Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair.

Slides:



Advertisements
Similar presentations
AIR DISTRIBUTION (Additional information. Also see Chapter 18) General The proper delivery of air for heating, cooling, or ventilation is a crucial part.
Advertisements

1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Building Science Basics WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
HVAC CONTROLS (See section 18.9)
TYPES OF MECHANICAL SYSTEMS
Heating Systems Forced Air Systems.
Innovative Solutions to Improve Comfort & Efficiency NEX and PLAY.
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
Airflow Properties & Measurement
The House as a System 1. Air Temperature and Water Vapor.
Trevor Thompson Senior Project II Vermont Technical College Spring 2011.
System Sizing. Proper System Design Load Calculation Equipment Selection Duct Layout Branch runs Terminations Start ups Customer checks.
HVACR416 - Design Humidification. Relative Humidity 1.Air in the home is artificially dried out when it is heated. 2.Because warm air expands, this expansion.
Standardized Curriculum WAP Training Plans and Resources.
Contributed by: Integrated Teaching and Learning Program, College of Engineering, University of Colorado at Boulder.
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
Comfortable homes that save the world Sustainable Environmental Economic Development October 27, 2007 Don Otto dpoconstruction.com Don Otto dpoconstruction.com.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
HVACR416 - Design Grills, Registers, and Diffusers.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 10 Spillage Test.
Drafts and Duct System Sizing
Thermal Physics III Cooling Processes Refrigerators, air conditioners, and heat pumps are devices that make heat flow from cold to hot. This is called.
HEATING AND COOLING SYSTEMS
AIR CONDITIONING (COOLING) UNIT 37 AIR DISTRIBUTION AND BALANCE
Day 3 Part 3 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Duct Sealing and Insulation TRAIN THE TRAINER WEATHERIZATION.
Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Lesson 1 Friction Chart Primer 1.3 Friction Chart.
Duct Design Basics Lesson 4 Manual D Primer. Duct Sizing 4.3.
Part 1 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Part 13 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Part 5 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Components of Construction part 2
Maria’s Restaurant Chapter 2 Section 9
Part 16 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Maria’s Restaurant Lesson 21 Appendix C Duct Design
Part 4 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Maria’s Restaurant Chapter 1 Section 4
Section 6: Air-Conditioning (Heating And Humidification)
Part 12 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Part 9 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Maria’s Restaurant Chapter 3 Section 13
Maria’s Restaurant Chapter 4 Section 15
Part 2 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Lesson 24 Appendix F Outside Air Calculation
Part 7 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Technician’s Guide & Workbook for Duct Diagnostics and Repair
Air-Row Fans Minimize Freezer Door Sweating
Notes 7: Using Heat Chapter 6 Section 3 Page 172.
Bell work Predict whether leaving the refrigerator door open on a hot summer day will help to cool the kitchen.
Maria’s Restaurant Chapter 3 Section 12
Maria’s Restaurant Chapter 4 Section 14
Technician’s Guide and Workbook for Zoning Section 3: Single Zone Airflow Balancing and Thermostat Location.
Flip The Long House Let’s imagine the Long house example in Manual J has undergone a house flipping/energy savings update. The insulation was increased,
Technician’s Guide and Workbook for Zoning Section 1: Introduction
Adding Zones to Existing Systems
Temperature and Comfort Complaints
Zoning Load Calculations
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Zoning Methods There are an unlimited number of ways to zone a home! Popular ways include: More than one single zone HVAC system. Zone damper systems.
Mandatory Design Requirements
Excess Air Management Overview
FBE03: Building Construction & Science
Maria’s Restaurant Chapter 3 Section 12
Maria’s Restaurant Chapter 2 Section 9
Lesson 24 Appendix F Outside Air Calculation
Presentation transcript:

Part 15 Technician’s Guide & Workbook for Duct Diagnostics and Repair

Section 5.3: Comfort “War” Stories Part 2

Stories 5 & 6 Measure the airflow from the register with a AMD As mentioned earlier, the airflow can be reverse engineered by measuring the room’s area and the CFM at the supply registers and return grilles. An Air Measuring Device (AMD) can be used to measure the rate at which air flows through any register. As noted earlier for flows below 500 CFM, a fan powered AMD is recommended, and for higher flows a commercial unit is recommended. The airflow rate into the cold room is measured

Stories 5 & 6 with the AMD and divided by the room area in square feet (ft 2 ). This provided CFM per ft 2. That area per CFM may then be compared to similar rooms, another method is to compare the result to the CFM per ft 2 for the whole building (this approach is best for commercial spaces where CFM per ft 2 is often different in perimeter and interior rooms). Where all of the conditioned spaces are similar, the number can be found by dividing the airflow through the furnace by the total condition space area in ft 2.

Stories 5 & 6 If the ratio for the room is about less than 80% of that for the house, insufficient supply air is probably a major cause of the problem. Story 5: A cold room with a single supply register was found to have 40 cfm of supply air for a room area of 175 ft 2. The conditioned area of the building was 1950 ft 2, and the measured fan flow rate was 1050 cfm. Taking the cfm/ft 2 for the building (1050/1950) gave 0.54 cfm/ft 2 as a benchmark. Calculating cfm/ft 2 for the room

Stories 5 & 6 If the ratio for the room is about less than 80% of that for the house, insufficient supply air is probably a major cause of the problem. yielded 40/175, or cfm/ft 2, and 0.229/0.54 = 42.2%, a value well below 80% of design. Low supply airflow is a major cause of the problem. Example 6: A cold room with a single supply register was found to have 80 cfm of supply air for a room area of 175 ft 2.

Stories 5 & 6 The conditioned area of the house was 1950 ft 2, and the measured fan flow rate was 1050 cfm. Taking the cfm/ft 2 for the building (1050/1950) gave 0.54 cfm/ft 2 as a benchmark. Calculating cfm/ft 2 for the room yielded 80/175, or 0.457, and.457/.54 x 100 = 84.6%. Thus, since the supply airflow is above 80% of the design value, low supply airflow is probably not the major cause of the problem. As mentioned earlier in this section, the most likely culprit left is the air’s return path.

Stories 5 & 6 One easy/quick way to find out if a comfort problem is return airflow related is to leave the room door open. If the comfort problem goes away it is return airflow related. In this case opening the door made the room comfortable, and a jump duct was installed so the room had a return air path when the door was closed.

Story 7 Adjusting the airflow from the register by static pressure calculations When in the field, shortcuts that save steps are a great thing to know about. When you know the CFM through a duct and the SP you can calculate a new CFM based on the change in SP. It is often easier to use the place where the duct static pressure can be read and the formula to calculate the related change in CFM than it is to measure the CFM again.

The formula is: SP FINAL = SP BEGINNING ÷ (CFM BEGINNING ÷ CFM FINAL ) 2 where: CFM BEGINNING is the measured airflow in cubic feet per minute for the duct trunk (can be several diffusers added together or a traverse). CFM FINAL is the desired final airflow in cubic feet per minute for the branch (can be several diffusers added together or a traverse). SP BEGINNING is the measured static pressure at the measured CFM. SP FINAL is the measured static pressure that will provide the final CFM desired through the branch (can be several diffusers added together or a traverse).

Story 7 Story 7: There was a lack of airflow to the main bedroom in the home and the technician used a fan-powered AMD to measure the airflows at all of the other supply registers. It was not surprising the one hardest to reach and measure safely was the one that had way more it’s share of airflow. The supply register was located high on the wall in a two story entrance hall ceiling in the entrance of a house. There was easy access to the branch that ran over to it where a balancing damper had been located in the equipment closet on the 2 nd floor.

Story 7 After setting up a ladder and measuring 422 CFM with a fan powered flow hood (with a helper holding the ladder while he bent over in an awkward angle to hold the AMD) the technician decided to drill a SP measurement port in the branch between the damper and the supply diffuser and rather than climbing use the formula to adjust the damper. The SP was measured at 0.55 and he need the airflow to that register to be 250. At what SP should the technician set the damper?

Story 7 (Fan Law 2) SP FINAL = SP BEGINNING ÷ (CFM BEGINNING ÷ CFM FINAL ) 2 SP FINAL = 0.55 ÷ (422 ÷ 250) 2 SP FINAL = 0.55 ÷ (1.688) 2 SP FINAL = 0.55 ÷ 2.85 (rounded off from ) SP FINAL = 0.19 (rounded off again) The technician closed down the balancing damper until the SP was at The master bedroom airflow was improved and became within 80% of design.

Story 7 If the technician wanted to get more airflow into the master bedroom, all of the other supply registers would have to be measured again and the one that was the highest above the design value would be shut down at the balancing damper to the design value. Once that process was done (it may take adjusting several supply lines), and the master bedroom had the correct airflow (within 5%), the technician could go back and recheck the SP on the entrance hall trunk and if necessary close it down again until it was at 0.19.

Story 7 The adjustment handle was locked down, marked and screwed into position so it would not easily be moved again. Note: It is even better if the insulation covering it is repaired and sealed so no one will move the damper in the future. Note: For more instruction on air balancing see ACCA’s Manual B Balancing and Testing Air and Hydronic Systems.

Thermal Comfort When dealing with drafts, four rules of thumb will help when adjusting damper and register positions: For cooling, most people complain about a draft when they feel an airflow of over 75 feet per minute. For heating, most people feel a draft when the airflow is over 50 feet per minute. As humidity decreases in the air, people tend to want the temperature set higher (and vice versa). Women have more sensitive skin than men, and can feel temperature changes men cannot feel.

Thermal Comfort When the customer identifies a room, rooms, or the whole building as being chronically under- conditioned, a trained technician should be able to solve the problem and explain to the building owner how the work was completed. Although one may always install a larger air conditioner, or an auxiliary heating or cooling unit serving a poorly conditioned room, doing so to hide a duct problem that causes the building to heat and cool the whole neighborhood is not a professional approach.

Lessons Learned You should now be able to use AMD measured airflow to evaluate the CFM delivered to a room. You should now be able to use Fan Law 2 to calculate the new SP needed to provide the required CFM to an area. You should now be able to explain why a room feels drafty and recommend a fix.