June 4, 2009 STAR TPC review Estimation of TPC Aging Based on dE/dx Measurements Yuri Fisyak.

Slides:



Advertisements
Similar presentations
TPC status Marian Ivanov. Outlook TPC performance ExB correction Alignment Nonlinearities and edge effects Drift velocity calibration.
Advertisements

14 Sept 2004 D.Dedovich Tau041 Measurement of Tau hadronic branching ratios in DELPHI experiment at LEP Dima Dedovich (Dubna) DELPHI Collaboration E.Phys.J.
June 6 th, 2011 N. Cartiglia 1 “Measurement of the pp inelastic cross section using pile-up events with the CMS detector” How to use pile-up.
1 Scintillating Fibre Cosmic Ray Test Results Malcolm Ellis Imperial College London Monday 29 th March 2004.
Status of  b Scan Jianchun Wang Syracuse University Representing L b scanners CLEO Meeting 05/11/02.
Algorithms and Methods for Particle Identification with ALICE TOF Detector at Very High Particle Multiplicity TOF simulation group B.Zagreev ACAT2002,
Topological D-meson Reconstruction with STAR Using the Silicon Vertex Tracker (SVT) Sarah LaPointe Wayne State University SVT review, BNL, July 7 th /8.
Chris Barnes, Imperial CollegeWIN 2005 B mixing at DØ B mixing at DØ WIN 2005 Delphi, Greece Chris Barnes, Imperial College.
Invariant Mass Calculation J/ψ Rosi Reed 3/5/08. Introduction J/ψ is the first excited state of charmonium Rest mass Gev/c 2 Full Width 93.4 keV.
FMS review, Sep FPD/FMS: calibrations and offline reconstruction Measurements of inclusive  0 production Reconstruction algorithm - clustering.
The Time-of-Flight system of the PAMELA experiment: in-flight performances. Rita Carbone INFN and University of Napoli RICAP ’07, Rome,
STAR Collaboration Meeting, Nantes, July2002 SVT Analysis/Status Update Jun Takahashi – University of Sao Paulo.
28 February, 2003 STAR Collaboration meeting Status of the dE/dx calibration Yuri Fisyak.
Tests with JT0623 & JT0947 at Indiana University Nagoya PMT database test results for JT0623 at 3220V: This tube has somewhat higher than usual gain. 5×10.
NSW background studies Max Bellomo, Nektarios Benekos, Niels van Eldik, Andrew Haas, Peter Kluit, Jochen Meyer, Felix Rauscher 1.
Optimizing DHCAL single particle energy resolution Lei Xia 1 CALICE Meeting LAPP, Annecy, France September 9 – 11, 2013.
DHCAL - Resolution (S)DHCAL Meeting January 15, 2014 Lyon, France Burak Bilki, José Repond and Lei Xia Argonne National Laboratory.
D 0 Measurement in Cu+Cu Collisions at √s=200GeV at STAR using the Silicon Inner Tracker (SVT+SSD) Sarah LaPointe Wayne State University For the STAR Collaboration.
Real data reconstruction A. De Caro (University and INFN of Salerno) CERN Building 29, December 9th, 2009ALICE TOF General meeting.
Thomas Jefferson National Accelerator Facility Page 1 EC / PCAL ENERGY CALIBRATION Cole Smith UVA PCAL EC Outline Why 2 calorimeters? Requirements Using.
Material budget, energy losses and multiple scattering.
E. De LuciaNeutral and Charged Kaon Meeting – 7 May 2007 Updates on BR(K +  π + π 0 ) E. De Lucia.
Y.Fisyak, BNL - STAR Upgrade workshop, 12/2/ Integrated Tracker – STAR tracking framework of the future update on  status and  perspective IT(TF)
Track extrapolation to TOF with Kalman filter F. Pierella for the TOF-Offline Group INFN & Bologna University PPR Meeting, January 2003.
1 TTU report “Dijet Resonances” Kazim Gumus and Nural Akchurin Texas Tech University Selda Esen and Robert M. Harris Fermilab Jan. 26, 2006.
Recent Charm Measurements through Hadronic Decay Channels with STAR at RHIC in 200 GeV Cu+Cu Collisions Stephen Baumgart for the STAR Collaboration, Yale.
Tracking, PID and primary vertex reconstruction in the ITS Elisabetta Crescio-INFN Torino.
Status of New TPC( Ⅱ ) Performance Study Yohei Nakatsugawa LEPS Meeting in Taiwan.
1 A first look at the KEK tracker data with G4MICE Malcolm Ellis 2 nd December 2005.
FTPC status and results Summary of last data taken AuAu and dAu calibration : Data Quality Physic results with AuAu data –Spectra –Flow Physic results.
1ECFA/Vienna 16/11/05D.R. Ward David Ward Compare these test beam data with Geant4 and Geant3 Monte Carlos. CALICE has tested an (incomplete) prototype.
3D Event reconstruction in ArgoNeuT Maddalena Antonello and Ornella Palamara 11 gennaio 20161M.Antonello - INFN, LNGS.
I.BelikovCHEP 2004, Interlaken, 30 Sep Bayesian Approach for Combined Particle Identification in ALICE Experiment at LHC. I.Belikov, P.Hristov, M.Ivanov,
STAR Analysis Meeting, BNL – oct 2002 Alexandre A. P. Suaide Wayne State University Slide 1 EMC update Status of EMC analysis –Calibration –Transverse.
KalFitAlg: recent developments and tests WANG Dayong Jan.18,2006.
1 Oct 2009Paul Dauncey1 Status of 2D efficiency study Paul Dauncey.
Search for High-Mass Resonances in e + e - Jia Liu Madelyne Greene, Lana Muniz, Jane Nachtman Goal for the summer Searching for new particle Z’ --- a massive.
Charged and Neutral Kaon correlations in Au-Au Collisions at sqrt(s_NN) = 200 GeV using the solenoidal tracker at RHIC (STAR) Selemon Bekele The Ohio State.
Heavy stable-particle production in NC DIS with the ZEUS detector Takahiro Matsumoto, KEK For the ZEUS collaboration.
Kalanand Mishra February 23, Branching Ratio Measurements of Decays D 0  π - π + π 0, D 0  K - K + π 0 Relative to D 0  K - π + π 0 decay Giampiero.
Régis Lefèvre (LPC Clermont-Ferrand - France)ATLAS Physics Workshop - Lund - September 2001 In situ jet energy calibration General considerations The different.
Comparison of MC and data Abelardo Moralejo Padova.
Feb. 3, 2007IFC meeting1 Beam test report Ph. Bruel on behalf of the beam test working group Gamma-ray Large Area Space Telescope.
Particle identification by energy loss measurement in the NA61 (SHINE) experiment Magdalena Posiadala University of Warsaw.
Fast offline dE/dx calibrations Y. Fisyak 11/07/02.
PHENIX J/  Measurements at  s = 200A GeV Wei Xie UC. RiverSide For PHENIX Collaboration.
Particle Identification of the ALICE TPC via dE/dx
INFN - PadovaBeauty Measurements in pp with the Central Detector 1 Beauty Measurements in p-p with the Central Detector F. Antinori, C. Bombonati, A. Dainese,
Non-Prompt J/ψ Measurements at STAR Zaochen Ye for the STAR Collaboration University of Illinois at Chicago The STAR Collaboration:
Feb C.Smith UVA EC energy calibration – g13 pass0 For pass0 data were cooked with CALDB calibration constants reset to nominal 10 channels / MeV.
Time-zero evaluation using TOF, T0 and vertex detectors
TPC status report Marian Ivanov.
Activities on straw tube simulation
Electromagnetic Physics Working Group discussion
Status Report Fenfen An
Observation of a “cusp” in the decay K±  p±pp
Tracking results from Au+Au test Beam
Analysis Test Beam Pixel TPC
HARPO Analysis.
TPC status - Offline Q&A
Status of the TOF Detector
STAR Geometry and Detectors
p0 life time analysis: general method, updates and preliminary result
Larisa Nogach Institute of High Energy Physics, Protvino
Reddy Pratap Gandrajula (University of Iowa) on behalf of CMS
EMCal Recalibration Check
Study of dE/dx Performance in TPC at CEPC
Problems with the Run4 Preliminary Phi->KK Analysis
Study of e+e collisions with a hard initial state photon at BaBar
Contents First section: pion and proton misidentification probabilities as Loose or Tight Muons. Measurements using Jet-triggered data (from run).
Presentation transcript:

June 4, 2009 STAR TPC review Estimation of TPC Aging Based on dE/dx Measurements Yuri Fisyak

June 4, 2009 STAR TPC review Outline Some details of STAR dE/dx calibration (procedure, corrections,…) Previous attempts to observe TPC aging. Run IX: –pp500 versus pp200, –Observed TPC aging, –Extrapolations. Conclusions

June 4, 2009 STAR TPC review STAR dE/dx Calibration The dE/dx calibration is based on a sample of global tracks reconstructed in TPC with momenta in range 0.4 GeV/c < p < 0.5 GeV/c (MIP for pion). For runs with high luminosity (and high rate of pile-up events) these global track sample is restricted to tracks associated with triggered primary vertex in order to avoid problems with wrong distortion corrections due to poorly defined Z coordinate for pile-up hits. dE/dx corrections include: –Relative pad gain calibration based on pulser runs (done online and use for online clustering) –Restriction cluster sample : to non overlapped clusters, and removing clusters near sectors edges where cluster charge (gas gain) significantly drops (5 pads). –“ADC Correction” => ADC nonlinearity corrections, accounting for loss of signal due to: to digitization and thresholds, ADC saturation, and rounding during cluster charge calculation. This correction has been obtained from TPC response simulation. For new TPC electronics this correction has not been obtained yet. –Essential part of the calibration is the TPC distortion corrections which effect the precision of dx measurement. –Set of multiplicative factors: SecRow => “Gas gain” correction for sector/row, Oxygen => Correction for Electron Attachment due to O2, Pressure => Dependence of the Gain on Gas Density due to Pressure, … Length Correction => Correction for track (30% truncated mean) variation versus track length used for the track calculation due to cluster dE/dx dependence on dx.

June 4, 2009 STAR TPC review STAR dE/dx Calibration (cont.) The main tool to obtain “multiplicative factors” is fit of Z-distributions for cluster binned for variable such as sector, row, pressure, … Z = log((dE/dx) measured /(dE/dx) π ), where (dE/dx) π = B(p/m,dx) is prediction of Photo Absorption model (know in STAR as the “Bichsel model”) for π-mass hypothesis. This is an example of such fit of z distribution for clusters in sector 1 and pad row 13. The fit is done with 5 mass hypotheses (represented by Gaussian with the same width) with fixed distance proton, kaon, electron and deuteron hypotheses from π. The fit parameters are: Shift π peak from predicted position (“mu”), A sigma of all Gaussians, and Fraction of all mass hypotheses. This procedure provides precision better than 1%.

June 4, 2009 STAR TPC review STAR dE/dx Calibration (cont.) On this plot relative dE/dx track resolutions versus the track length used for the dE/dx calculation for different RHIC run are presented. The conclusions from this plot are: –The resolutions are about “achievable” value 76 cm track length (Model estimation gives 7.3%). –There is no (at least obvious) time dependence. –There is a dependence on run conditions (mainly hit occupancies and distortion correction precision).

June 4, 2009 STAR TPC review Sigma versus row for different gains In Run IX we have a few runs with reduced anode Voltage. Rough dE/dx resolution estimation: –Nominal Voltage:  I = 0.435/√(0.7  13) = 14.4%  O = 0.41/√(0.7  32) = 8.7%  = 7.45% –Reduced Voltage Inner (relative gain 0.63 with respect to nominal)  I = 0.45/ √(0.7  13) = 14.9 %  = 7.51% –Reduced Voltage Inner and Outer (relative gain 0.63 with respect to nominal)  O = 0.425/ √(0.7  32) = 9.0%  = 7.7% Reduction of gain for Inner sector practically (~0.06%) has no effect on dE/dx resolution but Outer sector gain reduction produces sizeable effect (~0.25%).

June 4, 2009 STAR TPC review Aging measurement based on dE/dx In the past we have tried to estimate TPC aging by comparison “gas gain” correction obtained during dE/dx calibration. This plot (left one, which shows that “gas gain” increase in inner sector with time) has demonstrated that in 2006 we did not control all parameters which influence our gas gain estimation. We could not state anything about TPC aging. A reason could be large variation of pad gains over long time interval (~ year) which can wash out any conclusion about “gas gain” time dependence. For the last run (IX) we have requested special data sample to try to evaluate aging (with new electronics) with hope that new electronics has much lower (<0.2%) pad variation (at least in a month time scale) which will allow to see aging effect on the level of ~1%. Attempt to estimated TPC aging, presented to 2006 TPC review. Gas Gain versus date.

June 4, 2009 STAR TPC review Comparison low luminosity runs pp500 and pp200 (Run IX data) Here we compare data obtained at “low luminosity” at the beginning of pp500 (03/24/09) and the beginning of pp200 just after finishing pp500 (04/28/09). For this period it was collected 10 C for all Inner sectors and 10/3.18 = 3.15 C for Outer sectors (A.Lebedev’s estimation from slow control). Thus accumulated charge per unit length of wire (assuming its 1/r 2 charge dependence): Inner:  Q( ) = 10C /1.6 km = 62.5  C/cm at = 81.4cm (row 5) Outer:  Q( ) = 2.63C/3.6km = 7.3  C/cm at = cm (row 28) If we assume R -1 = -  Q/(  G/G), G ~ exp(-  Q/R -1 ), and  Q =  Q( )( /r) 2 then fit gives R -1 =2.8  0.3[mC/cm]. This value is a factor of 35 less usually claimed ~100[mC/cm].

June 4, 2009 STAR TPC review Tripped anode channel During Run IX pp500 data taking we were suffered from multiple trips in TPC. This plot shows Gas gain ratios for : All pad rows, Pad rows which had multiple trips (>5), and Pad row which did not have multiple trips. The conclusion is that trips have negative effect on gas gain.

June 4, 2009 STAR TPC review Extrapolation to 10 years of RHIC I and RHIC II luminosities On this plot extrapolations to x10 and x40 accumulated charge are shown. The major problems have started with x40 integrated luminosity for Inner Sector.

June 4, 2009 STAR TPC review R’ model R’ aging model: G ~ exp(-R’ √  Q) and  Q =  Q( )( /r) 2 gives R ’ =3.0  0.3[C/cm] -1/2. This value is pretty well matched with data for P10 aging (more in R.Witt talk).

June 4, 2009 STAR TPC review Extrapolation of R’ model to 10 years of RHIC I and RHIC II luminosities R’ model gives much more fair future for STAR TPC aging.

June 4, 2009 STAR TPC review Conclusions: In run IX we have observed (the first time) degradation of Inner Sector gain which is consistent with TPC aging hypothesis. This result should be considered only as preliminary. We have to reevaluate this result using whole run IX data sample and watch the situation during the coming runs. aging constant obtained with the present sample strongly depends on model –For G ~ exp(-  Q/R -1 ) model fit gives R -1 =2.8  0.3[mC/cm], which is a factor ~30 less than expected, –For G ~ exp(-R’ √  Q) model fit gives R ’ =3.0  0.3[C/cm] -1/2, which is consistent with our expectations. Accumulated charge per unit wire length in STAR TPC so far it is still too small in order to give definite predictions for one or two order of magnitude higher integrated luminosity.

June 4, 2009 STAR TPC review 1/R dependence