Wednesday Case of the Day History: 32-year-old female (approximately standard-sized female) undergoes CT scan of abdomen and pelvis after motor vehicle.

Slides:



Advertisements
Similar presentations
CT Scanning: Dosimetry and Artefacts
Advertisements

CT Organ Dose - Part 1 Estimating organ dose for patients Michael F. McNitt-Gray, Ph.D., DABR David Geffen School of Medicine at UCLA.
State of Michigan Computed Tomography Regulations
Key CT Parameters - What Are They Called and What Do They Mean?
The unintentional irradiation of a live human fetus: assessing the likelihood of a radiation-induced abortion Eduardo Galiano Laurentian University Marcelo.
Seeram Chapter 13: Single Slice Spiral - Helical CT
RAD309 Patient Dose.
NC HPS Meeting 10/18-19/2001 Boone, NC Recent Advances in CT Technology and Issues of CT Dosimetry T. Yoshizumi 1,2, M. Sarder 1, R. Reiman 1,2, E. Paulson.
1 NEXT 2000: Survey of Computed Tomography (CT) Practice, Workload, Dose Stanley H. Stern, Ph. D. FDA/CDRH Office of Health and Industry Programs Division.
5 th September 2005 Paul Collins Computed Tomography Dosimetry Assessment of Effective Dose in Computed Tomography using an Anthropomorphic Phantom Paul.
1 Development of an FDA CT Organ Dose Handbook Thalia T. Mills, Ph. D. FDA Commissioner’s Fellowship project with Dr. Stanley.
American Association of Physicists in Medicine AAPM Working Group on Standardization of CT Nomenclature and Protocols.
An algorithm for metal streaking artifact reduction in cone beam CT M. Bazalova 1,2, G. Landry 1, L. Beaulieu 3, F. Verhaegen 1,4 1-McGill University,
tomos = slice, graphein = to write
Conventional and Computed Tomography
COMPUTED TOMOGRAPHY I – RAD 365 CT - Scan
Dose Survey in Computed Tomography DS /CM Kampala IAEA/RCA Kampala.
International Atomic Energy Agency L 4 PROTECTION ISSUES IN CLINICAL METHODOLOGY.
Radiation Protection of Patients Unit
Pratik Mehta, B.A. 1 ; Kate MacGregor, M.P.H. 2 ; Robert Gould, D.Sc. 2 ; Diana Miglioretti, Ph.D. 3 ; J. Anthony Seibert, Ph.D. 4 ; Rebecca Smith-Bindman,
CT physics and instrumentation
Computed Tomography Q & A
S Demehri 1, M.K Kalra 2, M.L Steigner 1, F.J Rybicki 1, M.J. Lang, 3, S.G Silverman 1. 1.Department of Radiology, Brigham & Women's Hospital, Harvard.
Fig. 3 shows how a dose distribution that is initially relatively sharp becomes blurred with time, until after 16 hours, virtually no useful information.
IAEA International Atomic Energy Agency Optimization of Protection in Computed Tomography (CT)-What can radiographers do? IAEA Regional Training Course.
QIBA CT Volumetrics - Cross-Platform Study (Group 1C) March 18, 2009 Interclinic Comparison of CT Volumetry Quantitative Imaging Biomarker Alliance.
How we set a DRL An example using CT David Sutton / Colin Martin Kampala IAEA/RCA Kampala.
1 Radiation Dosimetry in X-Ray Computed Tomography (CT): Standardization and Regulation Stanley H. Stern, Ph.D. Center for Devices and Radiological Health.
Designing for Radiation Protection. Design Standards for Radiation Protection – Leakage Radiation.
CS TC 22 CT Basics CT Principle Preprocessing. 2 CT Basics CT principle preprocessing CS TC 22 Blockdiagram image processor.
MEASUREMENTS OF RADIATION DOSES IN MULTISLICES COMPUTED TOMOGRAPHY EXAMINATIONS A. ELMAHDI*, A. SULIEMAN *Presenting author 1 Sudan Atomic Energy Commission,
Part No...., Module No....Lesson No
Somvilai Mayurasakorn, MD. Division of Therapeutic Radiology and Oncology, Faculty of Medicine, Chiang Mai University Somvilai Mayurasakorn, MD. Division.
Part No...., Module No....Lesson No
Quality Assurance.
What are the dose quantities in CT ? IAEA/RCA Kampala Kampala.
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
Monday Case of the Day History: Multiple examinations from a CT scanner using a standard helical scan protocol show diffuse hypointense regions of artifact.
History: A 61-year-old man with suspected thoracic aneurysm underwent ECG-gated chest CT angiogram. He was instructed to hold his breath during the exam.
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 12.1 : Shielding and X-ray room design Practical.
Sunday Case of the Day How does the presence of the object impact patient dose? A. Increases by 20% - 50% B. Increases by 3% - 5% C. No Change D. Decreases.
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
Single Slice Spiral - Helical CT
Tomography for Intraoperative Evaluation of Breast Tumor Margins:
-42 Impact of signal non-repeatability on spectral CT images
An exercise in how to assess the CTDIw , DLP and effective dose
CT Multi-Slice CT.
Materials and Methods Continued: Materials and Methods:
Impact of Obesity on Medical Imaging and Image-Guided Intervention
Patient exposure trends and problems in implementing ALARA
Role of Adaptive Statistical Iterative Reconstruction (ASIR) in lowering radiation dose for pediatric head CT Electronic Poster-eP 140 Azadeh Tabari, MD.
How we set a DRL An example using CT
Sunday Case of the Day Physics
Optimisation of Patient Protection for Radiography
Figure 1. (a) A set-up used for the measurements showing the head phantom and the ion chamber located in the central hole. The cylindrical phantom has.
Sample General Electric CT Dose Report from a CT of the chest, abdomen, and pelvis. The dose report contains information about the patient (deleted), type.
CT dose optimization software synergy – A clinical perspective
David Sutton or Colin Martin But Borrowed from Jerry Williams
Computed Tomography (CT) Dose Optimization
Physics Testing for ACRIN 6678 Protocol version 3.0 QIBA Group 1C
Exhibit Number: C19 Evaluation and Reduction of Head Computed Tomography Dose Because of full frame graphic use title slide sparingly because too many.
4D eXtended CArdiac-Torso (XCAT) Phantoms
Strategies for Reducing Radiation Exposure From Multidetector Computed Tomography in the Acute Care Setting  Aaron Sodickson, MD, PhD  Canadian Association.
Implementation of Object Spot Avoidance in Proton Pencil Beam Treatment on Whole Breast with Implant Metal Injector Peng Wang, PhD, DABR, Karla Leach,
Wednesday Case of the Day
Wednesday Case of the Day
Wednesday Case of the Day
David J. Brenner, Maria A. Georgsson  Gastroenterology 
Estimation of the effects of a lead vest on dose reduction for NPP workers using Monte Carlo calculations KIM JEONG-IN.
Presentation transcript:

Wednesday Case of the Day History: 32-year-old female (approximately standard-sized female) undergoes CT scan of abdomen and pelvis after motor vehicle accident. Later she discovers she was 7 weeks pregnant at time of scan. CT scan info:  GE LightSpeed 16 scanner.  120 kVp; fixed tube current, 400 mA; 0.5-sec rotation time; pitch, ; 16 x 1.25-mm collimation; 5-mm reconstructed slice thickness; standard reconstruction filter.  CTDI 100 (mGy/100 mAs) in 16-cm-diameter phantom: center = 16.0; peripheral =  Scan ranged from top of liver through to pubic symphysis. Estimate the radiation dose received by the fetus: a) 0.5–1 mGy. b) 10–15 mGy. c) 15–30 mGy. d) 30–50 mGy. e) 100–150 mGy. Authors: Michael F. McNitt-Gray, PhD, 1 Erin Angel, MS, 1 Mitchell M. Goodsitt, PhD, 2 Clinton V. Wellnitz, MD 3 1 Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, CA. 2 Department of Radiology, University of Michigan, Ann Arbor. 3 Mayo Clinic, Scottsdale, AZ. Physics Figure 1. Axial and sagittal views of gestational sac and uterus from patient who is 7 weeks pregnant at time of CT. Uterus Gestational Sac

Correct Answer (c) 15–30 mGy. Next several slides will go through three different methods of estimating radiation dose to fetus for this case: 1. Felmlee, Gray, et al method [AJR 1990 Jan;154(1):185–90] 2. Using ImPACT dose spreadsheet method ( 3. Monte Carlo simulation method with pregnant patient model (E. Angel, et al, RSNA 2006) Final slides will discuss implications of this level of radiation dose on fetus and recommendations.

Most often this calculation is requested in the context of a woman who didn’t know she was pregnant when she underwent a CT scan; sometimes this is requested ahead of time when the CT is scheduled for a woman who is known to be pregnant. Fetal Radiation Dose: Clinical Context

In the scenario presented, the following details were provided: 1.GE LightSpeed 16 (16–detector row) CT scanner kVp mA second rotation time. 5.Helical scan with pitch = x 1.25-mm collimation (20-mm nominal beam width). 7.CTDI 100 in 16-cm-diameter phantom of 16.0 mGy/100 mAs at center and 17.2 mGy/100 mAs at a peripheral (12:00) position under the above conditions. 8.Because scan ranged from top of liver through to pubic symphysis, the fetus was definitely in the x-ray beam. 9.The woman was standard female size—approximately 58 kg; 160 cm (128 lb; 5’3”). 10. The gestational age at the time of scan was later determined to be approximately 7 weeks. 11. No mention of additional risk factors to mother or fetus. Fetal Radiation Dose: Scan Protocol and Information

This paper [AJR 1990 Jan;154(1):185–90] first describes the normalized fetal- dose ratio (NFDR): –Defined as the measured fetal-dose contribution from a single CT scan divided by the CTDI measured (16-cm-diameter phantom) with the same scanning parameters. –Determined at various distances from the fetus. Felmlee, Gray, et al Method

Then the paper describes an integrated normalized fetal-dose ratio (INFDR): –Defined as the sum of individual NFDR(d) located from 0 cm to an offset distance, assuming 1-cm scans at 1-cm incrementation. –Determined at various distances from the fetus. Felmlee, Gray, et al Method

For example: At z = 0 cm offset (ie, directly over fetus), –INFDR(0) = At z = 10 cm offset (say, 10 cm inferior), –INFDR(10) = At z = 40 cm offset (say, 40 cm superior), –INFDR(40) = Felmlee, Gray, et al Method Z-axis location of fetus Scan ends 10 cm inferior to location of fetus. Scan begins 40 cm superior to location of fetus.

Fetal dose (mGy) = CTDI * INFDR E where: CTDI = center value from 16-cm phantom. INFDR E = INFDR 0 + INFDR Inf + INFDR Sup. –INFDR 0 = NFDR (from Table 3 of Felmlee) at 0 offset. –INFDR Inf = INFDR for scan locations inferior to fetal location. –INFDR Sup = INFDR for scan locations superior to fetal location. –INFDR Sup or Inf = (T/I) [INFDR(M) – INFDR(N–1)] –T = nominal beam width (in mm). –I = table increment per rotation (also in mm). –INFDR(M) = INFDR at the maximum offset distance M (cm) from fetal location. –INFDR(N–1) = INFDR at the minimum offset distance N (cm) minus 1 cm from the fetal location. Felmlee, Gray, et al Method

Under the conditions specified: 1. CTDI at center position of 16-cm phantom is 32 mGy. – CTDI at center position of 16-cm phantom was 16.0 mGy/100 mAs. – 200 mAs. 2. Superior location is approximately 40 cm superior to fetus. 3. Inferior location is approximately 10 cm inferior to fetus. 4. Pitch = = T/I, T = 20 mm, so I = mm. Therefore, INFDR E = INFDR 0 + INFDR Inf + INFDR Sup = (20/19.75)*(0.453 − 0.255) + (20/19.75)*(0.481 − 0.255) = = Fetal Dose = CTDI * INFDR E = 32 mGy * = 21.9 mGy Felmlee, Gray, et al Method

ImPACT Spreadsheet Method  Results are based on Monte Carlo simulations performed by National Radiological Protection Board (NRPB) as described in NRPB report 250. –(Jones DG, Shrimpton PC. Survey of CT practice in the UK: Part 3. Normalized organ doses calculated using Monte Carlo techniques. National Radiological Protection Board, NRPB- R250, 1991).  Original work done in  Modern scanners are “matched” to original scanners based on CTDI values measured in air and in phantom.  Helical scans modeled using pitch values: –(table travel per rotation)/(total nominal beam collimation).  MIRD patient model: –Hermaphrodite standard man representation. –Geometrically shaped organs, including uterus.

ImPACT Spreadsheet Method To obtain an estimate of fetal dose: 1. Choose scanner manufacturer and model. oMatched to a scanner make and model from original simulations. 2. Choose scanner parameters. okVp, body region (which selects the bowtie filter), mAs, beam collimation, pitch. oChoose start/end location of scan on patient model. 3. Provides an estimate of dose to all ICRP 60 organs, including uterus. 4. For early gestational age, estimate to uterus is approximately equal to fetal dose. See for more details on this method.

ImPACT Spreadsheet Method Uterus End location Start location

ImPACT Spreadsheet Method Uterus Dose in mGy

Monte Carlo Simulation Method (Angel et al, RSNA 2006)  Monte Carlo simulations based on: –Detailed description of scanner. –Detailed description of pregnant patient. –Simulate arbitrary scan protocol.

Monte Carlo Simulation Method (Angel et al, RSNA 2006) Monte Carlo model: –MCNPX software from Los Alamos National Lab. –Uses a detailed voxelized model of pregnant patient (next slide). –Description of scanner geometry (fan angle, SID, etc). –Simulates photon transport from modified x-ray source through patient model. Modified CT x-ray source: –Source model previously published in: Jarry, et al. Phys Med Biol 2003;48(16):2645–63. DeMarco, et al. Phys Med Biol 2005;50(17):3989–4004. –Detailed descriptions of source: X-ray spectra (from manufacturer). Beam filtration including the bowtie filter (from manufacturer). Beam collimation in the longitudinal (z) direction. Source movement for helical scan of arbitrary pitch. Agreement between simulation and measurement shown to be within 3.5% in phantom (Jarry et al and DeMarco et al).

Monte Carlo Simulation Method: Creating a Voxelized Model Contoured Image Voxelized Model Original Image Using CT image data from patients who were scanned for clinical indications (such as motor vehicle accident), create voxelized models for simulation. Radiologist contoured uterus and gestational sac (when visible).

Monte Carlo Simulation Method: Modeling the CT Source Modeled GE LightSpeed kVp, body bowtie filter 4 x 5-mm nominal beam collimation Dose reported on a per-100-mAs basis

Monte Carlo Simulation Method: Modeling the Scan Abdomen/pelvis scan: Just above liver to below pubic symphysis Helical scan, pitch = 1 (for reference) Can be adjusted for pitch = Only one series

Monte Carlo Simulation Method: Results In our inventory of cases, we had two patients who were 7 weeks pregnant:  Patient 1 was 134 pounds (no info on height, but perimeter was approximately 95 cm at level of fetus).  Patient 2 was 137 pounds (no info on height, but perimeter was approximately 86 cm at level of fetus).  Estimated fetal doses for 200-mAs pitch scan: –Patient 1: 17.8 mGy –Patient 2: 24.3 mGy

Comparing Results Felmlee, Gray, et al (standard-sized patient): 21.9 mGy ImPACT method (standard-sized patient): 29 mGy Monte Carlo method (Angel et al): 17.8–24.3 mGy

Implications of Results With estimated radiation dose to fetus in the 15–30-mGy range, what are the implications for a 7-week-old fetus? While there may be a wide variation among individual patients and in estimates from different methods: Fetal doses from a single abdomen/pelvis CT exam are still below the consensus levels for negligible risk (50–150 mGy) and well below “actionable” levels of 150 mGy. References: McCollough CH, Schueler BA, Atwell TD, et al. Radiation exposure and pregnancy: when should we be concerned? RadioGraphics 2007;27(4):909–17. Wagner, et al. Exposure of the pregnant patient to diagnostic radiations. Madison, WI: Medical Physics Publishing, 1997.