Tympanometry and Reflectance in the Hearing Clinic Presenters: Dr. Robert Withnell Dr. Sheena Tatem.

Slides:



Advertisements
Similar presentations
1 Non-Linearities Linear systems (e.g., filters) can change the intensity and phase of a signal input. Non-linear systems (e.g., amplfiers) not only can.
Advertisements

Alternative Assessments for Musicians Marshall Chasin, AuD., M.Sc., Reg. CASLPO, Aud(C) Musicians’ Clinics of Canada.
ACAud Roadshow Acoustics for Professionals Dominic Power Connect Hearing University of Melbourne.
Probe Tube Microphone Measurements (Basics and Definitions) Greg Nassar MCHAS Team University of Manchester.
The peripheral auditory system David Meredith Aalborg University.
Program.
TOPIC 5 NONBEHAVIORAL ASSESSMENT MEASURES IMMITANCE AUDIOMETRY.
HEARING MUSICAL ACOUSTICS Science of Sound Chapter 5.
PH 105 Dr. Cecilia Vogel Lecture 8. OUTLINE  Exam #1  Hearing  subjective qualities of sound  the ear  intensity vs pressure  pressure and frequency.
Resonance, Sound Waves and The Ear
ASHA 1997 HEARING SCREENING GUIDELINES ASHA Guidelines for Hearing Screening - Children 1997.
Continuity Clinic Tympanometry. Continuity Clinic Objectives Identify the uses and limitations of tympanometry and SGAR in the diagnosis of otitis media.
EE Audio Signals and Systems Kevin D. Donohue Electrical and Computer Engineering University of Kentucky.
Medical Physics Brain.
Resonance, Sound Waves and The Ear. What does the natural frequency depend upon?  The natural frequency depends on many factors, such as the tightness,
Resonance, Sound Waves and The Ear
Hearing Chapter 5. Range of Hearing Sound intensity (pressure) range runs from watts to 50 watts. Frequency range is 20 Hz to 20,000 Hz, or a ratio.
The Ear.
CHAPTER 6 Outer and Middle Ears.
IB Assessment Statements Option I-1, The Ear and Hearing: I.1.1.Describe the basic structure of the human ear. I.1.2.State and explain how sound pressure.
Anatomy and Physiology of the Ear
© Houghton Mifflin Harcourt Publishing Company Preview Objectives The Production of Sound Waves Frequency of Sound Waves The Doppler Effect Chapter 12.
PHY238Y Lecture 11 The human ear: amplification of the outer/inner ear Acoustic impedance. Physics of hearing (III) Protection mechanisms of the human.
Acoustic Immittance Otoacoustic Emissions Auditory Evoked Potentials Objective Tests.
EAR AND HEARING Resonant Frequencies of pinna and EAM are Hz.
Otoacoustic Emission Test. What are otoacoustic emissions? These are low intensity sounds produced by the cochlea as the outer hair cells expand and contract.
Objective Tests of the Auditory System SPA 4302 Summer 2007.
AUDIOLOGY IN ORL DR. BANDAR MOHAMMED AL- QAHTANI, M.D KSMC.
The Lever Ratio. Purpose of ME To transmit sound energy from the air space in the EAC to the fluid in the cochlea This is accomplished by vibration of.
Objective tests of the auditory system 1. Acoustic immittance measures Static acoustic compliance Static acoustic compliance Tympanometry Tympanometry.
INTRODUCTION TO TYMPANOMETRY
Hearing Loss Basic Audiology Information By El Eshun.
Otoacoustic Emissions
Physiology Middle ear space stiffness dominated: High- frequency emphasis.
Screening Tests for DISORDERS!!! Or Crusading the Clinic.
Objective Tests of the Auditory System SPA 4302 Summer A, 2004.
Impedance (Z) vs. Admittance (Y) Resistance(R) Mass Reactance(Xm) Stiffness Reactance(Xs) Z = (R 2 + X t 2 ) 1/2 Conductance(G) Mass Susceptance(Bm) Stiffness.
Anatomy of the Ear Dr isazadehfar.
PHY238Y Lecture 10 The human ear (outer and middle) Physics of hearing (II) References: Haliday, Resnick, Walker: Fundamentals of Physics, 6 th ed. 2003,
Chapter 12 Preview Objectives The Production of Sound Waves
Introduction to Audiology Ed Brown Consultant Clinical Scientist (Audiology) South of Tyne NHSP Local Director Royal Hospital Sunderland SR4 7TP
HEARING- 3. LEARNING OBJECTIVES LEARNING OBJECTIVES Discuss the principles used in performing tests of hearing Discuss the principles used in performing.
Otology Eleanor Houghton. Objectives 1.Differentiate between: a)sensorineural and conductive deafness b)subjective, objective, physiological and pathological.
Acoustic Immitance (Impedance and Admittance)
MEMRO 2009 What does the Acoustic Reflectance tell us about the middle ear? MEMRO 2009 The equivalent volume (in ccm) of the ear canal is estimated.
Copyright © American Speech-Language-Hearing Association
Loudness level (phon) An equal-loudness contour is a measure of sound pressure (dB SPL), over the frequency spectrum, for which a listener perceives a.
Single-element transducers properties
Loudness level (phon) An equal-loudness contour is a measure of sound pressure (dB SPL), over the frequency spectrum, for which a listener perceives a.
Sarah Robinson, Suzanne Thompson, Jont Allen
The Doppler Effect PHY238Y Lecture 13 References:
Peripheral Auditory System
Loudness level (phon) An equal-loudness contour is a measure of sound pressure (dB SPL), over the frequency spectrum, for which a listener perceives a.
Distributed Sources of Otoacoustic Emissions
Hearing Biomechanics Standing waves.
Resonance, Sound Waves and The Ear
Unit 7: Vibrations, Waves & Sound Chapter 20: Sound
Architectural Acoustics
Click to edit Master text styles
Electrophysiological Measures of the Auditory System
Click to edit Master text styles
Middle Ear.
Chapter 17 Goals: Understand the principle of superposition.
Ishan Bhatt, PhD, CCC-A, FAAA
Click to edit Master text styles
ОПШТЕСТВО ТЕМА: МЕСТОТО ВО КОЕ ЖИВЕАМ Скопје
Click to edit Master text styles
Chapter 12 Sound © 2014 Pearson Education, Inc..
The 4th Family Medicine Review Course
Click to edit Master text styles
Presentation transcript:

Tympanometry and Reflectance in the Hearing Clinic Presenters: Dr. Robert Withnell Dr. Sheena Tatem

Accurate assessment of middle ear function is important for appropriate management of hearing loss. Two tools available for assessing middle ear function are tympanometry and wideband reflectance. Tympanometry and reflectance both assess how the middle ear receives sound. Critical to their interpretation is an understanding of how the resonance(s) of the middle ear change with middle ear pathology or static pressure changes in the ear canal. Seminar attendees will discover how to interpret tympanograms obtained at multiple frequencies and what the different tympanogram shapes mean in terms of middle ear resonance. Participants will be given the tools to make a reflectance measurement and be able to interpret the results, as well as be able to describe what tympanometry and reflectance have in common and how they differ. Abstract

Learning Outcomes Participants will learn: 1. how to interpret tympanograms obtained at multiple frequencies and what the different tympanogram shapes mean in terms of middle ear resonance. 2. how to make a reflectance measurement and how to interpret the results. 3. what tympanometry and reflectance have in common and how they differ.

Finding the Input Impedance of the Ear Outer and middle ear act to impedance match sound in air to sound in fluid If P r = 0 perfect impedance match If P r = P i 100% impedance mismatch Tympanometry: Reflectance: Probe tone frequency Static pressure in ear canal Microphone

Tympanometry

1960s Clinical measurements from 125 to 1500 Hz was recommended (Zwislocki, 1963; Feldman, 1963, 1964) 226 Hz probe tone 1970s Tympanometry at 226 Hz Tympanometry using high frequency probe tones was not diagnostic (Alberti and Jerger, 1974) ??? Middle ear frequency response reactance The most important parameter from a diagnostic standpoint, the first resonant frequency of the middle ear, is ignored. resonances

Tympanometry A Normal Tympanogram: Liden et al. (1970) Probe tone frequency = 800 Hz What probe tone frequency is optimal for measuring a tympanogram?

ECV – = Y -400 daPa – estimated volume of air in front of the probe SC – = Y tm – Maximum compliance of the middle ear system (static compliance) TPP – Pressure at which the middle ear system has the greatest absorption of sound energy (tympanometric peak pressure) TW – Width of the tympanogram curve Data Obtained from a Tympanogram m TPP

–The value of static compliance provides information about the stiffness of the middle ear system –Normal range Adults 0.4 to 1.6 cc –90% range –(Shahnaz & Polka, 1997, E&H 18(4)) Static compliance m

Ear canal volume Tympanometry estimates of ECV over-estimate the actual volume As static pressure increases from daPa to 200 daPa the magnitude of the error increases Ear canal volume measured with a 660 Hz probe tone is more accurate than the standard 220 Hz tone Shanks & Lilly 1981

Normal range –Adults 48 to 134 daPa 90% range (Shahnaz & Polka, 1997, E&H 18(4)) TW is the width of the tympanogram measured in daPa at half of the height from tympanogram peak to tail (Wiley & Stoppenbach, in Katz, 2002, p. 170) TW Tympanometric width

Tympanogram shapes

226, 678, and 1000 Hz

Demonstration 226, 678, and 1000 Hz

What do these results mean?

To understand these different tympanogram shapes, obtained with different probe tone frequencies, we need 1. to understand how changing static pressure influences the middle ear 2. a model of the ear 3. a model for generation of tympanograms

To understand these different tympanogram shapes, obtained with different probe tone frequencies, we need 1. to understand how changing static pressure influences the middle ear 2. a model of the ear 3. a model for generation of tympanograms

Static pressure change in ear canal Static pressure changes in the ear canal increases the stiffness of the middle ear seeRabinowitz (1981) Huang et al (2000) Increase stiffness increase resonance static pressure = middle ear resonance Middle ear resonance increasing Increasing (+/-) static pressure Middle ear frequency response

Tympanogram with a different x- axis Increasing (+/-) static pressure Middle ear frequency response Frequency (Hz) Tympanogram Can think of static pressure axis on tympanograms as middle ear resonance rather than pressure

To understand these different tympanogram shapes, obtained with different probe tone frequencies, we need 1. to understand how changing static pressure influences the middle ear 2. a model of the ear 3. a model for generation of tympanograms

Modeling input impedance of ear Ear canal Lossy transmission line Middle ear and cochlea Three stiffness terms  Middle ear cavity  Eardrum, ossicles, annular ligament?  Cochlea Six tuned oscillators... six resistance terms RC term for cochlea

To understand these different tympanogram shapes, obtained with different probe tone frequencies, we need 1. to understand how changing static pressure influences the middle ear 2. a model of the ear 3. a model for generation of tympanograms

Modeling Tympanometry Static pressure change (+ or − )in the ear canal increases the stiffness of middle ear Stiffness change probably not symmetrical... treated as symmetrical for +,− change Static pressure change produces probable change to cavity, middle ear and cochlear stiffness... model change only in middle ear stiffness

Model fit to data for tympanograms Model tympanograms normalized to fit tail at +200 daPa at each frequency To get asymmetry in tympanograms, had to have R vary for negative static pressures (in addition to k) data model

Model-generated family of Tympanograms - relationship to resonance

What is the inverted W? Probe frequency is above the first resonance of the middle ear middle ear resonance Peaks associated with static pressure change shifting first resonance of middle ear to probe frequency

Multiple tympanogram frequencies better describes filtering of ME Shape of tympanogram reflects proximity to ME resonance

Pathologies of the Middle Ear Tympanogram shapes represent a continuum with respect to resonance of the middle ear For a 226 Hz probe tone: A flat, type B tympanogram, is a long way from resonance A shallow type A tympanogram is far from resonance The bigger the peak, the closer the probe tone frequency is to resonance

Reflectance

Tympanometry vs Reflectance ZsZs Z ear Tympanometry  Impedance of sound source (Z s ) is not known  Impedance of ear (Z ear ) is estimated Power Reflectance  Impedance of sound source (Z s ) is known  Derive impedance of ear Z ear Sound pressure – measured by a microphone in both cases (P m )

Z ec Z me  Z ear Tympanometry –Z ear is a relative measure –Z ear expressed as a volume Power Reflectance –Z ear is derived –P s, Z s obtained from calibration Sound pressure at the microphone is inversely proportional to Z ear Z ear = Z S *P m P s -P m Withnell et al. (2009)

Comparing methods Tympanometry Acoustic impedance v. Pressure (Z vs. P) frequency is fixed (e.g., 226 Hz) Power Reflectance Acoustic impedance v. frequency (Z vs. f) static pressure in the ear canal is fixed

Calibration 0.5, 2 and 5 cc cavities calibrates 226 Hz 0.5 and 2 cc cavities calibrates 678 Hz 0.5 cc cavity calibrates 1000 Hz (GS Tympstar) TympanometryReflectance A number of cylinders of constant diameter, with different lengths dB SPL

Volume calibration Limited to low frequencies (up to 1500 Hz) Cylinder calibration, known radius and lengths Upper frequency limit depends on radius Probably at least 10 kHz Standing waves in cylinders complicate calibration Radius of cylinder must be similar to ear canal (bony portion)

Click to edit Master text styles Second level Third level Fourth level Fifth level Reflectance Provides a broad spectrum measure of the impedance mis- match between the ear canal and middle ear Does not require static pressure changes in the ear canal The reflectance transfer function alters predictably with middle ear pathology Withnell et al., 2009

Stiffness dominated region of middle ear POWER REFLECTANCE MIDDLE EAR TRANSFER FUNCTION Withnell et al., 2009

Increase in stiffness of middle ear POWER REFLECTANCE MIDDLE EAR TRANSFER FUNCTION Power reflectance results from a subject with otosclerosis (Allen et al., 2005) Withnell et al., 2009

Decrease in stiffness of middle ear POWER REFLECTANCE MIDDLE EAR TRANSFER FUNCTION Power reflectance results from a subject with middle ear disease as a child (Mimosa data) Withnell et al., 2009

OME MIDDLE EAR TRANSFER FUNCTION POWER REFLECTANCE Power reflectance results from a subjects with otitis media with effusion (Allen et al., 2005) mostly INCREASE in M.E. stiffness middle ear not fluid-filled Withnell et al., 2009

Tympanometry and Reflectance in the Clinic. The how, what and why. how to do it what the results mean why multiple frequencies Questions?....

Dr. Robert Withnell