Project members  S.Sarankokila (090404605025)  T.I.Nivetha (08010404605047)  S.Rajavenkatesh (090404605020) Under the Guidance of  Mr.R.Gopi, ME.,(PhD).,

Slides:



Advertisements
Similar presentations
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Advertisements

2.2 STRUCTURAL ELEMENT BEAM
2.2 STRUCTURAL ELEMENT Reinforced Concrete Slabs
An-Najah National University
Chp12- Footings.
Lecture 9 - Flexure June 20, 2003 CVEN 444.
T6. DESIGN OF REINFORCED CONCRETE BEAM Reinforced concrete framed building T6. Design of reinforced concrete beam page 1. Alaprajz Floor plan Beam: linear.
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Abstract This project is a structural analysis and design of a residential building located in JENIEN City, The building is consisted of 7 floors. The.
ONE-WAY SLAB. ONE-WAY SLAB Introduction A slab is structural element whose thickness is small compared to its own length and width. Slabs are usually.
Department of Civil Engineering NED University Engineering & Technology Building Prof Sarosh Lodi.
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Slab Design.
Reinforced Concrete Design II
Stresses Found In Structural Members. Forces Acting Simply Supported Beam 1.Bending.
Footings.
Code Comparison between
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Lecture 5 January 31,  Sudhir K. Jain, IIT Kanpur E-Course on Seismic Design of Tanks/ January 2006 Lecture 5/ Slide 2 In this Lecture Impulsive.
University of Palestine
Plain & Reinforced Concrete-1 CE-313
Al-Najah National University Engineering Faculty Civil Engineering Department Graduation Project: Analysis & Design of Warehouses in Jaba’-Jenin.
Reinforced Concrete Design
Lecture 2 - Fundamentals. Lecture Goals Design Process Limit states Design Philosophy Loading.
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
Structural Analysis and Design of
Graduation Project Thesis  
Prepared By: Mohammed wafiq omer Mahmoud hammad Abd Algani Sami Malath omair An-Najah National University Faculty of Engineering Civil Engineering Department.
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
AN-Najah National University Faculty of Engineering Civil Engineering Department Structural Design of a Hotel Building Prepared by: Mohammed Qawariq Faris.
◦ Ar-Rafedain building is 8 stories reinforced concrete building,located in Nablus city and used as commercial and residential building. ◦ The basement.
©Teaching Resource in Design of Steel Structures IIT Madras, SERC Madras, Anna Univ., INSDAG 1 COMPOSITE FLOORS - II.
Graduation project: Jaba’a Institution Supervised by: Dr. Riyad Abdel-Karim Awad Dr.Sameer El Helw Dr.Sameer El Helw By :Fadi Hamaydi.
Reinforcement Information - Code
CESL Hotel Unique – Toronto Chris O’Brien Eric Fraser Scotia Mabury
Practical Design of PT Buildings
Prof. Shrikant M. Harle Asst prof. Dept of Civil Engg PRMCEAM
AR362 - Structural Systems In Architecture IV Lecture : Foundations
Comparative Study of Chord forces in Flat Slabs due to Seismic loads in buildings of different plan aspect ratios Aman Gupta (B.Tech. student) Dr. S. Mandal.
Dr Badorul Hisham Abu Bakar
Confined Masonry Construction
Review of Indian Seismic Codes
ANALYSIS & DESIGN OF G+3 STORIED REINFORCED CONCRETE BUILDING
An-Najah National University Faculty of Engineering
Structural Design of Technology College in Hebron University
Outline: Introduction: a ) General description of project b) Materials
(i) proper arrangement of reinforcing bars and
Analysis and Design of Al-Affori hotel
SEISMIC ANALYSIS AND DESIGN OF AN APARTMENT BUILDING WITH SHEAR WALLS
FOR 5TH SEMESTER DIPLOMA IN CIVIL ENGINEERING
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
SINGLY REINFORCED BEAM (R.C.C)
Analysis and Design of Multiple story building
Analysis and Redesign of Al – Tatbeqea Faculty
SINGLY REINFORCED BEAM (R.C.C)
Design of Reinforced Concrete
Outline CH1.Introduction CH2.Preliminary Design CH3.3D Model.
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg.
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
An-Najah National University
By :Dr. Aeid A. Abdulrazeg
Supervisor: Dr. Mahmoud Dweikat.
Plain & Reinforced Concrete-1 CE3601
2.2 STRUCTURAL ELEMENT Reinforced Concrete Slabs
Analysis And Design Of AS-Shorooq Residential Building
An-Najah National University
Graduation Project 2 3D Seismic Design of Omar Al-Alool School
بسم الله الرحمن الرحيم RaRami Abu Baker An- Najah National University
OUTLINES - location & Description. Material properties.
Presentation transcript:

Project members  S.Sarankokila ( )  T.I.Nivetha ( )  S.Rajavenkatesh ( ) Under the Guidance of  Mr.R.Gopi, ME.,(PhD)., (Asst.Prof/Civil) KSRCE

DUCTILITY Ductility can be defined as the “ability of material to undergo large deformations without rupture before failure”. The property of the material or a structure indicating the extent to which it can deform beyond the limit of yield deformation before failure. The ratio of ultimate to yield deformation is defined as ductility.

Necessity of Ductile detailing as per IS 13920:1993 Ductile detailing is provided in structures so as to give them adequate toughness and ductility to resist severe earthquake shocks without collapse. Mild steel is an example of a ductile material that can be bent and twisted without rupture.

INDIAN SEISMIC MAP

PLAN OF THE BUILDING

DESIGN DATA

The Design data shall be as follows: Live load on Floors: 2.0 kN/m 2 (as per IS 875) Imposed load on Roof : 1.5 kN/m 2 (Roof is accessible- as per IS 875) Floor finish : 0.9 kN/m 2 Weathering coarse : 1.5kN/m 2 Location : BHUJ city Wind load : Not consider due to earthquake effects as per IS 456 – 2000, Table – 18. Concrete grade: M20 Steel grade: Fe415

Earthquake load : As per IS-1893 (Part 1) – 2002 Depth of foundation below ground : 1.5m Type of soil : Medium (fine grained sandy soil) Allowable bearing pressure : 130 kN/m 2 Storey height : 3.2 m Floors : G.F. + 3 upper floors. Ground beams : To be provided at 100 mm below G.L. Plinth level : 0.6 m Walls : 230 mm thick brick masonry wall only at periphery. Partition walls are 150mm thick. Size Of Column :300X500mm Size Of Beam :300X500mm, 300X400mm Plinth area : m 2

ANALYSIS

LOAD COMBINATIONS As per IS 1893:2002 (Part – 1), Clause , In the limit state design of reinforced and prestressed concrete structures, the following load combinations shall be accounted : 1) 1.5( DL+lL) 2) 1.2( DL+IL+EL) 3) 1.2( DL+IL-EL) 4) 1.5( DL+EL) 5) 1.5( DL-EL) 6) 0.9DL+ 1.5EL 7) 0.9DL-1.5EL Totally 35 members (Columns & Beams) are analyzed and the results are Tabulated.

LOAD COMBINATION – 1 [1.5(DL+IL)]

LOAD COMBINATION – 2 [1.2(DL+IL+EL)]

LOAD COMBINATION – 3 [1.2(DL+IL-EL)]

LOAD COMBINATION – 4 [1.5(DL+EL)]

LOAD COMBINATION – 5 [1.5(DL-EL)]

LOAD COMBINATION-6 [0.9DL+1.5EL]

LOAD COMBINATION-7 [0.9DL-1.5EL]

RESULTS OF ANALYSIS UNDER 7 COMBINATIONS FOR BEAM DESIGN MEMB ER NO NODE NO FORCESLOAD CASE 1 LOAD CASE 2 LOAD CASE 3 LOAD CASE 4 LOAD CASE 5 LOAD CASE 6 LOAD CASE Axial (KN) Shear (KN) Moment (KNm) Axial (KN) Shear (KN) Moment (KNm)

RESULTS OF ANALYSIS UNDER 7 COMBINATIONS FOR COLUMN DESIGN MEMB ER NO NODE NO FORCESLOAD CASE 1 LOAD CASE 2 LOAD CASE 3 LOAD CASE 4 LOAD CASE 5 LOAD CASE 6 LOAD CASE Axial (KN) Shear (KN) Moment (KNm) Axial (KN) Shear (KN) Moment (KNm)

RESULTS OF ANALYSIS UNDER 7 COMBINATIONS FOR FOOTING DESIGN MEMB ER NO FORCESLOAD COM 1 LOAD COM 2 LOAD COM 3 LOAD COM 4 LOAD COM 5 LOAD COM 6 LOAD COM 7 24 Axial (KN) Moment (KNm)

STRUCTURAL DESIGN

DESIGN OF TYPICAL ROOF SLAB (S3) Room size = 3.05m x 4.87m ly/lx<2 Hence Two Way slab Design load = 9.0 KN/m 2 M x,M y < Mu(lim) Hence under reinforced section AREA OF STEEL FOR SHORTER SPAN = mm 2 Provide mm c/c AREA OF STEEL FOR LONGER SPAN = mm 2 Provide mm c/c

REINFORCEMENT DETAILS SLAB NAME SLAB THICKNESS (mm) SHORTER SPANLONGER SPAN DIA OF BAR (mm) SPACING (mm) DIA OF BAR (mm) SPACING (mm) S S S S S S

SLAB REINFORCEMENT DETAILS

FLEXURAL MEMBERS 6.1 General These requirements apply to frame members resisting earthquake induced forces and designed to resist flexure. These members shall satisfy the following requirements The factored axial stress on the member - under earthquake loading shall not exceed 0.1 fck The member shall preferably have a - width-to-depth ratio of more than The width of the member shall not be less - than 200 mm The depth D of the member shall preferably be not more than 1/4 of the clear span.

DESIGN OF TYPICAL FLEXURAL MEMBERS Reinforcement at section 5 due to hogging moment = 105kNm (17 th member have be taken for design) d = 462.5mm Mu (lim) = kNm M u < Mu (lim) Hence the section is singly reinforced section bottom = mm 2 Provide 1nos of 20mm dia + 2nos of 10mm dia (ast pro = 470 mm 2 ) top = mm 2 provide 3nos of 16mm dia + 1nos of 10mm dia (ast pro = mm 2 )

COLUMNS 7.1 General These requirements apply to frame - members which have a factored axial stress in excess of 0.1 fck under the effect of earthquake forces The minimum dimension of the member - shall not be less than 200 mm. However, in frames which have beams with centre to centre span exceeding 5 m or columns of unsupported length exceeding 4 m, the shortest dimension of the column shall not be less than 300 mm The ratio of the shortest cross sectional - dimension to the perpendicular dimension shall preferably not be less than 0.4.

DESIGN OF TYPICAL COLUMNS Column With Uniaxial Bending Design : Size of the column = 300 mm × 500 mm Axial load = 405 KN (we have take10 th member) Moment = 134 KNm A sc = 1200 mm 2 Provided 6 nos of 16 dia. bars. V s = KN Provided 2 legged 300 mm c/c A sh = mm 2 Use 10 mm dia bars (78.53 mm 2 spacing of 75×78.53/62.18 = 95mmc/c

COLUMN REINFORCEMENT DETAIL

FOOTING When a column terminates into a footing or mat, special confining reinforcement shall extend at least 300 mm into the footing or mat.

DESIGN OF TYPICAL FOOTING Column size = 300X500mm SBC of soil = 130kN/m 2 at 1.5m depth Total load = kN Size of footing = 3.8mX2.26m M uy = kNm M ux = kNm d = mm Steel parallel to longer direction Ast = 2642mm 2 Provide 0f 80mmc/c Steel parallel to shorter direction: Ast = 1822mm 2 Provide 0f 80mmc/c

Footing reinforcement details

CONCLUSION In this project, we have successfully completed the “DUCTILITY DESIGN OF REINFORCED CONCRETE APARTMENT BUILDING”. It has been designed as per IS 13920:1993, “Ductile Detailing of Reinforced Concrete Structures Subjected to Seismic Forces — Code of Practice” We have gained enough knowledge in Load calculation, Analysis, Structural design and Ductile detailing of Earthquake Resistant RC buildings subjected to Seismic forces. Finally ‘Earthquake not kills, but the building to do so…’ as per the words, in future we design the RC buildings having adequate Ductility.

REFERENCES IS 13920:1993, “Ductile Detailing of Reinforced Concrete Structures Subjected to Seismic Forces — Code of Practice “, BIS, New Delhi. IS 1893:2002(Part 1), “Criteria For Earthquake Resistant Design of Structures”, BIS, New Delhi. IS 456:2000, “Plain and Reinforced Concrete - Code of Practice, BIS, New Delhi. SP: 16, “Design Aids For Reinforced Concrete”, BIS, New Delhi.

Damodarasamy.S.R., Kavitha.S. “Basics of Structural Dynamics and Aseismic Design”, PHI Learning Pvt. Ltd., Dr. Ingle. R. K, Dr. Sudhir K Jain, “Explanatory Examples for Ductile Detailing of RC Buildings” IITK-GSDMA Project on Building Codes. Murthy.C.V.R., “Earthquake Tips - Learning Earthquake Design and Construction”, Indian Institute of Technology, Kanpur. Bhattacharyya.S.K, “Guidelines for earthquake resistant design and Evaluation of earthquake forces”, IIT, Kharagpur. Pankaj Agarwal, Manish Shrikhande, “Earthquake Resistant Design of Structures”, PHI Learning Pvt. Ltd., 2006.

E arthquake Not Kills But The B uilding to do so… THANK YOU