Beyond the workshop: Developing inter-calibration products based on Lunar Observations Tim Hewison (EUMETSAT) [GSICS Research Working Group Chair] Special.

Slides:



Advertisements
Similar presentations
GSICS Bias Monitoring Routine comparisons of satellite radiances against reference GSICS Correction Function to correct issued radiances For consistent.
Advertisements

Radiometric Calibration PROBA-V QWG #2. PRESENTATION OUTLINE »Introduction »Stability of PROBA-V »ICP updates since QWG#1 »Outlook »Moon calibration GSICS.
Use of the Moon as a calibration reference for NPP VIIRS Frederick S. Patt, Robert E. Eplee, Robert A. Barnes, Gerhard Meister(*) and James J. Butler NASA.
CGMS-42, May 2014, Guangzhou, China Coordination Group for Meteorological Satellites - CGMS GLOBAL SPACE-BASED INTER-CALIBRATION SYSTEM (GSICS) CGMS-42-WMO-WP22.
1EUM/RSP/VWG/16/ Tim Hewison Tom Stone Manik Bali Selecting and Migrating GSICS Inter-Calibration Reference Instruments.
1EUM/RSP/VWG/16/ Tim Hewison Tom Stone Manik Bali Selecting and Migrating GSICS Inter-Calibration Reference Instruments.
Agency xxx, version xx, Date xx 2016 [update in the slide master] Coordination Group for Meteorological Satellites - CGMS Introduction to GSICS Presented.
World Meteorological Organization Working together in weather, climate and water WMO OMM WMO A WMO perspective on GSICS Joint Meeting of the.
Recommendations to GSICS from international working groups GSICS meeting, March 2015, New Delhi, India Rob Roebeling.
June, GSICS USER GUIDE Using GSICS Products and Services Manik Bali, Tim Hewison, Larry Flynn and Jerome Lafeuille 2016 GSICS Executive Panel Meeting.
GSICS Coordination Center Report Fangfang Yu, Fuzhong Weng, Fred Wu and George Ohring NOAA/Center for Satellite Applications and Research 8 April, 2013.
1.Bob Iacovazzi (NOAA) - Road to Pre-operational Phase Presentation 2.All – Discussion & Feedback 3.Tim Hewison (EUMETSAT) – Reminders: Korea, Conference,
NOAA GPRC Report 2013 GSICS Annual Meeting Williamsburg, VA 03/04/ /08/2013.
Beyond the workshop: Developing inter-calibration products based on Lunar Observations Tim Hewison (EUMETSAT) [GSICS Research Working Group Chair] Special.
Thomas C. Stone U.S. Geological Survey, Flagstaff, AZ USA GSICS Research Working Group Meeting EUMETSAT 24−28 March 2014 Using the Moon as a Radiometric.
GRWG ON THIN ICE? Presentation by Tim Hewison CONTAMINATION EFFECTS ON METEOSAT/SEVIRI CALIBRATION TIM HEWISON, JOHANNES MÜLLER, REBECA GUTIERREZ.
PLEIADES Lunar Observations Sophie Lachérade, Bertrand Fougnie
Description of the giro ON THE DETAILS OF THE IMPLEMENTATION
PREPARATION OF THE GiRO executable
Introducing Me, GSICS, and the UV Sub-Group
Calibrating the METEOSAT SEVIRI solar channels using lunar observations Sébastien Wagner (1) Bartolomeo Viticchie (1), Tom Stone (2), Tim Hewison(1), Gary.
GRWG VIS/NIR Sub-Group Briefing Report
Lunar Calibration Workshop Activities
Second Joint GSICS-IVOS Lunar Calibration Workshop
Sébastien Wagner, Tim Hewison In collaboration with D. Doelling (NASA)
Workshop on best practices on pre-flight and onboard calibration
Doelling, Wagner 2015 GSICS annual meeting, New Delhi March 20, 2015
GSICS SEVIRI-IASI Inter-Calibration Uncertainty Evaluation Tim Hewison1 The regression propagates these variances to estimate the uncertainty on the corrected.
The ROLO Lunar Calibration System Description and Current Status
Lunar Calibration activities
Report of GRWG: Review of Actions & Web meetings
Update on Advancing Development of the ROLO Lunar Calibration System
Jo Schmetz1 on behalf of Tim Hewison1 EUMETSAT
Closing the GEO-ring Tim Hewison
A Strategy for the Inter-Calibration of Solar Channels within GSICS
Update on the GIRO Benchmark
Use of NWP+RTM as inter-calibration tool
Sensitivity ANALYSIS Sébastien Wagner (EUMETSAT) In collaboration with
Tim Hewison1 (1) EUMETSAT
Contribution to Agenda Item 8
Ongoing need for Re-Analysis Corrections? Tim Hewison
Combination Approaches
Update on GSICS Product Development
Moving toward inter-calibration using the Moon as a transfer
Infrared Inter-Calibration Product Announcements
Sensitivity ANALYSIS Sébastien Wagner (EUMETSAT) In collaboration with
Strategy for calibration references
Inter-calibration of the SEVIRI solar bands against MODIS Aqua, using Deep Convective Clouds as transfer targets Sébastien Wagner, Tim Hewison In collaboration.
Special Issue of the IEEE TGRS on “Inter-Calibration of Satellite Instruments”: 01 January 2019 Report of GRWG: Aims of meeting Review of Actions Proposal.
Developing Spectral Corrections / SRF Retrievals Tim Hewison
Strategy for calibration references
Technical aspects of the GIRO work: inputs from GRWG
Status of the EUMETSAT GSICS DCC product
Current Status of ROLO and Future Development
Moving toward inter-calibration using the Moon as a transfer
Progress toward DCC Demo product
Hot summary of the Fourth GSICS Users Workshop
Inter-band calibration using the Moon
Formation of IR Sub-Group and Reference Selection
Tim Hewison1 and all GSICS Developers EUMETSAT
Discussion on Solar Spectra for Vis/NIR Calibrations
S3B OLCI Lunar Observations
Variogram Stability Analysis
Infrared Sub-Group Report Tim Hewison
Ideas for NRT Microwave Imager inter-calibration products
Lunar Calibration Workshop Activities
Toward a synergy between on-orbit lunar observations
Lunar Calibration Workshop Status of the preparation
How good is IASI-A as an in-orbit reference in GSICS in LWIR and IR
Towards a GSICS DCC product...
Presentation transcript:

Beyond the workshop: Developing inter-calibration products based on Lunar Observations Tim Hewison (EUMETSAT) [GSICS Research Working Group Chair] Special Issue of the IEEE TGRS on “ Inter-Calibration of Satellite Instruments ” :

Slide: 2 Overview Introduction to GSICS Scoping Lunar Inter-Calibration products Choice of Reference Instrument Error Budgets Key Issues – Phase Angle-Dependence – Spectral Consistency Moving Forward

Slide: 3 Global Space-based Inter-Calibration System What is GSICS? –Global Space-based Inter-Calibration System –Initiative of CGMS and WMO –Effort to produce consistent, well-calibrated data from the international constellation of Earth Observing satellites What are the basic strategies of GSICS? –Improve on-orbit calibration by developing an integrated inter-comparison system Initially for GEO-LEO Inter-satellite calibration Being extended to LEO-LEO Using external references as necessary –Best practices for calibration & characterisation This will allow us to: –Improve consistency between instruments –Reduce bias in Level 1 and 2 products –Provide traceability of measurements –Retrospectively re-calibrate archive data –Better specify future instruments EUMETSATCNESJMA NOAACMAKMA ISRONASAWMO USGSNISTJAXA ROSHYDROMETIMDESA

Slide: 4 GSICS Organisation GSICS Exec Panel GSICS Coordination Center GSICS Research Working Group VIS/NIR Sub-Group WGCV IVOS Microwave Sub-Group WGCV MWSGGPM X-CAL UV Sub-Group WGCV ACSGCEOS ACC Future Sub-Groups... GSICS Data Working Group CGMSWMO Identified potential collaborations with CEOS

Slide: 5 GSICS Principles TRACEABILITY / UNBROKEN CHAINS OF COMPARISONS Systematic generation of inter-calibration products for Level 1 data from satellite sensors to compare, monitor and correct the calibration of monitored instruments to community references by generating calibration corrections on a routine operational basis with specified uncertainties through well-documented, peer-reviewed procedures based on various techniques to ensure consistent and robust results Delivery to users Free and open access Adopting community standards To promote Greater understanding of instruments’ absolute calibration, by analysing the root causes of biases More accurate and more globally consistent retrieved L2 products Inter-operability for more accurate environmental, climate and weather forecasting products

Slide: 6 GSICS Bias Monitoring Routine comparisons of satellite radiances against reference GSICS Correction Function to correct issued radiances for consistent calibration with reference GSICS Calibration Alternative Calibration Coefficients = operational calibration + inter-calibration corrections GSICS Reports & Guidelines Recommendations to modify processing/practices Design and Operation of future satellite instruments For Operational Environmental Satellites Infra-red recalibration (GEO and LEO) Pre-Operational & Demo status (current operational satellites) Near real-time and re-analysis Visible and near-infrared recalibration (GEO and LEO) In development within GSICS Microwave – Conical & Cross-track Scanners (LEO) In development with GPM XCAL Historic Instruments In development for SCOPE-CM GSICS Product Types

Slide: 7 Scoping GSICS Lunar Inter-Calibration Products Double differences of irradiances from monitored and reference instruments, w.r.t. a model: (I MON -I mod )-(I REF -I mod ) – Assumption: Model errors will cancel out (linearity) – No need to adjust to absolute scale In general: Correction=Polynomial function of Radiance, ΔL=g(L MON ) – Simplest case: Linear scaling of operational gain Allow GSICS Corrections to vary with time – To track calibration drifts of monitored instrument – Defined from combination of data over extended period with negligible drift

Slide: 8 Future Extensions to GSICS Lunar Inter-Calibration Products Combine with other methods – Aim to provide users ONE product – For all VIS/NIR/SWIR channels – Cover full dynamic range (linearity) – e.g. DCC + Lunar – Optimal combination weighted by uncertainty of each method Spectral consistency – Inter-channel Bias Matrix Tie to absolute standards – SI Traceability Lunar Disc Reflectance Range

Slide: 9 Choice of Inter-Calibration Reference Common primary reference for all GSICS Products in Reflected Solar Band Initially, Aqua/MODIS – For all channels? Migration to Other Reference Instruments – e.g. SNPP/VIIRS – Handled using concept of delta Corrections – Developed for GEO-LEO IR – Based on double-difference of different inter-calibration products – Ensures traceability back to primary reference – Ensures radiometric consistency – Eventually hyperspectral reference instruments? TBC! Needs robust and consistent uncertainty estimates – Both on observed and modelled irradiances

Slide: 10 Error Budgets Needed for comparison and optimal combination of – Observed Irradiances – Modelled Irradiances Construct Error Budget (Type B evaluations) for uncertainties due to – Systematic Biases – Random Errors Based on sensitivity analysis of – GIRO inputs – Observed Irradiance Calculation Validate Error Budgets (Type A evaluations) – For Systematic Parts – by comparison between different instruments – For Random Parts - By repeated evaluations over range of conditions (and time!) Need to repeat analysis for new ROLO versions

Slide: 11 Previously on this Channel... From 2014 GRWG Annual Meeting: – Sophie Lacherade (CNES) “Moon synergy" 3mb3mb Uncertainties for Moon cross-calibration due to the lack of correct spectral interpolation between PHR and MODIS (cross-calibration limited to a band-to- band cross-calibration) Estimation of the interband accuracy based on Moon acquisitions ≈ 3% – Tom Stone (USGS) “Using the Moon as Cross-Calibration reference” 3n3n Xiong et al., “Comparison of MODIS and PLEIADES Lunar observations” Proc. SPIE 9241Proc. SPIE 9241 calibration differences between MODIS and PLEIADES are general less than 2% with an exception of about 3% for the NIR channel

Slide: 12 Key Issues Solar Variability – Impact on time series comparisons Phase Angle Dependence – Quantify uncertainty – Independently for each wavelength – Distinction from non-linearity – Distinction from stray light Spectral Consistency – Investigate Different possible spectral interpolation methods – Including Apollo sample smoothing – Quantify uncertainty – Inter-channel Bias estimation Implement improvements of ROLO model

Slide: 13 Moving Forward Confirm what are the Key Issues? – Here by Thursday Who will investigate each of the Key Issues? – Identify on Thursday Who will generate Error Budgets? – Identify on Thursday

Slide: 14 Revised Key Issues Oversampling factor Phase Angle Dependence – Quantify uncertainty – Independently for each wavelength – Distinction from non-linearity – Distinction from stray light & Space Count Subtraction Spectral Consistency – Investigate Different possible spectral interpolation methods – Including Apollo sample smoothing – Quantify uncertainty – Inter-channel Bias estimation – Use of hyperspectral Moon observations to validate SBAFs (Hyperion?) Implement improvements of ROLO model

Slide: 15 Discussions during the workshop 1.Over-sampling: what do we mean by over-sampling? How to estimate it? 2.Cross-comparison of instruments with similar SRFs + similar illuminations conditions when viewing the Moon 3.Can we put the lunar irradiance on a absolute scale? 4.Can we think of inter-calibration and tying target instruments to a common reference? If yes, how? How do we address the spectral differences between instruments? How do we address differences in the illumination conditions between instruments?

Slide: 16 Use of hyperspectral Moon observations to validate SBAFs Calibration with ROLO accounts for instruments’ SRFs Inter-calibration using broad-band reference instrument (e.g. MODIS) Requires Spectral Band Adjustment Factor – To convert radiances from Reference to be consistent with Monitored Instrument – In general SBAF are scene-dependent Implies inter-calibration would be application- dependent – Moon irradiance spectrum relatively smooth – Are Lunar SBAFs applicable to other scenes? E.g. Similar to those for DCCs? Courtesy of Lawrence Ong

Slide: 17 Moving Forward Who will investigate each of the Key Issues? Who will generate Error Budgets?