RF Power Klystrons & 20 Year Look R. Nelson 7/15/15.

Slides:



Advertisements
Similar presentations
ESLS 04 Daresbury Laboratory
Advertisements

RF Specification discussion MICE RF workshop 16 th April 2012.
X Band Vacuum Devices Presented by: Tony Johns,
Andrew Moss ASTeC MICE Project Board 28 th June 2011 MICE RF System.
MICE Refurbishment of CERN RF equipment for MICE M. Vretenar, CERN AB/RF.
1 Operating Experience and Reliability Update on the 5 kW CW Klystrons at Jefferson Lab Richard Walker & Richard Nelson Jefferson Lab, Newport News VA.
09 th April 2003 SINGLE SPLIT DRIVE CHAIN TH116 TH116 or TH526 RS2058 ex SPS AMP 7651 ex RAL SOLID STATE DRIVER LEVEL CONTROL AND SOURCE R.F. LEVEL FEEDBACK.
Proton Source Workshop December 7 & 8, 2010 John Reid December 8, 2010.
Tom Kubicki.  Booster HLRF System to be upgraded using 1kW Solid State Driver (SSD) Amplifiers.  Used to drive the 200kW Power Amplifier  Eliminates.
DESIGN OF A HIGH POWER TEST STAND FOR ESS SPOKE CAVITIES
Thomas Jefferson National Accelerator Facility RF Power Systems / CWRF08 / March 27, JLab Update Rick Nelson.
Components & Subsystems New generations of RF Amplifiers : from system requirements to technologies Michel Caplot, Christian Robert, Michel Grezaud, Bernard.
Microwave semiconductor devices
Conventional Tubes Conventional Device tubes cannot be used for frequencies above 100MHz 1. Interelectrode capacitance 2. Lead Inductance effect 3. Transit.
News from HZB / BESSY Wolfgang Anders at ESLS-RF Meeting September 2010 Trieste.
RF Distribution Alternatives R.A.Yogi & FREIA group Uppsala University.
MEIC Collaboration Meeting, March 30-31, 2015 (Topics: Ion Beam Formation and Cooling) MEIC Collaboration Meeting, March 30-31, 2015 (Topics: Ion Beam.
Multiple Beam Klystrons for Accelerators and Collider
Andrew Moss ASTeC Collaboration meeting CM29 15 th - 18 th February 2011 MICE RF System.
R&D, Collaborations and Closeout Fulvia Pilat MEIC Collaboration Meeting March
February 17-18, 2010 R&D ERL Alex Zaltsman R&D ERL High Power RF Systems Alex Zaltsman February 17-18, 2010 High Power RF Systems.
Vacuum Electron Device Limitations for High-Power RF Sources Heinz Bohlen, Thomas Grant Microwave Power Products Division CPI, Palo Alto 1.
WORKSHOP SUMMARY. 2 Workshop summary CWRF08: finally we have: 54 ~10 33 talks Number of participants rose by almost 6dB.
PROTON LINAC FOR INDIAN SNS Vinod Bharadwaj, SLAC (reporting for the Indian SNS Design Team)
CLARA Gun Cavity Optimisation NVEC 05/06/2014 P. Goudket G. Burt, L. Cowie, J. McKenzie, B. Militsyn.
Linac RF Source Recommendations for Items 22,23,24,46,47 Chris Adolphsen.
Solid State RF High Power Amplifier Developments at SOLEIL Ti RUAN, on behalf of SOLEIL RF Group CWRF10 CELLS-ALBA Barcelona Spain May
Renovation of the 200 MHz RF system LLRF issues. Cavities redistribution 26 October th LIU-SPS Coordination Meeting 2  2011 : 4 cavities 2 x 4.
Design Optimization of MEIC Ion Linac & Pre-Booster B. Mustapha, Z. Conway, B. Erdelyi and P. Ostroumov ANL & NIU MEIC Collaboration Meeting JLab, October.
DTL Option for MEIC Ion Injection Jiquan Guo, Haipeng Wang Jlab 3/30/
Operational experience of high-power RF at Diamond Light Source
Ingot Niobium Workshop RF Sources Andrew Kimber 4 th December 2015 Thomas Jefferson National Accelerator Facility is managed by Jefferson Science Associates,
High power RF tests places at CERN O. Brunner, CERN 4th SPL Collaboration Meeting jointly with ESS.
ATC / ABOC 23 January 2008SESSION 6 / MTTR and Spare Parts AB / RF GROUP MTTR, SPARE PARTS AND STAND-BY POLICY FOR RF EQUIPMENTS C. Rossi on behalf of.
CW and High Average Power Workshop BNL The Diamond Storage Ring IOT based High Power Amplifier Morten Jensen on behalf of the SR RF Group.
An H- stripping laser using commercial, diode-pumped Nd:YAG amplifiers Russell Wilcox Laser Stripping Workshop, April 11, 2011.
ALBA RF Systems Francis Perez.
Booster High Power RF at PIP-II Era John Reid February 18, 2014.
High-efficiency L-band klystron development for the CLIC Drive Beam High-efficiency L-band klystron development for the CLIC Drive Beam CLIC workshop,
Linac RF System Design Options Y. Kang RAD/SNS/NScD/ORNL Project – X Collaboration Meeting April , 2011.
DESIGN STUDY November 28 th - 30 th 2005First EURISOL Design Study TOWN MEETING High Power RF Amplifiers Development at LNL Fabio Scarpa - INFN LNL.
In House RF Power Option John Reid December 14, 2011.
Prospects for developing new tubes
Development of high-power IOTs as an efficient alternative to klystrons Morten Jensen Energy for Sustainable Science 24 October 2013, CERN.
RF Sources and Combiners
Visit for more Learning Resources
Status of the ALS and APEX RF Systems at LBNL
A frequency choice for the SPL machine: Impact on hardware
Second SPL Collaboration Meeting, Vancouver May 2009
Developments of High CW RF Power Solid State Amplifiers at SOLEIL
SPL Collaboration Meeting PAC2009
BE/RF-IS Contribution to LIU C. Rossi and M. Paoluzzi
10 MHz amplifier status G. Favia
Application of the moderate peak power (6 MW) X-band klystron’s cluster for the CLIC accelerating structures testing program. I. Syratchev.
12 GHz High Power RF components requirements for CEA activities
Notkestrasse 85, Hamburg, Germany
CLIC Klystron based. Updates 2017.
RF Power for C75 - Resources
CEPC RF Power Sources System
RF Power for C75 - Resources
PEP-II RF System Status and Upgrades
Performance Recovery at CEBAF
Status of RF at HZB: BESSY II, MLS, bERLinPro and BESSY VSR
Command and Data Handling
Electron Collider Ring Magnets Preliminary Summary
DTL for MEIC Ion Injection
SNS-PPU upgrades the existing accelerator structure
Andrew Hutton Concept suggested independently by Haipeng Wang
Jiquan Guo, Haipeng Wang
RF system for MEIC Ion Linac: SRF and Warm Options
Presentation transcript:

RF Power Klystrons & 20 Year Look R. Nelson 7/15/15

Page 2 RF Power klystrons 8 x 13 kW klystrons

Page 3 Why A klystron? Best (only) choice at the time Easy to use: Input (drive), output (to CM), power source (CPS) High gain Moderate efficiency, when operating saturated –We don’t run there Existing design tweaked for frequency and power 2kW became 5kW (later 8), 1.3 GHz to GHz Water-cooled (most heat dumped into water) 33% efficient (rated power) A custom solution for our requirements

Page 4 RF Power –Only klystrons were considered –5kW saturated power using klystrons Up to 8 kW (FEL & 0L04) 42¼ cryomodules + capture = 340 klystrons Initial purchase: in FEL zones, 4 for cavity testing 1 prototype in FEL buncher Supplemental purchases: 120 for spares, FEL, 10 for 0L02 R100 upgrade Rebuilds along the way –4 x 1 kW SSAs for separation –IOTs: 4 for separation (499 & MHz)

Page 5 12 GeV Upgrade 80 cavities = 80 klystrons Higher efficiency, higher power –Purchase: 84 including first article Also considered IOT & SSA –IOT concerns »None built for GHz »Some in service at 1.3 GHz »Higher cost, lower gain (high drive required - 100W preamp vs 0.1 – 2 W –IOT advantages: efficiency –SSA: Advancing, but not there yet (cost, size, capabilities)

Page 6 How We’ve Fared Original spec asked for minimum 20k hour life Anticipated failures: 100 failures/yr. Didn’t happen Repair contracts (3) Rebuild up to 3 times Early fails: catastrophic not cathode depletion Internal leakage on ceramic Thermal runaway (mod anode effects) Leakage still most common fail –Imposes limits on tube

Page 7 Klystron Failures: Part 1

Page 8 Klystron Failures: Part 2 YearFailedWeeks Running FY20089 (11?) FY FY20107 FY20114 FY20125 FY

Page 9 Klystron Procurement Times Recent: R100 upgrade klystron buy (10 pcs) –Req entered: 10/1/12 –Signed/Bid: 10/3/ /20/12 –Placed: 12/21/12 –1 st received: 5/30/14 –Last received: 8/26/14 –5.4 months ARO for 1 st (8 mo from start) –Time to 10 th unit: 8.3 mo ARO (11 mo from start) –Maximum delivery rate?

Klystron Pros & Cons Pros Proven solution Long life Fits our sockets Easy replacement High gain High output power Cons Moderate / variable efficiency –Input power remains constant Rising replacement cost (like most things) “Dangerous” high voltage (…always touted by SSA proponents)

Page 11 SSA (Solid State Amplifiers) –Evolving, prices dropping, power per device up though GHz not a mainstream frequency Transistors developed for large markets – we’re a small user –Generally higher efficiency (more constant) –Complex designs (multiple stages, splitters, combiners, etc.) –Soft failure modes (gradual power loss) –“Safe low voltage operation” (50V/400A) –Major hardware changes to drop in –At $11/w, 88k$ per device X340 units = 30M$

SSA SBIR Efforts Several attempts over 10+ years Nothing usable yet Price, unknown SBIR companies typically not production capable, nor are developing an “Innovative” design

Page 13 SBIR: Design to Fit Our Space Multi-module amplifier could be installed in our HPA

Page 14 SBIR SSA

Page 15 Magnetrons Research being done here at JLab and looking with multiple approaches It’s an oscillator - industrial cookers, radar –Cost-effective power with high efficiency As an amplifier, more complex system (multiple magnetrons, waveguide components, etc.) Injection locking for frequency control, hybrid combining to adjust power? Modulated HV and magnetic? Not a drop-in replacement for our klystrons Significant changes – a new system (as with SSA)

Page 16 Other Magnetron Comments Shorter life (than klystrons or SSA) Applicability based on requirements Individual devices may cost less per watt, but additional hardware adds significant expense

Page 17 MEIC RF Power (H. Wang) CEBA F 12GeV E- Ring PEP-II 10GeV Ion-linac Pb 60MeV/u BoosterIon-Ring Pb 40GeV/u CC- ERL Cooler 55MeV Crab (16+6)X 2MV Frequency (MHz) / / Duty Cycle (%) cw 0.5ramp cw Cw Cavity sc 2Knc sc 2Knc/sc 2Ksc 2K Max Peak Power(MW) Average Power (MW) Klystron DC-RF Efficiency (%) na Magnetron DC- RF Efficiency (%) na DC Power Save (MW) na

Page 18 Future – Continue to Supply RF Continue buying present klystrons –… unless requirements change –2 vendors (one hasn’t built it since our original buy) – Prices on the rise 1990 $9k (Varian) 2000 $13k (Litton) 2012 $32k (L-3) 2014 $43k (budgetary) $60k ?? –Monitor options for alternate tech with major system changes –Monitor integrity of other components 1990$9kVarian 2000$13kL $32kL $43kL TBD??

Page 19 Klystron Health 2009 snapshot: 0.63/week of operation (.28 later) –How many weeks, how many failures? Expect rate to increase as EOL approaches –When? –Metrics not available to predict Spares: 12 on hand Installed: 16 poor (limited) tubes Cost: increasing –20 per year proposal wasn’t funded Arne suggests 500k$/year (~10 units per year) A good start – but start soon

Page 20 Thank You OK, we haven’t run out yet, but we really should buy klystrons… crying wolf?