45s

Transformer Rated Meters Meter Form # 9s: Class 20 Meter 9s : Three Phase Service. Service Type: 120/208 volt 4-Wire WyeService Type: 120/208 volt 4-Wire Wye Service Type: 277/480 volt 4-Wire Wye.Service Type: 277/480 volt 4-Wire Wye. Service Type: Primary C.T. and P.T.Service Type: Primary C.T. and P.T.

How to Determine the Correct Size C.T. Transformer Rated Meters are rated for 20 amps Transformer Size: KVA Power Formula: KVA x 1000 / line to line voltage / Rating Factor: 2, 3, 4 Meter: 20 amps max C.T. Ratio: 200, 400, 600, etc… Wire Size: 2/0, 4/0, 250, 350, etc…

Questions / Answers