CIGRE SC-B5 Colloquium 2005 Sept.14-16 Calgary Canada PS3:Protection & Control of Series Compensated networks Q3:Are there any experiences of other unique.

Slides:



Advertisements
Similar presentations
FAULT TYPE SELECTION Jeff Roberts April 6 and 9, 2005.
Advertisements

Transmission Operator Protection System Misoperations 2014 ERCOT Transmission Protections System Misoperations Data – 138kV and 345kV Combined (Not including.
Lecture 1. Balanced Three-phase Systems From Network to Single-phase Equivalent Circuit Power plant TransformerSwitching station LineLoad Three-phase.
Announcements Be reading Chapters 8 and 9
Research & production enterprise «EKRA», Ltd,
CIGRE 7-10 September 2009, Moscow
Name: Osamu TSUBOI Country: Japan Registration No.: Group: B5 Pref. Subject: 1 Question: 7 1 Question 7 Non-harmonic-restraint schemes applied in Japan.
Page1 Deppon Protection System. Page2 Deppon OBJECTIVES To isolate a faulty equipment from other healthy parts of the system To minimise effects of abnormal.
AC circuit breaker with series connected switches George G Karady.
Zoran Gajić ABB AB Vasteras, Sweden
CIGRE Study Committee B5 Colloquium, Calgary September 2005 AREVA T&D Automation Protection & Control of Series Compensated Networks Z Q Bo PART.
Applied Harmonics Control of Harmonics
1 © ABB AB, Application of Unit Protection Schemes for Auto-Transformers Zoran Gajić ABB AB Vasteras, Sweden Authors: Z. Gajić, ABB Sweden.
Preferential Subject #3 Protection and Control of Series Compensated Networks Special Reporter: Graeme Topham South Africa Study Committee B5 Colloquium.
KD Relay Application: Compensator distance relay that provides a single zone of phase protection for all three phases. It provides tripping for phase to.
(C) 2006, SUCCESS by DESIGN Surge Values at Each Test Stator surged to fault Indicates decrease in dielectric strength following each test. Applied Surge.
Preferential Subject #3 Protection and Control of Series Compensated Networks S U M M A R Y Special Reporter: Graeme Topham South Africa Study Committee.
Protection & Switchgear
Introduction To Protective Relays
Announcements Read Chapters 10 and 11
1 Distributed Generation and Power Quality-Continued.
EE1 PEEE Refresher Class Power Part 4 notes by T. Ernst EE1 – Power Part 4 NotesFall 2011, Page 1.
Lecture II Objective: Representation of sequence components
CIGRE 2005 Joint Meeting 1 CH, Gino Bacchini & Walter Baass CIGRE SC B5 Colloquium in Calgary 2005: SR for PS#3 Question 14 Joint Meeting and Colloquium.
Protection of Power Systems
البحث السابع بحث منفرد منشور فى مؤتمر دولى متخصص (منشورة التحكيم علي البحث الكامل) Adel A. Elbaset 13th International Middle East Power System Conference,
Impact of Distributed Generation on Fault Induced Transients: A Case Study Sukumar Brahma Adly Girgis Clemson University Electric Power Research Association.
Protection of Power Systems
Utilize Distributed Power Flow Controller (DPFC) to Compensate Unbalanced 3-phase Currents in Transmissions Systems By UNDER THE GUIDENCE OF.
Power System Protective Relaying-Part One
Design a protection System of 220/33kV Grid Station United Arab Emirates University College of Engineering Saif Mohammed AL Aryani Ahmed Soruor.
 Energised by two quantities(voltage and current)  Φ1 and Φ2 set by voltage and current  Eddy currents induced in the disc due to two fluxes  Interaction.
Lecture 10: Programmable Logic Controllers
Announcements Design Project has firm due date of Dec 4
LINE PROTECTION.
PROBLEM OF SPILL CURRENT WITH RESIDUALLY CONNECTED
PS3: Protection & Control of Series Compensated Networks
Effects of GIC Neutral Blocking Devices (NBDs) on Transmission Lines Protection Performance and Potential for Resonance.
Announcements Please read Chapters 9, 10 and 11 HW 8 quiz today
Protection of Power Systems
Quality and Security Assessment of Protection Systems
2004 Cigre SCB5 Session Preferential Subject 3
Protection Relay Testing
Pulse Processing and Shaping
CIGRE SC B5 COLLOQUIUM CALGARY
Cigre SCB5 Colloquium 2005 September, Calgary Preferential Subject 2
Luka Strezoski Marija Prica
 An R-L-C series circuit is at electrical resonance when  X L =X C, the net reactance X=0  Under resonance conditions I. Circuit impedance, Z=R II.
POWER SYSTEM ANALYSIS INTRODUCTION.
IEEE Guide for Protective Relay Applications to Transmission Lines
Manisha Goel, Lecturer, EE Deptt Govt. Polytechnic Manesar
Protective Relaying Conference
UNIT II APPARATUS PROTECTION.
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
Circuit Breaker Ratings – A Primer for Protection Engineers
Peter van Oirsouw (Phase to Phase)
Specifications Updates and Approval
Considerations and Benefits of Using Five Zones for Distance Protection Ricardo Abboud, Jordan Bell, and Brian Smyth Schweitzer Engineering Laboratories,
Yujie Irene Lu & Song Ji May 2nd, 2018
Distance Protection: Why Have We Started With a Circle, Does It Matter, and What Else Is Out There? Edmund O. Schweitzer, III and Bogdan Kasztenny Schweitzer.
WECC Short Circuit Analysis
Power System Protective Relaying-Part One
EUS 260 Capstone Project.
WECC Short Circuit Analysis
World leader in Power System Protection Testing
Distance Relay Specification
AD5933 報告人:葉榮陞 指導教授:沈毓泰.
ECE 476 POWER SYSTEM ANALYSIS
EUT 1040 Lecture 10: Programmable Logic Controllers Unrestricted.
Exercise Session 11 Power systems.
Presentation transcript:

CIGRE SC-B5 Colloquium 2005 Sept Calgary Canada PS3:Protection & Control of Series Compensated networks Q3:Are there any experiences of other unique series compensation distance relay applications where special adjustments to settings and/or logic are required to ensure correct protection performance? Zhao Xicai NARI-RELAYS CHINA

Protection for SC T/L Main Ⅰ –Pilot distance relay –Pilot zero sequence directional relay –Under-reach DPFC distance relay –Three zones phase distance relay –Three zones ground distance relay –Two delayed zones of zero sequence directional over- current relay Main Ⅱ –Phase-segregated current differential relay –Zero sequence differential current relay –Under-reach DPFC distance relay –Three zones phase distance relay –Three zones ground distance relay –Two delayed zones of zero sequence directional over- current relay

DPFC Distance Relay DPFC-Deviation of Power Frequency Component

Distance Relay Polarizing Voltage –Positive sequence voltage and –Memory voltage

Distance Relay Two Relays with Different Memory Decay time Operate simultaneously-Forward fault Operate one after another-Backward fault

Distance Relay Uplv= Protection Voltage of MOV.

Zero-Sequence Directional Relay Additional Source Impedance Introduced