Introduction Lei, Yang; Luo, Ning. A highly sensitive electrochemical biosensor based on zinc oxide nanotetrapods for L-lactic acid detection. Nanoscale,

Slides:



Advertisements
Similar presentations
Thin Film Cyclic Voltammetry
Advertisements

Ruizhen Li School of Chemistry and Environment South China Normal University Guangzhou China Study on Lead Based Rare Earth Alloys for Positive Grids of.
EEE 529 Microsystems Amperometric Biosensors
On-line Glucose Measurement in Disposable Bioreactors Michael Hartlep and Wolfgang Künnecke INTRODUCTION The use of disposables in biopharmaceutical processes.
Hydrogen Peroxide Detection Using Biogenic and Synthetic MnO 2 Shu Feng, Jim Nurmi, Paul Tratynek Satya Chinni, Brad Tebo Department of Environmental and.
Microfluidic Glucose Sensor Senior Design Group 4 Kristen Jevsevar Jason McGill Sean Mercado Rebecca Tarrant Advisor: Dr. John Wikswo, Dr. David Cliffel.
Yat Li Department of Chemistry & Biochemistry University of California, Santa Cruz CHEM 146C_Experiment #8 Surface Electrochemistry: Adsorption of Polyoxometalate.
New electrode materials for H 2 O 2 New electrode materials for H 2 O 2 based sensors and biosensors Francesco Ricci 1, Carla Gonçalves 2, Giuseppe Palleschi.
VOLTAMMETRY A.) Comparison of Voltammetry to Other Electrochemical Methods 1.) Voltammetry: electrochemical method in which information about an analyte.
Abstract Sibley School of Mechanical and Aerospace Engineering, Cornell University Researchers from Cornell University and the Cornell Lab of Ornithology.
Fabrication of a Microelectrode Array Biosensor Based on a Modified Enzyme-Chitosan Biocomposite Lorenzo D’Amico October 1, 2008.
Dr. Marc Madou, UCI, Winter 2012 Class V Potentiometric and Amperometric Sensors (I) Electrochemistry MAE-295.
Introduction Silver(I) Oxide-Graphene Oxide Sensor for Hydrogen Peroxide Austin Scherbarth, Professor Lia Stanciu, Alexandra Snyder, Isabella Ramirez School.
Durability of Carbon Nanofiber & Carbon Nanotube as Catalyst Support for Proton Exchange Membrane Fuel Cells Shuang Ma Andersen 1, Peter Lund 2, Yli-Rantala.
The Detection of Hydrogen Peroxide and Glucose for the Electrode Modified with Ferrocene Yi-Sheng Wang ( 汪乙生 ), Ting-Li Lin ( 林庭立 ), Hau Lin ( 林浩 ) Department.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 15 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
基于纳米金和硫堇固定酶 的过氧化氢生物传感器 答辩人:陈贤光( 03 应化) 指导老师:童叶翔 教授 邹小勇 教授 广州.
NSF-ITR Meeting Miniaturized Sensors Air molecules aerosols Water molecules cells, viruses.
Carbon Nanotubes as Biosensors ME 695 Yang 11/30/2004.
The Redox Behaviour of Diazepam (Valium®) using a Disposable Screen- Printed Sensor and Its Determination in Drinks using a Novel Adsorptive Stripping.
Professor: Cheng-Ho Chen Student: Ying-Chen Lin Date: 2015/01/21.
Preparation of the Carbon Paste Electrode Modified with Ferrocene and Its Applications to Detection of Hydrogen Peroxide and Glucose Yi-Sheng Wang ( 汪乙生.
Norhayati Soin 06 KEEE 4426 WEEK 3/2 13/01/2006 KEEE 4426 VLSI WEEK 3 CHAPTER 1 MOS Capacitors (PART 2) CHAPTER 1.
A Study of the Effect of Operating Potential on Detection of Hydrogen Peroxide for the Electrode Modified with Ruthenium Hexacyanoferrate Kuo-Hsiang Liao.
NOVEL NON-CONDUCTING FILMSFOR INTERFERENCE-FREE ELECTROCHEMICAL SENSORS M. BADEA a, A. CURULLI b*, G. PALLESCHI a, S. KACIULIS c, A. MEZZI c a Università.
CAREER: Inorganic Nanoparticles with Biological Properties: Preparation, Characterization and Sensing Applications E. Silvana Andreescu, Clarkson University,
A Study of Statistical Analysis of the Main Effects and Interaction Effects of Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with.
Chemiluminescence. Luminescence Definition Luminescence is emission of light by a substance not resulting from heat Types of luminescence Fluorescence.
The Optimum Operating Conditions for Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財 ), Chung-Min.
An Analysis of the Effects of Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財 ), Chung-Min Lien.
The Operating Potential on the Sensitivity of Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財.
Microwave Assisted ZnO Nanorod Growth for Biosensing This material is based upon work supported by the National Science Foundation.
The Effect of Stirring Rate on the Detection of Hydrogen Peroxide for Carbon Paste Electrode Modified with Meldola’s Blue Chi-Wen Lo ( 羅濟玟 ), Chih-Ying.
An Analysis of Variance of Detection of Hydrogen Peroxide for Carbon Paste Electrode Modified with Copper Hexacyanoferrate Chia-Cheng Hsiao ( 蕭佳政 ), Chih-Ying.
The Detection of Glucose for the Carbon Paste Electrode Modified with Ruthenium Hexacyanoferrate Kuo-Hsiang Liao ( 廖國翔 ), Chih-Ying Wu ( 巫致穎 ), Hau Lin.
The Operating Conditions for the Sensitivity of Detection of Hydrogen Peroxide for the Electrode Modified with Copper Hexacyanoferrate Chia-Cheng Hsiao(
A.) Introduction : 1.) Coulometry: electrochemical method based on the quantitative oxidation or reduction of analyte - measure amount of analyte by measuring.
Application of the Screen Printed Planar Electrode Modified with Ruthenium Hexacyanoferrate to Glucose Biosensor Kuo-Hsiang Liao( 廖國翔 ), Chung-Min Lien(
Section 13 Analytical Voltammetry.
The Effect of Ratio of Meldola’s Blue to Carbon Powders and Carbon Paste on Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with.
BIOFABRICATION OF MEA GLUCOSE SENSORS Dry in air Ready for in vitro glucose detection (B) Chitosan biopolymer is electrodeposited on target electrode sites;
The pH on the Sensitivity of Detection of Hydrogen Peroxide for the Small Electrode Modified with Meldola’s Blue Chi-Wen Lo ( 羅濟玟 ), Chung-Min Lien ( 連崇閔.
The pH on the Detection of Hydrogen Peroxide for Electrode Modified with Chromium Hexacyanoferrate Chen-Hsun Hu ( 胡真熏 ), Ting-Li Lin ( 林庭立 ), Hau Lin (
Microfluidic Glucose Sensor Senior Design Group 4
Introduction. During the last decade the interest in copper passivity significantly increased due to the important role of copper in microelectronic industry.
The Detection of Hydrogen Peroxide and Glucose for the Electrode Modified with Ruthenium Hexacyanoferrate Kuo-Hsiang Liao ( 廖國翔 ), Chung-Min Lien ( 連崇閔.
Advanced Biosensors Based on Nano-scaled Arrays and Films of Electro- and Biocatalysts Arkady A. Karyakin Chemistry faculty of M.V. Lomonosov Moscow State.
A Study of Carbon Paste Electrode Modified with Platinum Particles and Ferrocene and Its Application to Glucose Biosensor Yi-Sheng Wang ( 汪乙生 ), Ting-Li.
Biosensors Dr. Bhavesh Patel Principal
Abstract Results Current Time PO4 Addition Points Development of a Phosphate Biosensor for Soil & Groundwater Serkan Akar*, Vekalet Tek*, Adam Bange#,
Introduction to Electroanalytical Chemistry
M. M. Khalil, S. M. Mostafa, and A. A. Masoud  Scholars Report 
Analytical Laboratory II
/ CHEMICAL CROSS TALK STUDIES ON A MICROPROBE ARRAY BASED CONTINUOUS GLUCOSE MONITORING SENSOR Sanjiv Sharmaa,
Electrochemistry MAE-212
Biosensors Definition
RESULTS AND DISCUSSION
Chen-Hsun Hu (胡真熏) , Chih-Ying Wu (巫致穎) , Hau Lin (林浩)
Fabrication of glass/ITO/PANI-LS Electrodes
Preparation of Surface for Biomolecule Immobilization
Photovoltaic Systems Engineering
NiO2 mediator in catalytic oxidation of 2-propanol on glassy carbon
s Changes: Cite figures under EIS
نانو زیست حسگرها (1) اصول عملکرد و طبقه بندی
Joy Qiu ♦ Dr. Greg Swain ♦ HSHSP 2014
Spark Plasma Sintering of Ceria Materials for Solid Oxide Fuel Cells Applications Lia Stanciu, School of Materials Engineering, Purdue University, West.
Photovoltaic Systems Engineering
Chapter Fifteen VOLTAMMETRY AND ELECTROCHEMICAL SENSORS
Cyclic Voltammetry Dr. A. N. Paul Angelo Associate Professor,
Structure and electrochemical function of impedimetric biosensors for bacterial detection. Structure and electrochemical function of impedimetric biosensors.
Presentation transcript:

Introduction Lei, Yang; Luo, Ning. A highly sensitive electrochemical biosensor based on zinc oxide nanotetrapods for L-lactic acid detection. Nanoscale, 2012, 4, Njagi, John; Ispas, Cristina; Andreescu, Silvana. Mixed ceria-based metal oxides biosensor for operation in oxygen restrictive environments. Analytical Chemistry, 2008,90,19, Rodriguez, M.; Rivas, G. Assembly of Glucose Oxidase and Different Polyelectrodes by Means of Electrostatic Layer-by-Layer Adsorption on Thiolated Gold Surface. Electroanalysis. 2004, 16, No. 20. Wiley Publishers. Lei, Yang; Luo, Ning. A highly sensitive electrochemical biosensor based on zinc oxide nanotetrapods for L-lactic acid detection. Nanoscale, 2012, 4, Njagi, John; Ispas, Cristina; Andreescu, Silvana. Mixed ceria-based metal oxides biosensor for operation in oxygen restrictive environments. Analytical Chemistry, 2008,90,19, Rodriguez, M.; Rivas, G. Assembly of Glucose Oxidase and Different Polyelectrodes by Means of Electrostatic Layer-by-Layer Adsorption on Thiolated Gold Surface. Electroanalysis. 2004, 16, No. 20. Wiley Publishers. The Role of Metal Oxide Layers in the Sensitivity of Lactate Biosensors Subjected to Oxygen-Limited Conditions Elizabeth Andreasen, Professor Lia Stanciu, Aytekin Uzunoglu School of Materials Engineering, Purdue University, West Lafayette, IN In-Situ Oxidative Polymerization via Spin Coating Method Results and Conclusions Future Work References Amperometric biosensors use the change in current to detect the concentration of the analyte in the medium. Lactate biosensors will improve ease in detecting athletic condition, septic shock, and cyanide intoxication. Detection depends on the oxidation of lactate, which produces H 2 O 2. The electro-oxidation of H 2 O 2 is detected on the electrode surface. Commercial amperometric sensor for hydrogen peroxide and other chemicals Biosensor construction via layer-by- layer assembly Positively charged polyethylenimine (PEI) and negatively charged lactate oxidase (LOx) Incorporation of metal oxide in the enzyme layer Results. Objectives Design an adequately sensitive and reliable sensor that can function in the absence of oxygen Examine the effect of oxygen storage capacity on the performance of the biosensor Improve the sensitivity of the biosensors Perform Electrochemical tests: Cyclic Voltammetry (CV) was conducted at 0.6 V. Lactate is introduced to the system to observe the magnitude of current change. Current response tests are repeated in an oxygen-free solution. Calibration curves are recorded by incrementally adding lactate. Sensor development with differing metal oxide solutions with varying oxygen storage capacities– Zr, Ti, Ge, Cu doped CeO 2 Improve biosensor stability Examine the surface microstructure Addition of metal oxide reduces the dependence on oxygen in the biosensor. Incorporation of CeO 2 extended the linear range. Lactate biosensors with a high sensitivity, selectivity, and wide linear range were constructed. The addition of a CeO 2 layer allows the sensor to remain sensitive in oxygen-free environments. It extends the linear range of current response to a measurable level (seen in Fig 1). Without oxygen, current response of CeO 2 coated sensors is twice that of non- CeO 2 sensors (seen in Fig 2). Figure 1 shows the comparison of sensitivity for sensors in an oxygen-free environment as a small, fixed amount of lactate is added incrementally. Figure 2 shows the increased response of Ceria coated sensors in an oxygen-free environment. A platinum electrode used for lactate sensing. Figure 3 shows the linear current response trend in oxide coated electrodes when oxygen is absent.