PVI Facts, Fallacies and Implications and the Need for 1,000+ Liter Indoor Air and Subslab Vapor Samples Roger Brewer, Josh Nagashima Hawai’i Department.

Slides:



Advertisements
Similar presentations
Sampling Design, Spatial Allocation, and Proposed Analyses Don Stevens Department of Statistics Oregon State University.
Advertisements

Presented by Shannon H. McDonald, P.G. August 4, 2010.
Lessons Learned Multi Incremental Sampling Alaska Forum on the Environment February, 2009 Alaska Department of Environmental Conservation.
Case Study of Subsurface Vapor Intrusion at a Dry Cleaner Site Amy Goldberg Day AEHS Annual East Coast Conference on Soils, Sediments.
COMPARISONS OF SUB-SLAB SOIL GAS MEASUREMENTS TO MODELED EMISSIONS FROM SUBSURFACE CONTAMINATION by John A. Menatti and Robin V. Davis Utah Department.
2014 Vapor Intrusion Guidance Amendments Discussion Points Waste Site Cleanup Advisory Committee Meeting May 22, 2014.
Vapor Intrusion. What is Vapor Intrusion? The migration of volatile chemical vapors from the subsurface to overlying buildings.
© 2011 COLUMBIA Technologies. Use of MiHpt Systems to Improve Project Outcomes Rapid, Real-Time High Resolution Site Characterization © 2013 COLUMBIA Technologies.
Dale T Littlejohn Senior Geologist. What is fate and transport in the vadose zone? Vadose Zone Hydrocarbon release from buried pipeline Aquifer Surface.
Spring INTRODUCTION There exists a lot of methods used for identifying high risk locations or sites that experience more crashes than one would.
Vapor Intrusion Guidance Proposed Updates
DRAFT Field Sampling Guidance To be used this field season by DEC and consultants Initial focus on soil, groundwater, and vapor intrusion Future versions.
Vapor Intrusion Evaluation Strategy and Modeling Developments
Revised TCE Fact Sheet (a.k.a. “Status Update”) Q&A’s & Template IH Notice Form March 27, 2014 Paul W. Locke MassDEP Bureau of Waste Site Cleanup (617)
Overview of US EPA’s Vapor Intrusion Guidance VAP CP Summer Coffee July 14 th, 2015 Carrie Rasik Ohio EPA CO- Risk Assessor
Of Massachusetts Department ENVIRONMENTAL PROTECTION Soil Vapor Intrusion... A Decade of Regulatory Requirements & Experiences Paul W. Locke MA DEP Bureau.
Introduction to Atlantic RBCA Version 3 Webinar May 4, 2013.
Gradient CORPORATION Vapor Intrusion Attenuation Factors (AFs) – Measured vs. EPA Defaults A Case Study Presented by Manu Sharma and Jennifer DeAscentis.
DTSC VAPOR INTRUSION GUIDANCE California Industrial Hygiene Council 16 th Annual Conference Dan Gallagher Department of Toxic Substances Control California.
COMMITMENT & INTEGRITY DRIVE RESULTS WAITING TO EXHALE – OR HOW TO MANUEVER THROUGH THE INDOOR AIR MAZE Vapor Intrusion Pathway By: Lisa Campe, MPH, LSP.
GeoSyntec Future Directions for Assessing Vapor Intrusion by Todd McAlary, GeoSyntec Consultants, Inc. AEHS VI Workshop October 19, 2004.
Modeling Vapor Attenuation Workshop A Study of Vapor Intrusion Modeling in the Context of EPA’s Guidance The 20 th Annual International Conference on Soils,
Discerning Background Sources from Vapor Intrusion Jeffrey Kurtz, Ph.D. and David Folkes, PE EnviroGroup Limited Denver Boston Albuquerque Seattle Colorado.
Step 1: Do Exclusion Criteria Exist?
SITE STATUS UPDATE TOP STOP PETROLEUM RELEASE SITE GUNNISION, UTAH Morgan Atkinson – Division of Environmental Response and Remediation, Project Manager.
USEPA Region 2 Vapor Intrusion Study Cayuga Groundwater Contamination Site March 4, 2009.
Air Quality & Traffic August 25, 2015.
Carousel Tract Environmental Remediation Project Update by Expert Panel to Regional Board July 11, 2013.
1 of 36 The EPA 7-Step DQO Process Step 6 - Specify Error Tolerances (60 minutes) (15 minute Morning Break) Presenter: Sebastian Tindall DQO Training Course.
September 18, 1998 State of Illinois Rules and Regulations Tiered Approach to Corrective Action (TACO) Presented by The Great Plains/Rocky Mountain Technical.
CALIFORNIA’S AIR TOXICS PROGRAM: IMPROVEMENTS TO ASSESS HEALTH RISK Update to the Air Resources Board July 24, 2014 California Environmental Protection.
Vapor Intrusion Guidance Updates VAP CP Training October 27, 2015 Audrey Rush Ohio EPA DERR
A presentation for by ROUX ASSOCIATES, INC. Environmental Consulting and Management International Petroleum Environmental Conference 22.
Exposure Assessment for Health Effect Studies: Insights from Air Pollution Epidemiology Lianne Sheppard University of Washington Special thanks to Sun-Young.
Charge Questions for Expert Panel Modeling Vapor Attenuation Workshop Annual International Conference on Soils, Sediments, and Water October 19, 2004 Amherst,
RISK DUE TO AIR POLLUTANTS
1 of 31 The EPA 7-Step DQO Process Step 6 - Specify Error Tolerances 60 minutes (15 minute Morning Break) Presenter: Sebastian Tindall DQO Training Course.
Long-Term Management of Contaminated Soil and Groundwater – Iwilei District, Honolulu April 16, 2015.
Vapor Study Informational Meeting General Mills/Henkel Corp. Superfund Site Van Cleve Recreation Center November 12, 2013 Minnesota Department of Health.
Field Investigation of the Chemistry and Toxicity of TPH in Petroleum Vapors: Implications for Potential Vapor Intrusion Hazards Roger Brewer & Lynn Bailey.
Building Trust. Engineering Success. Real-time Vapor Intrusion Investigations in Industrial Buildings Using Portable GC-MS Presented by: Paul Gallagher,
Dungeons, Dragons, Pica Houses and the Need for Alternative, Vapor Intrusion Screening Tools Roger Brewer, Josh Nagashima, Mark Rigby, Martin Schmidt,
HEER Webinar (note change on mainland due to Daylight Savings Time) When:March 11 th, 2015 Time:11am-12pm Hawaii Time (2:00pm Pacific Time, 5:00pm Pacific.
Risk CHARACTERIZATION
By Robin V. Davis, P.G., Project Manager, retired Utah Department of Environmental Quality Leaking Underground Storage Tanks
Welcome to the World of AUL Avoiding the voidance of your CNS.
GSI ENVIRONMENTAL INC. Houston, Texas (713) Workshop 1: Assessment and Evaluation of Vapor Intrusion at Petroleum.
What’s the Problem: The Vapor Intrusion Issue Brownfields 2008 Heavy Starch: Cleaning the Dry Cleaners Detroit, MI May 5, 2008 Presented by: Henry Schuver,
Proposed Plan for No Further Action
Presentation on Livermore Lab Site 300 Superfund Cleanup Peter Strauss, Environmental Scientist, PM Strauss & Assoc. Community-Wide Meeting on
Chloride in Urban Streams in Maine
Statistical Methods for Model Evaluation – Moving Beyond the Comparison of Matched Observations and Output for Model Grid Cells Kristen M. Foley1, Jenise.
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
General Principles for Hydrocarbon Vapor Intrusion
East Hennepin Avenue Site
Chemical Metals Industries, Inc. (CMI)
Sean Anderson, P.Eng., QPESA Steve Russell, B.Sc., QPRA
Jay Peters Gina M. Plantz Richard J. Rago
Using the HAPSITE® as a Vapor Intrusion Investigation Tool
At facilities with subsurface contamination, what other chemicals may your workers be breathing? Matt Raithel.
Connecticut Remediation Standard Regulations: Volatilization Criteria
Network Screening & Diagnosis
Hold Your Breath—Ohio EPA’s TCE Initiative
Adjusting the Regional Haze Glide path using Monitoring and Modeling Data Trends Natural Conditions International Anthropogenic Contributions.
Bart Ostro, Chief Air Pollution Epidemiology Unit
EAST GRADE course 2019 Introduction to Meta-Analysis
A&WMA Regulatory Conference Symposium UST Risk Based Corrective Action
Brownfield Corrective Action with Revised RRS
Chemical Metals Industries, Inc. (CMI)
VI Issues: Lessons Learned
Presentation transcript:

PVI Facts, Fallacies and Implications and the Need for 1,000+ Liter Indoor Air and Subslab Vapor Samples Roger Brewer, Josh Nagashima Hawai’i Department of Health Battelle Conference, Palm Springs, CA, May 2016 (mod 7/1/16) 1

Subslab Attenuation Factors: Brewer, R., Nagashima, J., Rigby, M., Schmidt, M. and O'Neill, H. (2014), Estimation of Generic Subslab Attenuation Factors for Vapor Intrusion Investigations. Groundwater Monitoring & Remediation, 34: 79–92. Hawai’i DOH References Petroleum Vapor Intrusion: Brewer, R., Nagashima, J., Kelly, M., Heskett, M. and M. Rigby Risk-Based Evaluation of Total Petroleum Hydrocarbons in Vapor Intrusion Studies: International Journal of Environmental Research and Public Health, Volume 10, pp HDOH Technical Guidance and Webinars: Guidance Documents: Technical Guidance Manual (field investigations) Environmental Hazard Evaluation (action/screening levels)

PVI Fallacies 1.Middle distillate fuels like diesel and jet fuel are not volatile; 2.Petroleum vapors are dominated by benzene and other aromatics; 3.Risk-based indoor air and soil gas action (screening) levels cannot be developed for TPH; 4.Benzene and/or other aromatics always drive PVI risk, including both gasoline and middle distillate fuels; 5.Vapor-phase aliphatics degrade much faster than aromatics (e.g., Biovapor model); 6.TPH (i.e., non-BTEX fraction) degrades below levels of PVI concern within three feet of the source; 7.Small volume, subslab soil vapor samples are best able to capture “hot spots” and assess worst-case vapor intrusion risk; 8.Exceeding a screening level implies a potential risk. 3

Fact #1: Diesel & Jet Fuels Generate Significant Vapors (see Brewer et al 2013) TPH dominated by C5-C8 to C9-C12 aliphatics (volatile component of fuel); Relative proportion of C9-C12 compounds in vapors varies widely; Request lab to report TPH as sum of C5-C12 (not “TPHd”). Weathered JP-4/JP-8 Vapors Weathered Diesel Vapors TPH = 37,830,000 µg/m 3 TPH = 5,923,000 µg/m 3 Hawaii subslab soil vapor screening level = 130, 000 µg/m 3

Fact #2: TPH Dominates Petroleum Vapors (and aromatics appear to be removed faster than aliphatics) TPHBTEXN (see Brewer et al 2013)

Fact #3: Risk-Based Methods for TPH Available Since 1990s (see Brewer et al 2013) Published TPH Toxicity Factors Massachusetts DEP (1990s) TPH Working Group (1990s) USDHHS (1999) Washington DOE (2006) California EPA (DTSC 2009) USEPA (2009) 6 Reasonably similar except C5- C8 aliphatics; Several states publish risk- based screening levels for TPH; Massachusetts, California and Hawai’i have TPH indoor air and soil gas screening levels for PVI (others?).

C2 C4 C6 C8 C12 C16C20C24 C28 C32 C36 C0 *USEPA Inhalation Toxicity Factors for Vapor-Phase Carbon Ranges C5-8C9-18 C9-16 RfC = 600 µg/m 3 Gasolines Middle Distillates Fuel Oils More Toxic TPH = Sum of Aliphatics + non-targeted Aromatics (e.g., BTEXN) 7 Aliphatics Aromatics RfC = 100 µg/m 3 *As used in Hawai’i guidance Number of Carbon Atoms in Compounds

TPH Carbon Range Screening Levels (HDOH 2011 EALs, Appendix 1) 1. After USEPA 2009 (see 2011 HDOH EAL guidance). 2. Based on USEPA RSL ambient air exposure model. 3. Residential vapor intrusion screening level, based on an assumed attenuation factor of (Indoor Air:Subslab Soil Vapors). 8 Carbon Range 1 Reference Concentration (µg/m 3 ) 2 Indoor Air Screening Level (µg/m 3 ) 3 Subslab Vapor Screening Level (µg/m 3 ) C5-C8 Aliphatics ,000 C9-C18 Aliphatics ,000 C9-C16 Aromatics ,000

Calculation of Total TPH Screening Levels (based on assumed carbon range makeup of vapors; HDOH 2011) 9 Odor Recognition: Gasoline: 750+ ug/m 3 Diesel: 3,500+ ug/m 3 Default Gasoline Vapor Composition *highly variable Weighted RfC= 571 ug/m 3 Indoor Air res = 600 ug/m 3 Soil Gas res = 600,000 ug/m 3 *Weighted RfC= 126 ug/m 3 Indoor Air res = 130 ug/m 3 Soil Gas res = 130,000 ug/m 3 Assumed Subslab-Indoor Air AF = *Default Diesel Vapor Composition

Fact #4: *TPH Can Drive PVI Risk if Sufficiently Dominant Over Benzene (see Brewer et al 2013) 1. *TPH could still pose a PVI risk even though benzene meets screening level; 2. Ratio of TPH:Benzene at which TPH will drive risk depends on TPH composition. Less TPH required if dominated by higher toxicity C9-C12 aliphatics; More TPH required if dominated by lower toxicity C5-C8 aliphatics TPH:Benzene “Critical” RatioVapor Intrusion Risk Driver >2,000:1 TPH will always drive vapor intrusion risk (TPH HQ >1.0 even though benzene ECR <10 -6 ) 300:1 to 2,000:1 2 TPH could drive vapor intrusion hazards (depends on carbon range makeup) <300:1 Benzene will always drive vapor intrusion risk. (assuming screening level = 0.31 µg/m 3 )

TPH Drives PVI Risk Over BTEXN at Diesel and Low-Benzene Gasoline Sites HDOH Field Study Site/Fuel Type Vapor Intrusion Risk Driver 1 TPH: Benzene 1 Benzene Drives Risk 2 TPH Drives Risk Gasoline (Fresh Vapors)170 X Diesel (Fresh Vapors)206 X JP-8 (Fresh Vapors)301 X Site A (JP-4/AVGAS?)1,513XX Site B (mixed fuels)4,174 X Site C (JP-8 +/- JP-4)18,710 X Site D (low-benzene gasolines)9,135 X Site E (diesel)18,611 X HDOH field study (see Brewer et al 2013).

12 *Weighted RfC= 275 µg/m 3 Indoor Air res = 290 µg/m 3 Soil Gas res = 290,000 µg/m 3 Med TPH:Benzene = 300:1 *Average of 35 samples from 10 sites included in database; Critical TPH:Benzene Ratio=900:1; TPH could drive risk over benzene for 33% of database samples; Gasoline vapors more toxic that HDOH default (see HDOH 2011; Brewer et al 2013); Possible mix of diesel or kerosene vapors at some sites (high C9-C12 aliphatics)? USEPA PVI Database (gasoline vapors targeted) Average TPH Vapor Makeup and Toxicity Residential screening levels (assuming subslab AF = 0.001)

13 Fact #5: Higher Aliphatic Degradation Rate vs Aromatic Degradation Rate Not Supported by Field Data (predicted relative TPH depletion in vapors away from source not observed ) TPH:BTEX = 13,000:1 TPH:BTEX = 5,500:1 TPH:BTEX = 3,500:1 TPH:BTEX = 3,000:1 AECOM 2012 X-Section Gasoline UST Release Five Feet Models (e.g., Biovapor) predict aromatics removed at faster rate than aliphatics; Opposite seen in field. TPHg in Soil Vapor

14 Fact #6: Default 15ft PVI Separation Applies to TPH (USEPA & ITRC PVI guidance) Weighted RfC= 308 µg/m 3 Indoor Air res = 320 µg/m 3 Soil Gas res = 320,000 µg/m 3 TPH:Benzene = 6,700:1! TPH drives PVI risk AECOM 2012 TPH = 99,000,000 µg/m 3 TPH: 18,000,000 µg/m 3 TPH = 310,000,000 µg/m 3 TPH = 140,000,000 µg/m 3 TPHg in Soil Vapor Five Feet X-Section Gasoline UST Release Field Data: TPH vapors exceed screening levels ft above source; Models can underestimate TPH migration.

Subslab Soil Vapor: McAlary, T.A., Nicholson, P.J., Yik, L.K., Bertrand, D.M. and G. Thrupp High Purge Volume Sampling—A New Paradigm for Subslab Soil Gas Monitoring: Groundwater Monitoring & Remediation, 30: Indoor Air: H. Dawson Examples and Measures of Temporal Variability in Indoor Air Concentrations Arising from Vapor Intrusion: AWMA Annual Conference, Vapor Intrusion Panel, Raleigh, NC, June 24, 2015 (see also Dawson et al AEHS 2013) Fact #7: Bigger Samples are More Representative

Mean Indoor Air Concentration Increases as the Sample Duration and Volume Increases (Dawson 2013, 2015) hr Samples7-day Samples after Dawson 2013, 2015 Classic signal of random, intra- and inter-day variability; Assumed to be caused by temporarily higher VOC concentrations in intruding vapors; Large volume and long duration samples required to capture variability, estimate daily mean and assess risk.

Targeted VI Exposure Duration *Equivalent Volume of Intruding Vapors Chronic (30 years)75 million liters Chronic (6 years)15 million liters Sub-Chronic (3 months)650 thousand liters Acute (14 days)100 thousand liters Acute (1 day)7,000 liters Acute (1 breath, 5 secs)2-4 liters *Assuming USEPA default vapor entry rate of 5L/minute for a 100m 2 residential home. Are Traditional Subslab Soil Vapor Samples Representative of Intruding Vapors and VI Risk?

Assumes collection from upper 15cm of fill under slab & 30% porosity; Small-volume sample data not reliably representative of subslab vapor plume; Less frequent, higher concentration areas of vapor plume likely to missed and mean VOC concentrations underestimated; Larger volume samples required to more reliably assess vapor intrusion risk. Probably Not… “Discrete” soil vapor samples are Too SMALL ! Vapor Plume Map Area Covered by Traditional “Discrete” Vapor Samples

HDOH Proposed Subslab Vapor Plume Characterization Study (pending, July 2016) Problem: Reliability of small number of small-volume, “discrete” vapor samples to characterize subslab vapor plumes unknown; Magnitude of random, small-scale variability around discrete sample points unknown; Testing of large numbers of subslab vapor samples not financially practical; Causes uncertainty of vapor intrusion investigations. Study Design: Overall: Use tight grid of passive subslab vapor samples to identify large-scale, subslab vapor plume patterns and target area for High Purge Volume sampling; Divide targeted slab area in grid cells for collection of passive soil vapor samples; Install four passive samplers in each cell and combine at lab for testing; Install triplicate sets of passive samples in three cells to test field precision of data; Install nine passive samplers in one cell to test small-scale variability; Collect HPV sample in identified hot area of vapor plume; Continuous monitoring of purge stream using a mobile gas chromatograph. Study Objectives: Evaluate number of passive samplers required to identify large-scale patterns; Assess data precision and reliability, ease and cost of implementation, etc.; Evaluate potential for artificial “cold spots” and “hot spots” in existing discrete sample data sets due to small-scale, random vapor concentration variability; Evaluate use of HPV samples to better represent targeted areas of subslab vapors.

The Search for More Representative Data HDOH Proposed Subslab Vapor Plume Characterization Study (former dry cleaner; pending, July 2016)

Former Dry Cleaner Honolulu, Hawaii Target Subslab Area (95’ x 95’ square, slab intact and in good condition)

Former Dry Cleaner 2002 Passive Soil Vapor Data PCE TCE Target Subslab Area

Former Dry Cleaner 2016 Active Soil Vapor Data PCE 1,710 µg/m 3 PCE 45,000 µg/m 3 PCE 188,000 µg/m 3 PCE 9,560 µg/m 3 PCE 108,000 µg/m 3 HDOH C/I Subslab Vapor Action Level PCE: 1,400 µg/m 3 PCE 53,300 µg/m 3 Subslab Data 3-5’ bgs Data PCE 108,000 µg/m 3 PCE 38,900 µg/m 3 PCE 50,100 µg/m 3 PCE 6,750 µg/m 3 Apparent high-concentration vapor plume under entire slab; Neither data set adequately representative; No clear pattern in VOC concentrations; Sample points too few points and/or sample volume too small.

Subdivide Slab Area into Grid Cells for Higher-Resolution Characterization PCE TCE Target Subslab Area

PCE 1,710 µg/m 3 PCE 45,000 µg/m 3 PCE 188,000 µg/m 3 PCE 9,560 µg/m 3 PCE 108,000 µg/m 3 HDOH C/I Subslab Vapor Action Level PCE: 1,400 µg/m 3 PCE 53,300 µg/m 3 Subslab Data 3-5’ bgs Data PCE 108,000 µg/m 3 PCE 38,900 µg/m 3 PCE 50,100 µg/m 3 PCE 6,750 µg/m 3 Subdivide Slab Area into Grid Cells for Higher-Resolution Characterization

Carry out High-Resolution Passive Sampler Survey 25 Grid Cells Subslab Soil Vapor Samples Divide slab area into 25 grid cells; Install four passive samplers in each cell (address variability); Combine samplers for testing to generate a single value for each grid cell; Use results to identify large-scale vapor plume patterns under slab; Replicate sample sets collected in three cells to test field precision; Multiple single samples collected on one cell to test small-scale variability. Replicate Sample Cells Small-Scale Variability Cell

Replicate Sample Sets Replicate Sample Collection Collect replicate sample sets (triplicates) in grid cell located in highest anticipated VOC area; Install three passive samplers in each of four subcells (e.g., sets “A,” “B,” and “C;” approx. 5ft spacing); Combine samplers for each replicate set for individual analyses (total three analyses per grid cell); Calculate RSD to assess precision of data. Replicate Sample Design A B C A B C A B C A B C Test of Reproducibility of Grid Cell Data

Multiple Single Samples Small-Scale Variability Sample Design Test of Small-Scale Variability Within Grids Small-Scale Variability Install and individually test nine evenly spaced, passive samplers in one grid cell; Evaluate variability in data to assess representativeness of data for single sample points.

Identify Large-Scale Concentration Patterns (hypothetical results indicated) Hot Area Identified Subslab Soil Vapor Samples Assign passive sample data results to appropriate grid cell; Identify apparent, large-scale patterns in subslab vapor concentrations (hypothetical “hot area” shown); Use to target HPV sample collection. Beacon Passive samplers:

Collect High Purge Volume Vapor Sample (e.g., from highest concentration area) HPV Sample Collected Beacon Passive samplers: High Purge Volume Sample (example) Single, HPV subslab vapor sample collected from identified vapor high- concentration under slab; 30ft radius Vapor plume DU area targeted (estimated 25,000 liters air- filled pore space in upper 12” assuming 30% porosity); Area of influence uncertain - controlled variability in vapor permeability, preferential pathways, etc.; Objective: Mimic hypothetical vapor entry HPV point over 24 hours; Single, 7,000 liter (?) HPV subslab vapor purge; Triplicate 6L summa samples collected during purge to test data precision. ? ? ? ?

How to Collect a Really BIG and Really REPRESENTATIVE Subslab Vapor Sample (McAlary et al 2010) 31 Able to purge 100s to 1,000s liters of subslab vapor (1-3,000 liters/min); Samples collected from purge/slip stream using 6L Summas; Target purge and summa collection time 30 minutes? Equates to purge rate in the low 100s L/minute for a 5,000L draw; Pretest, monitor and limit purge/sampling vacuum to < 7” Hg ; Avoid downward leakage of outdoor air into slab and dilution of vapor stream. Collect triplicate, 6L summas to test HPV data precision and reproducibility

Continuous Monitoring of Purge Stream 32 Portable gas chromatograph to be used for continuous monitoring of purge stream and/or collection of multiple samples during purging; Data used to further evaluate small-scale heterogeneity of VOC concentrations in subslab vapor plumes.

Total Sample Collection and Analysis 1. Passive Samplers: 2. Active HPV Summa Samples: Three 6L Summas; Three TO-15 analyses; 3. Mobile GC monitoring of HPV slip stream. Grid Cell Type # of Cells Passive Samplers Per Cell Total Samplers Deployed Analyses Per Cell Total AnalysesSample Type Standard: pt composite Replicates: pt composite Variability:19999 single sampler Total:25Total:129Total:39

Summary of PVI Facts and Path Forward 1.Middle distillate fuels like diesel and jet fuel are volatile; 2.Petroleum vapors are dominated by TPH aliphatics; 3.Risk-based indoor air and soil gas action (screening) levels can be developed for TPH; 4.Benzene likely to drive PVI risk at high-benzene (e.g., pre-2005) gasoline release sites, but TPH likely to drive PVI risk at low- benzene gasoline sites and all middle distillate sites; 5.TPH does not degrade faster than BTEX (possibly reverse); 6.A minimum 15ft PVI separation distance is appropriate for TPH; 7.Large-volume indoor and air soil vapor samples required to capture and represent small-scale vapor plume heterogeneity: Designation of Decision Unit area and volume of soil vapor plume for sample collection is important (sampling theory); Use High Purge Volume sampling method to collect representative vapor sample from targeted DU and assess PVI risk; Attempts to use small-volume (e.g., 50ml) samples to identify “acute” hot spots unreliable and misleading. 34

Questions? Think BIGGER !