Aeon Gold – System Overview *TCP/IP *SNMP Aeon Gold Display Unit *Advanced setup and *monitoring through *WinPower *SW Download PC w /WinPower Aeon 4000.

Slides:



Advertisements
Similar presentations
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
MODULAR SMPS POWER PLANT
12-Port IP Power Manager IPM  Product Overview  Product Features  Applications  Comparison Presentation Outline 2 / 15.
NT series introduction UPS training June 2006 Markus Schwab.
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
IPS Rev 1.0 Ken Lutz University of California, Berkeley
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
MSD and MSD Automatic Battery Test Systems
1 Modular DC/DC Converter. 2 PSC W Standard 19“ rack 4U – 6 prewired slots (single DC input/output connection for each unit)
Freedom Combi Inverter
LP Series 11/31T - Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
PPS 3.3 C Portable Power Source Page 1 January 2011.
POWER PLANT USED IN TELECOM
MarsⅡ On-Line UPS Series
Single Loop Analogue addressable fire control Panel
Charge Controllers Regulating Battery Charging.
LP Series U Technical presentation ISO 9001 UL CUL FCC Class A CE.
Chapter 11 Bruce Gaffield Randy Binns Scott Thrush Kristi Partney Edited by Richard Goldman.
Hardware Training Product: ITMS2.
WEBPOWER Stand-alone & Embedded. POWERFUL TECHNOLOGY Scope of training  1. General Network information  2. WebPower Configuration  3. WebPower Functionality.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
LEADING THE PACK.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
FLATPACK Rev.5 September 2002 Updated versions may be available.
Technical Panel Session. Sunday January 11, DC System Failure Modes IEEE PES SBC Winter Meeting. January 11 – 15, New Orleans, LA Part 3.
Exit LEADING THE PACK Eltek 2 UNLEASHING THE LEADER OF THE PACK.
Arduino based Automatic Temperature Controlled Fan Speed Regulator.
BUILDING LOAD NORMAL OPERATION 1. ATS are in normal position connected to utility source 2. All generator set paralleling circuit breaker open.
DIGITAL MULTIMETER DMG
Poseidon 4002 Rack monitoring.
NEW RMC Rack Multi Control.
Avaya VA Line-interactive UPS
IP-based 8-port Switched Power Manager
Automatic Battery Test System Tim Pennock
Maintain, Manage And Monitor Outdoor Systems Remotely
Battery Monitor Data Manager Demonstration
Avaya Online UPS 6000 VA.
System Network Structure
Technology that lets you Trust your batteries!
PTS 3.3 C Portable Test System.
Avaya Online UPS 6000 VA.
LDA Large Display for Analog Inputs
A transformer is a complex protective object
FEEDER PROTECTION UNIT
MPU-16A / FPU-16 TEST UNIT TUTORIAL
PowerValue 11 RT Sales Presentation
Module 1: System Overview
PowerValue 11/31 T Sales Presentation
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
Module 1 – Power Supply AMC APS-PBC-60
IRRInet-M IRRInet-ACE Product Introduction
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Regulating Battery Charging
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
ACOE347 – Data Acquisition and Automation Systems
Switching & Controlling LoB
Integrated gateway-server
Series 5300 Lithium Cell Formation System
PowerLogic™ offer for the basic metering market
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
Field installable, upgradeable and scaleable
48V Power Shelf Operation
Backup Power supply for Electrical substations Overview 01/2012
Power monitoring software
Nellcor™ Bedside SpO2 Patient Monitoring System, PM100N - Home use
Presentation transcript:

Aeon Gold – System Overview *TCP/IP *SNMP Aeon Gold Display Unit *Advanced setup and *monitoring through *WinPower *SW Download PC w /WinPower Aeon 4000 w /Aeon Gold & SMPS4000 Aeon Gold Control Unit *CAN Bus

Aeon Gold in Aeon 4000 Aeon Gold Display Unit Rear view Battery fuse Load fuse 2 shelves, each including 6 rectifiers 2 rows with MCB’s for internal distribution Aeon Gold Control Unit AC MCB’s AC distribution 2PR – Power Rack System Hinged door

Aeon Gold – HW Specification User friendly interface with keypad and graphical display System parameters can be seen and altered Graphical Display Green LED - Power Keypad Red LED - Alarm 3 Keys for menu scroll 10 Numerical keys 1 key for scroll back

Aeon Gold – HW Specification Cont. SW appload 10 Digital outputs (Relays) WinPower Modem, TCP/IP, SNMP 7 Digital inputs Upper position- control unit alarm Enabling sw appload Red LED, when in service mode

Aeon Gold – HW Specification Cont. 5 Current inputs 5 Voltage inputs 2 Temperature inputs System connections: AC & DC input LVLD & LVBD Battery & Load fuse alarm Keypad connector 2 CAN bus connectors DC Fuse Green LED, Heartbeat Reset button Calibration output, 60mV

Aeon Gold – Main Menus Aeon Gold is divided into three main menus: User Setup: Information accessible for everyone, Read only. Service Setup: Password protected, setup and changing parameters. Factory Setup: Password protected, installation setup, usually done at factory.

Aeon Gold – Menu Structure

Aeon Gold - Functionality Features: Output voltage monitoring and control Load and battery current monitoring and control Individual rectifier control Temperature compensated charging Boost charging Battery testing Fuse monitoring

Aeon Gold – Functionality Cont. Features: Alarm log LVD disconnect for load and/or battery Advanced alarm/event setup Advanced configuration of relay outputs Communication through IP Symmetry monitoring Capacity and backup time calculation

Aeon Gold – WinPower 4000 A Windows NT, Windows 98 software package for Aeon Gold. All configuration and change of parameters can be done here. Communicating with Aeon Gold through PCOMM protocol. Configuration of relay outputs and trend data is not available from graphical display. Winpower must be used.

Aeon 4000 – Autoboost Mains OK Discharge > Threshold = Autoboost Discharge < Threshold = Float 54,5V Mains OK, FloatMains OK, AutoboostMains failure Battery Temp. limit reached Recharge (% of discharge) = Boost factor [ %] 56,0V (Dynamic Current Limiting & Equalize Thermal Stability)

Aeon 4000 – Intelligent Re-charge Float current Battery current limit [A] = 0.3*C 10 Mains OKMains OK, RechargeMains failureMains OK Load current

Aeon 4000 – Temperature Comp. Min Comp, voltMax Comp, Volt Slope Charge voltage is temp. dependant Prevents gassing at high temperature Obtain max. charging at low temperature and maintain capacity

Aeon 4000 – Energy Management When a fully equipped shelf powers a 200A load, we have 2 scenarios. Aeon 4000 can handle both. Current sharing between 6 rectifiers, which means low efficiency and high utility cost Current sharing between 3 rectifiers, with decreased AC input current and high efficiency 1 shelf including 6 rectifiers, power output equal 450 A 6 rectifiers Irect.=200Amp/6 Irect.=34 Amps Low Efficiency 3 rectifiers Irect.=200Amp/3 Irect.=66 Amps High Efficiency