Scintillator HCAL prototype commissioning and calibration J.Cvach Institute of Physics AS CR, Prague Calibration basics Test results Outlook LCWS 06.

Slides:



Advertisements
Similar presentations
Electromagnetic shower in the AHCAL selection criteria data / MonteCarlo comparison of: handling linearity shower shapes CALICE collaboration meeting may.
Advertisements

2 Introduction   MiniCal test-beam studies started at the beginning of March (till March 6 we only had 17 APD’s, then 33 APD’s)   A few days were.
AHCAL Saturation Study CALICE week – Casablanca, Morocco 2010/09/22 Jaroslav Zalesak Institute of Physics, Prague / DESY Study of single SiPM response.
J-C. BRIENT (LLR) 1  Introduction with pictures  Prototype design and construction  R&D on the design of the full scale calorimeter CALICE - ECAL silicon-tungsten.
27 th May 2004Daniel Bowerman1 Dan Bowerman Imperial College 27 th May 2004 Status of the Calice Electromagnetic Calorimeter.
Calice, UT ArlingtonJiri Kvasnicka, FZU, Prague1 LED notched fiber system Jiri Kvasnicka 1.Introduction 2.Test setup and fiber layout on HBU0.
Calibration issues for the CALICE 1m 3 AHCAL LCWS11 - International Workshop on Future Linear Colliders Granada, Spain 2011/9/28 Jaroslav Zalesak Institute.
External calibration system - QMB6 Distribution of light: Notched Fiber Calibration and Monitoring Board (CMB) 1-ch LED driver (QMB1) Calibration System.
N. Anfimov (JINR) on behalf of the ECAL0 team.  Introduction  Installation and commissioning  Calibration  Data taking  Preliminary result  Plans.
Feb 20, 2009 CALICE meeting, Daegu, Korea QRL in Magnetic Field 1 QRLed Driver in Magnetic Field Jaroslav Zalesak Institute of Physics of the ASCR, Prague.
Optical calibration system for EUDET AHCAL module Jaroslav Cvach IPASCR 1.Calibration system for SiPM photodetectors 2.QRLED driver photoelectron spectra.
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka Institute of Physics, Prague June 11, 2011TIPP 2011, Chicago1 Under.
06/03/06Calice TB preparation1 HCAL test beam monitoring - online plots & fast analysis - - what do we want to monitor - how do we want to store & communicate.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
Uni Bergen:G. Eigen, J. Zalieckas, E. van der Kraaij FZU Prague: J. Cvach, J. Kvasnicka, I. Polák CALICE meeting, Argonne, 19/03/2014.
SPiDeR  SPIDER DECAL SPIDER Digital calorimetry TPAC –Deep Pwell DECAL Future beam tests Wishlist J.J. Velthuis for the.
AHCAL Electronics. Status Commissioning and Integration Peter Göttlicher for the AHCAL developers CALICE meeting UT Arlington, March 12th, 2010.
Calibration UV LED system for CALICE scintillator based Tile Hadron Calorimeter Ivo Polák on behalf of the CALICE Collaboration Institute of Physics of.
The Scintillator ECAL Beam Test at FNAL Adil Khan International Linear Collider Workshop 2010 LCWS10 & ILC10, Beijing, China CALICE Scintillator ECAL group.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
Hadron Calorimeter Felix Sefkow EUDET Annual Meeting October 20, 2006.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Munich, 18 Oct 2006J. Cvach, annual JRA31 JRA3 Institute of Physics ASCR Prague 1.ECAL, VFCAL (V. Vrba) 2.HCAL (J. Cvach) 3.Exchange in NA2 (travels 8.5.
1. DESY tests 2. Electronics developments 3. Optical developments 4. Outlook Casablanca J. Cvach, CALICE Coll. meeting.
Montpellier, November 15, 2003 J. Cvach, TileHCAL and APD readout1 TileHCAL- fibre readout by APD APDs and preamplifiers Energy scan with DESY beam –Energy.
Toward the FNAL Beam Test S. Uozumi (Kobe) May Japan-Korea meeting.
Uni Bergen:G. Eigen, E. van der Kraaij, J. Zalieckas FZU Prague: J. Cvach, J. Kvasnička, I. Polák Linear Collider Workshop, Tokyo 13/11/2013.
Pion Showers in Highly Granular Calorimeters Jaroslav Cvach on behalf of the CALICE Collaboration Institute of Physics of the ASCR, Na Slovance 2, CZ -
Optical Part of the CMB for AHCAL-CALICE Jaroslav Zalesak Institute of Physics, Prague.
E. GaruttiCALICE collaboration meeting, Prague CERN Test beam (part II) Erika Garutti, Fabrizio Salvatore.
R&D status of the Scintillator- strip based ECAL for the ILD Oct LCWS14 Belgrade Satoru Uozumi (KNU) For the CALICE collaboration Scintillator strips.
AHCAL Electronics. Status Commissioning Mathias Reinecke for the AHCAL developers HCAL main meeting Hamburg, Dec. 10th, 2009.
SCECAL progress report Tohru Takeshita (Shinshu) _DESY Beam Test summary _improvements for FNAL BT _FNAL module _current status at Fermilab.
ILC Calorimetry Test Beam Status Lei Xia ANL HEP.
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
Main HCAL, JUL1,2008Ivo Polak, IP_ASCR, Prague1 Calibration system with optical fibers HCAL main meeting, DESY.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
Systematics on ScECAL 1 st prototype DESY Apr , CALICE Satoru Uozumi for the CALICE collaboration NIM A, 763 (2014) 278.
Scintillator HCAL read-out and calibration Felix Sefkow TILC08 at Sendai, Japan March 4, 2008.
11 October 2002Paul Dauncey - CDR Introduction1 CDR Introduction and Overview Paul Dauncey Imperial College London.
The CALICE scintillator tile HCAL project Felix Sefkow LCWS’06, Bangalore March 9-13, 2006.
Calibration issues for the CALICE 1m3 AHCAL ALCPG11 - Linear Collider Workshop of the Americas Eugene, Oregon, USA 2011/3/22 Jaroslav Zalesak Institute.
LHCf Detectors Sampling Calorimeter W 44 r.l, 1.6λ I Scintilator x 16 Layers Position Detector Scifi x 4 (Arm#1) Scilicon Tracker x 4(Arm#2) Detector size.
Tile HCAL status Felix Sefkow CALICE Technical Board Review April 19, 2007.
G. Eigen, Paris, Introduction The SiPM response is non-linear and depends on operating voltage (V-V bd ) and temperature  SiPMs need monitoring.
Annual EUDET, OCT6,2008 Ivo Polak, IP_ASCR, Prague1 Calibration system with optical fibers for AHCAL EUDET annual meeting, NIKHEF 1.Introduction 2.QRLed.
Hadron Calorimeter Felix Sefkow EUDET Extended Steering Meeting September 11, 2006.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
DHCAL Jan Blaha R&D is in framework of the CALICE collaboration CLIC08 Workshop CERN, 14 – 17 October 2008.
Energy Reconstruction in the CALICE Fe-AHCal in Analog and Digital Mode Fe-AHCal testbeam CERN 2007 Coralie Neubüser CALICE Collaboration meeting Argonne,
DESY, 8 Dec 2005J. Cvach, prekick-off JRA3 JRA3 Institute of Physics ASCR Prague 1.ECAL, VFCAL (V. Vrba) 2.HCAL (J. Cvach) 3.Exchange in NA2 (travels 8.5.
Front-end Electronic for the CALICE ECAL Physic Prototype Christophe de La Taille Julien Fleury Gisèle Martin-Chassard Front-end Electronic for the CALICE.
Next generation HCAL prototype Felix Sefkow EUDET electronics meeting UCL, December 5, 2006.
SiW ECAL Marcel Reinhard LLR – École polytechnique LCWS ‘08, Chicago.
JRA3 Institute of Physics ASCR Prague
PreShower Characterisations
LED notched fibre system short HBU0 party with QMB6
the CALICE test beam set-up and running experience
CALICE scintillator HCAL
CMS ECAL Calibration and Test Beam Results
ScECAL+AHCAL+TCMT Combined Beam FNAL
Felix Sefkow CALICE/EUDET electronics meeting CERN, July 12, 2007
Scintillator HCAL: LOI issues
E. Garutti - Main Meeting
Testbeam analysis on module #1
Scintillator HCal Prototype
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

Scintillator HCAL prototype commissioning and calibration J.Cvach Institute of Physics AS CR, Prague Calibration basics Test results Outlook LCWS 06

J. Cvach, AHCAL prototype2 LCWS06, March 10, 2006 HCAL test beam prototype 1 m 3 tile HCAL prototype: 38 modules ~ 8000 scintillator tiles equipped with SiPM module has a sandwich structure: scintillator plane + 2cm steel absorber plate at present 6 planes in tests, 4 planes under construction HCAL: High granularity scintillator tiles 3x3cm 2 in the core with individual readout ECAL: Silicon-tungsten 40 layers, 1x1cm 2 K. Gadow

J. Cvach, AHCAL prototype3 LCWS06, March 10, 2006 The calibration concept (each channel) Single pixel MIP calibration Gain calibration: scintillator, pixel SiPM response function MIP E (GeV) = A(ADC) * px/ADC * pe/px * MIP/pe * GeV/MIP Energy = ADC-count * electronics * SiPM response * Light yield * sampling

J. Cvach, AHCAL prototype4 LCWS06, March 10, 2006 Calibration procedure SiPM gain calibration with low intensity LED light 0 pixel 1 pixel 2 pixels MIP calibration of each tile with 3 GeV e + beam using ASIC chip in 2 modes: “calibration mode”“physics mode” shaping time 40ns shaping time 180 ns highest gain medium gain Minimum ionizing energy Noise spectrum intercalibration term

J. Cvach, AHCAL prototype5 LCWS06, March 10, 2006 Very Front-End Electronics ILC-SiPM chip: 18channel - based on CALICE SiW ECAL chip SiPM bias voltage adjustment (0-5 V) Global gain settings and shaping Track & hold, multiplexing Trigger latency Single p.e. resolution

J. Cvach, AHCAL prototype6 LCWS06, March 10, 2006 A redundant monitoring system The stability of the system in between MIP calibrations is checked by monitoring: 1.SiPM response for fix intensity LED light dG/dT ~ -4.5% / K dG/dV ~ 7% / 0.1V  stability of LED system after PIN diode correction <1% 2. Gain of SiPM dG/dT ~ -1.7% / K dG/dV ~ 2.5% / 0.1V 3. Temperature and voltage monitoring from slow control  in addition the LED system is used for: monitoring SiPM response function / gain calibration / electronics inter-calibration CMB T HBAB_TOP HBAB_BOT HCAL module SiPM r/o board 12 LED 12 PIN d. T T T T T T T T T T 18 clear fibres to tiles 1 fibre to PIN diode

J. Cvach, AHCAL prototype7 LCWS06, March 10, 2006 Calibration and monitoring system I LED fibres to all tiles Good uniformity of light LED to fibre coupling Coupling of fibre light into tiles LED light emission unisotropy  angular < 15%  Intensity (?) - measured now metal sleeve K. Gadow DESY J. Zálešák Prague

J. Cvach, AHCAL prototype8 LCWS06, March 10, 2006 Calibration and monitoring system II Calibration & monitoring board – to deliver LED light  dynamic range 0.5 – 100 MIP Functions  LED control Amplitude (via DAQ, CANbus, standalone) Pulse width: 5 ns  Enable  PIN diode readout  Temp monitoring Measurement of nonlinearity  LED intensity varied by DAQ  Intensity measured by PIN  Absolute calib from linear part 3 pulse generators 12 PIN ampli control 1V 10 ns

J. Cvach, AHCAL prototype9 LCWS06, March 10, 2006 Calibrating 18 SiPM with one LED Gain calibration for a matrix of 18 SiPM connected to the same LED

J. Cvach, AHCAL prototype10 LCWS06, March 10, 2006 HCAL tests: Sept 2005 – Feb st beam test successful DESY test beam area September  1 plane, FE electronics & DAQ (CRCs VME)  Confirmation of the calibration with LED light & MIP on large scale & homogenity over plane Continued through the Christmas with cosmics  3 complete modules  Test of sensitivity to temperature variations & correction 2 nd beam run period April 2006  3 planes with CMBs  Training of shift crews for summer beam tests In between cosmic run with ECAL DESY testbeam

J. Cvach, AHCAL prototype11 LCWS06, March 10, ch. MIP average: 410 ADC ch +/- 18% MIP and LY calibration – comparison Gain calibration MIP calibration Inter calibration DESY beam (Sept. 05) LY: 13 pix/MIP, RMS 2 pix/MIP DESY Lab (Dec. 04) LY: 15 pix/MIP, RMS 2 pix/MIP Error on LY: 13.0 ± 0.3 ± 0.7 pix/MIP stat. sys.   ~1 pix/MIP due to temp diff during the two measurements M. Groll sys. err.: pedestal fluctuation ~2%, T fluctuation ~2.5%

J. Cvach, AHCAL prototype12 LCWS06, March 10, 2006 Calib. procedure & beam shower - HCAL plane scanned with e GeV and monitored by LED  MIP calibration, LY calibration - Beam scan on plane surface (with 1 X 0 lead) ~ at PMT2  check uniformity of module response - Beam scan on plane surface (with 5 X 0 lead) ~ at PMT2  check SiPM saturation correction - Comparison of PMT, SiPM with MC  check the corrections PMT1 PMT2PMT3 1, 5 X 0 Pb HCAL plane Lead: R M = 0.9 cm X 0 = 0.56 cm e GeV 5x5x0.5 cm 3 scintillator 3x3x1 cm 3 scintillator with Hamamatsu R5505

J. Cvach, AHCAL prototype13 LCWS06, March 10, 2006 Uniformity studies 25 matrices of 3x3 cm 2 tiles scanned: - SiPM/PMT3 – to eliminate beam spread - average in agreement with MC - 5% spread over the HCAL core w/o temperature & pedestals corrections  Good uniformity within the meas. accuracy Scan of HCAL plane with 3 GeV beam and 1X 0 in front  Energy = Σ shower energy on a 3x3 matrix of tiles (~99%) 1.25± ±0.05 MC

Shower analysis Shower produced by 1X 0 Shower produced by 5X 0 SiPM saturation visible After saturation correction neighbours w/o optical Xtalk correction Shower produced by 1X 0 ~2% optical Xtalk central tiles w/o saturation correction Shower produced by 5X 0 O GEANT3 ~10% 60 MIP

J. Cvach, AHCAL prototype15 LCWS06, March 10, 2006 Saturation correction Shower produced by 5X 0 O GEANT3 non-linearity corrected after before Good agreement between data/MC after SiPM saturation 5-6 GeV lateral leakage in ref. scintill. M. Groll, Y. Soloviev

J. Cvach, AHCAL prototype16 LCWS06, March 10, 2006 Xmas cosmic run Xmas run lasted from December 23 rd till January 9 th Modules connected: #4, #5, #6 Monitoring done only for module #5:  3 LED driven with prototype LED driver, steered by DAQ  + 3 PIN diodes r/o on prototype preamp. boards  all components from standard CMB board In addition 16 ECAL slabs were connected and “partially” in operation  trigger distribution problems + high leakage current Cosmic trigger: coincidence of two 30x40 cm 2 scintillator plates ~1m apart

J. Cvach, AHCAL prototype17 LCWS06, March 10, 2006 Cosmics data taking with 3 modules  Cosmic muon passing three modules Many data on tape Gain analysis at low LED light done – sensitivity to temperature demonstrated Analysis of corrections from LED monitoring system, PIN diodes and slow control … and other analyses in progress

J. Cvach, AHCAL prototype18 LCWS06, March 10, 2006 Gain variation over two weeks time ~ 2 weeks Temp. [ C ] Average of 18 SiPM connected to one LED Temperature measurement from 5 sensors inside one module MEPHI measurement: dG/dT ~ -1.7% / K From average of 18 x 3 SiPM in HCAL: dG/dT ~ -(1.6 +/- 0.5)% / K

J. Cvach, AHCAL prototype19 LCWS06, March 10, 2006 Conclusions Time schedule tough – group looks forward to the comming tests Proof of principles Answers to many open questions:  Is the level of calibration accuracy sufficient ?  How to get MIP calibration in the ILC calorimeter ?  Is the LED light needed for gain measurement ? alternatives:  gain from high stat. pedestal (optical crosstalk)  better pixel higher amplitude (low noise)  Can the gain be used to measure amplitude changes ? implication:  maybe no need of LED system ?  Is the temperature measurement needed ? Can it replace the monitoring system ?  Is the SiPM response function stable enough ?  Experience with the HCAL prototype + future R&D will give the answer

Back-up slides

J. Cvach, AHCAL prototype21 LCWS06, March 10, 2006 SiPM response function Ideally: Correct “all” SiPM with one unique response function which describes: Geiger discharge efficiency effective number of pixels inter-pixels crosstalk  It worked for 100 channels in the technical prototype (Minical) Reproducibility of 6 measurements in controlled environment LED pulse width: 6ns, 8ns, 12ns, 20ns To apply a unique correction function for all SiPMs: Light Yield  calibrate curve for each SiPM using Light Yield  correct T & V dependence of response function measured in lab with 10% accuracy H. Meyer SiPM with >2M  R quench ~50 MIP

J. Cvach, AHCAL prototype22 LCWS06, March 10, 2006 HCAL readout architecture Base boards with 2 *6 piggy backs / layer 18 analog channels VME DAQ

J. Cvach, AHCAL prototype23 LCWS06, March 10, 2006 Ordered 7 CRC boards for AHCAL Identical design to ECAL CRCs Produced through Rutherford JTAG tests at Rutherford Tests in DAQ system at Imperial With no VFE input, good CRC has: Pedestals within 100 ADC counts of zero (within ±32k range) Noise around 1.4 counts but can vary down to 0.8, up to 2.0 Measure of crosstalk; good channel sees almost nothing until near saturation Present status Four CRCs are running at DESY tent in ECAL + AHCAL cosmic tests Three CRCs expected in March CALICE Readout Card Pedestal Noise

J. Cvach, AHCAL prototype24 LCWS06, March 10, 2006 Beam scan on tile surface in 1mm steps  MIP amplitude meas. at each step max variation ~10%, RMS = 4.7% (remember 2% reproducibility !!)  Integrated energy deposited above ½ MIP at each step gives an idea of the beam profile Problems:  The beam is too broad for a precise measurement of edge eff. Tile Uniformity Check with Beam tile 1 tile 2

J. Cvach, AHCAL prototype25 LCWS06, March 10, 2006 For 25 3x3 cm tiles: General agreement to MC only 5% spread between channels w/o any temperature & pedestals corrections Some physics: determination of lead moliere radius data: R M = 0.76 ± 0.07 cm MC: R M = 0.92 cm Summary: 1X0 analysis MC prediction

J. Cvach, AHCAL prototype26 LCWS06, March 10, 2006 Toward the beam test HCAL beam tests – 8 weeks at H6b CERN beam area in August – October The goal – to start with 18 HCAL modules in August Commissioning of the monitoring system – now Production of 12 modules started in February Movable table construction: February - April Commissioning of the assembled stacks with cosmics – June Transport to CERN – beginning of July, tests with DAQ H6 beam  5 – 205 GeV/c, up to 10 8 π + /spill (5 GeV/c ~ 1000 particles/spill)  5 – 100 GeV/c electrons  Parasitic μ runs possible