TEKLINX PAKISTAN Your Embedded Solution Partner. Industrial Instrument: Coupling Decoupling Network. Equipment for EFT/Surge measurements, together with.

Slides:



Advertisements
Similar presentations
©2004 Fluke Corporation Introduction to Motor Troubleshooting 1 Introduction to Motor Troubleshooting.
Advertisements

Concept Design Review (CoDR) Shore Station DC Breaker Cable model Transient Analysis Components.
This lesson covers the following outcomes Unit 54 P1, P7, P8 Unit 6 P10, P11.
Using a 555 Timer.  Emits regular sounds, usually a single frequency tone, beat, or click, which instrument players and singers use to count the meter.
LP33 Series UPS kVA 400Vac/CE
The Basic Elements and Phasors
Basic Elements of Electrical Circuits Resistor Inductor Capacitor Voltage source Current source.
Interactive Engineering Workshop Eng. Mageda Al-Moubarak Eng. Fadia El-ssa.
Instrumentation: ground and noise Temperature Measurement.
Industrial Solutions and Services Your Success is Our Goal EMC Testing for Emission and Immunity Diethard E. C. Moehr, I&S CTF EMC.
EE 311: EE Junior Lab Experiment 5 - Single Phase Transformers J. Carroll 9/25/06.
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
Electronic Metronome Using a 555 Timer.
1 Complex Gain: Basic amplifier concepts Q: What is a Phasor? A Phasor is an ac voltage or current that maintains the same phase with respect to a standard.
Basics of Measurement and Instrumentation
1 Wireless power for mobile phones - System overview Nov 25, 2012 V1.1.
Lecture 2 Most basic facts from Electricity needed for understanding telecommunications Local transmission lines in the telephone system Decibels Signals.
Passive components and circuits
Chapter 6. Capacitance and inductance
Electromagnetism Topic 12.2 Alternating Current. Rotating Coils Most of our electricity comes from huge generators in power stations. Most of our electricity.
Electrical Distribution Systems
1 Chapter 6 Capacitors and Inductors 電路學 ( 一 ). 2 Capacitors and Inductors Chapter 6 6.1Capacitors 6.2Series and Parallel Capacitors 6.3Inductors 6.4Series.
EE1008- ELECTRICAL AND ELECTRONICS MEASUREMENTS AND INSTRUMENTATION
EE1008- ELECTRICAL AND ELECTRONICS MEASUREMENTS AND INSTRUMENTATION UNIT -1 Measurement of R, L, C 10/21/2015www.noteshit.com1.
EENG 2610: Circuit Analysis Class 10: Capacitors and Inductors
Electromagnetic Compatibility Test for CMS Experiment. Authors C. Rivetta– Fermilab F. Arteche, F. Szoncso, - CERN.
AC/DC Power Supply. Direct vs. Alternating Current.
Three Phase Motors Maths
ECE Networks & Systems Jose E. Schutt-Aine
EKT 101 Electric Circuit Theory
Unit 16 Inductance in AC Circuits
1 Eeng224 Chapter 10 Sinusoidal Steady State Analysis Huseyin Bilgekul Eeng224 Circuit Theory II Department of Electrical and Electronic Engineering Eastern.
AC Current An AC circuit consists of a combination of circuit elements and an AC generator or source The output of an AC generator is sinusoidal and varies.
Signal conditioning Noisy. Key Functions of Signal Conditioning: Amplification Filter  Attenuation  Isolation  Linearization.
Design and Development of Transient Network Analyzer By M.Satish kumar 04131A0241 P.Sasi kumar 04131A0240 T.Sirisha 04131A0244 V.S.Pramod 04131A0247 Under.
3 July July July Conventional X-rays Generator Basic components of an X-ray machine:  Electron source.  Vacuum where electrons were.
Electrical Measurement & Measuring Instrument
1 TRANSDUCER. 2 Contents To understand the basic concept of Transducer To learn about Block diagram of transducer Different Applications of transducers.
Electric Pressure Transducer
ET 332b Ac Motors, Generators and Power Systems 1 Lesson 11_et332b.pptx.
High Speed Properties of Digital Gates, Copyright F. Canavero, R. Fantino Licensed to HDT - High Design Technology
Chapter 5 Alternating Current
Chapter 6. Capacitance and inductance
Chapter 10 Magnetically Coupled Circuits and Resonance
Chapter 13 AC Measurements.
X Z rotor Istator stator out of page ICD into page rotation axis
Sensor presentation.
Speed control of three phase induction motor
Induction Motor as a Induction Genrator
EKT 101 Electric Circuit Theory
Aircraft Electrical Systems
Capacitive AC Circuits
Lesson 16: Asynchronous Generators/Induction Generators
EKT 101 Electric Circuit Theory
AC generators.
WELCOME TO ALL.
Sensor presentation.
Special Transformer Current Transformer ( C.T. )
Lesson 11: Transformer Name Plate Data and Connections
Exercise 8 Power systems.
ECE699 – 004 Sensor Device Technology
Analog and Digital Instruments
BE5B14SP1 – Electrical machines and electrical apparatus 1
Exercise 8 Power systems.
Lecture 10 - Transformers/Three-Phase Circuits
The failure analysis on common mode choke in circuit
POWER LINE CARRIER COUPLING DEVICE
AC current.
Presentation transcript:

TEKLINX PAKISTAN Your Embedded Solution Partner

Industrial Instrument: Coupling Decoupling Network. Equipment for EFT/Surge measurements, together with EFT/Surge generator. Specifications: Frequency Range: 1MHz~100MHz Coupling Capacitance: 33nF Damping between the output and the input: >20dB Rated Load: 20A Line voltages: 380V Phase voltage:220V

Industrial Instrument: Dry Heat Test Oven This chamber is used for test of heat stress on materials like Poly carbonate, ABS, Nylon etc. It can also be used to simulate the aging effect of electronic accessories. Specifications: Temperature Range: room temperature ~ 80’C Adjust able linear slope for temperature rise Uniform heat flow across the chamber Availability of Main voltage terminals Computer interface Capacity: 4.5 cubic Ft

Industrial Instrument: Dust Chamber Dust tests for equiment. Complies with IEC60529 Specification: Complies with IEC60529 Capacity: 10 Cubic Ft.

Industrial Instrument: Glow wire Tester Used for testing the material properties on extreme temperature ranges Specification: Temperature Range: Max 1000 ‘C Adjustable contact time Adjustable tension with glow element

Industrial Instrument: Impulse Generator Used for simulating the lightening surges. Specification: Max voltage: 10KV Standard 1.2 / 50us wave-form (+/-30%) Adjustable time between the surges Adjustable surge count. Oscilloscope output for impulse wave form viewing.

Industrial Instrument: Magnetic Tester For external Origin Magnetic ring coil is used to test the EUT under magnetic field disturbances. Specification: Max Flux: 0.5m Tesla Standard 1000 AT coil

Industrial Instrument: Power Frequency Tester This equipment is used for testing the insulation properties of EUT Specification: Max output potential: 10KV (Adjustable) Short circuit protection Program able stress time LCD Based interface / counter / voltage indicator

Industrial Instrument: Rain Fall Simulator Rain fall tester is used for simulating the raining scenario for EUT. Its use is to check and verify the sealing of EUT

Industrial Instrument: Short Time over Current Tester It is used for checking the EUT under severe short circuit and over load conditions. Specification: Output current range: 1200A / 3000A Time of pulse: 10ms Purely inductive solution