Implementing eMaintenance using i SCADA technology for Wisma Persekutuan Melaka By Nurhaizan JKR Mekanikal Melaka Case Study Published by permission and.

Slides:



Advertisements
Similar presentations
Yaniv Vardi, CEO Device Level Energy Management Technology.
Advertisements

and Trend for Smart Grid
What is a Good SmartSignal Model?
MCTS GUIDE TO MICROSOFT WINDOWS 7 Chapter 10 Performance Tuning.
ELECTRONIC LOAD CONTROL METER Installation and Programming.
Manufacturing Productivity Solutions Management Metrics for Lean Manufacturing Companies Total Productive Maintenance (T.P.M.) Overall Equipment Effectivity.
EXERGY Real-time Efficiency Analysis for Power Stations.
Optimizing Windows Vista Performance Lesson 10. Skills Matrix Technology SkillObjective DomainObjective # Introducing ReadyBoostTroubleshoot performance.
Telemetry system datavend.
This work is supported by the National Science Foundation under Grant Number DUE Any opinions, findings and conclusions or recommendations expressed.
Lesson 13-Intrusion Detection. Overview Define the types of Intrusion Detection Systems (IDS). Set up an IDS. Manage an IDS. Understand intrusion prevention.
Energy Management with the use of an Intelligent Building Management System.
Computer Security: Principles and Practice
Axis Intelligent Video Intelligence where you need it.
powered by. TARGET Provide with uninterrupted ATM services at the optimum cost, and lead to increased Customer satisfaction.
Data Acquisition for the Scientific community
Maintaining and Updating Windows Server 2008
Remote Monitoring. ShockWatch Cold Chain Solutions TrekView Multi-use recorder Performance Data Recorders Chemical Indicators ColdMark 2 WarmMark 2 Single.
Empowering Business in Real Time. © Copyright 2009, OSIsoft Inc. All rights Reserved. Data Center & IT Monitoring Use Cases Regional Seminar Series Carolyn.
EMBEDDED SOFTWARE Team victorious Team Victorious.
StorCast Enterprise Storage Resource Management. What is Enterprise Storage Resource Management?
EC4019PA Intrusion & Access Control Technology (IACT) Chapter 4- CAMS Prepared by Sandy Tay.
REMOTE SITE MANAGEMENT SOLUTION. AGENDA 2  About KoçSistem  Current Situation in Base Stations  Remote Site Management System: Sitelink  Sitelink.
Traffic Enforcement And Management System Malam-Team is Israel's largest systems integration organization, One of the most exciting solutions offered by.
Presented by Amira Ahmed El-Sharkawy Ibrahim.  There are six of eight turtle species in Ontario are listed as endangered, threatened or of special concern.
MCTS Guide to Microsoft Windows 7
DATABASE ADMINISTRATION WHAT IS IT?. THE GIST Database administrators are responsible for creating and maintaining the databases that form the core of.
Vantage Report 3.0 Product Sales Guide
Module 10: Monitoring ISA Server Overview Monitoring Overview Configuring Alerts Configuring Session Monitoring Configuring Logging Configuring.
Event Management & ITIL V3
The ProactiveWatch Monitoring Service. Are These Problems For You? Your business gets disrupted when your IT environment has issues Your employee and.
For 11kv substation network using technology Devices World Sdn Bhd.
© 2010 HM Cragg. All Rights Reserved Delivers a global view of power devices across the network from any PC with an Internet browser Delivers a.
Cctv Management Solution - CMS From – Intelitech Solutions Pvt. Limited. [ ITSPL Group ]
CONTENTS: 1.Abstract. 2.Objective. 3.Block diagram. 4.Methodology. 5.Advantages and Disadvantages. 6.Applications. 7.Conclusion.
Network management Network management refers to the activities, methods, procedures, and tools that pertain to the operation, administration, maintenance,
Presented by The Emerging Role of the PI System in Caterpillar’s Condition Monitoring Service David Krenek – Global Petroleum Market Professional.
CV works in the non- LHC accelerator complex during 2008 and plans for 2009 ATOP days 2009.
Migrating your Conventional Maintenance to eMaintenance using technology.
Run the on your PC to start the firmware configuration process Run IP Config Tool.
SCADA Supervisory Control And Data Acquisition Pantech Solutions Here is the key to learn more.
Manufacturing Productivity Solutions Management Metrics for Lean Manufacturing Companies Total Productive Maintenance (T.P.M.) Overall Equipment Effectivity.
I ntelligent Service Management System © Crown Equipment Pty Ltd 2015.
Vol.2 Introduction of System Products of Aleph Networks Co.  1)  SCOPE: Central monitoring system  2)  BEAMS: Energy management system  Aleph Networks.
SQL Database Management
PRESENTATION OF POSSIBILITIES OF THE IPS PRESSING UNIT CONTROL SYSTEM Inteligent Pressing System HYDRAULIC PISTON-CYLINDER PRESSING UNIT IPS is designed.
OPERATES SCADA OPERATION SYSTEM Explain the operational SCADA
Monitoring Windows Server 2012
Chapter 19: Network Management
Manufacturing Productivity Solutions
Connected Living Connected Living What to look for Architecture
SMS module HDL-MGSM.431.
MineDash 2.0 Using MineDash to Optimise your Operations Revision A
MCTS Guide to Microsoft Windows 7
How SCADA Systems Work?.
Connected Living Connected Living What to look for Architecture
Providing Big Data to facilitate Collaboration in a Safety Railway Environment Jens-Peter Brauner, VP Mobility Division, Siemens Ltd. Hong Kong 27th International.
Lec3: Network Management
"Uberize" Your Remote Equipment
Unit 10 NT1330 Client-Server Networking II Date: 8/16/2016
Module 1: System Overview
DATA COLLECTION, MANAGEMENT AND ANALYSIS
WHATAP 제가 와탭을 소개하겠습니다. November 14, 2018.
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
Presented by: John Antanies Principal and Founder
In-service Usage, Performance Monitoring & Management Service
AV 13 Avantis Capabilities for Effective Asset Management
Network Monitoring System
Lec1: Introduction to Network Management
Presentation transcript:

Implementing eMaintenance using i SCADA technology for Wisma Persekutuan Melaka By Nurhaizan JKR Mekanikal Melaka Case Study Published by permission and courtesy of JKR mekanikal Meleka.

Background The Fire Protection System in Wisma Persekutuan Melaka was upgraded in December 2003 At the same time, a Web-based SCADA ( i SCADA) system was installed to monitor the Fire Alarm, Hose Reel, Sprinkler, Chiller and Lift Systems. We implemented Electronic Maintenance (eMaintenance) to enhance our Maintenance Management process

Gateway Internet Server User 1.A Gateway collects failure events from our equipment and transmits them to a server on the Internet. 2.When a failure occurs, technicians automatically receive an SMS and 3.JKR and the FM contractor can access the data in real time from any PC How i SCADA works

Mobile Alerts Tel Line Internet i SCADA Server Embedded Internet Gateway Real-time Monitor / Alarm Online Reports / Statistics Embedded Internet Gateway Architecture Site 1 Site N

Monitor by System (Data from JKR melaka) See Status of ALL systems on the same screen See Status of ALL systems on the same screen Systems in good condition are in Yellow Folder Systems in good condition are in Yellow Folder Systems with Failure Events are in RED Folder Systems with Failure Events are in RED Folder Click on RED folder to see details of Failures Click on RED folder to see details of Failures

Monitor by Location (Data from JKR melaka) See Status of ALL sites/buildings at once See Status of ALL sites/buildings at once Buildings in good condition are in Yellow Folder Buildings in good condition are in Yellow Folder Buildings with Failure Events are in RED Folder Buildings with Failure Events are in RED Folder Click on RED folder to see details of Failures Click on RED folder to see details of Failures

Site 1 Melaka Site 2 Perak Site 3 Johor Internet iSCADA Server Global Reach Kawalselia

Real Time Monitoring screen shot showing that a Fault occurred in the Fire Alarm System on 26 May 2005 at 7:54 pm An and SMS was sent to Nurhaizan and Zulhelmi when the failure occurred

Reporting screen shot showing that the same fault kept repeating since 13 th May 2005

Statistics screen shot showing overall system availability from 1 st Jan 2004 to 31 st Dec 2004 Overall Functionality Index (Up Time) = 98.24% Fire Alarm Up Time was lowest at 88.3% Total Down Time of all systems = Hours

Transparency How JKR has benefited from implementation of eMaintenance Everything was recorded automatically without human intervention. Reports & statistics are available online to top management in real time. Efficiency Reduces manpower for fault detection and paper work Availability Automatic detection and SMS enables quick actions to be taken. This improves the overall availability of our systems.

Reporting Concept: eMaintenance Vs Conventional Maintenance Central Authority Lower Authorities Assets / Data Source Conventional Maintenance Central Authority Lower Authorities Assets / Data Source Query /Login Information Electronic Maintenance Reports Reports Reports

Reactive & Predictive Components of eMaintenance Reactive & Predictive Components of eMaintenance Reactive Maintenance: React to a system failure, and attempt to restore normal functionality in the shortest time possible. iSCADA’s role in Reactive Maintenance:- (1)Detecting Failures automatically, and sending alerts to technicians instantly and automatically by & SMS. (2)Logs all events and produces statistical analysis that can point to the root cause of problems (See next slide) Predictive Maintenance: Anticipate system failures before they happen by using Condition Monitoring tools iSCADA’s role in Predictive Maintenance:- (1) Monitoring analogue signals from the site in real time (2) Analyzing Trending data to detect abnormal behavior.

iSCADA helps point to root cause of failures iSCADA helps point to root cause of failures Due to Leaks in the Sprinkler System piping Screenshot of actual site data from JKR Melaka After the Fire Protection system at Wisma Persekutuan Melaka was upgraded, we used the iSCADA system to monitor the performance of the new installation. We found that there was over 500 events reported by the Sprinkler System. We drill deeper into the iSCADA statistical analysis report and it showed that the Jockey Pump ran for 443 times in a very short period of time, which is not normal. This indicated a leak in the piping system, which was subsequently fixed by the contractor.

iSCADA helps in Predictive Maintenance iSCADA helps in Predictive Maintenance Conditioning Monitoring allows maintenance engineers to detect abnormal behavior. Action can then be taken to prevent an actual failure. Eg 1. If a temperature sensor is embedded into the shaft of the Lift Motor, the temperature profile may indicate abnormalities in bearings or load. Eg 2. Taking periodic readings of peak current consumption of a compressor, and observing the trend over a period of time may point to deteriorating efficiency.

Moving Forward 1.Implement eMaintenance in all JKR buildings state-wide and nationwide 2.This allows consolidation of maintenance management data and central supervision 3.Performance of FM contractors can be monitored objectively with Key Performance Indicators (KPIs) 4.Ensure that Maintenance budgets are managed prudently 5.Enables JKR to perform Predictive Maintenance