TERMINAL CHARCATERISTIC of a SHUNT DC MOTOR

Slides:



Advertisements
Similar presentations
ENERGY CONVERSION ONE (Course 25741)
Advertisements

ENERGY CONVERSION ONE (Course 25741)
Chapter 6 DC and AC Machines
Basics of a Electric Motor
Power System Fundamentals
SYNCHRONOUS MACHINES SUBMITTED BY: Ms. APOORVA KANTHWAL
DC Motors KL3073.
Synchronous Machines.
SYNCHRONOUS GENERATORS
SEE 3433 ELECTRICAL MACHINES Classification of DC machines DC Generators - Separately excited - Armature reaction.
Direct – Current Motor Characteristics and Applications
Elec467 Power Machines & Transformers
Lecture 32 DC Motors Part II
ET 332a Dc Motors, Generators and Energy Conversion Devices 1.
Lesson 11: Separately Excited Motor Examples
BASIC ELECTRICAL TECHNOLOGY DET 211/3
Lesson 17: Other Dc Motor Connections
DC Motors:.
Synchronous Generator
DC motors.
ENERGY CONVERSION ONE (Course 25741) CHAPTER NINE ….continued DC MOTORS AND GENERATORS.
ENERGY CONVERSION ONE (Course 25741)
ET 332a Dc Motors, Generators and Energy Conversion Devices 1Lesson a.pptx.
Lesson 19: Non-Linear Operation of Dc Motors ET 332a Dc Motors, Generators and Energy Conversion Devices 1Lesson a.pptx.
ET 332a Dc Motors, Generators and Energy Conversion Devices 1Lesson a.pptx.
ENERGY CONVERSION ONE (Course 25741) CHAPTER SIX (& S.G. parallel op. with Pow. Sys. of chapter 5) SYNCHRONOUS MOTORS.
ET 332a Dc Motors, Generators and Energy Conversion Devices 1 Lesson a.pptx.
FUNDAMENTAL OF ELECTRICAL ENGINEERING EMT 113/4
ENERGY CONVERSION ONE (Course 25741)
Interpoles.
Electro Mechanical System
Chapter 6 DC Machines EET103/4.
Fundamental of Electrical Engineering
EMT 462 ELECTRICAL SYSTEM TECHNOLOGY
Direct-current motor is a device that transforms the electrical energy into mechanical energy. There are five major types of dc motors in general use:
EET 221 Synchronous Machines Rafiqi.
Chapter 6 Synchronous Motors
DC Machines.
DC MOTORS.
ELEC 3105 Basic EM and Power Engineering Rotating DC Motor PART 2 Electrical.
Speed Control in DC Motors
BASIC ELECTRICAL TECHNOLOGY DET 211/3
SMJE 2103 DC Motors. DC Motor Discussion topics: 1.Basic structure 2.Field circuit connections 3.Equivalent circuit 4.Induced torque 5.Terminal characteristics.
SMJE 2103 Synchronous Generator. Scope of discussion 1)Construction 2)Rotation speed 3)Generated voltage 4)Equivalent circuit 5)Power and Torque 6)Testing.
Prepared by: MANISH G. CHAVDA ( ) MILAN DHAMELIYA ( ) JANAK GOTI ( ) JAYDEEP GAJERA ( )
OPERATING CHARACTERISTICS OF DC GENERATOR
D.C.Generator.
Synchronous Generator
DC GENERATORS Introduction The outstanding advantages of dc machines arise from the wide variety of operating characteristics which can be obtained by.
Lecture 14Electro Mechanical System1  Current flowing in the armature coils creates a powerful magnetomotive force that distorts and weakens the flux.
DC MOTORS AND GENERATORS
CHAPTER 3 DC MOTOR Electrical Machines.
BASIC ELECTRICAL TECHNOLOGY DET 211/3
DC GENERATORS G H PATEL COLLEGE OF ENGINEERING & TECHNOLOGY
Topic :- Characteristics Of DC Motor
TOPIC: ARMATURE REACTION ENROLLMENT NO:
ELEC 3105 Basic EM and Power Engineering
Electric Machine DC Generator (2)
Chapter 6: DC & AC Machine
DC Motors:.
Shantilal Shah Engineering College
Electric Machinery DC Machines A.E. Fitzgerald Charles Kingsley, Jr.
EMT 113/4 ELECTRICAL ENGINEERING TECHNOLOGY
ELECTRICAL ENGG. DEPARTMENT SPEED CONTROL OF DC SERIES MOTOR
DC Machines Fundamentals
Advanced Power Systems
Electric braking Powerpoint presentation by:- Poonam sharma
Induction Motor Drives
DC Motors Starters and Breaking Methods
Chapter 29 D.C. Motor. Chapter 29 D.C. Motor D.C. Motor C-29 Motor Principle Comparison of Generator and Motor Action Significance of the Back e.m.f.
Presentation transcript:

TERMINAL CHARCATERISTIC of a SHUNT DC MOTOR If a shunt dc motor has compensating windings so that flux is constant regardless of load, & motor’s speed & armature current known at any one value of load , then speed at any other load can be determined if IA is known at that load EXAMPLE-1: A 50 hp, 250 V, 1200 r/min dc shunt motor with compensating windings, RA =0.06 Ω (including brushes, comp. windings, & inter-poles). The field cct. has a total resistance of Radj + RF of 50 Ω which develops a no load speed of 1200 r/min. There are 1200 turns per pole on shunt field winding

TERMINAL CHARCATERISTIC of a SHUNT DC MOTOR Find speed of this motor when its input current is 100 A (b) Find speed of this motor when its input current is 200 A (c) Find the speed of this motor when its input current is 300 A (d) plot torque-speed characteristic of this motor

TERMINAL CHARCATERISTIC of a SHUNT DC MOTOR EXAMPLE-1;SOLUTION: EA=K’φn, since IF is constant (VT & RF const.) & since there are no A.R. φ would be constant  relationships between speeds & internal generated voltages of motor at 2 different load conditions is: EA2/EA1=[K’φn2]/[K’φn1] constant K’ cancels, also φ canceled  n2= EA2/EA1 . n1 at no load IA is zero so EA1=VT=250 V While speed n1=1200 r/min If internal generated voltage at any other load is determined, motor speed at the load can be determined

TERMINAL CHARCATERISTIC of a SHUNT DC MOTOR (a) if IL=100 A then armature current : IA=IL-IF=IL- VT / RF =100 – 250/ 50=95 A  EA=VT-RAIA=250 –(95)(0.06)=244.3 V Resulting speed: n2=EA2/EA1xn1=244.3/250 x1200=1173 r/min (b) IL=200 A  IA=200-250/50=195 A EA=250-(95)(0.06)=238.3 V n2= 238.3/250 x1200=1144 r/min

TERMINAL CHARCATERISTIC of a SHUNT DC MOTOR (c) if IL=300 A, then IA=IL-IF=300-250/50=295 A EA = 250-(295)(0.06)=232.3 V n2=232.3/250 x 1200=1115 r/min (d) torque versus speed At no load induced torque is zero Pconv=EAIA=Tind ω From this equation Tind= EAIA / ω IL=100 A  Tind=(244.3)(95)/ [1173x1/60x2π]=190 N.m. IL=200 A  Tind= 238.3x195/[1144x1/60x2π]=388 N.m. IL=300 A  Tind=587 N.m.

TERMINAL CHARCATERISTIC of a SHUNT DC MOTOR Torque – speed characteristic of motor

NONLINEAR ANALYSIS of a SHUNT DC MOTOR flux φ & EA of a dc machine is a nonlinear function of mmf  anything that changes mmf cause a nonlinear effect on EA mmf should be used to determine EA & mmf determined based on field current and A.R. magnetization curve is a direct plot of EA versus IF for a given speed ω0  effect of variation in field current can be determined directly from its magnetization curve

NONLINEAR ANALYSIS of a SHUNT DC MOTOR If a machine has armature reaction, its flux will be reduced with each increase in load. The total mmf in a shunt dc motor is the field circuit mmf less the mmf due to armature reaction (AR): Fnet = NFIF – FAR magnetization curves are expressed as plots of EA vs field current, normally an equivalent field current is defined that would produce the same output voltage as the combination of all the mmf in the machine The equivalent field current :

NONLINEAR ANALYSIS of a SHUNT DC MOTOR one other effect must be considered when non linear analysis is used to determine EA of a dc motor The magnetization curves for a machine are drawn for a particular speed, usually the rated speed of the machine How can the effects of a given field current be determined if the motor is turning at other than rated speed? The equation for the induced voltage in a dc machine when speed is expressed as rev/min: EA = K’φn , For a given effective field current, the flux in the machine is fixed, so the EA is related to speed by

NONLINEAR ANALYSIS of a SHUNT DC MOTOR EXAMPLE-2: A 50 hP, 250V, 1200r/min DC shunt motor without compensating windings has an armature resistance (including the brushes and interpoles) of 0.06 . Its field circuit has a total resistance Radj + RF of 50 , which produces a no-load speed of 1200 r/min. There are 1200 turns per pole on the shunt field winding, and the armature reaction produces a demagnetising mmf of 840 A.turns at a load current of 200A. magnetization curve of this machine is shown next

NONLINEAR ANALYSIS of a SHUNT DC MOTOR Magnetization Curve of typical 250 V dc motor Example -2

NONLINEAR ANALYSIS of a SHUNT DC MOTOR Torque-speed characteristic of motor with armature reaction

SPEED CONTROL of SHUNT DC MOTOR Two common methods: 1- Adjusting the field resistance RF (and thus the field flux) 2- Adjusting the terminal voltage applied to the armature Less common method: 3- Inserting a resistor in series with the armature circuit

SPEED CONTROL of SHUNT DC MOTOR Changing the Field Resistance If the field resistance increases, field current decreases (IF↓ = VT/RF↑), and as the field current decreases, flux decreases as well. A decrease in flux causes an instantaneous decrease in the internal generated voltage EA↓ (=Kφ↓ω), which causes a large increase in the machine’s armature current since

SPEED CONTROL of SHUNT DC MOTOR Induced torque in a motor is given by ind =KφIA since flux in machine decreases while current IA increases, which way does the induced torque change? Look at this example:  armature current flow is IA=(250V-245V)/ 0.25Ω= 20A

SPEED CONTROL of SHUNT DC MOTOR What happens in this motor if there is a 1% decrease in flux? If the flux decrease by 1%, then EA must decrease by 1% too, because EA = Kφω Therefore, EA will drop to: EA2 = 0.99 EA1 = 0.99 (245) = 242.55 V armature current must then rise to IA = (250-242.55)/0.25 = 29.8 A Thus, a 1% decrease in flux produced a 49% increase in armature current

SPEED CONTROL of SHUNT DC MOTOR back to original discussion, the increase in current predominates over the decrease in flux so, ind>load , the motor speeds up However, as the motor speeds up, EA rises, causing IA to fall. Thus, induced torque ind drops too, and finally ind equals load at a higher steady-sate speed than originally Summarizing behaviour: 1- increasing RF causes IF (=VT/RF) to decrease 2- decreasing IF decrease φ

SPEED CONTROL of SHUNT DC MOTOR 3 – Decreasing φ lowers EA(=Kφω) 4 - Decreasing EA increases IA (=VT-EA)/RA 5- increasing IA increases Tind (=KφIA), with change in IA dominant over change in flux 6-increasing Tind makes Tind>Tload & speed ω increases 7-increase in ω, increases EA= Kφω again 8-increasing EA decreases IA 9-Decreasing IA decreases Tind until Tind=Tload at a higher ω Effect of increasing RF on O/P characteristic of a shunt motor shown in next figure

SPEED CONTROL of SHUNT DC MOTOR Effect of RF speed control on a shunt motor’s torque-speed (over motor’s normal operating range)

SPEED CONTROL of SHUNT DC MOTOR Effect of RF speed control on a shunt motor’s torque-speed (over entire range from no-load to stall conditions)

SPEED CONTROL of SHUNT DC MOTOR According to equation of speed presented before: (a) no-load speed is proportional to reciprocal of flux in motor (b) while slope of the curve is proportional to reciprocal of flux squared Therefore a decrease in flux causes slope of torque-speed to become steeper over this range, an increase in field resistance increases motor’s speed For motors operating between no-load & full-load conditions, an increase in RF may reliably be expected to increase operating speed

SPEED CONTROL of SHUNT DC MOTOR In previous figure (b) terminal characteristic of motor over full range from no-load to stall shown In figure can see at very slow speeds, an increase in field resistance will actually decrease speed of motor This effect occurs because at very low speeds, the increase in armature current caused by decrease in EA not enough to compensate for decrease in flux in induced torque field resistance Some small dc motors used for control purposes operate at speeds close to stall conditions For these motors, an increase in RF might have no effect or it might even decrease speed of motor Since the results are not predictable, field resistance speed control should not be used in these types of dc motors. Instead, the armature voltage method should be employed

SPEED CONTROL of SHUNT DC MOTOR CHANGING ARMATURE VOLTAGE This method involves changing the voltage applied to the armature of the motor without changing the voltage applied to the field If the voltage VA is increased, then the IA must rise [ IA = (VA ↑ -EA)/RA]. As IA increases, the induced torque ind =KφIA↑ increases, making ind > load , and the speed of the motor increases But, as the speed increases, the EA (=Kφω↑) increases, causing the armature current to decrease This decrease in IA decreases the induced torque, causing ind = load at a higher rotational speed

SPEED CONTROL of SHUNT DC MOTOR Effect of armature voltage speed control

SPEED CONTROL of SHUNT DC MOTOR Inserting a Resistor in Series with the Armature Circuit If a resistor is inserted in series with the armature circuit, the effect is to drastically increase the slope of the motor’s torque-speed characteristic, making it operate more slowly if loaded. This fact can be seen from the speed equation: The insertion of a resistor is a very wasteful method of speed control, since the losses in the inserted resistor are very large. For this reason, it is rarely used