1 MPPC Timing Resolution Akito Kobayashi Shinshu University Table of contents ・ Timing Resolution ・ Set up ・ data treatment ・ result(1) ・ result(2) ・ result(3)

Slides:



Advertisements
Similar presentations
MPPC readout electoronics
Advertisements

New test result of MPPC M.Taguchi(kyoto).
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
Photodetector Timing Resolution Burle Micro-Channel Plate Photo Multiplier Tubes (MCP-PMTs) H. Wells Wulsin SLAC Group B Winter 2005.
Kuno-Group B4 Yuuki Matsumoto A report for Graduation research Development of Trigger Board for MPPC (for MuSIC experiment) A report for Graduation research.
Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
Study of Photon Sensors using the Laser System 05/7/12 Niigata University, Japan Sayaka Iba, Editha P. Jacosalem, Hiroaki Ono, Noriko.
Calibration of the 10inch PMT for IceCube Experiment 03UM1106 Kazuhiro Fujimoto A thesis submitted in partial fulfillment of the requirements of the degree.
Development of Readout ASIC for FPCCD Vertex Detector 01 October 2009 Kennosuke.Itagaki Tohoku University.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
MPPC R&D status Kobe Univ. CALICE collaboration meeting Yuji SUDO Univ. of Tsukuba ~ contents ~ Introduction Linearity curve Recovery time.
GLD Calorimeter Status Oct 学術創成会議 S. Uozumi Shinshu University FJPPL meeting held at the end of September. Preparation underway toward the ECAL.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
1. DESY tests 2. Electronics developments 3. Optical developments 4. Outlook Casablanca J. Cvach, CALICE Coll. meeting.
MPPC update including plastic connector T2K experiment collaboration meeting 2007/4/18 (Wed) S.Gomi T.Nakaya M.Yokoyama ( Kyoto University ) T.Nakadaira.
R&D of MPPC for T2K experiment PD07 : Photosensor Workshop /6/28 (Thu) S.Gomi T.Nakaya M.Yokoyama H.Kawamuko ( Kyoto University ) T.Nakadaira.
Study of the MPPC performance - R&D status for the GLD calorimeter readout – Nov 6-10.
Dec LED monitoring system Beam-test LED monitor Jan /23/200 7 K.Toyama, H.Ono Niigata University, MSU-IIT GLD-CAL.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)
Study of the MPPC for the GLD Calorimeter readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group May 29 – Jun 4 DESY Introduction.
Fine Pixel CCD for ILC Vertex Detector ‘08 7/31 Y. Takubo (Tohoku U.) for ILC-FPCCD vertex group ILC vertex detector Fine Pixel CCD (FPCCD) Test-sample.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
1 MPPC update S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira (KEK) Nov KEK.
Study of the MPPC for the GLD Calorimeter readout Satoru Uozumi (Shinshu University) Feb Beijing Introduction Basic performances Future.
R&D status of the Scintillator- strip based ECAL for the ILD Oct LCWS14 Belgrade Satoru Uozumi (KNU) For the CALICE collaboration Scintillator strips.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
MPPC Saturation Corection Idea -> how to do. MPPC Gain measurement To apply saturation correction to the beam data, all MPPC are needed to be calibrated.
Performance of SiPM Ryuhei Nakamura (Kobe Univ.) GLC calorimeter group (KEK, Kobe, Konan, Niigata, Shinshu, Tsukuba) Contents ・ Introduction ・ Test results.
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group (KNU, Kobe, Niigata, Shinshu, ICEPP.
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
DESY BT analysis - MPPC Saturation Correction - S. Uozumi Feb Sci-ECAL meeting 1.MPPC Gain Measurement (with LED data) 2.Inter-calibration of readout.
Fumihiko Ukegawa University of Tsukuba, Japan 6th Joint Korea-Japan ScEcal Meeting September 3, 2010 Kobe University Photo-sensor studies.
Time and amplitude calibration of the Baikal-GVD neutrino telescope Vladimir Aynutdinov, Bair Shaybonov for Baikal collaboration S Vladimir Aynutdinov,
Performance of new MPPC Nov. 21 Korea-Japan joint meeting Takashi Maeda Hideki Yamazaki Yuji Sudo (University of Tsukuba) --- Contents ---
D. Bertrand, J. De Bruyne, P. De Harenne, L. Etienne, S. Hannaert, G. Van Beek The Arch.
Beta-ray test for strip scintillator readout MPPC GLD Cal group KEK 06/2/28 (Tue) Niigata university Sayaka IBA.
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
ILC-CAL Test status of HPK photon sensors Kobe-U Y.Tamura / K.Kawagoe Confidential: do not distribute outside.
EAS Time Measurements P.K.Mohanty (On behalf of the GRAPES-3 Collaboration) 5 th Workshop on AstroParticle Physics, 14 – 16 December 2010 at CRL, Ooty.
PARISROC V2 Tests and Results on the TDC Sébastien Drouet – Bengyun Ky – Eric WanlinIPN Orsay.
Silicon Photomultiplier Development at GRAPES-3 K.C.Ravindran T.I.F.R, OOTY WAPP 2010 Worshop On behalf of GRAPES-3 Collaboration.
SiPM Workshop EU-FP7(HP3), Vienna, 16 Feb F.G. H.O. Study of scintillator detectors time resolution with different SiPM readout on T10 test beam.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
Development of Multi-Pixel Photon Counters (1)
The dynamic range extension system for the LHAASO-WCDA experiment
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Fast SiPM readout for PET
HELIX time of flight system electronics concepts
SiPM+NINO as a detection system for CEDAR
Multi-Pixel Photon Counter Readout Board
Времяпролетный детектор PANDA
R&D of MPPC for T2K experiment
Single photoelectron method introduce
Development of hybrid photomultiplier for Hyper-Kamiokande
MPPC for T2K Fine-Grained Detector
Study of Event Reconstruction for Saturated Pulse
R&D of MPPC in kyoto M.taguchi.
The MPPC Study for the GLD Calorimeter Readout
Performance test of a RICH with time-of-flight information
ASD-TDC joint test with MDT-CSM
Presentation transcript:

1 MPPC Timing Resolution Akito Kobayashi Shinshu University Table of contents ・ Timing Resolution ・ Set up ・ data treatment ・ result(1) ・ result(2) ・ result(3) ・ Summary and plan

2 What is Timing Resolution? Timing Resolution is timing fluctuation that MPPC signal reach to Threshold voltage. Timing Resolution is measured by TDC Threshold Voltage Timing resolution 700mV 200ns

3 Set Up Start pulse : Clock generator Stop pulse : MPPC signal MPPC type : 100,400,1600,2500pixels in 1mm*1mm MPPC bias : dV = 1.0V 100ns ×64 hamamatsu Threshold:100mV 5kHz λ~450nm V=8.5~18.5V Width = 15ns 25ps/ch

4 Set up photoMPPC MPPC LED For the plastic package MPPC sensor positions is the same for two kinds of packages. For the ceramic package 5cm 5cm

5 Treatment of data Use gauss fitting for TDC distribution, and get fluctuation parameter as sigma in fitting function. This parameter[ch] is converted to time[ps] by using TDC resolution 25ps/ch For example, sigma = →1.514ch ×25ps/ch = 38ps Set the fitting range as minimum sigma

6 plot(1) Y axis : Timing Resolution [ps] X axis : Supply voltage for LED Driver[V] ( V LED ) Example : V LED = 15V 、 sigma = 2.0ch Plot the data as X = 15 Y = 2.0*25 =50

7 result(1) If the number of pixels is large, timing resolution would be a little bit. ( =sigma would be large ) If amount of light is large, timing resolution would be better. (=sigma would be small)

8 plot(2) Y axis : timing resolution [ps] X axis : number of photon detected by MPPC(=N fired ) [p.e.] Example : V LED = 15V N fired = 4000p.e., sigma = 2.0ch ※ ADC peak = 2000ch, 1p.e.peak = 0.5ch ⇒ N fired = 2000/0.5 = 4000p.e.

9 result(2) Comparing the data of 4MPPC is difficult, because number of photon of these MPPC have big difference.

10 plot(3) Y axis : Timing Resolution[ps] X axis : Number of photon deveded by the number of pixels [p.e. / N pix ] ex : N fired = 4000p.e., sigma = 20ch at 1600pixel MPPC Plot the data as X = 4000 / 1600 = 2.5 Y = 2.0*25 = 50

11 result(3) Data points of 400pixel, 1600pixel, 2500pixel aligned except 100pixel. There is the relation without effect of number of pixels. Have to study this relation.

12 Summary Measured the timing resolution of 4 MPPCs and compared these data by using 3 kinds of plot. The results show two trends. →If the number of pixels is large, timing resolution would be a little bit. ( =sigma is large ) If amount of light is large, timing resolution would be better. (=sigma is small) X value is N fired / N pix →data points of 3 MPPC aligned. 100pixel was also linear, but didn’t align with other MPPCs.

13 Plan Study the effect of saturation for 100pixel. Study the effect of MPPC bias voltage. (dV)

14 Thank you for your attention