35T Phase 1 and the PrMs AHahn PAB Meeting, 4/9/14 1.

Slides:



Advertisements
Similar presentations
Stratagem EH4 Field Evaluation of Data Quality.
Advertisements

AV Controls in the Conference Rooms Trying to Navigate the Changes.
Session 4: Termination and Splices. 2 FO Connectors Specifications Specifications Loss Repeatability Environment (temp, humidity, vibration, etc.) Reliability.
A-dec 300 Dual Mount on 500 Installation. Agenda ► General Information ► Recommended tools ► Installation ► Follow through install guide ► Hands-on install.
How to carry out experiments using MPMS March 2012 Takeshi NAKAGAWA.
Put a drop of oil inside the wire holder caps – stops rust.
KOSMAK MACHINE ELECTROFOK (MICRO FIBER OPTIC CABLE BLOWING MACHINE WITH ELECTRIC)
TPC Proposal for the 35 Ton Liquid Argon Test Abstract We propose to equip the 35 ton cryostat with one APA and two CPA’s, and all the necessary equipment.
Analogue and Digital Signals We seem to live in an analogue world – things can be louder or quieter, hotter or colder, longer or shorter, on a “sliding.
We begin by subtracting noise (run flash lamp without HV) from signal (run flash lamp with HV) In the above for the cathode, we subtract the brown noise.
LBNE 35 ton prototype Phase 1 summary Terry Tope Fermi National Accelerator Laboratory All Experimenters’ Meeting – Fermilab – May 19, 2014.
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
Materials Qualification for long drift Liquid Argon TPC Effect of water on electron drift lifetime Plans Material Tests, purging and H20 studies, Purity.
1 Comparison of MIRAC-4 array with Cornell test array, both warm ver 3 Bill Hoffmann November 10, 2009 Test configuration Array: MIRAC-4 array or Cornell.
Part A: Controlling Oscillation Frequency with Capacitors and Resistors Part B: Diodes and Light Experiment Timer.
Digital Hadron Calorimeter Cosmic Ray Test Stand.
Pulse Width Modulation (PWM) LED Dimmer Circuit
AccuMax Multi-Point Injection Mechanics
The physical network Unit objective: Identify network cables and connectors, and use networking tools.
Electricity, Electronics And Ham Radio “Kopertroniks” By Nick Guydosh 4/12/07.
Some Work on Liquid Argon Purity at Fermilab f 6/9/2011 S. Pordes TIPP 1.
Gasoline fuel supply systems Function: store, transport, Pressurize and filter gasoline going to carburetor or fuel injection system.
ATLAS Liquid Argon Calorimeter Monitoring & Data Quality Jessica Levêque Centre de Physique des Particules de Marseille ATLAS Liquid Argon Calorimeter.
Liquid Argon Time Projection Chamber: Purity and Purity Monitoring DAVID GERSTLE – LArTPC – YALE UNIVERSITY/FNAL 31 May 2006 – FNAL Users’ Meeting Materials.
Materials Qualification for long drift Liquid Argon TPC Effect of water on electron drift lifetime Plans S. Pordes Argon Purity1Integrated R & D Plan Review.
Doug, here are some slides. FGT Electrical Integration ethernet trig/clk DDL fiber Wiener MPOD controller ISEG 8 ch HV -4 2 mA ARC module (APV Readout.
FUEL INJECTOR DIAGNOSIS
Test beam setup: status report 31/03/2009 M. Alfonsi (CERN)
Materials Qualification for long drift Liquid Argon TPC Effect of water on electron drift lifetime Plans Material Tests, purging and H20 studies, Purity.
High Gain Mystery of WS(1-5) Solved (Hopefully…) C.Woody HBD Meeting April 13, 2010.
Long Bo for LAPD Hans Jostlein10/20/2011 December 15, 2015 Long Bo for LAPD 1.
Dance Pad Project By: David Dorsten. Understand  Electric Engineering Project = Dance Pad and Light Bulb Station  This activity will demonstrate the.
ABL-14d Able Elective Engines Instructors: George Crowl.
S. Pordes - FNAL May 13th Purity Monitor - Description and Experience at Fermilab Production of Clean Argon - Description of Filtering System and.
Luke or MTS Q anode. MOBY DICK  Purpose of Moby Dick:  Can we even get to ~10 ppb O 2 and H 2 O?  What other things in Moby will cause loss of LAr.
1/26/2009 S. Pordes LAr R & D Briefing 1 Liquid Argon presents prospect of continuously live Imaging Calorimeter C. Rubbia.
Ions in LAPD Can we Observe Them in Long Bo ? 3/6/2016 Ions in LAPD Sarah Lockwitz and Hans Jostlein, Fermilab 1 Sarah Lockwitz and Hans Jostlein Fermilab.
Materials Qualification for long drift Liquid Argon TPC Effect of water on electron drift lifetime Plans Material Tests, purging and H20 studies, Purity.
Recent Gain Changes C.Woody HBD Meeting March 23, 2010.
Methane Update and Run Plan Ben Jones. Configuration 8 inch PMT with TPB plate - 8” from alpha source - Now includes magnetic shield - 2 inch PMT without.
Liquid Argon Purity Monitor Testing Bonnie Weiberg TRAC Program Summer, 2015 ICARUS clone made at FNAL (S. Pordes - FNAL May 13th 2006)
PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND Doug Roberts U of Maryland, College Park.
Cryogenic Test Stand Facilities at PAB: Stephen Pordes Neutrino R&D Workshop January 20 –
30GHz system improvements Jan Kovermann RF meeting
Single Phase ProtoDUNE TPC CERN The SP TPC Team Jan. 13, 2016.
FUEL INJECTOR DIAGNOSIS
Installation of the T600 at Fermilab
L 29 Light and Optics - 1 Measurements of the speed of light: c = 3 × 108 m/s = 186,000 miles/s light propagating through matter – transparent vs. opaque.
DVOM Not-So Basics.
The High Voltage problem
Instrumentation Used in LAPD and 35T Runs (Dune DocDB 1759)
Monitoring system commissioning
Status of measurements with the Napoli TPC
David Montanari / Johan Bremer Jun 11, 2015 Rev. 1
2011/ 07/06 Jacqueline Yan IPBSM
Setup for Cosmic Ray Test of VPA panel, using MiniDAQ
Warm structure requirements :
Compound Microscope Review
Things to be Aware of the Intake Air Temperature Sensor
ELECTRICKERY You need to change the first page to have your name on it
Electrical Safety in the Home
FIGURE 21-1 The digital multimeter should be set to read DC volts, with the red lead connected to the positive (+) battery terminal and the black meter.
ELECTRICKERY Presented by
ELECTRICKERY Presented by
AM-7026 Down Converter-Receiver
Teacher training resource: Robotic Assembly
SNAP CIRCUITS INSTRUCTIONS
MEG II実験 液体キセノン検出器の建設状況
Automotive Technology Principles, Diagnosis, and Service
Presentation transcript:

35T Phase 1 and the PrMs AHahn PAB Meeting, 4/9/14 1

Outline PrM setup in 35T Phase1 run PrM timeline PrM raw results Issues found Summary Success stories Future 2

3 PrM0 is the inline PrM in its Normal location just after the Filters

External Setup PrMs (1->4) – Single Flashlamp Located in WJ “Oscar-Style” Faraday cage ~25 feet optical fiber from FL to PrM Flange – 3 fibers/PrM – NIM Bins with W-J electronics &HV ~25 feet of cable away from PrM Flange – Rack included Multiplexor, WindowsXP PC with Alazar 2ch digitizer PrM had its own FL in same location as in LAPD run. – NIM bin with W-J electronics & HV in same LAPD location – ~200 feet cable runs to Multiplexor in 35 T PrM Rack DAQ was LabVIEW based – Included Spooler Application with token control – Raw Data files of each flash stored locally, summary data to IFIX (like LAPD) 4

Coarse Timeline Aug-Oct 2013: PrMs refurbished and tested at PAB – Included new cathodes and internal re-fibering. – Walter J. worked on tightening up the PrM to fix HV breakdown problems due to loose lugs on PEEK spacers rotating into grounded Faraday cage Nov 1, 4, 11, PrMs(0-4) inserted into 35T Cryostat – Walt checked out the installation and everything appeared fine. – Terry T. put dry air purge on system. Nov 19—Ar Purge started – GAr signals on PrM0, PrM (1-4) not hooked up Nov 27—PrM(1-4) fibered up and cables to Electronics Dec 2 – PrM (1-4) operational in GAr. Dec 16– See first LAr Cathode and Anode Signals on PrM0 Dec 17– Cryostat Cooldown starts Dec 18– Cryostat filling starts, see lower PrM cathodes covered by LAr (cathode signal drops) – First fill leaves upper short PrM4 uncovered, so still operating in GAr. Dec 20—LAr Pump start, now filtering. – Initially things look fine, but then start seeing noise on PrM 1&3, mainly anode looking very bad. Dec 22—See anode signal on PrM2 (lifetime ~700us) Jan 6– Top off 35T cryostat with LAr, PrM 4 is now covered—see PrM 4 anode signal Feb7—turn off pump, end filtering of LAr. Feb 13—Begin pumping LAr out to tanker to send to MicroBoone—PrM 4 now in Gar Feb 21– Fill second tanker for MicroBoone Mar 3—Begin GN2 bubbling through remaining LAr to warm up cryostat. Mar 10---See Cathode signals on both lower PrMs, 1&2 5

Purity during run (not cleaned up) 6 “Low State” Top off Tank PrM4 covered Switch to Pump B

Issues Found PrM 1& 3 anodes signals very susceptible to LAr Pump noise (microphonics) (slide 8) – Took (me) longer to realize that PrM1&3 didn’t have anode pulse signals at all during the LAr period(slide 9, 10) PrM 2 had two states for the anode (slide 11) – Large anode signal<---- believe this was “true value) – Small anode signal<---- believe this was due to some fault in drift field “optics” – Occasionally intermediate size anode In this case, looking at individual flashes showed a combination of large and small anode signals 7

Anode Noise (12/20) 8 Pump turned On Black Trace is Anode Signal-Cathode Signal Red is Cathode Signal, Blue is Anode Signal (Note there is no anode peak on either plot, lifetime is still very short) 10AM5PM

Disappearance of PrM1&3 Anode signals (after the fact discovery) 9 Short PrMs Long PrMs

Reappearance of PrM1&3 Anode Signals during the warmup of 35T Cryostat 10 Anode PH (Volts)

PrM2 Anode PH Bi-State (cathodes relatively constant) 11 Same run Diff. runs

Summary of Issues PrMs mechanically seem very susceptible to vibrations, perhaps even losing electrical contacts on field systems – PrM1&3 suffered “catastrophic” issues – PrM2 was bi-stable Even low state seem to follow the purity though – PrM4 worked best, but even then had periods where it was very susceptible to microphonic noise. On a different scale, need to improve the actual intensity of the cathode signal – Low cathode signals (<10mV) makes system even more sensitive to noise issues – Improve Flashlamp/Fiber Optic efficiency. Reduce length of FO Understand if how much connectors reduce yield Are we breaking fibers during insertion? (see Mark R. pictures of autopsies in PAB log. Had some problems with apparent HV breakdowns—pulses with very fast risetimes. – Some may have been HV breakdowns, but maybe poor contacts in field cages ?? 12

Success Stories Walter’s Faraday cage really worked well. PrM0 had many fewer problems than the others. 13 Mean =0.99

Future Look into “ruggedizing” the PrM – Not sure I completely understand what is actually happening, but it appears the PrM loosens up as it cools down (see slides 9&10) Makes it sensitive to microphonics (particularly the anode) – Not clear what was source of pump acoustical noise—vibration or flow (see next slide) Even possible to lose signals---only anode in this run. Get frontend electronics closer to PrM flange (~20+ feet this time). Improve the Fiberoptic “bundling” at the flashlamp. – Everytime I touched the flashlamp assembly, I seem to make changes in light pickup – Need to hold fiber bundle together better. – Reduce the length of fiber—get Faraday cage closer to flanges. I note that changing the flashlamps/bulbs improved the cathode peakheight by ~3-4 x over previous value. – Also note putting in new bulb made things worse at one point. 14

Cryostat setup (T.Tope) 15 Pump Intake manifold PrM 1&3 PrM4 (short) PrM2 (long)