Enzyme Assay Enzyme assays are done to study the kinetics of the particular enzyme from any source and the factors that affect its activity like substrate.

Slides:



Advertisements
Similar presentations
SURVEY OF CHEMISTRY LABORATORY I SPECTROPHOTOMETRIC DETERMINATION
Advertisements

Spectrophotometers and Concentration Assays
8 reaction lab.
ALGALTOXKIT F Test procedure. 1 PREPARATION OF ALGAL CULTURING MEDIUM - VOLUMETRIC FLASK (1 liter) - VIALS WITH NUTRIENT STOCK SOLUTIONS A (2 vials),
بسم الله الرحمن الرحيم UMM AL-QURA UNIVERSITY Faculty of Medicine Dep. Of BIOCHEMISTRY.
Basic Instrumentation Handling the instruments form the basis of the practical knowledge and learning its mechanism of working ensures the proper handling.
Investigating Catalase Topic 3 IB Internal Assessment.
SDS-PAGE gel analysis SDS-PAGE analysis is done to study the expression of a protein from the control and the sample, to detect the molecular weight of.
Introduction to Instrumental Analysis - Spectrophotometry
COLORIMETRYCOLORIMETRY Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit Note: A printed description of.
Laboratory equipment.
TITRATION This involves removing small samples from the reaction mixture at different times and then titrating the sample to determine the concentration.
Spectrophotometry and Plotting of Calibration Curve
Affinity Chromatography Affinity chromatography is based on the principle of specific interaction between the protein or antigen and antibody for separation.
Methodology for the extraction of Plasmodium protein
Exercise #6 PHOTOSYNTHESIS photosynthesis In the process of photosynthesis, several energy transformations take place. -Light energy is captured by plant.
Welcome This is a template to create an Instructional Design Document of the concept you have selected for creating animation. This will take you through.
Look Ma! No Hands! A Chemical Clock Labettini The purpose of this labettini is to illustrate that chemical reactions don’t happen instantly, but proceed.
Experiment : Solutions Preparation, Part 2
SPECTROPHOTOMETRY. Determines concentration of a substance in solution by Measures light absorbed by solution at a specific wavelength by using spectrophotometer.
Spectrophotometry and Plotting of Calibration Curve BIO-2.
(glass pipette, centrifuge, spectrophotometry)
Spectrophotometers and Concentration Assays
Mastering the micropipette. What is a micropipette? How do you use a micropipette? How can I determine if I’m pipetting correctly?
Exp. 18: Spectrophotometric Analysis: Concentration of a Solution Using Beer’s Law White light violet (400nm) – red (800nm) “visible spectrum” sample (light.
Gel Filtration Chromatography The method mostly involves the separation of the proteins based on its molecular size. This method is also known as Size.
Lab Instructions. Materials and Equipment Distilled Water Zinc metal Filter Paper Plastic Wash Bottle Copper II sulfate Tap water Pencil (not a pen) Plastic.
CLS 332 CLINICAL INSTRUMENTAL ANALYSIS. A VISIBLE ABSORPTION SPECTROMETER.
 Related Los: Dye binding properties > Prior Viewing – IDD-17. SDS-PAGE, IDD-18. Second dimension separation of proteins > Future Viewing – IDD-22. 2D-gel.
 Related LOs: Sonication > Prior Viewing – IDD-1. Extraction of bacterial protein, IDD-6. Extraction of serum protein. > Future Viewing – IDD-11. Protein.
Gaussian Smoothing Gaussian Smoothing is the result of blurring an image by a Gaussian function. It is also known as Gaussian blur.  Course Name: Digital.
Linear Search Linear Search is a fundamental search algorithm. Linear search, also known as sequential search, is a process that checks every element in.
Go-Back-N ARQ (Sliding Window Protocol) Go-Back-N is an instance of the Automatic Repeat-request (ARQ) Protocol, in which the sending process continues.
Experiment: Solutions Preparation, Part 1 1CHE116.
COLORIMETRY & SPECTROPHOTOMETR
General Laboratory Techniques Dry Lab Chemistry 1105.
Spectrophotometers and Concentration Assays Chapter 7.
Absorption Spectrum for Plant Pigments
Absorption spectrum and spectrophotometric determination of concentration Experiment 1.
Related Los: Eexcitation and Emission property, Pixels > Prior Viewing- IDD-11. Protein quantification, IDD-13. Cyanine dye labeling, IDD- 14. Isoelectric.
枣庄学院化学化工与材料科学学院 Preparation of Solution. 枣庄学院化学化工与材料科学学院 1. Grasp the basic Method and Operation of Preparing Solution 2. Study the Method of Use about.
Sub-Cellular Fractionation
Lab1 A VISIBLE ABSORPTION SPECTROMETER. -One of the simplest and most widely used methods to determine concentration of a substance in solution -Measures.
Theory of Spectrophotometry
Spectrophotometry Measuring Concentrations of Substances in Body Fluids.
S2 Chemistry Rates of Reactions.
Lab1 A VISIBLE ABSORPTION SPECTROMETER
Methodology for the Second Dimension Separation
Ion Exchange Chromatography
Concentrations that absorb
Chemical Clock Labettini
Methodology for the extraction of proteins from serum
Methodology for the Quantification of protein
Principles and practice of Spectrophotometer
Methodology for the labeling of proteins with cyanine dyes
322 BCH Method of Enzyme Assay.
Spectrophotometric Determination [Co2+]
Methodology for the extraction of Bacterial protein
Bottle containing ammonium nitrate
Methodology for the Equilibration of the strips
Utilizing Spectrophotometry in Life Science
INTRODUCTION TO SPECTROPHOTOMETRY
Identification of the common laboratory glassware, pipettes and instruments . BCH 312 [PRACTICAL]
Binary Search A binary search algorithm finds the position of a specified value within a sorted array. Binary search is a technique for searching an ordered.
Exp. Iron in Vitamin Tablet
Spectrophotometer.
Solution Preparation Experiment
Identification of the common laboratory glassware, pipettes and instruments . BCH 312 [PRACTICAL]
Clinical instrumental analysis
Image Sharpening using Laplacian
Presentation transcript:

Enzyme Assay Enzyme assays are done to study the kinetics of the particular enzyme from any source and the factors that affect its activity like substrate concentration, pH and temperature  Related LOs: Enzyme kinetics > Prior Viewing – IDD-32. Buffer preparation for western analysis, IDD-50 basic instrumentation > Future Viewing – IDD-17. SDS-PAGE, IDD-33. Western blot assay  Course Name: Enzyme Assay  Level(UG/PG): UG  Author(s): Dinesh Raghu,Vinayak Pachapur  Mentor: Dr. Sanjeeva Srivastava *The contents in this ppt are licensed under Creative Commons Attribution-NonCommercial-ShareAlike 2.5 India license

Learning objectives After interacting with this Learning Object, the learner will be able to: 1. Define the enzyme extraction from the sample. 2. Determine the importance of enzyme kinetics 3. Operate to work with UV-Visible spectrophotometer 4. Infer the mechanism behind the spectrophotometer

Master Layout Reagent preparations (Slide: 5-11) Enzyme extraction (Slide: 12-14) UV-Visible spectrophotometer (Slide: 15-16) Spectrophotometric analysis (Slide: 21-24) Beer-Lambert’s Law (Slide: 17-18) Enzyme assay (Slide: 19-20)

Definitions and Keywords Beer –Lambert’s law: the law relates the absorbance and the concentration of the solution In the equation L signifies the path length, C concentration, E(epsilon) absorption coefficient and Io and I corresponds to the intensity of light before entering the solution and the intensity after coming out of the solution. The intensity of the light coming out of the cuvette decreases when the concentration of the substances in the cuvette increases. This is the law that governs the spectrophotometric analysis 2. Peroxidase: the enzyme that acts on hydrogen peroxide and convert it to water and oxygen 3.TMB: 3,3’,5,5’ Tetramethyl benzidine, an organic substrate which remains colorless in reduced form and once oxidized it turns blue 4. Rate of the reaction: Velocity at which the reaction occurs, substrate getting converted into the product

Step 1: Audio Narration (if any) ‏ Description of the action Show a measuring balance, with display, ON, OFF and TARE/0 buttons on it. let user ON it, display reading as 0.000g, let user picks up the paper from the rack, makes 1/10 of folding on the sides and places it on the balance. Now the display reading changes to 0.003g. Instruct user to TARE the reading. And animate to click the tare button. Once user clicks it, reading must show ”0” T1:Reagents for enzyme assay When measuing with paper, the weight of the paper need to be tared from actual reading.

Beaker Magnetic bead Audio Narration (if any) ‏ Description of the action Show magnetic stirrer instrument. Let user place the beaker on it. Display the beaker containing powder at bottom, liquid layer on top and a magnetic bead at the bottom. Instruct user to ON the instrument, let user cotrol the speed nob and regulate it accordingly to control the mixing speed in the beaker. Animate powder getting into the solution. Show a turbid solution turning colorless Step 1: T1:Reagents for enzyme assay

Step 2: Audio Narration Description of the action Let user pick up tetramethyl benzidine bottle,(TMB) spatula, measuring cylinder from the rack and keeps it on the table next to balance. Instruct user to weigh 0.5g of TMB, let user tare the balance, user should click on the TMBbottle, uncap it, with help of spatula weigh the required amount on a paper over the balance. Display a gradual increase in reading with quantity addition. if the gram exceeds user should remove some quantity or if it less add the quantity to get the exact required amount. After weighing transfer the quantity to beaker. Now instruct the user to measuring cylinder and water pour the water in the cylinder till the volume shows 90ml and show like mixing as in slide 6 and add 10ml to make the volume to 100ml. TMB Prepare 0.5% of 3,3,5,5 tetramethylbenzidine wa ter T1:Reagents for enzyme assay

Step 1: Audio Narration Description of the action Let user pick up citric acid monohydrate, spatula, measuring cylinder from the rack and keeps it on the table next to balance. Instruct user to weigh 210g of citric acid, let user tare the balance, user should click on the citric acid bottle, uncap it, with help of spatula weigh the required amount on a paper over the balance. Display a gradual increase in reading with quantity addition. if the gram exceeds user should remove some quantity or if it less add the quantity to get the exact required amount. After weighing transfer the quantity to beaker. Now instruct the user to measuring cylinder and water pour the water in the cylinder till the volume shows 900ml and show like mixing as in slide 6. Citric acid monohydrate Prepare 1.0M citrate buffer of pH 6 wa ter T1:Reagents for enzyme assay

Step 2: Audio Narration Description of the action Before the pH reading, pH instrument need to be calibrated with standards. Once with STD 1 at pH 4 and with STD 2 at pH 9. STD 1 STD 2 Display standard pH bottles and pH instrument and deionized water, discard placed on a table. Instruct user to caliberate the instrument. Let user ON the instrument. Initially for the pH rod is dipped in water, when user clicks on read button, display must show a reading “7”. Now show like taking out the rod and washing it with deionized-water, let user cleans the rod with tissue. Now pick the STD 1, uncap it, dip the cleaned rod into the solution, user must click read button with display showing “4”. now clean the rod and repeat the step to note down the reading for STD 2 and now the display should show “9”. T1:Reagents for enzyme assay

Step 3: Audio Narration Description of the action Instruct user to set the pH for TBST pH at 6. Now take the TBST bottle, uncap it, dip the cleaned pH rod into the solution. User need to click on read button. Initially display must show a reading 4. now instruct user to add NaOH to adjust the pH. Now allow the user to click on NaOH bottle so that drops of NaOH should be added with filler, user need to mix the solution with glass rod, click on read button and the reading should anywhere near let user keeps adding the NaOH drop till the pH display shows 6 and later transfer the beaker solution to 1000ml measuring cylinder to makeup the volume to 1000ml by clicking on water and adding it to that. All action should happen when the user clicks the hand image. NaOH HCl Prepare 1.0M citrate buffer of pH 6 T1:Reagents for enzyme assay

Step 4: Audio Narration Description of the action Animator should show a radish on the table, and a knife let the user click on knife to remove the coat of the radish, now let the user cut a small piece of radish and weigh it to 0.05g, Now show a ice bucket and the user should place a mortar and pestle on it, let the user place the radish pieces in the mortar and click on the bottle labeled as “citrate buffer” and set the pipette 1000ul and take the buffer and add to pestle, now instruct the user to click on pestle for grinding the tissue after it was ground well, instruct the user to add the buffer 3 times as shown earlier. Weigh the required amount of radish and place it in the prechilled mortar and pestle, grind it properly for a uniform phaste. ice Mortar /pestle T1:Reagents for enzyme assay

Step 5: Audio Narration Description of the action Now show a tea filter and a beaker, instruct the user to filter the ground radish solution paste. Let user place place the tea filter over the beaker and lift the motor, to tilt it to pour the liquid solution through the filter into the beaker. Let user collect the solution in the beaker for further processing. Add 4ml of Citrate buffer and grind well, Filter the ground paste using the filter. T2: Enzyme extraction

Step 6: Audio Narration ‏ Description of the action Now instruct the user to take the measuring cylinder and citrate buffer, animate like the user pouring the citrate buffer to the cylinder till the volume reaches 96 ml and add to the beaker with radish extract. Make up the volume of the extract to 100ml using the buffer such that the extract contains 100units of enzyme/ml of the buffer T2: Enzyme extraction

Step 7: Audio Narration Description of the action Let user pick up water bottle and the pipette to take 2.77ml in the pipette and add to the tube-1 in stand again repeat the same for other to tubes, Now instruct the user to take the pipette set to 30ul and take the citrate buffer pipette out and add to the tube-1 follow the same for tube-2. Prepare the tubes for the assay, do not add the enzyme or the TMB or Hydrogen peroxide before everything is ready. wa ter Citrate buffer TMBTMB Extr act Hydrogen peroxide 1 2 T2: Enzyme extraction

Step 8: Lid that can be opened Display Options like number 0-9, set wavelength, autozero, absorbance T3:UV-Visible spectrophotometer cuvette

Step 8: Audio Narration ‏ Description of the action Animate the instrument as in figure and redraw the instruments with the specification mentioned in the figure and zoom the instrument and show a schematic as shown in the figure with the labelings but redraw completely UV-Visible spectrophotometer has a monochromator, light source and sample holder and detector, Light from the source are converted to a monochromatic light of particular wavelength and allow it pass through the sample and amount of light that emerges is detected by a detector. T3: UV-Visible spectrophotometer

Step 9: L T4: Beer-Lambert’s Law

Step : Audio Narration Description of the action Now show the figure as in slide above (redraw) followed by the formula which is given in the slide, audio narration should take place simultaneously UV-Visible spectrophotometer works on the basis of Beer-Lambert’s law, the law relates the absorbance and the concentration of the solution,. In the equation L signifies the path length, C concentration, E(epsilon) absorption coefficient and Io and I corresponds to the intensity of light before entering the solution and the intensity after coming out of the solution. The intensity of the light coming out of the cuvette decreases when the concentration of the substances in the cuvette increases. T4: Beer-Lambert’s Law

Step 10: Audio Narration Description of the action Instruct the user to set the spectrophotometer by switching on “click set wavelength and type 655nm” and press enter. Let user pick up TMB and instruct the user to take the pipette set to 50ul and take the TMB, pipette out and add to the tube-1 and follow same for tube-2. Let user pick up extract and instruct the user to take the pipette set to 50ul and take the extract, pipette out and add to the tube-1 follow the same to add to tube- 2. Show like the user taking the tubes and mixing by shaking it.. Set the wavelength of 655 nm in UV –visible spectrophotometer Prepare the control and assay solution. water Citrate buffer TMB Extr act Hydrogen peroxide T5: Enzyme assay 1 2

Step 10: Audio Narration ‏ Description of the action Let the user take the tube-1 and take 2 cuvettes as in figure. Instruct the user to press the open lid show two opening inside it one after the other in longitudinal way. Show like pouring the contents from tube-1 to both the cuvettes, show like taking the tissue and wiping on the sides and placing it in the openings, now animate like closing the lid and press absorbance. (before keeping the cuvette the reading should be 0.000, once the cuvette is kept and “absorbance is pressed it should be 0.123) Now instruct the user to press ”auto zero” and the reading should be and remove the cuvette by opening the lid and taking out the cuvette from opening 2 discard the solution out from the cuvette. Auto zero and callibrate the instrument using the control solution without hydrogen peroxide T5:: Enzyme assay

Step 11: Audio Narration ‏ Description of the action Instruct the user to click on hydrogen peroxide and a pipette set to 100ul and take the peroxide solution and add to the tube-2 and show like mixing and show like the user switching on stop clock. Once it has reached 15sec. 2.Let the user take the tube-2 and take cuvette as in figure. Show like pouring the contents from tube-2 to one of the cuvettes, show like taking the tissue and wiping on the sides and placing it in the openings, now animate like closing the lid and press absorbance. (before keeping the cuvette the reading should be 0.000, once the cuvette is kept and “absorbance is pressed it should be and animate like user making a note of the reading. Once this has done show like removing cuvette 2 and discarding the solution and wait till the stop clock shows 30 sec again start step-2 as in slide and repeat it for every 15 seconds until 2minutes. Animate the steps as per the instructions. Show the solution in blue color and as the time goes on show the color getting darker. Add the hydrogen peroxide to the assay tube and take readings for every 15seconds for a total of 2mins. The peroxidase in the extract reacts with the hydrogen peroxide and releases water and oxygen molecule, the released oxygen molecule oxidize the tetramethyl benzidine thereby giving the blue color as the time increases, oxygen release increases and color intensity also increases T6: spectrophotometeric analysis

Step 15: Time (seconds)OD at 655nm T6: spectrophotometeric analysis

Step 16: Time in seconds OD at 655 nm T6: spectrophotometeric analysis

Step 15 and 16: Audio Narration Description of the action Instruct the user to plot the graph as OD in y axis and the time in x axis and show like a straight line is drawn (red line) connecting time and OD. Instruct the user to determine the rate of the reaction. Plot the graph between OD at 655nm and the time in seconds of the sample and draw the line joing the points and determine the rate of the reaction by calculating the ration of change in absorbance at 655nm and the time elapsed since the start of the reaction. T6: spectrophotometeric analysis

Animation area Instructions/ Working area Credits Name of the section/stage Interactivity area Tab 02Tab 03Tab 04Tab 05Tab 06Tab 07 Button 01 Button 02 Button 03 Tab 01 Slide Slide Slide Slide Slide Slide Interactions: Slide: Show like the user set the wrong wavelength say 400nm and started taking the readings, show like the readings are in the negative region Instruction : Instruct the user to reset the wavelength to 655nm and start taking the reading. If the exact wavelength range has not set, the readings will be deviating from the exact value to be obtained

Questionnaire: APPENDIX 1 Question 1 Absorbance can be taken using a)Calorimetry b)Spectroscopy c)spectrophotometry d)Refractometry Question 2 UV-Visible spectrophotometer works based on a)Beers law b)Lamberts Law c)Beer-Lamberts Law d)Raman spectrum Question 3: As the absorbance increases, the intensity of the out coming light a)Decreases b)Increases c)Remains same d)zero

Questionnaire: APPENDIX 1 Question 4: Rate of the reaction means a)Mechanism at which the reaction occurs b) Speed at which the reaction occurs c) Velocity at which the reaction occurs d) Reaction time Question 5: TMB on oxidation gives a)Orange color b)Red color c)Purple color d)Blue color

Links for further reading Reference websites: 1. ojects/addlprocedures/AP-VEnzymes.pdf 2. ter_theory.pdf Book Biochemistry by Voet & Voet, 3 rd edition APPENDIX 2

Summary APPENDIX 3 The method mostly involves the study of kinetics of the enzyme reactionn. Steps involved are preparation of control and assay tube, preparation of citrate buffer, TMB, enzyme extract and hydrogen peroxide addition, spectrophotometric analysis.