Copyright © 2009 Toshiba International Corporation. All rights reserved. Hx7+Pack Drive Severe Duty Adjustable Speed Drive Prepared By: ASD Marketing.

Slides:



Advertisements
Similar presentations
Automation and Drives s SIRIUS 1 s s Class 70/71 Enclosed Starters.
Advertisements

Packaged Terminal Air Conditioners
Variable Frequency Drives Bypass Options
MEDIUM VOLTAGE VFD MOTOR CONTROLLER Liquid Cooled Components Active Front End - No Transformer 3300 – 6900 VAC 700 – 2500 HP Contact:
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
Daikin Altherma™ Troubling Shooting
Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
Engine & Transport Integrated Cooling Systems. © Alfa LavalSlide 2 Alfa Laval Integrated Cooling Systems, ALICS Integrated marine cooling.
Who is Stellar Tech?  Stellar Tech Energy Services is a wholly owned Canadian company  Manufacturer of WellMax Datalogger / Controller  Specializing.
VARIABLE SPEED DRIVES HARMONIC EFFECTS & EFFECT OF USE WITH LONG CABLES (100 – 300m) Electric Motors & Drives ….OUR VISION, YOUR SOLUTION ……. TOGETHER.
2010 ASHRAE Rocky Mountain Chapter VFD Fundamentals April 16, 2010 Jeff Miller - ABB © ABB Month DD, YYYY | Slide 1 1.
SmartVFD HVAC, BYPASS, NXL, NXS Introduction
POWER ELECTRONICS Multi-Step VSI vs GTO CSI. Power Electronics España S.L. © reserves the right to modify the content without prior notice 01 GTO CSI.
© Copyright 2008 ABB. All rights reserved /29/2008 Results-Driven Roadshow Cincinnati, 2008 Common Cures for Harmonics Larry Stanley RSE,Nashville,TN.
38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
Variable Frequency Drives VFD Basics
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
LP33 Series UPS kVA 400Vac/CE
Application Types Variable Torque Constant Torque.
WISA Meeting Help Arrange a Speaker, Write Bio, Introduce
POWER SUPPILES LECTURE 20.
1 HVAC 214 Electricity For Oil Heat Fan Center Relays.
Install IntelSteer Power Saver Device
LECTURE 28 AC Voltage Controllers Dr. Rostamkolai
Copyright © 2008 Rockwell Automation, Inc. All rights reserved. Direct-to-Drive Technology Product Feature Overview.
YASKAWA Mechatronics Solutions High Performance Inverter with Advanced Vector Control Varispeed G7.
Perfect solution for large building
POWER PLANT USED IN TELECOM
7154 VFD Presentation #2 May 2002 Paul Weingartner.
T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R SineWave - Installation rules.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
Air Handler Terminology
Variable Frequency Drives and Irrigation Pumps Stefanie Aschmann Bozeman, MT 11/30/11 1.
Air Handler Terminology
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. CENTERLINE 2100 Motor Control Center - SecureConnect™ September 1, 2011.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ SMC™ Flex Controller kV.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Modern electronics continue to be placed in denser packaging and smaller enclosures, often causing overheating problems Moisture and airborne dust, oil,
CUE – Make Any Pump an E-Pump
Cooling Systems. High temperatures can shorten the life expectancy of electronic components. High temperatures can shorten the life expectancy of electronic.
Variable Frequency Drive (VFD) Cable VFD Cable Solutions.
Copyright© 2005 Avaya Inc. All rights reserved Avaya UPS Training powerware.com/avaya.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Sigma Rotary Screw Compressors
Wholesale Medium Voltage Drives
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
 2008 Kaeser Compressors, Inc., USA (V4.1) SFC Product Introduction “Specifications are subject to change without notice” 1 SFC Sigma Frequency Controlled.
Air conditioning is a combination of activities such as conditioning the air i.e., heating or cooling, ensuring air.
VFD Basics and the Tower IQ June 10 th, The Rundown  Cerus Overview  VFD Basics  VFD Applications and Packages  Cooling Tower IQ  Questions.
Integrated Blower Packages Kaeser Integrated Blower Family.
Reliability in motion ™ Copyright © 2010 Toshiba International Corporation. All rights reserved Welcome.
Fan Coil Controller FC/S 1.1
Design, Evaluation and Application of a Fuel Cell Vehicle
Increase your efficiency with Schneider Electric
VFD = AFD = VSD = Adjustable Frequency Controller
MEDIUM VOLTAGE APPLICATIONS.
54 CHARGING SYSTEM CHARGING SYSTEM.
A New Chapter in Energy Savings and Power Quality
Pilot Operated Pulse Valve Manufactured by maniks
SPOC Automation and BECI- who are we?
Written by Tim Keyser Georgia CTAE Resource Network 2010
Moving your Control Forward - VFD from Unitronics
Power Electronic Drives - DC to AC converter / Inverter
Robicon Perfect Harmony.
Moving your Control Forward - VFD from Unitronics
Series 5300 Lithium Cell Formation System
Written by Tim Keyser Georgia CTAE Resource Network 2010
Automotive Technology Principles, Diagnosis, and Service
Presentation transcript:

Copyright © 2009 Toshiba International Corporation. All rights reserved. Hx7+Pack Drive Severe Duty Adjustable Speed Drive Prepared By: ASD Marketing

Copyright © 2009 Toshiba International Corporation. All rights reserved. Prior to viewing this presentation This presentation will assume the viewer has a basic understanding of Motor theory, and basic Drive theory.

Copyright © 2009 Toshiba International Corporation. All rights reserved. The HX7 Plus pack is a self contained Adjustable speed Drive, that is rated for outdoor use in direct sunlight With a Horsepower range from 60 Hp to 1500Hp The Plus Pack has been designed for the most brutal environments. Everywhere from the blistering heat of the desert, to the freezing arctic circle, to the corrosive offshore platforms, and even in underground mining applications. The Plus Pack is self contained, so that all that is required is the incoming power, and the motor leads. The drive is equipped with it’s own control power transformer, it’s own maintenance free cooling system, and advanced protective functions to make the drive as much a “Set it and Forget it” unit as possible. The Plus Pack springs from it’s predecessor the G3 Plus pack which earned a reputation for durability, ruggedness, and reliability. As a matter of fact, when we introduced the HX7 Plus Pack, customers expressed concern. They were happy with the G3 Plus Pack, and didn’t want it changed. The upgrade was necessary, as the components to produce the control boards were no longer available. The power platform of the Plus Pack was not redesigned, and is as reliable as the G3 Plus pack has proven to be.

Copyright © 2009 Toshiba International Corporation. All rights reserved. HX7 +Pack, 460V, >600HP Main Breaker Semiconductors Fuses Power Module B Power Module A Output Reactor Soft Charge Contactor Control Xfmer.

Copyright © 2009 Toshiba International Corporation. All rights reserved. Air-to-Air Heat Exchanger Heatsink through back of cabinet Input / Output Power Cables

Copyright © 2009 Toshiba International Corporation. All rights reserved. NEMA 4 Original Cabinet The Hx7+ NEMA 3R employs a modified NEMA 4 enclosure. High Performance Closed Cell Urethane for Gasketing and Sealing

Copyright © 2009 Toshiba International Corporation. All rights reserved. Fan (Ziehl-Abegg) External IP54 Heat-Sink Fans Heat Sink protrudes through the back of the modified NEMA 4 enclosure. IP54 Heatsink Fans Integral Motor and Fan in the airstream

Copyright © 2009 Toshiba International Corporation. All rights reserved. IP54 Fan Aluminum Heat-Sink Air Flow Aluminum ASTM 6063-T5 HEAT SINK High Corrosion Resistance Aluminum Heat sink

Copyright © 2009 Toshiba International Corporation. All rights reserved. NEMA 3R Heat Exchanger Heat-Exchangers eliminate the maintenance issues associated with refrigerant- based cooling units while preventing air exchange between the outside and inside of the cabinet. External Air Loop Internal Air Loop Heat Exchanger

Copyright © 2009 Toshiba International Corporation. All rights reserved. Heat-Exchanger Internal View Internal Air Loop Outlet Inlet

Copyright © 2009 Toshiba International Corporation. All rights reserved. Keypad’s Gasketed Window EOI (Keypad) is protected with a gasketed window Tool-less screws provide perfect tight sealing

Copyright © 2009 Toshiba International Corporation. All rights reserved. ASD L3L3 L2L2 Breaker Raycap L1L1 Plus Pack Optional Voltage Surge Suppressor

Copyright © 2009 Toshiba International Corporation. All rights reserved. PWM inverter Voltage Sine-Wave Motor Voltage Plus Pack Optional Sine-Wave Filter Reactor Capacitor

Copyright © 2009 Toshiba International Corporation. All rights reserved. Newlands Northern Underground Glenden-Australia NEMA 3R Plus Pack 460V/1200kVA (Schlumberger) Sine Wave Filter mounted in bottom section under enclosure doors

Copyright © 2009 Toshiba International Corporation. All rights reserved. Optional 12 Pulse Plus Pack In an effort to minimize Harmonic Distortion transmitted up the incoming power lines, that will minimizes transformer and motor heating; The 12 pulse option will require an external phase shift transformer to be purchased, contact the Application engineers helpline for specific details and specifications for the transformer. The difference between the 6 pulse and the 12 pulse is the rectifiers, and a second circuit breaker installed There will also be some cabling changes to accommodate the transformer

Copyright © 2009 Toshiba International Corporation. All rights reserved. Optional 18 Pulse Plus Pack Meets IEEE 519 The 18 pulse option comes with the transformer installed in the enclosure, as a total pre- engineered package. The pre- engineered package utilizes Toshiba’s Patented Asymmetrical 18 pulse front end technology.

Copyright © 2009 Toshiba International Corporation. All rights reserved. NEMA 3R 18-Pulse Plus Pack 460V/500kVA Bakersfield California, USA Bakersfield California, USA G7 NEMA 3R G7 NEMA 3R

Copyright © 2009 Toshiba International Corporation. All rights reserved. Bypass Options Isolated 3 contactor bypass or Soft Start bypass A bypass can be used to isolate a failed drive, or if full speed will be used for extensive periods of time. This option is normally used in critical applications, or when a starting surge cannot be tolerated for any reason.

Copyright © 2009 Toshiba International Corporation. All rights reserved. NEMA 3R Plus Pack 460V/500kVA Exhaust Fan Underground Zinc Mine, Tennessee

Copyright © 2009 Toshiba International Corporation. All rights reserved. NEMA 3R Plus Pack 460V/200kVA Oil Pump Jack, PDVSA, Zulia, Venezuela.

Copyright © 2009 Toshiba International Corporation. All rights reserved. NEMA 3R Plus Pack 460V

Copyright © 2009 Toshiba International Corporation. All rights reserved. Plus Pack 460V (Schlumberger) Algeria Algeria

Copyright © 2009 Toshiba International Corporation. All rights reserved. Plus Pack 460V Corona, CA Corona, CA