Hall C Compton Polarimeter: A new Compton for JLab Jeff Martin University of Winnipeg for the Hall C Compton collaboration U. Conn., Hampton U., JLab,

Slides:



Advertisements
Similar presentations
Hall A Collaboration Meeting S. Nanda, June 23, 2005 Hall A Compton Polarimeter For Hall A Collaboration Meeting June 23 rd 2005 Sirish Nanda Thomas Jefferson.
Advertisements

Fast and Precise Beam Energy Measurement at the International Linear Collider Michele Viti.
Compton polarimetry for EIC Jefferson Lab Compton Polarimeters.
1 Electron Beam Polarimetry for EIC/eRHIC W. Lorenzon (Michigan) Introduction Polarimetry at HERA Lessons learned from HERA Polarimetry at EIC.
Electron Detector for the Hall C Compton Polarimeter J.W. Martin & D. Dutta U. Winnipeg & Mississippi State U.
Pulse Shape Analysis with Segmented Germanium Detector Xiang Liu, Max-Planck-Institut für Physik 1.Motivation 2.Pulse properties 3.Analysis procedure 4.Some.
Compton Polarimeter for Qweak Evaluation of a Fiber Laser reference laser high-power fiber laser comparison S. Kowalski, M.I.T. (chair) D. Gaskell, Jefferson.
Tagger Electronics Part 1: tagger focal plane microscope Part 2: tagger fixed array Part 3: trigger and digitization Richard Jones, University of Connecticut.
Stanford – Mar , 2005 LCWS-2005 Norbert Meyners Upstream Polarimetry with 4-Magnet Chicane 1 Introduction & Overview O Compton polarimetry basics.
NLC - The Next Linear Collider Project  IR background issues and plans for Snowmass Jeff Gronberg/LLNL Linear Collider Workshop October 25, 2000.
Hall C Compton Polarimeter Preliminary Design by the Qweak Polarimetry Working Group S. Kowalski, M.I.T. (chair) D. Gaskell, Jefferson Lab R.T. Jones,
The Tagger Microscope Richard Jones, University of Connecticut Hall D Tagger - Photon Beamline ReviewJan , 2005, Newport News presented by GlueX.
K. Moffeit 6 Jan 2005 WORKSHOP Machine-Detector Interface at the International Linear Collider SLAC January 6-8, 2005 Polarimetry at the ILC Design issues.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
ALPHA Storage Ring Indiana University Xiaoying Pang.
PAIR SPECTROMETER DEVELOPMENT IN HALL D PAWEL AMBROZEWICZ NC A&T OUTLINE : PS Goals PS Goals PrimEx Experience PrimEx Experience Design Details Design.
1 Semiconductor Detectors  It may be that when this class is taught 10 years on, we may only study semiconductor detectors  In general, silicon provides.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
Status of the Beamline Simulation A.Somov Jefferson Lab Collaboration Meeting, May 11, 2010.
IPBSM status and plan ATF project meeting M.Oroku.
Diana Parno – July 22, 2008 January PREx Test Run: Compton Photon Analysis Diana Parno Carnegie Mellon University HAPPEX Collaboration Meeting.
22 December 20143rd FCAL Hardware WG Meeting 1 BeamCal sensors overview Sergej Schuwalow, DESY Hamburg.
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
A study of systematic uncertainties of Compton e-detector at JLab, Hall C and its cross calibration against Moller polarimeter APS April Meeting 2014 Amrendra.
COMPTON POLARIMETRY Collected data Cavity power Status on counting methods Systematic errors and hardware issues.
CVD diamond detector as a beam monitor for a high intensity and high luminosity accelerator Kodai Matsuoka (Kyoto Univ.) for T2K muon monitor group.
Radius To use a Compton polarimeter, the possible range of the backscattered photons’ energy should be calculated. Applying the laws of conservation of.
Photodetection EDIT Internal photoelectric effect in Si Band gap (T=300K) = 1.12 eV (~1100 nm) More than 1 photoelectron can be created by light in silicon.
Compton polarimetry for EIC Jefferson Lab Compton Polarimeters.
1 The Longitudinal Polarimeter at HERA Electron Polarization at HERA Laser System & Calorimeter Statistical and Systematic Precision Laser Cavity Project.
Electron Detection for Compton Polarimetry Michael McDonald Outline -Compton Effect -Polarimetry -Detectors -Diamond Results.
1 Overview of Polarimetry Outline of Talk Polarized Physics Machine-Detector Interface Issues Upstream Polarimeter Downstream Polarimeter Ken Moffeit,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
EIC Compton detector update October 24 th 2014 Alexandre Camsonne.
Summary of Workshop on Precision Electron Beam Polarimetry Newport News June 9-10, 2003 workshop summary by Dave Gaskell, Jefferson Lab Richard Jones,
» RHIC Polarimetry « Oleg Eyser for the RHIC Polarimetry Group 2014 RHIC Retreat, August 14.
External Seeding Approaches: S2E studies for LCLS-II Gregg Penn, LBNL CBP Erik Hemsing, SLAC August 7, 2014.
Compton polarimetry for EIC. Outline Polarized electron beam Compton process Compton polarimeters at Jefferson Laboratory – Parity experiments at Jlab.
PAC07, Albuquerque, NM, June25-29, 2007 Fiber-Based Drive Laser Gain-switched seed ErYb-doped fiber amplifier Frequency-doubler 1560nm 780nm.
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
A Prototype Diamond Detector for the Compton Polarimeter in Jefferson lab, Hall C Medium Energy Physics Group Amrendra.
PREX Issues. Outline New issue: souce systematics and Aug. 07 run. Update on old issues. Progress at SU.
1 A Proposal for Compton Electron Detector R&D Stephan Aune 9, Alexandre Camsonne 1*, Wouter Deconinck 8, Dipankgar Dutta 4, Gregg B. Franklin 7, David.
Taikan SUEHARA et al., LCWS2007 & DESY, 2007/06/01 R&D Status of ATF2 IP Beam Size Monitor (Shintake Monitor) Taikan SUEHARA, H.Yoda, M.Oroku,
Compton electron detector R&D. Compton polarimetry Compton electron Compton photon.
Hall C Compton Polarimeter Working Group Meeting Jefferson Lab August 8, Meeting agenda 2.Compton Polarimeter overview 3.Subsystem status.
Page 1 Polarized Electron Sources for Linear Colliders October, 2010 A. Brachmann, J. C. Sheppard, F. Zhou SLAC SLAC October 18-22, 2010.
Beam Profile Monitor for Spot-Scanning System Yoshimasa YUASA.
Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy The Department.
A Diamond Micro-strip Electron Detector for Compton Polarimetry Amrendra Narayan Mississippi State University on behalf of Hall – C Compton Team.
Compton Electrons Jeff Martin University of Winnipeg.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
Manoj B. Jadhav Supervisor Prof. Raghava Varma I.I.T. Bombay PANDA Collaboration Meeting, PARIS – September 11, 2012.
Pb-Parity and Septum Update Presented by: Luis Mercado UMass - Amherst 12/05/2008 Thanks to Robert Michaels, Kent Pachke, Krishna Kumar, Dustin McNulty.
Status of Polarimeters and Polarized Targets: what are the plans for development of polarized targets to meet the needs of the Day 1 and future experimental.
Focal Plane Scanner Jie Pan * + for the scanner working group Laura Cobus*, Anna Micherdzinska* Jeff Martin*, Peiqing Wang + * University of Winnipeg /
Compton Polarimeter Electron Detector Jeff Martin University of Winnipeg (for Dipangkar Dutta at MSState and for the Canadian group) Outline ● Overview/Funding/Project.
Compton Polarimeter Electron Detector Jeff Martin University of Winnipeg (for Dipangkar Dutta and the Canadian group) Outline ● Overview/Funding/Project.
Diamond – Tungsten Calorimeter LCAL-group : K. Afanasiev, V. Drugakov, E. Kouznetsova, W. Lohmann, A. Stahl Workshop on Forward Calorimetry and Luminosity.
Seeding in the presence of microbunching
Analysis of 14/20 mrad Extraction Line Energy Chicane
Panagiotis Kokkas Univ. of Ioannina
Detection of muons at 150 GeV/c with a CMS Preshower Prototype
大強度
Polarized Positrons at Jefferson Lab
Special Considerations for SIDIS
Kazuya Aoki For the PHENIX Collaborations. Kyoto Univ. / RIKEN
Hall C Beamline Upgrade
Semiconductor Detectors
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

Hall C Compton Polarimeter: A new Compton for JLab Jeff Martin University of Winnipeg for the Hall C Compton collaboration U. Conn., Hampton U., JLab, U. Manitoba, MIT, Mississippi St. U., TRIUMF, UNBC, UVa, U. Winnipeg, Yerevan EIC Electron Polarimetry Workshop University of Michigan, August 23-24, 2007 Outline ● Project Overview ● Progress in Design and Prototyping ➢ focusing on laser, and on electron detector ● Monte Carlo ● Some comments for EIC

Motivation for Compton Polarimetry for Hall C ● Continuous, noninvasive measurement of polarization ● Complementary to Moller (which is periodic, invasive) ● Systematic uncertainty to be similar to Moller (<1%) – required for high-precision experiments, e.g. Qweak.

Design Goals ● (P/P) statistical < 1% per hour – high laser power – high laser energy (green) increases Compton asym. – large acceptance for detectors (in energy) ● (P/P) systematic < 1% – stable beam, small spot in interaction region – low backgrounds – good energy resolution in detectors – high laser energy increases Compton edge

Design Goals Cont'd ● Operable for a variety of beam energies from GeV – 11.0 GeV – chicane – must fit in Hall C Most design studies currently focused on achieving 1% for Qweak experiment: uA

Hall C Compton Overview ● Laser ● Chicane ● Detectors beam into expt.

Some Design Parameters at GeV ParameterSymbol Value Beam EnergyE beam GeV Laser wavelength 532 nm Photon Compton edgek' max 46.4 MeV Max. asymmetryA max Chicane bend angle bend 10 deg Electron free drift distanced drift 3.3 m Electron displacement atX max 23 mm Compton edge major design goal at low beam energy is to maximize Compton edge

Laser Options Considered for Hall C laser P E max rate t (1%) option (nm) (W)(MeV)(KHz) (%)(min) Hall A UV ArF UV KrF Ar-Ion (IC) DPSS Fiber laser Fiber laser (counting mode) Energy-weighted asymmetry based on this, and on other factors, we have selected the “Fiber laser” solution

Electron Beam I t I t I t I t In-Cavity operation like Hall A most high- power pulsed green lasers JLab beam structure fiber laser for Hall C Despite lower average power, fiber laser would achieve higher luminosity than higher power pulsed green lasers on the market. Other advantages: - lower instantaneous rates for counting Laser Beam

Fiber Laser Advantages ● External to beamline vacuum (unlike Hall A cavity) – easy access ● Pulse at JLab microstructure rate (499 MHz) – huge luminosity boost when phase locked! ● In-house expertise – M. Poelker and JLab source group demonstrated few Watts operation at 780 nm for CEBAF source. – excellent stability, low maintenance, straightforward implementation – almost ideal optical properties M 2 = 1.33

“CEBAF's Last Laser” - demonstrated at polarized source Gain-switched seed ErYb-doped fiber amplifier Frequency-doubler 1560nm 780nm

Fiber Laser for Hall C Compton ● Seed 1064 nm ● Fiber amplifier (50 W output at 1064 nm) ● Frequency doubling cavity ● Result: 25 W, 532 nm, 30 ps pulses at 499 MHz ● In-house expertise helps us even more – Polarized source group is willing to build our laser (with help from Shukui Zhang from FEL for the frequency doubling) – New ideas: low gain cavity x

We need more than a laser ● Optics table design – e.g. Need to know P circ = 100% ● Potential x2 gain in power if mirrors internal to beamline can be implemented. a possible interaction region layout

Chicane ● Optics design exists ● Physical layout underway (fit in Hall C) ● Dipole design underway beam into expt.

Chicane will be reconfigured for 12 GeV upgrade ● interplay of chicane parameters with electron displacement at Compton edge ● Photon/electron detectors probably look different at 12 GeV than at GeV

● Photon Detector – 3x3 array of PbWO 4 – working prototype – calibration and testing underway – different from Hall A plan for low beam energy Detectors ● Electron Detector (what I'll mainly focus on) – diamond strip tracker – monolithic diamond prototyping nearly complete – prototyping of strips on diamond underway

● Position resolution gives momentum of scattered electron. – Independent single-arm measurement of polarization – Calibration of photon detector (coincidence mode) ● Designing for 1% Polarization Determination for BOTH Motivation for Electron Detector Monte Carlo simulation from D. Storey, U. Wpg hons thesis beam direction

How a diamond detector works ● Signal limited by impurities and grain boundaries ● Increases with E-field up to ~1-2 V/  m ● CCD (“charge collection distance”) ~ 250  m

Why pc-CVD diamond? ~250fullCharge collection distance (micron) 3689Av. e-h pairs per MIP per micron 133.6e-h creation energy (eV) Displacement energy (eV) Dielectric Constant 2.2x10 7 3x10 5 Breakdown field (V/m) 2x x10 7 Saturation velocity (cm/s) 2200/ /500Electron/Hole mobility (cm 2 /Vs) Band Gap (eV) DiamondSilicon Low leakage current, shot noise Fast signal collection Low capacitance, noise Rad hardness Smaller signal from Wallny, UCLA Advantages: lower leakage current, faster, lower noise, more rad hard At the expense of: smaller signal

Radiation Hardness of Diamond Detectors CERN R&D: Performance after irradiation with protons Little change in S/N after exposure of ~5 Mrad 15% change in S/N after an exposure of ~50 Mrad Si 50% change in S/N after exposure of ~3 Mrad. Thanks R. Wallny (UCLA) Estimate for Qweak alone: 3 Mrad

Interlude How we make diamond detectors

1. Get a “CERN grade” diamond from ● Pictures below of Hall C prototypes (two exist): – 1 cm x 1 cm x 500 um – pc-CVD ( polycrystalline-chemical vapor deposition ) “large” side “small” side UM NSFL

2. Boil in various acids/bases. ● cleans off the surface ● attempt to replace H-terminated surface with O- terminated (oxidizing agents like H2O2) ● follow with low- power plasma etch in O2 environment Jeff Ania boiling HCl/HNO3/H2O2 small beaker = diamond large beaker = quartz holder glowing plasma thru etcher viewport Dwayne UM NSFL

strips on OSU 50 um pitch 3. Lay down some metal ● sputter or evaporate ● test detectors usually done with Cr (50 nm) / Au (200 nm) ● shadow mask used for “dots” ● photolithography (“lift-off”) used for strips. ● OSU procedure: dots, then strips, for every diamond. OSU sputter UM NSFL gold coated UM Sumitomo (test) diamond Element6 diamond sputter- coated penny

4. Test / mount in package Our Element6 OSU preamp out to scope ● Hall C will use four planes of 2 cm x 2 cm x 0.5 mm square pc-CVD diamond ● 100 strips per plane => 200 um strip pitch ● stagger the planes to achieve 100 um position resolution in bend plane of chicane RD42-owned diamond strip tracker with seven planes, 50 um strip pitch.

CCD Results for our prototype OSU ● Good results for our first dot! ● CCD “typical” ● Next steps: – replicate OSU dot process at UWpg, UManitoba (done) – design multistrip prototype (in progress)

Eventual Apparatus for Hall C ● Diamond Detector (4 planes, with 100 strips each) ● Electronics (preamp, discriminator, input module chain) to electronics chain

● D. Storey, U.Wpg honours thesis Monte Carlo Electron Detector Simulation Asymmetry vs strip number Polarization extracted by two methods: fit method integration above asymmetry zero Fit method susceptible to imperfect beam optics, nonlinearities in strip vs momentum. Integration method robust against such problems. For current Hall C design, complementary approaches give similar ultimate systematic uncertainty < 1%.

Summary/Timescale for Hall C Compton ● New Compton Polarimeter is under development for Hall C (EIC collaborators always welcome!!!) ● unique features compared to Hall A: – laser, chicane, electron detector ● Installation in Hall C for Qweak mid ● Commissioning early ● Reconfigure for 12 GeV, and pursue any upgrades, during long shutdown.

My own random thoughts and comments on EIC Compton Project (geared towards electron det.) ● Dual photon/electron detection critical for < 1% ● Current belief at JLab seems to be electron detector is more critical to achieve systematic uncertainty (consistent with SLAC?) ● basic kinematics consistent with Hall C at 11 GeV. – see next couple of slides ● You are welcome to a copy of our Geant3 Compton MC for more detailed questions.

Hall C Parameters at 11 GeV ParameterSymbol Value Beam EnergyE beam 11 GeV Laser wavelength 532 nm Photon Compton edgek' max 3.1 GeV Max. asymmetryA max 0.32 Chicane angle bend 2.3 deg Electron free drift distanced drift 3.3 m Electron displacement atX max 37 mm Compton edge still have to put the electron detector within ~ cm of the beam

Increase Bend Angle, Electron Drift Distance ParameterSymbol Value Beam EnergyE beam 11 GeV Laser wavelength 532 nm Photon Compton edgek' max 3.1 GeV Max. asymmetryA max 0.32 Chicane angle bend 5.2 deg Electron free drift distanced drift 10 m Electron displacement atX max 25 cm Compton edge ● constraints more consistent with SLD polarimeter (Compton edge at 18 cm) ● but electron detector would be much bigger. ● this is no longer a chicane.

Extras

from SLD Compton Pol site.

Cartoon of Hall C Beamline

Luminosity from Fiber Laser ● Average power from fiber laser modest (20 W)  does this equal factor of 5 reduction in luminosity compared to 100 W laser? ● No – we can actually get about a factor of 4 improvement – For laser pulsed at electron beam repetition rate (499 MHz) and comparable pulse width (on the order of ps), the luminosity is increased by a factor: ● For typical JLab parameters, this yields about a factor of 20 improvement in luminosity for  = 20 mrad

Luminosity from Fiber Laser Fiber laser pulse-width about 15 times larger than electron beam – no problem! 2.0 cm 2 1 cm 2  e =  laser = 100  m,  = 20 mrad Luminosity gain only weakly dependent on laser pulse width  for laser pulses ~ 10’s of ps

Electronics/DAQ Multi- strip detector Discrim- inator I/O module OR Pre- amp Fast- amp Requirements: 4*100 strips – for momentum analysis trigger: 3 out of 4 planes must fire (efficiency, background reduction) < 100 MHz rates expected from Compton Scattering + background High Amplification – small signal in diamond, ~ ½ silicon trigger similar rates for photon det, but need to additionally digitize pulse height waveform digitizer?