SKIPPER Electronics AS Enebakkveien 150 0680 Oslo Tlf. +47 23 30 22 70 Fax +47 23 30 22 71 The Multi.

Slides:



Advertisements
Similar presentations
INTRODUCTION TO Wi-Fi TECHNOLOGY.
Advertisements

Yokogawa Network Solutions Presents:
T-Mon SERVER CONNECTOR
ARSP Operation Instruction
This presentation is intended to assist you in troubleshooting basic problems that can occur with hardware and software. NOTE: This presentation contains.
IP Forwarding Relates to Lab 3.
In this presentation you will:
Crown DSi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
Riso Digital Education Center Appendix for SRC Training Basic Course 1.
KX-NS1000 Initial Set Up For step by step : 16 May,
DIR-505 All-in-One Mobile Companion Greg Quinlan Technical Trainer.
1 © 2004, Cisco Systems, Inc. All rights reserved. Wireless Access Points (WAPs) or (APs)
04/26/2011Marshall Electronics, Inc. © H.264 Cameras and Servers Sales & Technical Training Presented By: Jim LucasNigel Hamley, MBKS Product ManagerManager.
Graphical Alarm Management System
TAX-AIDE Network Router Setup Network Printer Setups July SMT/TCS Training - Dallas1.
AXIS 2460 System Overview  AXIS ETRAX 100LX  ARTPEC-1  4 MB FLASH  32 MB RAM  Up to 4 internal IDE hard disks  Linux 2.4.
Ch. 5 – Access Points. Overview Access Point Connection.
Uniflair pCOWeb Ethernet interface card.
Chapter 8 Input/Output. Busses l Group of electrical conductors suitable for carrying computer signals from one location to another l Each conductor in.
A BRIEF INTRODUCTION TO FIELDBUS 4 hf NETLOGIC PLC TRADITIONAL CABLING SYSTEM TERMINAL BOARD.
ActEyes IP Cam Training Part 1: Camera Setup. Network Setup Overview Each IP Cam on the network will need its own IP address to be assigned. This address.
Private and Confidential TraceTek iServer Concepts, Set-up, Operation.
Lexmark Wireless Printer Adaptor Instructions Step 1. For a Mac, go to network preferences/ select built-in-ethernet and click on TCP/IP tab and annotate.
ACM 511 Chapter 2. Communication Communicating the Messages The best approach is to divide the data into smaller, more manageable pieces to send over.
Students are able to generate a one-time login through their VTAC User Account.  The login details will need to be forwarded to the person nominated to.
Copyright 2000 eMation SECURITY - Controlling Data Access with
How to setup Genesis LC1 and Genesis Flex with the Buffalo Access Point to maximize wireless performance…
The New FTC Platform (Connecting your legacy hardware)
DHP Agenda: How to Access Web Interface of the DHP-1320 on Access Point Mode How to Access Web Interface of the DHP-1320 on Router Mode How to Change.
McGraw-Hill©The McGraw-Hill Companies, Inc., 2004 Connecting Devices CORPORATE INSTITUTE OF SCIENCE & TECHNOLOGY, BHOPAL Department of Electronics and.
Envision Tutorial Horner APG, LLC July 18, Introduction The Cscape Remote Viewer allows remote interaction with the user interface on Horner OCS.
CCNA2 Chapter 2 Cisco IOS Software. Cisco’s operating system is called Cisco Internetwork Operating System (IOS) IOS provides the following network services:
Quick guide to ASIMON configuration For version 3.0 or greater SAFETY AT WORK Date: 3/18/2009.
An Overview When Connecting to Yaskawa Drives Date: 8/14/06, Rev: PP.AFD.26.
Cisco 2 - Routers Perrine. J Page 16/26/2016 Chapter 2 Cisco IOS Software Cisco’s operating system is called Cisco Internetwork Operating System (IOS)
Xbox Wireless Errors & Troubleshooting. Network: Failed Internet: Failed Xbox LIVE: Failed NAT: Connection Warning.
Presenting by Yogesh and Babakhan
Chapter Objectives In this chapter, you will learn:
Unit Hardware Troubleshooting
Industrial communication networks
COSEC ARC IP based Access Control Panel.
IP-based 8-port Switched Power Manager
SMS module HDL-MGSM.431.
Always Connected introduces Tigo SMART 3.0 This guide is interactive!
The Multi Series DL2-Multi
KX-NS1000 Initial Set Up Rev Oct.,
Haiwell PLC Modules Introduce
Computer Networking Devices
Em4 Ethernet tutorial Remote connection.
LXI Consortium Presentation Aug 5, 2017
Enjoy Hulu Plus On Vizio TV Smart Tv Help Line Toll Free ( )
LCD Network Monitor.
fischertechnik® RoboPro Software for Gateway To Technology® RoboPro
Wired Networks CIT 1100 Chapter4.
Setup Of 4050 EIP To Control LOGIX PLC
FIXMYWIFI EXTENDER. STEP 1: OPEN THE DEVICE FROM THE PACKED BOX, THEN CONNECT THE ANTENNA TO THE DEVICE, AFTER COMPLETING THE PROCESS OF CONNECTING.
HOW TO SETUP DLINK ROUTER?. STEP 1: You need to start from connecting the hardware.You need to unplug your modem from the power source. If you cannot.
Programmable Logic Controllers (PLCs) An Overview.
NForm 2.0 Training.
Always Connected introduces Tigo SMART 3.1 This guide is interactive!
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
ABC Wireless Vibration Meter
How to output NW camera picture to external monitor.
Total HVAC Control from anywhere Easy control that can save a fortune
Networking and Network Protocols (Part2)
IP Forwarding Relates to Lab 3.
Cisco Routers Presented By Dr. Waleed Alseat Mutah University.
KX-NS Step by Step Guide Initial Setup
How to install and manage exchange server 2010 OP Saklani.
Presentation transcript:

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax The Multi Series The DL1-Multi SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax DL1 Multi. Navigational speed log. 1 axis STW. DL1 Multi is the first product in a new series of speed log and echo sounder products. The new series is developed around a new electronic unit JB70. It features modern LAN communication and web setup in addition to all required I/O’s. DL1 Multi

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax ADD picture and connection of connector and AUX DL1 Connection

Auxiliary Connection SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax Dual Power supply I/O Multi extension PCB JB70D1-SA

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax CD402CU-SC

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax Optional LAN switch for setup from PC

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax The DL1-Multi has 2 boxes: 1.The CD402CU A dot matrix control unit, with local 24V that gets a bit map sent from the Electronic unit. And sends all button presses via LAN or Network 2.The JB70D1 The brains of the system, providing the IO to the bridge and information to the user control unit Both units have an IP address, and support the IEC Light ethernet standard DL1 Setup using the Web pages

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax The Standard is designed to send NMEA style messages over internet. Broadcast- All systems on the network can see the messages Groups are provided to limit the amount of messages the input has to look at Point to point – Each system has a unique identity (VD1234) Each message can be sent from and to, or to everyone. The DL1-Multi screen and electronics box are ‘paired’ to each other and send proprietry messages at 2 Hz. Alarms – Alarms have a similar point to point system new alarm messages for INS (IEC61924) standard IEC Light ethernet standard

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax To get to the web page you need a browser Direct cable axis – PC must be set to a static IP address, similar to the Box IP address Through a switch, just type the IP address in the browser DL1 Setup using the Web pages The DL1-Multi units have IP addresses with a number similar to the serial number. Printed on serial number. Once in the Web page the system can be set up and paired. It is possible to pair more than 1 display to the unit.

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax Setup IO Calibrate (quick) No heading calibration on 1 Axis. It must be correct Single high speed calibration often enough Calibrate (Sea test) Single high speed calibration often enough Other special features for DL1-Multi Ping size Standard says measure within first 3 meters under the vessel (2ms) – Can be extended to 8ms(12m) for higher resolution and more stability, but may cross a layer. Using The DL1-Multi

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax Built in test. There are 10 tests some require special loop plugs 1-4 are internal tests Electronics and communication to the sensor Test 5-9 are factory tests, but can be checked in the filed by making connectors that loop inputs to outputs Test A is a Raw input monitor theat monitors the input from the sensor. $PSKPDAT,1,FWD,Q,AFT,Q,Temp,XXX,YYY,ZZZ*nn It shows a fwd speed (unscaled) and its quality 1-8 >3 is ok but normally 8 It shows a Aft speed (unscaled) and its quality 1-8 >3 is ok but normally 8 It checks if these meet quality parameters (these should be close to the same but in opposite directions) Other special features for DL1-Multi

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax Sensor alarm If the sensor detects a failure of communications or some critical component it will send a sensor alarm If the control unit is not communicating – ERROR on screen with flashing dot If control unit freezes – dot stops flashing ??If electronic unit freezes – dot stops flashing 10 seconds,and then ERROR after some time and dot restarts If sensor quality is too low. The NMEA output and screen will show.... If communication to the system is bad then ---- for checksum error If there is no input where expected each individual line will read ERROR Other special features for DL1-Multi

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax Simulate a speed The sensor can be made to run a DEMO mode where the user selects a speed, and the system runs it from sensor to display. Set the speed and press set (or run from web) The Sensor sends a frequency from 1 transducer to the other, and back, and measures the signal This will test the transmitter, the receiver and all system parts. Water is not needed. SKIPPER Service software Check what is connected Quick set up Check the sensor messages directly Check the raw data of the sensor. Test if your installation is optimal (Noise floor) Test if your signal strength is strong enough Other special features for DL1-Multi

SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax SKIPPER Electronics AS Enebakkveien Oslo Tlf Fax The Web page To use some parts of the web page you need to enter the service password ‘service’ All can be changed and set up Calibration can be run from here if required Diagnostics of power supplies Set up of communications Other special features for DL1-Multi