Manufactured Homes: Heat Pump Related Measures Regional Technical Forum Presentation August 18 th, 2015.

Slides:



Advertisements
Similar presentations
New MT Houses with Ground Source Heat Pumps Energy Savings and Costs June 2 nd, 2009 Regional Technical Forum 1.
Advertisements

Sunset Date Extension: Manufactured Homes HVAC Measures Regional Technical Forum November 18 th, 2014.
SEEM Calibration: Revisited Revising the regression to use continuous heat loss variable Regional Technical Forum December 17, 2013.
Residential Single Family Clothes Washer UES Measure Update Christian Douglass Regional Technical Forum February 18, 2015.
The Saga Continues: Measure Interactions for Residential HVAC and Wx measures Regional Technical Forum April 23, 2014.
Ductless Heat Pumps in Manufactured Homes with Zonal Electric Resistance Heat Adam Hadley Regional Technical Forum February 18, 2015.
Oregon Energy Star Homes Measure Update New Measure Proposal April 22nd,
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Regional Technical Forum July.
Residential and Commercial Storage Electric Resistance Water Heaters (Efficient Tanks) Mohit Singh-Chhabra Regional Technical Forum February 18, 2015.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
NEEM Manufactured Homes Field Test Results David Baylon, Ecotope.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Prescriptive Duct Sealing UES Measure Proposal Regional Technical Forum Subcommittee July 8, 2013.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update May 12, 2015.
1 Proposed Changes to the RTF’s Heat Pump Specifications Impact on Estimated Deemed Savings and C&R Discount Program Credits.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
DHP for Houses with Electric FAF Provisional UES Measure Proposal Adam Hadley, Ben Hannas, Bob Davis Regional Technical Forum January 21, 2015.
Heat Pump Water Heaters: Tier 2 – Ducted Interior Installations Provisional UES Proposal Regional Technical Forum February 14 th, 2012.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF MH Calibration Subcommittee February 27, 2015.
Direction on Guidelines Savings Definition Path: CONTINUED Remaining Useful Life (RUL) and Measure Interaction Regional Technical Forum February 19, 2014.
New Measure Proposal Review and Prioritization Jennifer Anziano, Adam Hadley, Mohit Singh-Chhabra, Christian Douglass Regional Technical Forum February.
Manufactured Homes Calibration: Existing and New Homes Josh Rushton & Mohit Singh-Chhabra RTF Update June 16, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Regional Technical Forum August.
1 NORTHWEST ENERGY EFFICIENCY ALLIANCE Creating a DHP UES Measure Ecotope, Inc. July 16, 2013.
Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
Standard Information Workbook Update Regional Technical Forum May 21, 2013.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
HVAC and DHW System Conversion Cost and Energy Use Assumptions for Direct Use of Natural Gas Analysis September 28, 2010.
Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th,
RTF Management Update Jennifer Anziano Regional Technical Forum April 14, 2015.
Oregon ENERGY STAR Homes Measure Update Adam Hadley Regional Technical Forum March 17, 2015.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
QC Follow-up for Single Family SEEM Calibration, HVAC UES Measures, and Weatherization Measures Adam Hadley Regional Technical Forum May 12, 2015.
SEEM Calibration: Phase-2 Adjustments for Failed VBDD Fits Regional Technical Forum August 12, 2014.
Air Source Heat Pump Specifications Proposed Revisions Regional Technical Forum Subcommittee July 2, 2013.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum November 19, 2013.
1 Proposed Revisions to Deemed Savings Input Assumptions for PTCS Duct Sealing and Heat Pump Efficiency Upgrades and Duct Sealing, Commissioning and Controls.
Manufactured Homes Calibration: New Construction Regional Technical Forum September 22 nd, 2015 Mohit Singh-Chhabra.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
Residential Duct Insulation New Deemed Measure Proposal – A Second Look Regional Technical Forum May 4 th, 2010.
Variable Speed Heat Pumps Provisional UES Proposal Presentation to the Regional Technical Forum September 18, 2012 Presentation by Kacie Bedney, Bonneville.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum March 18, 2014.
1 Proposed Changes to the RTF’s Heat Pump Deemed Savings and Cost- Effectiveness Draft 6th Plan Assumptions April 7, 2009.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat Proven UES Measure Proposal Regional Technical Forum October 16, 2013.
ENERGY STAR and EcoRated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
PTCS Ducts Inside Single Family New Construction Energy Savings and Cost Regional Technical Forum May 5,
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Direct Use of Natural Gas Status of Analysis Staff Analysis Today’s Agenda: Review of Major Analytical Input Assumptions Present Preliminary Results (Not.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum June 16, 2015.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
Planning UES Measures: Prescriptive Duct Sealing SF Performance-based Duct Sealing SF Performance-based Duct Sealing MH Adam Hadley & Josh Rushton Regional.
RTF Management Update Jennifer Anziano Regional Technical Forum July 21, 2015.
Proposed Edits to the Air Source Heat Pump Specifications Regional Technical Forum August 20, 2013.
Non-Proven Residential Duct Sealing Measures: Research Strategy Josh Rushton and Adam Hadley Research and Evaluation Subcommittee October 7, 2015.
Implementer’s Group December Meeting Debrief and Upcoming Meeting Prep January 6, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
Implementer’s Group October 2015 RTF Meeting Debrief and Upcoming Meeting Prep October 29, 2015.
RTF’s Engagement with Research Jennifer Light RTF Policy Advisory Committee February 19, 2016.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Research Strategy: Residential Ductless Heat Pumps Research and Evaluation Subcommittee Christian Douglass and Josh Rushton January 8, 2016.
Single Family New Construction Measure: Slab Insulation Mohit Singh-Chhabra Regional Technical Forum April 19 th, 2016.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
Presentation transcript:

Manufactured Homes: Heat Pump Related Measures Regional Technical Forum Presentation August 18 th, 2015

Objective Seek RTF approval on Planning Measures’ (savings estimate and Research Strategy): Heat Pump Conversions Heat Pump Upgrades Commissioning Controls & Sizing (CC&S) Performance Based Duct sealing Note: R&E subcommittee “head-nod” on August 6 th on proposed Research Strategy 2

Background June RTF Meeting – RTF has an approved calibrated model for estimating heating energy and savings in MH with electric resistance heat – RTF does not have an approved calibrated model for estimating heating energy in MH with heat pumps Need to understand how heat pumps are working in manufactured homes to develop reliable per unit energy savings for related measures 3

Heat Pump Conversions 4

Measure Background Measure Name:Air Source Heat Pump Conversions MH Current Measure Category: Proven Proposed Measure Category: Planning Current Measure Status:Under Review Proposed Measure Status:Active Measure Sector:Residential (MH) End Use:HVAC Current Sunset Date:November,

Measure Specifications ASHP Conversion (8.5 HSPF) from FAF w/CAC: 18 measure applications defined by 3 heating zones, 3 insulation levels and 2 duct seal levels (with and without). ASHP Conversion (8.5 HSPF) from FAF w/o CAC: 54 measure applications defined by 3 heating zones, 3 cooling zones, 3 insulation levels and 2 duct seal levels (with and without). – Note: current measure upgrades to a 7.7 HSPF ASHP. This is below current federal standard for HP 6

Planning Measure: Energy Savings Estimates As the RTF does not have an approved calibrated model for estimating heating energy in MH with heat pumps, alternate sources for determining energy savings estimate were considered to develop planning savings estimates. Staff Proposal: Adjust Single Family Estimates to Determine Planning Estimate for MH – Note: All SF HP measures are planning due to CC&S Alternative options considered (explained later in the presentation): NEEA-Ecotope Heat Pump Study Estimates Zero Savings 7

Developing Adjusted SF Savings Estimates Proposal: use the SF HP Conversion savings, de-rate for smaller MH size (Ratio = 0.85) – SF weighted average home surface area calculated using RTF prototype, weighted to RBSA – MH weighted average surface area calculated using RBSA An alternate ratio based on heating energy consumption per home was considered. Clean data to support such a calculation is not readily available – Surface area ratio seems good enough for a planning measure 8

Adjusted SF Savings Estimates Pros: Use existing RTF approved estimates to develop savings for MH – Best proxy in the absence of a calibrated MH curve Allows the use of home insulation level as a measure identifier – Consistent with SF Measure Con: Assumes energy savings per square foot is similar between SF and MH which may not be true – Occupant behavior may be different etc. 9

Adjusted SF Savings Estimates – HP Conversions from eFAF w/ CAC 10

Adjusted SF Savings Estimates – HP Conversions from eFAF w/o CAC 11

Cost Cost methodology unchanged from approved SF Conversion Measure Cost of conversion depends on size of HP installed; size depends on heating load – Different for homes with “Good”, “Fair” and “Poor” insulation levels – Different for different heating zones 12

Incremental Cost: HP Conversions from eFAF w/ CAC 13

Incremental Cost: HP Conversions from eFAF w/o CAC 14

Cost Effectiveness (TRC) Results: HP Conversions from eFAF w/ CAC 15

Cost Effectiveness (TRC) Results: HP Conversions from eFAF w/o CAC 16

Alternative Option 1: NEEA-Ecotope Heat Pump Study Study conducted by Ecotope in 2005, one of the objectives was to estimate mean savings from HP conversions Energy savings calculated for HZ1 only. The study concluded that net calculated savings of “4,149 kWh is highly significant” – This estimate includes SF and MH – Savings determined for MH are: – Savings were found to vary by cooling zone within HZ1 17

Results be viewed as an aggregate, not sub-divided by categories – “… the breakdown of estimates into subsets of the study population suffers from missing information and small sample sizes for sub-categories” Calculated mean savings estimate should not be used for ex-ante purposes – “This savings estimate is a function of the specific mix of system types, climate zones and housing types in the sample; it may not reflect future program results.” Results applicable to HZ1 only; study advises that “…extending this analysis to colder climate zones cannot be done reliably” 18 Alternative Option 1: NEEA-Ecotope Heat Pump Study Conclusions

Alternative Option 2: Zero Savings Idaho Power data imply that “HP Conversion + Wx” sites saved similar energy to “Wx-only” sites 19 32% lower28% lower 30% lower 32% lower

Alternative Option 2: Zero Savings Zero savings are possible results of analysis of one low income program from one part of the region – We aren’t certain that HP Conversions yield no savings. The trend observed could be due to other indeterminable factors The 2005 NEEA-Ecotope HP study showed significant savings for HP conversions 20

Heat Pump Upgrades 21

Measure Background Measure Name:Air Source Heat Pump Upgrades MH Current Measure Category: Proven Proposed Measure Category: Planning Current Measure Status:Under Review Proposed Measure Status:Active Measure Sector:Residential (MH) End Use:HVAC Current Sunset Date:November,

Measure Specifications ASHP Upgrade to 9 HSPF 14 SEER in 3 heating zones and 3 cooling zones. ASHP Upgrade to 12 HSPF 18 SEER Variable Capacity Heat Pump (VCHP) in 3 heating zones and 3 cooling zones. 23

Planning Measure: Energy Savings Estimates As the RTF does not have a reliably calibrated model for estimating heating energy in MH with heat pumps, alternate sources for determining energy savings estimate were considered to develop planning savings estimates. Staff Proposal: Adjust Single Family Estimates to Determine Planning Estimate for MH – Note: All SF HP measures are planning due to CC&S Alternative options considered (explained later in the presentation): Zero Savings 24

Adjusted SF Savings Estimates Savings development follow same methodology as HP Conversion measures, adjust SF estimates using ratio developed using average floor area Option 1 makes the assumption that an increase in heating system efficiency will lead to energy savings Same pros and con as listed for HP Conversions 25

Adjusted SF Savings Estimate (kWh) 26

Incremental Cost Methodology unchanged from approved SF Upgrade measure Cost of upgrade to 9 HSPF = $81 – Source: SIW – Existing cost of upgrade (7.7 to 8.2 HSPF): $485 Cost of upgrade to VCHP = $4920 – Source: Cost data from Ecotope on commercially available models 27

Upgrade Cost Benefit Analysis (TRC) 28

Alternate Option: Zero Savings Idaho Power data imply that HP may behave similar to electric resistance heat systems. If this were true, then an increase in HP efficiency will not lead to energy savings Another possibility is that no savings are realized, due to comfort related–take-back Staff proposes using “Adjusted SF Estimates” as: – Consistent with HP Upgrades – Note, there is a significant efficiency upgrade in the case of VCHP. Assuming zero savings for these is a big leap 29

Commissioning Controls & Sizing (CC&S) 30

Measure Background Measure Name:Commissioning Controls & Sizing (CC&S) Current Measure Category: Planning Proposed Measure Category: Planning Current Measure Status:Under Review Proposed Measure Status:Active Measure Sector:Residential (MH) End Use:HVAC Current Sunset Date:March,

CC&S Background RTF approved Research Strategy already exists – One research strategy for SF and MH Measure is Under Review as current savings are not calculated using either RBSA calibration or Guidelines compliant measure interaction methodology (Option 3) 32

CAT Proposal for Planning Savings Use adjusted SF estimates – Same methodology as the HP Conversion and Upgrade measures – Methodology (adjust SF estimates) consistent with other MH HP Related measures – Don’t see any other viable option for Planning Savings Estimate 33

CC&S Planning Savings Comparison (kWh) 34

CC&S Cost Comparison Existing Cost: $393 Proposed Cost: $512 – Source – Standard Information Workbook 35

CC&S Cost Benefit Analysis (TRC) Comparison 36

Performance Based Duct Sealing 37

Measure Background Measure Name:Performance Based Duct Sealing Current Measure Category: Planning Proposed Measure Category: Planning Current Measure Status:Under Review Proposed Measure Status:Active Measure Sector:Residential (MH) End Use:HVAC Current Sunset Date:November,

Measure Technical Specifications Detailed Measure Specs available on the RTF websiteRTF website The air leakage of the duct system must be measured before and after sealing the system and must meet one of the following criteria: Must have a measured leakage of 50 CFM50 or less for a single section of home, plus an additional 30 CFM allowed for each additional section – If above is not possible, measured duct leakage after sealing should show a 50% reduction – If above is not possible, the air-handler transition to trunk duct connection must be sealed – Regardless of the qualifying path, all accessible components of the duct system must be sealed, including the crossover takeoff-to-truck duct connections and the crossover-to- crossover takeoff connections. 39

Planning Savings Estimate CAT Proposal: Assume Same Savings Estimate as Prescriptive Duct Sealing Measure Performance based duct sealing measure’s modeled savings estimate not supported by data – When CAT studied the BPA PTCS evaluation data for relationship between duct leakage reduction and energy savings, no relationship was found Note: This is a problem with the SF measure as well. No strong evidence that leakage reduction caused by Performance Duct Sealing is much different than leakage reduction due to Prescriptive Duct Sealing – Performance based duct seal now has Prescriptive post-seal requirements 40

Research Strategy 41

Research Strategy Scope Determine reliable energy savings estimates for: Heat Pump Conversions Weatherization with Heat Pumps – Currently measure under review due to no Research Strategy – Planning estimates exist; savings estimate same as Wx with electric resistance Performance Based Duct Sealing Commissioning, Controls, and Sizing Heat Pump Upgrades 42

R&E Subcommittee Review Subcommittee agrees with the proposed Research Strategy At subcommittee’s request: Includes language suggesting that research sponsors review the challenges, findings, and conclusions of previous studies (2005 NEEA HP Study and 1995 MAP Study) before crafting a detailed research plan. Regional potential for these measures was calculated; is roughly estimated to be a minimum of 20 aMW (Open Research Strategy for Walkthrough) 43

RTF Decision - 1 “I __________ move the RTF approve the following Manufactured Home measure analysis and Research Strategy: – Heat Pump Conversions – Heat Pump Upgrades – Commissioning Controls & Sizing (CC&S) – Performance Based Duct sealing and: Set the Category for measures to ‘Planning’; Set the Status to ‘Active’; Set the sunset date to August 31, 2018” 44

RTF Decision - 2 “I __________ move the RTF approve the MH HP Related Measures Research Strategy for following Manufactured Home With Heat Pump Weatherization measures: – Attic Insulation Upgrades – Floor Insulation Upgrades – Infiltration Reduction – Window Upgrades and: Keep the Category for measures to ‘Planning’; Change the Status to ‘Active’; Set the sunset date to August 31, 2018” Note: Planning savings estimates set equal to the Electric Resistance Weatherization approved savings, as per RTF June Decision 45