Relay Controller Device. 2 Relay Controller Device (RCD) If additional relays are needed beyond the two that are available on the DCD, then a RCD can.

Slides:



Advertisements
Similar presentations
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface VIA ROMA, 20 - I CREAZZO (VI) ITALY PHONE
Advertisements

UNIT 31 HOME ELECTRICAL SYSTEM
KV / kV2 Meter RSX Option Board (RS-485 mode) Connections Notes: 1) TP1-1 = Twisted Pair set #1, wire #1 2) TP1-2 = Twisted Pair set #1, wire #2 3) TP2-1.
Basic Jens Neigaard.
NetSure™ RDB Series.
GS3055-I GSM Universal Wireless Alarm Communicator
Trouble - Shooting ELR - Electric Latch Retraction.
PXL-500/-510 Tiger Controller II
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
Training.
CR1000s are only one part of a data acquisition system. To get good data, suitable sensors and a reliable data retrieval method are required. A failure.
Dealer Certification Section 2: Building the Network Physical Planning & Documentation Power Sources & Distribution Voltage Drop Calculations Copyright.
Electrical Workshop Session One 9/22/2014. FIRST Power Distribution Diagram.
INTRUSION ALARM TECHNOLOGY
The SCSI Interface Objectives In this chapter, you will: -Understand the different SCSI standards and confusing naming schemes -Identify cables and connectors.
A Team 378 Tutorial Basic Wiring. Wire Wire Gauge should be determined by the item being powered. The fuse size for that circuit should correlate to the.
ET3100 BioFlex TimeClock. What is fingerprint scanning?  It is a pattern acquisition and recognition established on a person’s.
Solar Energy Station Directions. Making a Solar-Powered Circuit 1.Make sure your solar panel is in direct sun. 2.Get the clear LED bulb. 3.Use a red jumper.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Information Technology Lecture No 3 By: Khurram Shahid.
Presentation of the DriveLab Board Opal-RT Real-time institute 2009.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
GS3055-I GSM Universal Wireless Alarm Communicator
First, let’s review the structure and use of a breadboard.
Intelligent Control Panel SLC
LSU 09/19/2013BalloonSat Development Board1 The BalloonSat Development Board Programming Unit, Lecture 1.
PC Maintenance & Networking Material Developed Under DST – NIMAT Project (TEDP) By VidyaDeep Foundation, Satara.
January 14, 2006Company Confidential NAUTILUS ETHERNET IFS # Rev. A.
Dupline Hi-Line Irrigation Control Jens Neigaard1.
FEE Electronics progress PCB layout 18th March 2009.
Unit 7 PC SYSTEMS Unit 7: PC Systems Unit type: Certificate and Diploma Learning hours: 60 hours Unit level: 1.
Door Controller Device. 2 Door Controller Device (DCD) The DCD is the “Remote Brains” of the system. It is the controller device located at each access.
Power Supply. 2 Power Supply w/Line Conditioner The power supply is the heart of the Millenium System. It can support between 15 DCD boards (power for.
Test Tube Activities at Ohio State (7/29/03) Amphenol/Spectra Strip will send two 10 m long samples of signal cable –With a (round) jacket, shielding –20.
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
Duct Free System.
NEW RMC Rack Multi Control.
Starting System Circuit Operation and Testing
GPRS Troubleshooting.
Elevator Control Unit.
Grounding.
Site Controller Unit and Trunk Interface Unit
D Sequencer – Insertable
ABSTRACT The controller continuously polls the temperature with certain regular time intervals and displays over the 7_segment display The temperature.
Block Diagram Transmitter Receiver × 2 Transmitter Power Supply ADC
SUBMITTED BY EDGEFX TEAM
Elevator Controller Device
LDA Large Display for Analog Inputs
NSA-7000 Stylish flush mount Network Sensors
Product Training Module
NI Data Acquisition (DAQ) Wiring and Connections
PLC Hardware Components.
Peripheral Devices
Module 1 – Power Supply AMC APS-PBC-60
FEE Electronics progress
Five Key Computer Components
Energy wise 2012 The new beginning Mike Dietz,
Subject Name: Microwave and Radar Subject Code: 10EC54
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Integrated gateway-server
Computing Essentials Module 1.
Computing Essentials Module 1.
724 Temperature Calibrator
DeviceNet Communication Solution for Discrete Devices
Memory Addresses.
Honeywell Fire Systems Group RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks.
Presentation transcript:

Relay Controller Device

2 Relay Controller Device (RCD) If additional relays are needed beyond the two that are available on the DCD, then a RCD can be employed. Each RCD has eight Form “C” relays on-board. The relays are configured using the software and have a variety of means of operation. The Millenium Windows System can support up to ten RCD’s per SCU for a total of 80,000 relays per system.

3 RCD Spec’s Voltage: 9 to 14 VDC (RCD will not operate below 9 volts) Current: 200 ma (worst case current draw, board only) Data Storage: 24hr minimum clock and memory backup. Output: 8 Form “C” relays, rated at 24 2 amps. –Relay 0 on the RCD addressed as Device 0 is hard coded as a network communications failure output. Tamper: Independent signal for cover tamper. Operational Temperature: 14  F to 104  F (-10  C to 40  C).

4 Addressing the RCD

5 RCD J1 Terminal Block Connections

6 RCD J2 Programming Connector

7 RCD J3 Jumper

8 RCD J4 Jumper

9 RCD J5 Terminal Block Connections

10 RCD J6 Terminal Block Connections

11 RCD Firmware Revisions

12 Deleting Programmed Data on the RCD

13 RCD Watchdog LED

14 RCD Trunk Communications

15 RCD Data Wiring

16 RCD Input Power

17 RCD Power and Data Wiring

18 RCD Relay Outputs

19 RCD Tech Notes The inbound data trunk cable and the power cable should have some form of identification like a piece of electrical tape around the jacket to ensure that future trouble shooters know which direction the power and data source is feeding from. The inbound and outbound shield of the trunk data cable, should be twisted together and fastened with an electrical crimp or wire nut. The shield should not connect to any terminals of the RCD PCB. The first RCD on the network branch must have an address of “0”.

20 RCD Tech Notes Inbound and outbound data trunk connections should be made on terminals 1 and 2 (respective of polarity) on the J1 connector. Since the 12 AWG power cable is difficult to install under the terminals of the RCD, it is recommended that the inbound and outbound cables be combined with an 18 AWG pigtail which is wired to terminals 1 and 3 of the J6 connector. The first relay on the board address as “0” is hard coded as a communications supervisory output and cannot be reprogrammed. RCD’s are not sold with an enclosure, make you order them.

21 RCD Terminal Summary Label