Basic Principles of CT Scanning. CT CT - Computed Tomography CAT Scan - Computerized Axial Tomography.

Slides:



Advertisements
Similar presentations
PRINCIPLES OF CT.
Advertisements

IMAGE GENERATION IN CT.
Computed Tomography Principles
CT Scanning: Dosimetry and Artefacts
Computers and Computed Tomography
Image Reconstruction.
Computed Tomography Basic principles V.G.Wimalasena Principal
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University Lecture 6 Basic physical principles of.
Spiral CT Bushong Chapter 5.
Seeram Chapter 13: Single Slice Spiral - Helical CT
NC HPS Meeting 10/18-19/2001 Boone, NC Recent Advances in CT Technology and Issues of CT Dosimetry T. Yoshizumi 1,2, M. Sarder 1, R. Reiman 1,2, E. Paulson.
MULTISLICE CT.
COMUTED TOMOGRAHY Dr. Amr A. Abd-Elghany 1.
Computed Tomography.
RAD 354 Chapt. 23 Multi-slice CT In short – CT is a thin band (fan) of radiation directed toward the pt. and the remnant radiation emitted from the pt.
CT physics and instrumentation
CT Multi-Slice CT.
Computed Tomography III
Computed Tomography RAD309
Special Imaging Techniques Chapter 6 Bushong. Dynamic Computed Tomography (DCT) Dynamic scanning implies 15 or more scans in rapid sequence within one.
tomos = slice, graphein = to write
Chapter 2 Stewart C. Bushong
CT scanning (f) Candidates should be able to show an understanding of the principles of CT scanning. (g) Candidates should be able to show an understanding.
Computed Tomography
Conventional and Computed Tomography
LEC ( 2 ) RAD 323. Reconstruction techniques dates back to (1917), when scientist (Radon) developed mathematical solutions to the problem of reconstructing.
Basic principles Geometry and historical development
COMPUTED TOMOGRAPHY I – RAD 365 CT - Scan
Without reference, identify principles relating to Computed Tomography Clinical Applications with at least 70 percent accuracy.
Alhanouf Alshedi CT Physics and Instrumentation RAD
1 RT 255 C Cross Sectional Anatomy Week 1 FINAL
Medical Image Analysis Medical Imaging Modalities: X-Ray Imaging Figures come from the textbook: Medical Image Analysis, Second Edition, by Atam P. Dhawan,
Computer Tomography By Moustafa M. Mohamed. Introduction to Medical Imaging Uses of medical imaging Obtain information about internal body organs or the.
SPECIAL IMAGING/ADVANCED IMAGING INTRODUCTION TO DIGITAL RADIOGRAPHY
CT Seeram: Chapter 1 Computed Tomography - An Overview.
Computed Tomography Q & A
PRINCIPLES OF CT Dr Mohamed El Safwany, MD. Intended learning outcome The student should learn at the end of this lecture principles of CT.
Factors affecting CT image RAD
IAEA International Atomic Energy Agency Optimization of Protection in Computed Tomography (CT)-What can radiographers do? IAEA Regional Training Course.
▪ History ▪ Equipment ▪ Image Production/Manipulation.
QIBA CT Volumetrics - Cross-Platform Study (Group 1C) March 18, 2009 Interclinic Comparison of CT Volumetry Quantitative Imaging Biomarker Alliance.
Methods of Data Acquisition. General Methods of Data Acquisition Localizer scanning Step-and-shoot (axial) scanning Helical scanning.
RAD 254 –Chapt 23 Mulit-slice Computed Tomography
The production of X-Rays X-Rays are produced whenever charged particles are slowed down or stopped. X-rays are generated via interactions of the accelerated.
Module D Computed Tomography Physics, Instrumentation, and Imaging.
Image Display. But first a review Remember the 3 main steps 1. Data Acquisition 2. Image Reconstruction 3. Image Display.
Part No...., Module No....Lesson No
Part No...., Module No....Lesson No
Revision Imaging Procedure 3 Dr Mohamed El Safwany, MD.
CT Chapter 4: Principles of Computed Tomography. Radiography vs. CT Both based on differential attenuation of x-rays passing through body Radiography.
Computed Tomography(CT, was CAT, Computerized Axial Tomography) rev this is now slide 1do not print it to pdf things to do (check off when complete):
CONVENTIONAL AND SPIRAL/HELICAL CT
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
Radiology Course CT scan
Computed Tomography The images in the following presentation follow the “fair use” rules of the U.S. Copyright law.
Computed tomography. Formation of a CT image Data acquisitionImage reconstruction Image display, manipulation Storage, communication And recording.
IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
CT Scanner Detection system. 2 CT Scanner n Generator s High frequency, kW n X-ray tube s Rotating anode, high thermal capacity: 3-7 MHU s Dual.
Medical imaging (CT SCAN, NMR) to study some of the cases are diagnosed radio graphically by physical applications. By Ali Adil Turki Aldalawi (MEDECAL.
Single Slice Spiral - Helical CT
CT Multi-Slice CT.
Computed Tomography Basics
Computed Tomography Data Acquisition
Computed Tomography Basic principles Tamer M. Nassef.
CT PRINCIPLES AYMAN OSAMA.
Advantages of spiral CT
Physics Testing for ACRIN 6678 Protocol version 3.0 QIBA Group 1C
Basic principles Geometry and historical development
Basic Principles of CT Chapter 1.
Computed Tomography (CT)
Presentation transcript:

Basic Principles of CT Scanning

CT CT - Computed Tomography CAT Scan - Computerized Axial Tomography

The basics of CT CT imaging chain System components Acquisition methods Image quality Applications

X-ray: The beginning X-Rays founded in 1895 by Wilhelm Conrad Roentgen

CT: The beginning CT founded in 1970 by Sir Godfrey Hounsfield –Engineer with EMI, LTD. –first applications were in neuroradiology

CT Scanner X-Ray modality used to view the body in cross section Used to determine –extent of trauma –location and type of tumors –status of blood vessels –pre surgical planning

CT System

Basic CT scanner components Gantry X-Ray Tube Detector Control Console

Gantry CT X-ray tube High voltage generator Detector array Data acquistion system Slip ring

The CT X-ray Tube Anode heat capacity –3.5 MHU up to 28 MHU Determines maximum mAs Determines volume length Dictates generator size

Detector Elements Capture energy that has not been attenuated by the patient

Control console Set scan parameters –kVp, mA, scan time, reconstruction filter, etc. Set scan mode –Surview, Axial or Spiral IRS (Image reconstruction System) Review and archive images Post-processing

Scanning methods Surview –AP,Lat –Surview, Scanogram, Topogram…. Conventional CT –Axial Start/stop Volumetric CT –Helical or spiral CT Continuous acquisition

Digital Projection X-ray tube and detector remain stationary Patient table moves continuously –With X-rays “on” Produces an image covering a range of anatomy –Similar to a conventional X-ray image, e.g. flat plate of the abdomen Image used to determine scan location

Axial CT X-ray tube and detector rotate 360° Patient table is stationary –With X-ray’s “on” Produces one cross-sectional image Once this is complete patient is moved to next position –Process starts again at the beginning

Volume CT X-ray tube and detector rotate 360° Patient table moves continuously –With X-ray’s “on” Produces a helix of image information –This is reconstructed into 30 to 1000 images

Volume Scanning: Pitch 1:12:1

Advantages of Volume CT More coverage in a breath-hold –Chest, Vascular studies, trauma Reduced misregistration of slices –Improved MPR, 3D and MIP images Potentially less IV contrast required Gapless coverage Arbitrary slice positioning

Fundamentals of Multislice CT

Multislice Fundamentals Everything is better (R)esolution –Z-axis, spatial, low contrast (S)peed –Temporal - bolus capture, stopped motion (V)olume –Thin slice - – organ-specific coverage (P)ower –Enough photons - uncompromising image quality

Single Slice =One10mm slice per rotation Dual Slice =Two5mm slices per rotation Quad Slice =Four2.5mm slices per rotation Multislice Effectiveness Everything is better –Resolution2x4x-8x –Speedsamesame –Volumesamesame –Powersamesame Dual Quad

.. single detector arcdual detector arc pre-patient collimation post-patient collimation x-ray tube focal spot ___ Mx8000 Dual Slice Dual Slice Detector Optimized for 2 Slice Acquisition

Approximately 10% more efficient than matrix detectors Variable Wide Area Detector Asymmetrix™ Variable detector length Fixed detector length Quad Detector Technology variable wide area detector Variable slice thickness –4 x 1mm –4 x 5mm –4 x 2.5mm –2 x 0.5mm –2 x 8mm –2 x 10mm

8 Element 2-D array 4 Slices Quad Technology How it works

CT CT attenuation information CT image quality

Attenuation X-ray beam passes through patient Each structure attenuates X-ray beam differently –According to individual densities Radiation received by detector varies according to these densities

Density information Transferred from detector to CT computer (A to D converter) Reconstructed by computer into a cross-sectional image –Displayed on screen –Each pixel displayed on monitor has varying brightness The greater the attenuation, the brighter the pixel The less attenuation, the darker the pixel

Density information Density values correspond to a range of numbers –Hounsfield scale

Window settings Window width –Determines range of CT numbers displayed on an image Values above this range = white Values below this range = black –Window level Sets the center CT number displayed on the monitor Determines the location on the Hounsfield scale about which the window width will be centered

CT image quality Spatial resolution –Ability to resolve small objects in an image –Measured in lp/cm

CT image quality Spatial resolution –Ability to resolve small objects in an image –Measured in lp/cm

Isotropic Imaging True 0.5mm Isotropic imaging

CT image quality Contrast resolution –Ability to differentiate small density differences in an image

Post Processing Options Visualization of vasculature in relation to pathology –Show course of vessels –Show stent placement –Define vascular stricture

Cervical Spine Spiral Acquisition Rotation – 0.75 sec Coverage – 160 mm Pitch – Acq. Time – 36 sec FOV – 250 mm ST – 1.0 mm Rec. Incr. – 0.6 mm Std Res. – 8 lp/cm 120 kV, 200 mAs CTDI 100 w – 39 mGy CTDI FDA w – 17 mGy Thin-Slice Spiral Neck

Neuro-Angiography Circle of Willis

Thin-Slice Spiral Lungs

MIP 4D-Angio MasterCut Panoramic View Renal Arteries

Ext. Spiral Acq. Spiral Acquisition UltraFast – 0.5 sec Coverage – 1400mm Pitch – 1.75 Acq. Time – 41.5 sec FOV – 420 mm ST –2.5 mm Rec. Incr. – 1.6 mm Std Res. – 8 lp/cm 120 kV, 96 mAs CTDI100w – 7.3 mGy CTDIFDAw – 4.9 mGy Extended Spiral Acquisition