Testo 350 Analyzer Tour The New Generation Emissions Analyzer System Complete Simplicity Extreme Versatility Absolute Expandability The New Generation.

Slides:



Advertisements
Similar presentations
THE DEVICE, THE FEATURES & Centralized Management System (CMS)
Advertisements

ACTIVE LEARNING PROCESS
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Total HVAC Control from anywhere Easy control that can save a fortune
Items from Pricelist Accessories, Additional Options, Meteorology and Tools.
Manual Set-Up for Density by Hydrometer Method ASTM D1298, D287, D6822 and IP160 Feb
Introducing the Mobile Sink with Cabinet Base and Self Contained Water Supply BH, Inc.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
11 Heating System Operation and Diagnosis.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
EZ-3 ECG. Thank you for your interest in Futuremed’s EZ-3 ECG. Like other EZ-3 users, we are confident you will enjoy this model ideal for obtaining sharp.
Settings & Adjustments. Settings & Adjustments.
High Sensitivity Smoke Detection
Integrated Probe Storage Easy to Read LCD Display Bright LED Indicator Light Simple 4 Arrow Navigation with Enter Key (Circle) By the Numbers: Food.
NAVIGATOR™ Portable Balances
Mercury Spill Response Instrumentation. Mercury Vapor Analyzers Jerome 431-X MVA (gold film) Lumex 915+ MVA (Atomic Absorption) Jerome J405 MVA.
2.00 Understand Computer Fundamentals. Unit Objective: 2.02.
2.00 Understand Computer Fundamentals. Unit Objective: 2.02.
© CCI Learning Solutions Inc. 1 Lesson 5: Basic Troubleshooting Techniques Computer performance Care of the computer Working with hardware Basic maintenance.
© 2007 Multigas Detector Reliability in a small package.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
Manual Density Business Today
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
World Leaders in Combustion Management Solutions New Product Developments Autoflame Sales Meeting 2011 New Product Developments.
Digital Literacy: Computer Basics
PRESENTATION. Parts of the PCOS (3) Operator LCD Screen with Counter (4) Printer Compartment (5) Transmission Port (9) “RETURN” Button (8) “CAST” Button.
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
Air-cooled Modular Chiller Installation
New Electric Actuators EA Type
Quick Start Guide for Flex Flow Pump
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
Computer Information Systems
Avaya VA Line-interactive UPS
Managing Windows Devices
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
IN SAMPLE PUMP INNOVATION
Automotive Heating And Air Conditioning
LECTURE Course Name: Computer Application
K TO 12 CHS MODULE FOR GRADE 9, PP
Unit 3 – Fundamentals of Electronics Examination Specifications
Application Operation principle Advantages Highlights Comparison
Student CD for Commercial Refrigeration for A/C Technicians Chapter 12 Ice Machines.
T-6B On-Board Oxygen Generation System (OBOGS)
SB Packing Automatic Downpuller Power Unit
August 23, 2000 R.N. Dubois Dow Chemical
ANALYSERS & INSTRUMENTS DEPT. OPASTOP GP2001H
G450 and G460 battery pack maintenance
IN SAMPLE PUMP INNOVATION
AQT90 FLEX – the product 28/11/2018.
Administration Training
NEW COMPLIANCE REGULATIONS
Multiparameter Display System
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Total HVAC Control from anywhere Easy control that can save a fortune
F Aero Diffusion Technical Specifications ArtyScent®
Universal Interrupted Electronic Oil Primary R7184U Training Module
Piccolo Xpress™ Moderately Complex Training Demonstration
PowerLogic™ offer for the basic metering market
F Aero Diffusion Technical Specifications IconoScent®
724 Temperature Calibrator
Total Solution for Flue Gas Analyzer Series
Automobile Emission Gas Analysis Solution
Dräger X-am 5000 / X-am 5600 VIDEO BASIC TRAINING
T-6B On-Board Oxygen Generation System (OBOGS)
Effects of Cold on Military Vehicles
Presentation transcript:

Testo 350 Analyzer Tour The New Generation Emissions Analyzer System Complete Simplicity Extreme Versatility Absolute Expandability The New Generation Emissions Analyzer System Complete Simplicity Extreme Versatility Absolute Expandability

Modular System Control Unit Control Unit Analyzer Box Analyzer Box Probes

Fast wire for control and readout Advantages of fast wire technology Readings are near controls Fast sample response Accurate sample analysis Complete control remotely

Control Unit Integrated printer Analyzer Box NiMh Batteries Quick Change Particulate Filters Quick Change Particulate Filters User Defined Probe Inputs User Defined Probe Inputs User-defined Function keys User-defined Function keys RS 232 Data Communication RS 232 Data Communication Integrated  Pressure Integrated  Pressure Integrated Peltier Gas Conditioner Integrated Peltier Gas Conditioner Integrated Pressure & Flow Measurement Integrated Pressure & Flow Measurement Data Bus Sample Probes Aux. Probes Sample Probes Aux. Probes Testo 350 M/XL

Control Unit Integrated printer Analyzer Box NiMh Batteries Quick Change Particulate Filters Quick Change Particulate Filters User Defined Probe Inputs User Defined Probe Inputs User-defined Function keys User-defined Function keys RS 232 Data Communication RS 232 Data Communication Integrated  Pressure Integrated  Pressure Integrated Peltier Gas Conditioner Integrated Peltier Gas Conditioner Integrated Pressure & Flow Measurement Integrated Pressure & Flow Measurement Data Bus Sample Probes Aux. Probes Sample Probes Aux. Probes Testo 350 M/XL

Control Unit M/XL Controls analyzer box Displays all flue gas measurements Logs data Prints data Can measure  pressure/flow with optional Pitot tubes Can operate remote from the analyzer box (6’, 16’, 65’, 150’ and much more) Controls analyzer box Displays all flue gas measurements Logs data Prints data Can measure  pressure/flow with optional Pitot tubes Can operate remote from the analyzer box (6’, 16’, 65’, 150’ and much more)

Touch screen pen Touch screen pen Printer Back light screen Back light screen Function button Menu button Escape button Escape button On/off button Selection buttons Light Switch Testo 454/Control Unit.. 2 – Pressure Sensors 2 – Pressure Sensors Communications Ports (2) for auxiliary probes such as humidity Communications Ports (2) for auxiliary probes such as humidity

Cable must be connected When control unit is removed from docking position, cable must be attached

Press the tab on the left to release the hand held controller from the analyzer box Hand held controller locks to the analyzer box

On / Off 1.In the main measurement display - switch the display pages 2. Menu selection 3. Dialog figure / character input 1.In the main measurement display - switch the display pages 2. Menu selection 3. Dialog figure / character input 1.In the main measurement display - switch the operational bar 2. Dialogue figure / character input 1.In the main measurement display - DIsplay the other menus 2.In the sub-menu - store changes and go directly back (short cut) to the measurement display 1.Escape / Back 2.Reject changes Display illumination 1.In the measurement display - Selection of the system configuration 2. Confirmation / selection of the input + + Configuration of the function keys Control Unit - Button Layout Water-proof Dust-proof Keypad Water-proof Dust-proof Keypad

Display 6 parameters per page 6 pages of information Display 6 parameters per page 6 pages of information Parameter and Unit of measure User defined functions Control Unit testo 350 / 454 Display Fault indication & Program status Fault indication & Program status Pump indicator O Measurement Location Name Device ID # Display Page Number Instrument Status Function Menu

Easy entry touch-pad screen Simple data management Quick alphanumeric input Set-up as computer keyboard Simple data management Quick alphanumeric input Set-up as computer keyboard

Simple touch screen pen storage

Integrated printer Easy and convenient documentation Customized print-out display Easy to replace paper Easy and convenient documentation Customized print-out display Easy to replace paper

Control Unit Power Rechargeable batteries with 8 hour charge Alkaline batteries backup AC Power Adapter Rechargeable batteries with 8 hour charge Alkaline batteries backup AC Power Adapter Strong magnets

Standard Sample Probes Protected Thermocouple Reads Gas Temperature Threaded Cone Secures Probe Heat Shield Double wall Sample Tube Patented Unheated Sample Line Thermocouple line

Sample Probes Lengths from 12” to 9’ Temperatures from 1000° F to 3200° F Heated or Ambient Lengths from 12” to 9’ Temperatures from 1000° F to 3200° F Heated or Ambient

Improves analyzer response rate (sample residence time <1.4 seconds) Low reactivity to NO 2 / SO 2 (teflon construction) Battery operation is possible (heated hose  requires AC power) Inexpensive – (especially compared to heated sample lines) Light weight - ideal for portable analyzers. Self-cleaning (scrubs particles) Lengths of up to 16 ft Testo’s Patented Unheated Sample System

Rubber hose PTFE (Teflon) hose From Probe To Analyzer Max. length 16 ft.  : 2mm High flow rate: ft/sec Sample time Probe to analyzer <1.4 seconds Sample absorption: < 0.3% Sample line construction Testo’s patented sample line H20 droplet

Teflon hose 2mm, non-heated NO2 measurement Test gas: 100 pmm NO2 SO2 measurement Test gas: 1000 pmm SO2 Comparison of non-heated 2mm Teflon hose and teflon lined heated hose Teflon lined heated hose Teflon hose 2mm, non-heated Teflon lined heated hose

Testo’s Heated Sample Lines Sample line lengths of 30’, 60’ and custom Heated sample lines are available for testing at temperatures below 15º F. Heated sample lines for 110 and 220 VAC

Performs gas analysis Sample conditioning Performs gas analysis Sample conditioning The Analyzer Box Self- contained for long term testing

Modular design for easy set-up The analyzer box includes, sensors, pumps, batteries, electronics and all necessary hardware for flue gas measurements

Powering Up Attaching power cable –AC 110 to 240 volts Hz –DC 2-3 hours of battery charge –DC 12 V adapter optionally available Attaching power cable –AC 110 to 240 volts Hz –DC 2-3 hours of battery charge –DC 12 V adapter optionally available

Attach Probe and Hose Simple rugged integrated probe attachment Attach probe/hose plug (only fits one way) Plug in thermocouple to adjacent socket (keyed) Attach probe/hose plug (only fits one way) Plug in thermocouple to adjacent socket (keyed)

The Thermocouple Plug Keyed plug only fits one direction

Properly Attached Probe and Thermocouple

Temperature probe attachment For continuous measurement of flue gas, and ambient air temperature (standard equipment) Ambient probe is factory installed For continuous measurement of flue gas, and ambient air temperature (standard equipment) Ambient probe is factory installed Identical input for thermocouple probe interchangeability Type K TC Identical input for thermocouple probe interchangeability Type K TC

Ambient temperature probe Ambient temperature probe installed Does not need to be removed Ambient temperature probe installed Does not need to be removed

Data bus Connections Data bus connections allow communications to Handheld Controllers, Computers, and other analyzers Data bus connections allow communications to Handheld Controllers, Computers, and other analyzers

Simple 2 x Network Measurements made in two places quickly and easily compares “before & after” results

Analyzer Networking

Control Unit Box Connections Proper cable connection uses either port Different lengths 6’, 16’, 65’, 150’ and more Proper cable connection uses either port Different lengths 6’, 16’, 65’, 150’ and more

Particulate filters Obvious filters make checking easy Simple visual inspection confirms status Get dirty from the inside to outside Quick-lock housing allows rapid change All filter elements are interchangable Obvious filters make checking easy Simple visual inspection confirms status Get dirty from the inside to outside Quick-lock housing allows rapid change All filter elements are interchangable

Fast & Easy Quick Change filters No tools required

Exhaust Outlets & Inlets CO Flue Gas Outlet Fresh Air / Zero Air Purge Inlet Main gas outlet CO Flue Gas Outlet Fresh Air / Zero Air Purge Inlet Main gas outlet

Condensate trap Reservoir for flue gas condensate Three positions to test

Water removal Remove cap to drain water, or Install tube over nipple for water drain Do not use past MAX line Remove cap to drain water, or Install tube over nipple for water drain Do not use past MAX line

Condensate removal pump Long-life peristaltic pump Quick removal for easy maintenance Long-life peristaltic pump Quick removal for easy maintenance Remove two screws for easy access

Analyzer Box Description Each analyzer has complete equipment information listed on the bottom

Sensor Identification Sensor cover has sensor information inside!

Hot Moist Sample Gas In Pelitier Chiller Condenses H2O Peristaltic Pump Removes H2O Moisture Trap Captures H2O H2O Out Filter Cleans Dry Gas Pump Draws Sample In Sample passes Over Sensor NOT Through Laser welded non-reactive gas path circuit board TESTO 350 GAS PATH SCHEMATIC

Sensors and battery pack Quick Access - no tools needed

Testo Electrochemical Sensors Most accurate Least time consuming Less expensive Lowest cost of ownership Most accurate Least time consuming Less expensive Lowest cost of ownership Fastest responding Sensor Personality card Regulated Heater

Extreme Versatility Simple sensor swap-out Pre calibrated sensors Cal gas Not needed Simple sensor swap-out Pre calibrated sensors Cal gas Not needed

Sensor Identification Sensors are: Labeled Color- coded And….. Sensors are: Labeled Color- coded And…..

Extreme testing Range Space for 6 sensors Swap out sensors for other choices Swap out sensors for a different ranges Space for 6 sensors Swap out sensors for other choices Swap out sensors for a different ranges CO low CO high NO low NO high O 2 SO 2 H 2 S C x H y

Gas Sensor Selection O2 = % CO = 0 – 500 PPM CO = 0-10,000 (Dilution system to 400,000PPM) NO = 0 – 300 PPM NO = 0 – 3,000 PPM NO2 = PPM SO2 = 0 – 5,000 H2S = 0 – 300 PPM CxHy = 0 – 20,000

Sensor Exchange Only tools required

Automatic Sensor heating Protect sensors from condensation & freezing Automatic Sensor heating Protect sensors from condensation & freezing Temperature Controlled Sensors Extended low temperature range Accurate down to 20 ’ F Quick response on cold days Extended low temperature range Accurate down to 20 ’ F Quick response on cold days

Complete Simplicity Extreme Versatility Absolute Expandability Expand Your Testing Horizons Now! Complete Simplicity Extreme Versatility Absolute Expandability Expand Your Testing Horizons Now!

Extreme Versatility

Testo 350 Testo 350 Absolute Expandability Expand Your Testing Horizons Expand Your Testing Horizons